Benutzeranleitung / Produktwartung DX3016-060 des Produzenten Pelco
Zur Seite of 85
The DX3000 Series DVR has an unmarked lock button to restrict unauthorized use of the re- corder . The lock button will work only as long as no one discovers its function. Since you may need to make the manual accessible to others, the lock button’s location and operation are NOT documented in the manual – this is the only place it is shown.
DX3000 Series Digital Recor der Installation/ Operation Manual C681M-D (2/02) ® Pelco • 3500 Pelco W ay • Clovis, CA 93612-5699 USA • Pelco Online @ www .
2 Pelco Manual C681M-D (2/02) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND WARNINGS ................................................................ 5 OVERVIEW ........................................................................................
Pelco Manual C681M-D (2/02) 3 TCP/IP SETTING (DX3016 Models Only) ................................................................. 49 TIME AND DA TE DISPLA Y ....................................................................................... 49 DISPLA Y MODE .
4 Pelco Manual C681M-D (2/02) LIST OF ILLUSTRA TIONS Figur e Page 1 Front Panel Controls, DX3009 Models .............................................................. 7 2 Front Panel Controls, DX3016 Models ............................................
Pelco Manual C681M-D (2/02) 5 IMPOR T ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and con- form to all local codes.
6 Pelco Manual C681M-D (2/02) OVERVIEW DESCRIPTION The DX3000 Series Digital Video Recorder (DVR) is a high-quality digital recorder that combines the functions of a recorder and multiplexer into one unit. With the number of cameras in systems increasing, the combination of a video recorder with a multiplexer has become standard.
Pelco Manual C681M-D (2/02) 7 0 3 2 14 6 5 CAMERA 9 8 7 REC ARCHIVE SPLIT/SEQUENCE ZOOM STOP WARNING RESET SEARCH COPY SET UP MENU INFO PAUSE REV PLAY PLAY PLAY MODE -+ CLEAR/ REW ENTER/ FF TIMER R.
8 Pelco Manual C681M-D (2/02) 3. Recording indicators TIMER REC indicator This light illuminates during timer recording and timer recording standby mode. The POWER button does not work when the TIMER REC indicator is lit. T o turn on the power when the TIMER REC indicator is lit in the standby mode, press the TIMER REC button.
Pelco Manual C681M-D (2/02) 9 8. Mode indicators ACCESS indicator This light flashes when the hard disk drive or peripheral recording devices are being accessed. LOCK indicator This light illuminates when the LOCK button is set to ON. 9. Menu buttons Press one of the buttons to display each menu.
10 Pelco Manual C681M-D (2/02) CLOCK ADJ REC POWER ON POWER OFF ALARM OUT MODE OUT CALL OUT CALL OUT GND GND DC 5V OUT MAX 30mA 1 MIC IN OUT 23456789 1 RS-232C 234 1 GND 23456789 CAMERA IN AUDIO C.
Pelco Manual C681M-D (2/02) 11 6. AC power socket This socket is for a 100-240 V AC power cord. 7. RS-232C connector This is where a PelcoNet™ T ransmission System can be connected for remote view- ing and control of cameras. 8. ALARM IN terminals These are input terminals for alarm signals.
12 Pelco Manual C681M-D (2/02) CLOCK ADJ REC POWER ON POWER OFF ALARM OUT MODE OUT CALL OUT CALL OUT GND DC 5V OUT MAX 30mA 1 MIC IN OUT 23456789 1 RS-232C 234 123456789 CAMERA IN AUDIO CAMERA OUT ALA.
Pelco Manual C681M-D (2/02) 13 <Interface circuit inside the unit> 5V 5V 10k Ω 22k Ω Input terminal 0.047 µ F GND PO WER ON/POWER OFF/ ALARM IN/REC/CLOCK ADJ Input t.
14 Pelco Manual C681M-D (2/02) REC ALARM-OUT POWER OFF POWER ON MODE-OUT CALL OUT GND CALL OUT DC 5V OUT MAX 30mA CLOCK ADJUST REC POWER ON POWER OFF ALARM OUT MODE OUT CALL OUT CALL OUT GND First Unit Second Unit GND GND GND GND GND <Interface circuit inside the unit> 5V 5V 10k Ω 22k Ω Input terminal 0.
Pelco Manual C681M-D (2/02) 15 CLOCK ADJ REC POWER ON POWER OFF ALARM OUT MODE OUT CALL OUT CALL OUT GND DC 5V OUT MAX 30mA RS-232C 123456789 ALARM IN RESET ON OFF SCSI TERMINATION SCSI cable Pe r iph.
16 Pelco Manual C681M-D (2/02) <DEVICE CHECK> SCSI ID0:HDD (30GB) ID1:HDD ( 9GB) ID2:NONE ID3:NONE ID4:NONE ID5:NONE PWR-OFF INITIALIZE BOOT UP DELA Y 00 ID4:RDD ID5:DDS PWR-OFF BOOT UP DELA Y 00 6.
Pelco Manual C681M-D (2/02) 17 <DEVICE CHECK> SCSI ID0:HDD (30GB) ID1:HDD ( 9GB) ID2:NONE ID3:NONE ID4:NONE ID5:NONE INITIALIZE ALL HDD BOOT UP DELA Y 00 ID5:RDD PWR-OFF CONFIG. BOOT UP DELA Y 00 REMOVING A HARD DRIVE(S) This section applies only to devices removed from ID1-ID3.
18 Pelco Manual C681M-D (2/02) PROGRAMMING Figure 13. Menu T ree, DX3009 Models <MENU SETTING> TIME DATE DISPLAY MPX DISPLAY TIMER PROGRAM NORMAL REC SETTING A-REC/M-DET SETTING DATA CLEAR SELECTION COMMUNICATION SETTING <TIME DATE DISPLAY> DISPLAY MODE 1 CHARACTER SIZE SMALL CLOCK LOCATION OFF EX.
Pelco Manual C681M-D (2/02) 19 Figure 13. Menu T ree, DX3009 Models (Continued) <MOTION> SELECTION CAMERA NO. 1 CH.MOTION DETECTION OFF SET DETECTION MASK SENSITIVITY MED MOTION THRESHOLD 2 TEST.
20 Pelco Manual C681M-D (2/02) Figure 14. Menu T ree, DX3016 Models SU B M EN U ( 1 ) S UB ME N U (2) 01 137.
Pelco Manual C681M-D (2/02) 21 Figure 14. Menu T ree, DX3016 Models (Continued) 01 136 (NOT USED).
22 Pelco Manual C681M-D (2/02) ALARMS IMAGE QUALITY Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. T urn the JOG dial to move the cursor to A-REC/M-DET SETTING, and then turn the SHUTTLE ring to the right.
Pelco Manual C681M-D (2/02) 23 DEFINE GROUP SETTING Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. T urn the JOG dial to move the cursor to A-REC/M-DET SETTING, and then turn the SHUTTLE ring to the right.
24 Pelco Manual C681M-D (2/02) ALARM RECORDING DURA TION Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. T urn the JOG dial to move the cursor to A-REC/M-DET SETTING, and then turn the SHUTTLE ring to the right.
Pelco Manual C681M-D (2/02) 25 4. T urn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. The option stops flashing. T urning the JOG dial switches the record alarm optio.
26 Pelco Manual C681M-D (2/02) 6. Do one of the following: •T urn the JOG dial to go to another item in this menu. •T urn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an- other menu. • Press the SET UP button to exit the programming mode.
Pelco Manual C681M-D (2/02) 27 4. T urn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. T urning the JOG dial switches the archive data options as follows: ALL: This backs up all the data recorded on the main hard disk after the archive pointer .
28 Pelco Manual C681M-D (2/02) AUDIO RECORDING The recorder can record audio with an image. Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. T urn the JOG dial to move the cursor to INITIAL SET UP , and then turn the SHUTTLE ring to the right.
Pelco Manual C681M-D (2/02) 29 5. Do one of the following: •T urn the JOG dial to go to another item in this menu. •T urn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an- other menu. • Press the SET UP button to exit the programming mode.
30 Pelco Manual C681M-D (2/02) CALL OUT A signal from the CALL OUT terminal can be sent to an external device to warn when the hard disk drive or archive device reaches the remaining capacity set in this menu. The call out signal can also activate another recorder if the CALL OUT terminal is wired to the record (REC) input of another recorder .
Pelco Manual C681M-D (2/02) 31 4. T urn the JOG dial to select the device. T urning the JOG dial switches the device options as follows: HDD, ARC, NONE Select HDD if the MODE OUT terminal is wired to the record (REC) input of another recorder . 5. T urn the SHUTTLE ring to the right.
32 Pelco Manual C681M-D (2/02) 5. Do one of the following: •T urn the JOG dial to go to another item in this menu. •T urn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an- other menu. • Press the SET UP button to exit the programming mode.
Pelco Manual C681M-D (2/02) 33 HARD DISK DRIVE (HDD) FULL When the end of the hard disk drive (HDD) is reached during recording, this function deter- mines what the recorder will do. Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu.
34 Pelco Manual C681M-D (2/02) HARD DISK DRIVE (HDD) REPEA T PLA YBACK When the end of the hard disk drive (HDD) is reached during playback, you can set the re- corder either to stop playback or to continue playback from the beginning of the disk. Skip steps 1 and 2 if they have already been done.
Pelco Manual C681M-D (2/02) 35 5. Do one of the following: •T urn the JOG dial to go to another item in this menu. •T urn the SHUTTLE ring to the left to return to the Menu Setting menu to go to another menu. • Press the SET UP button to exit the programming mode.
36 Pelco Manual C681M-D (2/02) 4. T urn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. The option stops flashing. T urning the JOG dial switches the mode out options as follows: REC, PLA Y , POWER, REMAIN REC: The signal is output during recording.
Pelco Manual C681M-D (2/02) 37 7. Turn the JOG dial to select the M-DET SETTING, and then turn the SHUTTLE ring to the right. The Motion menu appears. This menu will not appear if the MOTION DE- TECTION setting in the Initial Set Up menu is OFF . 8. Check that the cursor is next to SELECTION CAMERA NO.
38 Pelco Manual C681M-D (2/02) 18. Turn the JOG dial to select the threshold, and then turn the SHUTTLE ring to the right. The option stops flashing. Select a number between 1 and 120. The number is the minimum number of active dots required to initiate alarm recording.
Pelco Manual C681M-D (2/02) 39 Four-Camera (Split 4) Setting In the SPLIT 4 setting mode, you select which camera images to show in a four-camera display . Three different groups of cameras can be defined. Skip steps 1-3 if they have already been done.
40 Pelco Manual C681M-D (2/02) SPLIT 4 SCREEN SETTING (DX3016 Models Only) In the Split 4 Screen Setting, you select which camera images to show in a four-camera display . Four different groups of cameras can be defined. Skip steps 1 and 2 if they have already been done.
Pelco Manual C681M-D (2/02) 41 SPLIT 16 SCREEN SETTING (DX3016 Models Only) Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. T urn the JOG dial to move the cursor next to MPX DISPLA Y , and then turn the SHUTTLE ring to the right.
42 Pelco Manual C681M-D (2/02) SEQUENCE Cameras can be sequenced individually , in groups of four cameras, or , for the DX3016 models only , in groups of nine cameras. Set all sequence patterns. These are the patterns that will be displayed when the SPLIT/SEQUENCE button is pushed (refer to the Operation section).
Pelco Manual C681M-D (2/02) 43 3. T urn the JOG dial to move the cursor to CH.TITLE, and then turn the SHUTTLE ring to the right. The option starts flashing. NOTE: If the PRE A-REC field in the A-Rec/M-Det Setting menu has been set to SHORT , MEDIUM, or LONG, the option does not flash because it cannot be changed.
44 Pelco Manual C681M-D (2/02) CAMERA TITLE T itles can be added for each camera. In single-camera display mode, up to 16 characters can be displayed. In four-camera display mode, the first 8 characters are displayed. T itles cannot be displayed in nine-camera or sixteen-camera display mode.
Pelco Manual C681M-D (2/02) 45 4. T urn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. The flashing stops. T urning the JOG dial changes the image quality setting as follows: BASIC, ST ANDARD, MEDIUM, HIGH, SUPERIOR 5.
46 Pelco Manual C681M-D (2/02) SELECT RECORDING MODE There are three recording modes: A, B, and C. For example, mode A might be used for daytime recording, mode B for nighttime recording, and mode C for weekend recording. The cameras that will record in each mode are selected in the next section, Define Group .
Pelco Manual C681M-D (2/02) 47 5. T urn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. The option stops flashing. T urning the JOG dial changes the priority setting as.
48 Pelco Manual C681M-D (2/02) SA VING MENU SETTINGS Complex menu settings can be saved on a peripheral recording device connected to SCSI ID number 5.
Pelco Manual C681M-D (2/02) 49 TCP/IP SETTING (DX3016 Models Only) This menu is not used. TIME AND DA TE DISPLA Y DISPLA Y MODE Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Make sure the cursor is next to TIME DA TE DISPLA Y , and then turn the SHUTTLE ring to the right.
50 Pelco Manual C681M-D (2/02) 4. T urn the JOG dial to select 1-6, and then turn the SHUTTLE ring to the right. The option stops flashing. An example of the display mode appears on the screen, as shown in the chart below . 5. Do one of the following: •T urn the JOG dial to go to another item in this menu.
Pelco Manual C681M-D (2/02) 51 CLOCK LOCA TION Skip steps 1 and 2 if they have already been done. 1. Press the SET UP button to display the Menu Setting menu. 2. Make sure the cursor is beside TIME DA TE DISPLA Y , and then turn the SHUTTLE ring to the right.
52 Pelco Manual C681M-D (2/02) 8. Do one of the following: •T urn the JOG dial to go to another item in this menu. •T urn the SHUTTLE ring to the left to return to the Menu Setting menu to go to another menu. • Press the SET UP button to exit the programming mode.
Pelco Manual C681M-D (2/02) 53 11 . Repeat steps 8-10 for the ending time. A dot between the columns for the starting and ending times indicates that the record- ing time overlaps into the following day; for example, if you select 5 p.m. to 8 a.m. 12.
54 Pelco Manual C681M-D (2/02) 16. Turn the SHUTTLE ring to the left to return to the Timer Program menu. Repeat steps 3-15 to define other patterns. 17.
Pelco Manual C681M-D (2/02) 55 MOTION DETECTION DURING A TIMER RECORDING (DX3016 Models Only) This function allows you to set up motion detection to operate during a specified time pe- riod.
56 Pelco Manual C681M-D (2/02) <TIMER PROGRAM> P1 DW START END MODE 1 DAY 12:00 13:00 DAY 16:00 22:00 3 ——— ——:—— ——:—— 00509 01138 ESTIMA TING RE.
Pelco Manual C681M-D (2/02) 57 01 - 01 - 2000 SA T A0001 00 : 00 : 00 15F 50% C1 Y ear Month Date Day of the week Alarm recording number Minute Second Time Recording interval Camera number Recorded capacity of the Hard Disk Non-operation camera mark OPERA TION Press the POWER button on the front of the recorder to turn on the unit.
58 Pelco Manual C681M-D (2/02) VIEWING CAMERAS NOTE: Y ou cannot operate the CAMERA buttons when a menu is displayed on the screen. The buttons do not work when the recorder is accessing a peripheral recording device or the ARCHIVE, COPY , or PLA Y button is flashing.
Pelco Manual C681M-D (2/02) 59 ZOOM BUTTONS NOTE: Y ou cannot operate the ZOOM buttons when a menu is displayed on the screen. The buttons do not work when the recorder is accessing a peripheral recording device or the ARCHIVE, COPY , or PLA Y button is flashing.
60 Pelco Manual C681M-D (2/02) ALARM RECORDING Alarm recording commences upon either of the following conditions: • An ALARM IN terminal is triggered by an alarm sensor •A camera detects motion When there is an alarm: 1) The recorder switches to its preset recording intervals.
Pelco Manual C681M-D (2/02) 61 TIMER RECORDING 1. Select the timer program (P1, P2, or P3) that you want to use for recording. Refer to T imer Recording in the Programming section. 2. Press the TIMER REC button. The TIMER REC indicator illuminates. If the current time is covered by a program, the unit begins recording immediately .
62 Pelco Manual C681M-D (2/02) FRAME-BY -FRAME (STILL FRAME) PLA YBACK 1. Press the P AUSE button during playback. The unit shifts into still-frame mode. 2. If the screen shows more than one camera, you can view a full-screen view of a single camera by pressing the CAMERA button for that camera.
Pelco Manual C681M-D (2/02) 63 Still-Frame Playback Mode 1. Press the P AUSE button while the recorder is in playback or reverse playback. The unit shifts to still-frame playback mode. 2. T urn the SHUTTLE ring to the desired playback speed. 3. The unit shifts to still-frame playback mode when the SHUTTLE ring is returned to the center position.
64 Pelco Manual C681M-D (2/02) 4. Turn the JOG dial to move the cursor beside TIME DA TE SEARCH, and then turn the SHUTTLE ring to the right. The Time Date Search menu appears and the month num- ber starts flashing. NOTE: If the PRE A-REC field in the A-Rec/M-Det Setting menu has been set to SHORT , MEDIUM, or LONG, the menu cannot be accessed.
Pelco Manual C681M-D (2/02) 65 Present position Beginning of playback device End of playback device -15 -1 -2 +1 +15 +2 A•REC A•REC A•REC A•REC A•REC A•REC A•REC: Alarm Recording 6. Turn the SHUTTLE ring in the desired search direction. The present position in the diagram below represents the point of playback or stopped playback.
66 Pelco Manual C681M-D (2/02) Alarm List Search The Alarm List search retrieves alarm video at the time an alarm occurred. It does not re- trieve pre-alarm recording if the pre-alarm recording option was turned on (PRE A-REC field in the A-Rec/M-Det Setting menu).
Pelco Manual C681M-D (2/02) 67 5. Press the PLA Y or P AUSE button to play back the searched image. 6. Press the STOP button to stop playback and exit the search function. PLA YBACK ON ANOTHER DEVICE Data recorded on an external copying or archiving device can be played back on a per- sonal computer or laptop computer .
68 Pelco Manual C681M-D (2/02) Auto-Eject at the Completion of Backup The archive medium will be automatically ejected under the following conditions: When the archive medium becomes full during archive backup. Refer to Auto Eject in the Programming section.
Pelco Manual C681M-D (2/02) 69 SUPERIOR HIGH MEDIUM ST ANDARD BASIC Non- selectable 30F 15F 7.5F 5F :Simultaneous backup is possible without audio :Simultaneous backup is possible with audio IMAGE QUALITY Field/sec. b. Use the JOG dial and SHUTTLE ring to set the month, date, year , hour , minute, and second of the starting time.
70 Pelco Manual C681M-D (2/02) RECORDING A- 7.5F (or POWER setting) Illustration 1: Correct setting Backup Longer than 5 minutes RECORDING A- 7.5F (or POWER setting) Backup RECORDING A- 7.5F (or POWER setting) Longer than 1 minutes Longer than 1 minutes Illustration 2 3.
Pelco Manual C681M-D (2/02) 71 INFORMA TION ELAPSED TIME DISPLA Y 1. Press the INFO button. The Information menu appears. The elapsed time appears in the lower part of the screen. 2. T o exit the menu, press the INFO button again. The elapsed time of main hard disk drive, archive device, and copy device are shown on the screen.
72 Pelco Manual C681M-D (2/02) RECORDED PERIOD The recorded periods of the main hard disk drive, the archive device, and the copy device are shown on the screen. The archive device is displayed only when an archive device is connected to ID4. The copy device is displayed only when a copy device is connected to ID5.
Pelco Manual C681M-D (2/02) 73 Audio recording possible. (12.8kHz sampling) Audio recording possible, but with diminished quality . (8kHz sampling) Audio recording not possible.
74 Pelco Manual C681M-D (2/02) 30F 15F 7.5F 5F 3F 1F Field/sec. SUPERIOR HIGH MEDIUM ST ANDARD BASIC 2s 3s 5s 6s 8s 4s 7s 10s 13s 16s 9s 14s 20s 26s 33s 13s 21s 30s 40s 50s 23s 36s 51s 1min7s 1min24s 1min9s 1min48s 2min33s 3min21s 4min12s IMAGE QUALITY 30F 15F 7.
Pelco Manual C681M-D (2/02) 75 ♦ Without audio Pre-Alarm Recording, r ecording duration is set to SHORT . ♦ Audio recor ding, Pre-Alarm Recording duration is set to LONG. ♦ Audio recor ding, Pre-Alarm Recording duration is set to MIDDLE. ♦ Audio recor ding, Pre-Alarm Recording duration is set to SHORT .
76 Pelco Manual C681M-D (2/02) Audio recording possible. (12.8kHz sampling) Audio recording possible, but with diminished quality . (8kHz sampling) Audio recording not possible.
Pelco Manual C681M-D (2/02) 77 DX3016 RECORDING TIME T ABLES (Continued) Audio recording possible. (12.8kHz sampling) Audio recording possible, but with diminished quality . (8kHz sampling) Audio recording not possible. ■ Pre-alarm recor ding time table ♦ Without Audio recor ding, recording duration is set to LONG.
78 Pelco Manual C681M-D (2/02) DX3016 RECORDING TIME T ABLES (Continued) Audio recording possible. (12.8kHz sampling) Audio recording possible, but with diminished quality . (8kHz sampling) Audio recording not possible. ♦ Audio recor ding, recording duration is set to MEDIUM.
Pelco Manual C681M-D (2/02) 79 W ARNINGS The following table tells you what to do if a warning appears on your monitor . Options in the CALL OUT options column: • Selectable: CALL OUT output can be selected or deselected in the Call Out setting in the Rear T erminal menu and the HDD Full setting in the Initial Set Up menu.
80 Pelco Manual C681M-D (2/02) Description of pr oblem Please consult the follo wing The unit will not turn on. Power is on, but the unit will not operate. Images are not appearing on the monitor . The quality of the monitor picture is poor . The unit will not start recording.
Pelco Manual C681M-D (2/02) 81 OTHERS Description of pr oblem Please consult the follo wing The unit will not respond to PC control. The DEVICE CHECK menu does appear when power is turned on. The unit is not detecting its peripheral recording device(s).
82 Pelco Manual C681M-D (2/02) SPECIFICA TIONS ELECTRICAL/VIDEO/AUDIO Input V oltage: 100-240 V AC, 50/60Hz Power Consumption: 150W maximum Signal System: NTSC Recording System: Digital recording system with JPEG compression method Sampling: 13.
Pelco Manual C681M-D (2/02) 83 Inputs/Outputs POWER ON: Input for power ON. Low input state is power off; high input state is power on. POWER OFF: Input for power OFF . Low input state is power of f. ALARM IN (1-9): Inputs for starting alarm recording.
84 Pelco Manual C681M-D (2/02) ® Pelco, the Pelco logo, Spectra, Genex, and Legacy are registered trademarks of Pelco. © Copyright 2002, Pelco. ™ Esprit, Camclosure, and PelcoNet are trademarks of Pelco. All rights reserved. W ARRANTY AND RETURN INFORMA TION REVISION HISTOR Y Manual # Date Comments C681M 01/01 Original version.
Ein wichtiger Punkt beim Kauf des Geräts Pelco DX3016-060 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco DX3016-060 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco DX3016-060 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco DX3016-060 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco DX3016-060 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco DX3016-060 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco DX3016-060 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco DX3016-060. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco DX3016-060 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.