Benutzeranleitung / Produktwartung C841M-A des Produzenten Pelco
Zur Seite of 16
INST ALLA TION/OPERA TION V A6200 Series Sequential Switcher C841M-A (7/02).
2 C841M-A (7/02) LIST OF ILLUSTRA TIONS Figure Page 1 Jumper Settings - V A6200 Series ............................................................................................... ....................................................................
C841M-A (7/02) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes.
4 C841M-A (7/02) INST ALLA TION 1. Remove the cover from the switcher . 2. Set the jumpers as required for your application. Refer to Figure 1 and T able A. 3. Replace the cover . 4. Place the unit on a flat surface or install it in an equipment rack using the appropriate rack-mount kit.
C841M-A (7/02) 5 Table A. Jumper Settings - VA6200 Series Jumper Position Function JP1 - JP20 A Camera input terminated (75 ohms) B Camera input looping (high impedance) JP23, JP24, JP25, JP26, JP28, .
6 C841M-A (7/02) Figure 2. Fixed Cameras with Terminated Inputs Figure 3. Fixed Cameras with Looping Outputs.
C841M-A (7/02) 7 Figure 4. Movable Cameras with Terminated Inputs and Coaxitron Control Figure 5. Movable Cameras with Looping Outputs and Coaxitron Control.
8 C841M-A (7/02) Figure 6. Connector Assembly.
C841M-A (7/02) 9 OPERA TION T o operate the VA6200 Series Switcher: 1. Plug in the power cord. 2. Select the monitor by pushing the MON 1 or MON 2 button. 3. Press a camera button to view video from the corresponding camera. SEQUENCING T o run a sequence: 1.
10 C841M-A (7/02) DWELL TIME The time between switching from one camera to another is known as the dwell time. The dwell time can be set differently for each camera or it can be set the same (global) for all cameras on a monitor . T o check the dwell time: 1.
C841M-A (7/02) 11 ALARMS The alarm inputs must be enabled or disabled if you connected alarms on the switcher to them. T o enable or disable alarms: 1. Press the MON 1 button. 2. Press the recessed ALARM switch. The switch toggles the alarm inputs on and off.
12 C841M-A (7/02) TROUBLESHOOTING PROBLEM SOLUTION No power Check the fuse . Video output quality poor Check jumper settings (Refer to Figure 1, T able A). (Examples: Squiggly video, poor contrast, picture not centered) Locked system or sequencing not working as desired Reset the switcher .
C841M-A (7/02) 13 SPECIFICA TIONS VIDEO Inputs: T erminating (75 ohms) or looping (high impedance) NTSC and PAL compatible Outputs Monitor 1: 75 ohms Monitor 2: 75 ohms; half duplex (Coaxitron ® compatible).
14 C841M-A (7/02) GENERAL Construction Chassis: Steel, zinc plated Cover: Steel, textured black enamel Panel: Aluminum, with LEXAN ® overlay Dimensions V A6204 Series: 1.75 (H) x 5.50 (W) x 9.25 (D) inches (4.44 x 13.97 x 23.49 cm) V A6208 Series: 1.
C841M-A (7/02) 15 REVISION HISTORY Manual # Date Comments C841M 12/99 Original version. C841M-A 7/02 Updated manual to new format. Removed reference to alarm breakout panel. PRODUCT WARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy , and Spectra are registered trademarks of Pelco.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
Ein wichtiger Punkt beim Kauf des Geräts Pelco C841M-A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco C841M-A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco C841M-A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco C841M-A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco C841M-A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco C841M-A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco C841M-A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco C841M-A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco C841M-A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.