Benutzeranleitung / Produktwartung FX82012 des Produzenten Pelco
Zur Seite of 36
® INST ALLA TION FX82012 Unmanaged Ethernet Switch One 10BASE-T/100BASE-TX Port and T wo 100BASE-FX Fiber Ports C2624M (6/07).
2 C2624M (6/07) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C2624M (6/0 7) 3 List of T ables A TX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 B FX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 C2624M (6/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation open ings.
C2624M (6/0 7) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
6 C2624M (6/07) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation.
C2624M (6/0 7) 7 Product Overview DESCRIPTION The FX82012 unmanaged Ethernet switch provides one 10BASE-T/100BASE- TX port and two 100BASE-FX fiber ports for the transport of bidi rectional Ethernet data.
8 C2624M (6/07) Features of the FX 82012 Ethernet switch include the following: • User -selectable 10BASE-T/100BAS E-TX networking functions: – Autonegotiation between 10 Mbps and 100 Mbps data ra.
C2624M (6/0 7) 9 MODELS The FX82012 module consists of t he followin g series of models: Multimode Models:* FX82012MSTR-2 Unmanaged Ethernet switch, one 10BASE-T/100BASE-TX port, two multimode ST fibe.
10 C2624M (6/07) FRONT PANEL Figure 3 illustrates the front panel of the FX82012 module. Figure 3. Front Panel of FX82012 Module For detailed information about the front-panel LEDs, refer to the T roubleshooting section.
C2624M (6/0 7) 11 REAR PANEL Figure 4 illustrates the rear panel of the FX82012 module. Figure 4. Rear Panel of FX82012 Module (SC Fiber Connectors Shown) For additional informati on about rear -panel connections, refer to the Installation section. For detailed information about the RJ-45 LEDs, refer to the T roubleshooting section.
12 C2624M (6/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 FX82012 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4 -40 x 0.
C2624M (6/0 7) 13 Using the TX Mode switch, you can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the FX82012.
14 C2624M (6/07) SETTING FIBER FAILOVER MODE NOTE: As a matter of convenience, it is recomm ended that y ou set fiber failover (redundancy) mode—if required—befor e mounting the FX8201 2 module into a ra ck or onto a wall. Fiber failover mode is disabled by default.
C2624M (6/0 7) 15 Ta b l e B . FX Mode Switch Settings MOUNTING The FX82012 module can be mounted into a rack or c an be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall.
16 C2624M (6/07) MOUNTING THE FX82012 MODULE TO A WALL The FX82012 module can be mounted to a wall in the following ways: • Using the supplied wall clip fo r attachment of a single module to a wa ll. For installation instructions, refer to the Mounting the FX82012 Module Using the Wall Clip secti on.
C2624M (6/0 7) 17 Figure 7. Mounting the FX82012 Module Using the Wall Cl ip UPPER FLANGE VERTI C AL MOUNTING HOLE (2) HORIZONT AL MOUNTING HOLE (2) LOWER FLANGE W ALL C LIP SC REW , PHILLIP S P AN HE.
18 C2624M (6/07) CONNECTIONS Connections to the FX82012 module are made on the rear panel of the modul e (refer to Figure 8). Figure 8. FX82012 Connections (SC Fi ber Connectors Shown) As illustrated .
C2624M (6/0 7) 19 • Fiber connections – When connecting fiber between FX82012 models, connect fiber port A of one module to fiber port B of another module.
20 C2624M (6/07) Figure 9. Fiber Port Conn ections in Point-to-Point Application with Redundancy FX MODE POSITION 2: FIBER PORT B IS PRIMARY . FIBER PORT A IS SECONDARY . SECONDARY FIBER LINK PRIMARY FIBER LINK FX MODE POSITION 1: FIBER PORT A IS PRIMARY .
C2624M (6/0 7) 21 Figure 10. Fiber Port Connections in Samp le Drop-and-Repeat Application FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT . FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT . FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT .
22 C2624M (6/07) T roubleshooting LED indicators on the front and rear panels of the FX82012 module allow you to monitor operational status: • LED indicators on the front panel allow y ou to monitor operating power , fiber redundancy mode status, 100BASE-FX port status, and optic signal/laser status.
C2624M (6/0 7) 23 Fiber Failover Mode LED ( ) Not lit The module is not in fiber redundancy mode. The FX Mode switch is set to position 0. If fiber redundancy is not required, no action is required. If fiber redundancy is required, power off the module, set the FX Mode switch to position 1 or 2 as appropriate, and then power on the module.
24 C2624M (6/07) 100BASE-FX Status LED ( ) Green A fiber link is established. — No action required. Flashing green Da ta activity is occurring on the fiber link—data is being transmitted or received. — No action required. Red Far end fault indication (FEFI).
C2624M (6/0 7) 25 Optic Fault LED ( ) Green The optical signal is being received and laser is operating properly . — No action required. Red The optical signal is not being received. Remote module is not powered on. Check power connections. Replace power supply if necessary .
26 C2624M (6/07) T able D. T roubleshooting with Rear -Panel Indicators Indicator Color Meaning Possible Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port Stat us LED - Left (Link / Activity) Amber A 10BASE-T link is established. — If 10BASE-T operation is desired, no action is required.
C2624M (6/0 7) 27 RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit A 10BASE-T or 100BASE-TX link cannot be established. A problem may exist with the cable: • Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device.
28 C2624M (6/07) RJ-45 10BASE-T/100BASE-TX Port St atus LED - Right (Duplex/Collision) Amber Port is set to 10BASE-T full- duplex mode. — If 10BASE-T full-duplex opera- tion is desired, no action is required.
C2624M (6/0 7) 29 RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Green Port is set to 100BASE-TX full- duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required.
30 C2624M (6/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Not lit Port is set to 10BASE-T half- duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired , no action is required.
C2624M (6/0 7) 31 Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.
32 C2624M (6/07) OPTICAL POWER BUDGET AND MAXI MUM TRANSMISSION DIST ANCE Model Number Number of Fibers Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance Fiber Port A Fiber Port B Multimode (62.5/125 μm) FX82012MSTR-2 2 (1 per port) 1310/850 nm 850/1310 nm 26 dB † 2 km (1.
C2624M (6/0 7) 33 Appendix. RJ-45 Connector Pinouts Figure 11 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 11. RJ-45 MDI/MDI-X Connector Pinouts T able E summarizes RJ-45 MDI/MDI-X connector pinouts.
34 C2624M (6/07) The materials used in the manufacture of this document and its components are compliant to t he requirements of Directive 2002/95/EC. This equipment contains electrica l or electronic.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment.
® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Ein wichtiger Punkt beim Kauf des Geräts Pelco FX82012 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco FX82012 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco FX82012 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco FX82012 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco FX82012 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco FX82012 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco FX82012 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco FX82012. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco FX82012 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.