® Pelco World Headquarters • 3500 Pelco Way, Clovis, California 93612-5699 USA • www.pelco.com USA & Canada: Tel: 800/289-9100 • Fax: 800/289-9150 International: Tel: 1-559/292-1981 • Fax: 1-559/348-1120 ADDENDUM Addendum No.
CM9760-REL System 9760 ® Relay Interface Unit Installation/ Operation Manual C538M-A (3/04) ® Pelco W orld Headquar ters • 3500 P elco W a y , Clovis, CA 93612-5699 USA • www .
2 Pelco Manual C538M-A (3/04) CONTENTS Section Page 1.0 GENERAL ................................................................................................... 3 1.1 IMPOR T ANT SAFEGU ARDS AND W ARNINGS ................................ 3 2.0 DESCRIPTION .
Pelco Manual C538M-A (3/04) 3 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser v ed.
4 Pelco Manual C538M-A (3/04) 2.0 DESCRIPTION The CM9760-REL Rela y Interface Unit is an optional accessory of the System 9760 ® . The relay interf ace unit provides dry contact switching for direct or automatic con- trol of peripheral equipment. The unit connects to any RS-422 COMM port on the rear of the CM9760-CC1.
Pelco Manual C538M-A (3/04) 5 3.0 PRE-INST ALLA TION INFORMA TION 3.1 FRONT VIEW AND DIP SWITCH ACCESS Figure 1 illustrates a front vie w of the unit with its front panel removed. P ower (green) and Data (red) LEDs occupy opposite ends of the unit’ s front panel.
6 Pelco Manual C538M-A (3/04) 3.2 REAR VIEW The rear of the unit is illustrated in Figure 2. F rom left to r ight are the f ollowing: 1. F our b locks consisting of 16 contact pairs, each with mating plugs f or the at- tachment of peripheral equipment.
Pelco Manual C538M-A (3/04) 7 3.2.1 REL Contact Pair Connections Physically , each rela y bloc k consists of 16 rela y contacts and two mating plugs. Since a relay contact requires tw o terminal positions, each plug provides 8 contacts via 16 screw terminals.
8 Pelco Manual C538M-A (3/04) 3.2.2 External Relay Wiring Considerations Components of external rela y wiring are illustrated in Figure 4. 3.2.3 Communication Connectors Communication to and from the unit is provided through two RJ-45 ports on the rear of the CM9760-REL.
Pelco Manual C538M-A (3/04) 9 3.2.3.2 RJ-45 Data Cables Because both RJ-45 connectors hav e the same wir ing pin-outs , they require the same “flipped” cable .
10 Pelco Manual C538M-A (3/04) 3.2.4 Power Connections The CM9760-REL utilizes an auto-ranging internal transf ormer circuit that allows input power to range from 100-240 V A C , 50/60Hz. Associated with the input po wer is the power ON/OFF s witch and the input power fuse.
Pelco Manual C538M-A (3/04) 11 3.3 SETUP 3.3.1 Preliminary Discussion FRAME ADDRESSES The IRC, VCRC , and the CM9760-REL Rela y Interface Unit, all use software GPIs to activate control of e xter nal de vices. The number of GPIs required by each hardw are device v aries.
12 Pelco Manual C538M-A (3/04) When setting frame addresses on the front panel s witches for a group of daisy- chained REL units, k eep in mind a few working rules: WORKING RULES 1. Star t with frame address 0, which is associated with ph ysical GPI 1, and w ork sequentially forw ard until all relay interf ace units are accounted for .
Pelco Manual C538M-A (3/04) 13 3.3.2 DIP Switch Settings DIP switch settings are illustr ated and discussed in Figure 10. Figure 10. DIP Switch Functions.
14 Pelco Manual C538M-A (3/04) Ta b le A. Fr ame Address, GPI Range Association (Continued on ne xt page) Daisy-Chained Frame Sub-Frame Combined Associated GPI Range Relay Units Addresses Addresses Fr.
Pelco Manual C538M-A (3/04) 15 Ta b le A. Fr ame Address, GPI Range Association (Contin ued) 45 11 0100 0 0 1 1 0 353 354 355 356 357 358 359 360 46 11 0100 1 0 1 1 1 361 362 363 364 365 366 367 368 4.
16 Pelco Manual C538M-A (3/04) Figure 11. Configur ing the GPI Define File f or REL Operation Figure 12. Configur ing the COMMS File f or REL Operation 3.
Pelco Manual C538M-A (3/04) 17 4.0 INST ALLA TION Physical installation of the REL unit is relativ ely simple, although v arious configura- tions are possible . 4.1 DIRECT RACK-MOUNT HOOK-UP The REL unit mounts in a standard 19-inch rack and occupies only one R U (1.
18 Pelco Manual C538M-A (3/04) 4.3 DAISY -CHAINING Daisy-chaining occurs when more than 64 relays are required. More impor tantly , each unit must be configured to hav e a unique address , ref erred to as a F rame Address. F r ame addressing with respect to REL units was discussed in Section 3.
Pelco Manual C538M-A (3/04) 19 5.0 OPERA TION 5.1 OPERA TIONAL OVERVIEW The basic function of the REL unit is to allow the user/operator to control various peripheral equipment via relay contacts . Each REL unit processes and ex ecutes only commands with addresses that match that of the RELs (frame address).
20 Pelco Manual C538M-A (3/04) Figure 15. Ph ysical Representation of Figure 16 REL UNIT 1 REL UNIT 2 REL UNIT 3 REL UNIT 4 REL UNIT 5 PERIPHERAL DEVICES PERIPHERAL DEVICES PERIPHERAL DEVICES PERIPHER.
Pelco Manual C538M-A (3/04) 21 Method II – The CM9760-GPI/AUX Calculator If we re visit the EXAMPLE just discussed and illustrated in Figures 15, we can immediately find the inf ormation needed by direct read-off from the information bo x es on the front of the calculator .
22 Pelco Manual C538M-A (3/04) Figure 16. Controlling REL Output Contacts From the CM9760-KBD Once the system is running and a keyboard is on-line , direct control of an REL is as f ollo ws (refer to Figure 16): 1.
Pelco Manual C538M-A (3/04) 23 6.0 SPECIFICA TIONS ELECTRICAL REL UNIT RELAY CONTACTS** Parameters: Maximum Switching Capacity 60 Watts Maximum Operating Voltage 125V AC/DC Maximum Current 2 Amps Contact Resistance 75 m ohms Rated Load Parameters: .
24 Pelco Manual C538M-A (3/04) 7.0 W ARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved de- fective in material or workmanship for a period of one year after the date of shipment.
Ein wichtiger Punkt beim Kauf des Geräts Pelco C543M-A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco C543M-A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco C543M-A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco C543M-A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco C543M-A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco C543M-A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco C543M-A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco C543M-A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco C543M-A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.