DE
Panasonic logo
Offizielle Bedienungsanleitung

Panasonic AW-RC400E

272 Seiten·6.1 MB·Digitalkamera·PDF·ENNLJA
Panasonic AW-RC400E
Inhaltsverzeichnis 80 Abschnitte ESPAÑOL ENGLISH DEUTSCH FRANÇAIS ITALIANO · Pan/Tilt Head Controller AW-RP400E · Cable Compensator AW-RC400E · Roll Unit AW-RL400G · … AnzeigenAusblenden
ESPAÑOL ENGLISH DEUTSCH FRANÇAIS ITALIANOp.1Pan/Tilt Head Controller AW-RP400Ep.1Cable Compensator AW-RC400Ep.1Roll Unit AW-RL400Gp.1Before attempting to connect, operate or adjust this product,p.1ENGLISH VERSIONp.2Safety precautionsp.2$ DO NOT REMOVE PANEL COVER BYp.2Precautions for usep.4Introductionp.5Accessoriesp.5Installation precautionsp.6Parts and their functionp.7Rotary head connector panel Pedestal connector panelp.8A Fp.9B Ep.9C Dp.9Installation (Be sure to ask your dealer to install the unit.)p.11$ Assembling the pan/tilt headp.11For a stand-alone installationp.11$ Setting the mounting direction switchp.12$ Setting the PCB switchesp.13$ Changing the mounting position of the pedestal connector panelp.14$ Installing the pan/tilt headp.15For a stand-alone installation For installation on the ceilingp.15$ Mounting the camerap.16$ Attaching the chainp.17Replacing the consumable partsp.18$ Replacing the batteryp.18$ How to remove the batteryp.18$ How to install the batteryp.18$ Replacing the motorp.18$ Replacing the beltp.18$ Replacing the gearp.18Specificationsp.19NOTEp.20$ Front panelp.21J TRACING MEMORY [START POINT, STOP,p.23$ Rear panelp.24M N O P Qp.24U T S Rp.24EXT CONTp.24INp.24OUTp.24Menu settingsp.26$ Operation methodp.26AW-RP400p.26PAN/TILT CONTROLLERp.26PRIORITYp.26DIRECTION SETp.26DIRECTIONp.26PAN NORMALp.26TILT NORMALp.26TILT REVERSEp.26$ List of menu items and settingsp.27PRIORITY MASTER, SLAVE MASTERp.27DIRECTION PANp.27TILTp.27ZOOM NORMAL, REVERSE NORMAL FOCUSp.27IRISp.27ROTATIONp.27IRIS CONTROL BOTH, RP400, CB400 BOTHp.27ROTATION SWITCH ROTATION, FOCUS, ZOOM, IRIS ROTATIONp.27OPTION SWITCH Ap.27CONTROL SELECT MODE INTERLOCK, UN-INTERLOCK INTERLOCKp.27BUZZER OFF, ON ONp.27OPERATE STOP, RUN STOPp.27SD CARD STORE, LOAD – – –p.27PRIORITY (MASTER/SLAVE)p.27DIRECTION settings (PAN, TILT, ZOOM, FOCUS, IRIS, ROTATION NORMAL/REVERSE)p.28SPEED WITH ZOOM POS. setting (OFF/1/2/3)p.28PRESET SPEED setting (1 to 25)p.28IRIS CONTROL setting (BOTH/RP400/CB400)p.28ROTATION SWITCH setting (ROTATION/FOCUS/ZOOM/IRIS)p.28MEMORY LENGTH setting (60s/120s/300s/600s)p.29CONTROL SELECT MODE setting (INTERLOCK/UN-INTERLOCK)p.29MONITOR SELECT settingp.30BUZZER setting (OFF/ON)p.30AUTO RUN setting (START No., END No., INTERVAL)p.30SD CARD settingp.30
Page 1 of the Panasonic AW-RC400E user manual — Before attempting to connect, operate or adjust this product,
Seite 1 · Zum Vergrößern klicken
Seite 1
Panasonic AW-RC400E — ESPAÑOL ENGLISH DEUTSCH FRANÇAIS ITALIANO diagram (page 1)
Abb. 1

ESPAÑOL ENGLISH DEUTSCH FRANÇAIS ITALIANO

Pan/Tilt Head Controller AW-RP400E

Cable Compensator AW-RC400E

Roll Unit AW-RL400G

AW-PH400AW-RP400 AW-RC400AW-RL400
Panasonic AW-RC400E — ESPAÑOL ENGLISH DEUTSCH FRANÇAIS ITALIANO diagram (page 1)
Abb. 2

Before attempting to connect, operate or adjust this product,

Before attempting to connect, operate or adjust this product,

please read these instructions completely.

please read these instructions completely.

Page 2 of the Panasonic AW-RC400E user manual — $ DO NOT REMOVE PANEL COVER BY
Seite 2 · Zum Vergrößern klicken
Seite 2

ENGLISH VERSION

Safety precautions

$ DO NOT REMOVE PANEL COVER BY

UNSCREWING. To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel.

1 indicates safety information.

Page 3 of the Panasonic AW-RC400E user manual — ENGLISH VERSION
Seite 3 · Zum Vergrößern klicken
Seite 3
Page 3 of the Panasonic AW-RC400E user manual — ENGLISH VERSION
Page 4 of the Panasonic AW-RC400E user manual — Precautions for use
Seite 4 · Zum Vergrößern klicken
Seite 4

Precautions for use

≥Handle the ROP carefully.

Dropping the ROP or subjecting it to strong impact may give rise to malfunctioning or accidents.

≥Use the ROP in an ambient temperature of –10°C to +45°C.

Using the ROP in cold places below –10°C or hot places above 45°C may adversely affect its internal parts.

≥Turn off the power before connecting or disconnecting the cables.

Be absolutely sure to turn off the power before connecting or disconnecting the cables.

≥Avoid using the units outdoors.

Wipe the ROP using a dry cloth. To remove stubborn dirt, dip a cloth into a diluted solution of kitchen detergent, wring it out well, and wipe the ROP gently.

<Caution> ≥Avoid using benzine, paint thinners and other volatile fluids. ≥If a chemical cleaning cloth is to be used, carefully read through the precautions for its use.

≥Maintenance

Page 5 of the Panasonic AW-RC400E user manual — Precautions for use
Seite 5 · Zum Vergrößern klicken
Seite 5

Introduction

Panasonic AW-RC400E — Introduction diagram (page 5)
Abb. 3 · Introduction

≥The stand-alone compact pan/tilt head can be rotated

through 190 degrees in the vertical direction and 400 degrees in the horizontal direction.

≥Operations can be performed at high speeds of up to 90

≥In order to protect the environment when the pan/tilt

≥Equipment such as a camera and lens with a total weight

head is to be discarded at the end of its service life, ask a specialized contractor to dispose of it properly.

of 8 kg can be mounted on the unit.

≥The camera can also be rotated using the AW-RL400 roll

unit available as an option.

≥The shooting positions and settings for up to 50 positions

can be registered as preset memory data.

Accessories

Rotary arm 1 Camera mounting base 1 Rotary arm and camera base mounting screws (with flat washers)

M5!20 mm 7 Camera cable 1 Tally lamp 1 Chain mounting screws (with flat washers, spring washers)

M4!8 mm 1 M4!6 mm 1 Hexagon key wrench 1 AC cable 1

Precautions for use

The AW-PH400 uses a manganese dioxide-lithium battery (CR2032). Before discarding the pan/tilt head or its printed circuit boards, be absolutely sure to remove the battery. Be absolutely sure to dispose of the removed battery in accordance with the applicable domestic laws and regulations.

Do not throw out the battery along with the general household garbage. For the procedure to remove the battery, refer to the section on replacing the battery in “Replacing the consumables” (page 17).

Panasonic AW-RC400E — Precautions for use diagram (page 5)
Abb. 4 · Precautions for use

Replace the lithium battery here.

Page 6 of the Panasonic AW-RC400E user manual — Installation precautions
Seite 6 · Zum Vergrößern klicken
Seite 6

Installation precautions

≥Do not install the unit on any of its sides.

≥Avoid using the unit in the kitchen and other locations with lots of steam and oily vapors.

≥Mount the camera on the pan/tilt head only when you have finished installing it.

≥The maximum load-bearing capacity of this unit is 8 kg.

It cannot be used if the load to be borne exceeds 8 kg.

≥Do not use a lens which will impair or upset the unit’s balance.

Even if the load borne by the unit is less than 8 kg, it cannot be used if the unit will be set off-balance by the lens mounted on it.

≥Do not install the unit outdoors or in places where the temperature will be hotter than 45°C or colder than 0°C.

Use the unit in places where the humidity is below 90%.

≥Purchase the mounting screws separately since they are not supplied with the unit.

≥Do not hold or lift the unit by its rotating part. Doing so may cause malfunctioning.

≥Do not turn the unit’s rotating part by hand. Doing so may cause malfunctioning.

≥Dropping the unit or subjecting it to strong impact may give rise to malfunctioning.

≥Leave a clearance of at least 1 meter from around the monitor when installing the unit.

≥When mounting the camera on the unit, take sufficient steps to ensure that it will not become detached from the unit or fall

onto the floor.

≥Install the unit in such a way that the equipment mounted on it and its cables will not come into contact with anything when the

pan/tilt head swivels, and set definite movement limits.

Page 7 of the Panasonic AW-RC400E user manual — Parts and their function
Seite 7 · Zum Vergrößern klicken
Seite 7

Parts and their function

Panasonic AW-RC400E — Parts and their function diagram (page 7)
Abb. 5 · Parts and their function
Page 8 of the Panasonic AW-RC400E user manual — Rotary head connector panel Pedestal connector panel
Seite 8 · Zum Vergrößern klicken
Seite 8

Parts and their function

@

K

Panasonic AW-RC400E — @ diagram (page 8)
Abb. 6

M

N

B

O

P

Rotary head connector panel Pedestal connector panel

J

1Rotary head This rotates in the horizontal direction.

:Pan/tilt head mounting holes

These four holes are used when installing the pan/tilt head.

3POWER ON/OFF switch When this is set to ON, the unit’s power is turned on; when it is set to OFF, it is turned off.

The prompter is connected to this connector. The maximum current which can be supplied from the DC 12V OUT socket is 2A. When the prompter is connected, the pan/tilt head’s speed is reduced to about one-third.

4AC 100 inlet [AC IN] (AC 3-point inlet) Connect the accessory AC power cable to this inlet.

5Camera mounting base mounting screws M5!20 mm hexagon socket head screws, M5 flat washers (3 of each provided as accessories) These parts are used to secure the camera mounting base to the rotary arm.

87654321 ?>=

Pin layout as seen facing the

6Tally lamp (accessory) This is lit up red by the selected signals.

Panasonic AW-RC400E — Rotary head connector panel Pedestal connector panel diagram (page 8)
Abb. 7 · Rotary head connector panel Pedestal connector panel
Pin No.Signal Name 1– – – 9PROMPTER VIDEO GND 2PROMPTER VIDEO 10– – – 3– – – 11– – – 4DC 12V OUT 12GND 5– – – 13– – – 6– – – 14DETECT 7– – – 15GND 8– – –

7Rotary arm mounting screws M5!20 mm hexagon socket head screws, M5 flat washers (4 of each provided as accessories) These parts are used to secure the rotary arm to the rotary head.

8Rotary arm This rotates in the vertical direction.

9Camera mounting base Mount the convertible camera on this base.

Show 4 more labels / short text on this page
2Pedestal · ;Bottom panel · <PROMPTER connector · prompter connector
Page 9 of the Panasonic AW-RC400E user manual — C D
Seite 9 · Zum Vergrößern klicken
Seite 9

Parts and their function

END/EXT connector [ND/EXT]

Use this to determine the direction in which the camera is to be mounted.

This is for the control of the ND filter and lens extender of the motorized lens unit. Connect this connector when using a motorized lens unit with ND filter and lens extender functions. The compatible connector is the R03-P6M or R03-PB6M made by Tajimi Electronics Co., Ltd.

>Camera mounting screws (U1/4” 20UNC)

These are used to secure the camera firmly after it has been mounted.

?Side blank panel

ND signal CVCC (+12V)

This is used when the mounting direction of the pedestal connector panel is to be changed.

A F

@SDI IN connector [SDI IN]

B E

Use a coaxial cable to connect this to the SDI OUT connector on the AW-PB504 SDI card or other card installed in the convertible camera.

C D

AENG LENS CONTROL connector

EXT return EXT signal

[ENG LENS CONTROL] Use this when an ENG lens is to be used. An optional connecting cable is required.

(Pin layout as seen from cable end)

BOPTION connector [OPTION]

FTALLY OFF/ON switch [TALLY]

The optional AW-RL400 roll unit is connected here using the cable supplied with the AW-RL400.

When this is set to ON, the tally lamp is lit by the selected signals. When it is set to OFF, the (6) tally lamp will not light even if the selected signals are supplied.

CLENS I/F connector [LENS I/F]

This is used to control the zooming and focusing of the motorized lens unit. Use the motorized lens unit’s remote (zoom/focus) control cable to make the connection.

GCONTROL IN IP/RP connector [IP/RP]

This is the connector for the control of signals of the camera and pan/tilt head. It is connected to the CONTROL OUT TO PAN/TILT connector on the AW-RP400 pan/tilt head controller. Use a 10BASE-T (equivalent to UTP category 5) straight cable for the connecting cable.

DCAMERA I/F connector [CAMERA I/F]

This is used for the control of the convertible camera. Use the camera cable supplied with the AW-PH400 to connect the connector with the REMOTE connector on the camera. Depending on the functions of the optional card, a special camera cable (sold separately) is required.

HVIDEO connector [VIDEO]

This the output connector for the camera’s video signals. It is connected to the Y/VIDEO connector on the AW-RC400 cable compensator or monitor, etc. Use a BNC coaxial cable for the connecting cable.

ICABLE COMP OFF/ON switch [CABLE COMP]

When this is set to ON, signals which have been cable- compensated for the equivalent of 500 meters are output from the VIDEO connector and the Y, Pr and Pb connectors. When this switch is used in conjunction with the AW-RC400 cable compensator, the video cable can be extended up to a maximum of 1000 meters.

=Guide pin · CGND ND return

Page 10 of the Panasonic AW-RC400E user manual — Parts and their function
Seite 10 · Zum Vergrößern klicken
Seite 10

Parts and their function

JY connector [Y]

This is the output connector for the camera’s video signals. It is connected to the Y/VIDEO connector on the AW-RC400 cable compensator or monitor, etc. Use a BNC coaxial cable for the connecting cable. The AW-PB302 RGB card must be installed if the AW-E300, AW-E300A, AW-E600, AW-E800 or AW-E800A convertible camera is to be used.

K1394 connector [1394]

This is used for the control of the convertible camera and pan/tilt head equipped with an IEEE1394 card such as the AW-PB310. Use an IEEE1394 cable for the connecting cable.

LSDI connector [SDI]

This is the output connector for the camera’s video signals. When the AW-PB504 SDI card or other card is inserted in the convertible camera for use, SDI signals can be output. Use a BNC coaxial cable for the connecting cable.

MG/L IN connector [G/L IN]

This is the genlock signal input connector. It is connected to the G/L OUT connector on the AW-RC400 cable compensator or other unit. Use a BNC coaxial cable for the connecting cable.

NPROMPTER IN connector [PROMPTER IN]

The video signals for the prompter are input to this connector. Use a BNC coaxial cable for the connecting cable.

OPb connector [Pb]

This is the output connector for the camera’s video signals. It is connected to the Pb connector on the AW-RC400 cable compensator or monitor, etc. Use a BNC coaxial cable for the connecting cable.

PPr/C connector [Pr/C]

This is the output connector for the camera’s video signals. It is connected to the Pr/C connector on the AW-RC400 cable compensator or monitor, etc. Use a BNC coaxial cable for the connecting cable.

Page 11 of the Panasonic AW-RC400E user manual — For a stand-alone installation
Seite 11 · Zum Vergrößern klicken
Seite 11

Installation (Be sure to ask your dealer to install the unit.)

$ Assembling the pan/tilt head

1Attaching the camera mounting base Attach the camera mounting base to the rotary arm using the three screws. The mounting direction differs depending on the installation method used.

Panasonic AW-RC400E — $ Assembling the pan/tilt head diagram (page 11)
Abb. 8 · $ Assembling the pan/tilt head

2Attaching the rotary arm Attach the rotary arm to the rotary head using the four screws. The mounting direction differs depending on the installation method used.

For a stand-alone installation

Panasonic AW-RC400E — For a stand-alone installation diagram (page 11)
Abb. 9 · For a stand-alone installation
Panasonic AW-RC400E — For a stand-alone installation diagram (page 11)
Abb. 10 · For a stand-alone installation

3Mounting the tally lamp Remove the four screws to remove the top cover. Remove the two screws to remove the blank panel. Mount the tally lamp, and secure it using the screws used to attach the blank panel. Connect the tally lamp’s connector. Attach the top cover, and secure it using the four screws.

≥Tighten up the screws securely to ensure that they will not come

loose during use.

Tally lamp

Page 12 of the Panasonic AW-RC400E user manual — $ Setting the mounting direction switch
Seite 12 · Zum Vergrößern klicken
Seite 12

Installation (Be sure to ask your dealer to install the unit.)

$ Setting the mounting direction switch

Set the switch as follows when the unit is to be installed on the ceiling. (This switch was set to the stand-alone installation position at the factory.)

1 Remove the four screws, and gently remove the pedestal connector panel.

2 Set switch S1 on the PCB inside the pan/tilt head as follows.

For stand-alone installation:

Set S1 to the rear position (T). (Factory setting)

For installation on the ceiling:

Set S1 to the front position (H).

3 Upon completion of the setting, return the pedestal connector panel to its original position, and attach it using the screws. (Take care not to pinch or disconnect the wires.)

Panasonic AW-RC400E — $ Setting the mounting direction switch diagram (page 12)
Abb. 11 · $ Setting the mounting direction switch

≥Be absolutely sure to turn off the power before changing the position of this switch.

Page 13 of the Panasonic AW-RC400E user manual — $ Setting the PCB switches
Seite 13 · Zum Vergrößern klicken
Seite 13

Installation (Be sure to ask your dealer to install the unit.)

$ Setting the PCB switches

The switches on the CONNECTOR PCB will need to be set in accordance with the signals to be transmitted and the equipment to be connected to the pan/tilt head. (The switches are set to support analogue/SDI at the factory.)

IP/IEEE switchIEEE 422/IP switch: 422

≥Web card support

IP/IEEE switchIP 422/IP switch: IP

≥IEEE1394 card support

IP/IEEE switchIEEE 422/IP switch: 422

IP/IEEE switch 422/IP switch

≥Analogue/SDI support

Page 14 of the Panasonic AW-RC400E user manual — $ Changing the mounting position of the pedestal connector panel
Seite 14 · Zum Vergrößern klicken
Seite 14

Installation (Be sure to ask your dealer to install the unit.)

$ Changing the mounting position of the pedestal connector panel

If necessary, the position at which the pedestal connector panel is mounted can be moved to the opposite side of the unit.

Panasonic AW-RC400E — $ Changing the mounting position of the pedestal connector panel diagram (page 14)
Abb. 12 · $ Changing the mounting position of the pedestal con…

Rotary head connector panel

1 Remove the four screws for the pedestal connector panel, and pull out the pedestal connector panel.

2 Disconnect all six connectors of the PCB at the back of the pedestal connector panel.

3 Remove the four screws for the side blank panel, and remove the side blank panel.

4 Move the pedestal connector panel to the opposite side, and re-connect the connectors of the PCB as before.

5 Screw down the pedestal connector panel and side blank panel.

≥Neither the mounting position nor the mounting direction of the rotary head connector panel can be changed.

Pedestal connector panel

Page 15 of the Panasonic AW-RC400E user manual — For a stand-alone installation For installation on the ceiling
Seite 15 · Zum Vergrößern klicken
Seite 15

Installation (Be sure to ask your dealer to install the unit.)

$ Installing the pan/tilt head

When installing the pan/tilt head, follow the instructions below carefully. In order to prevent accidents resulting when the product becomes dislodged or falls down, be absolutely sure to proceed as instructed. Do not install the pan/tilt head on its side since its prescribed operation and performance cannot be ensured.

≥After the pan/tilt head has been installed, mount the camera on it.

≥When installing the pan/tilt head, use the four mounting holes to secure the pan/tilt head firmly.

≥Use the M6 hexagon head bolts (including one short bolt) for installation.

≥Use hexagon head bolts which are longer than the thickness (t) of the mounted member + 25 mm.

≥As shown in the figure, use flat washers, spring washers and hexagon nuts for the hexagon head bolts.

≥Use a wrench of the appropriate size to tighten up the hexagon head bolts.

≥When installing the pan/tilt head on the ceiling, attach the wire together with the bolts, and then anchor them securely to a

rigid part of the ceiling.

≥Use a wire which is strong enough to bear the weight of the entire pan/tilt head (pan/tilt head, camera and lens cable).

≥Install the pan/tilt head in such a way that the equipment and cable attached to it will not make contact with any surrounding

objects when the head is swiveled.

Panasonic AW-RC400E — $ Installing the pan/tilt head diagram (page 15)
Abb. 13 · $ Installing the pan/tilt head

For a stand-alone installation For installation on the ceiling

Panasonic AW-RC400E — For a stand-alone installation For installation on the ceiling diagram (page 15)
Abb. 14 · For a stand-alone installation For installation on t…

❈When installing the pan/tilt head, do not forcibly turn the rotary head or rotary arm manually.

Doing so may result in malfunctioning.

t · t

Page 16 of the Panasonic AW-RC400E user manual — $ Mounting the camera
Seite 16 · Zum Vergrößern klicken
Seite 16

Installation (Be sure to ask your dealer to install the unit.)

$ Mounting the camera

1 Select the positions of the guide pin and camera mounting screws in accordance with the camera and lens to be used, and mount the camera. When mounting the camera on the pan/tilt head, be very careful to ensure that the camera does not fall off or fall down.

Panasonic AW-RC400E — $ Mounting the camera diagram (page 16)
Abb. 15 · $ Mounting the camera
Panasonic AW-RC400E — $ Mounting the camera diagram (page 16)
Abb. 16 · $ Mounting the camera

Guide pin · Flat washers · Camera mounting screws

Page 17 of the Panasonic AW-RC400E user manual — For a stand-alone installation For installation on the ceiling
Seite 17 · Zum Vergrößern klicken
Seite 17

Installation (Be sure to ask your dealer to install the unit.)

$ Attaching the chain

When mounting the AW-E750 camera

1 Use the chain mounting screw (M4!8 mm with flat washer and spring washer) to attach one end of the chain to the pan/tilt head’s arm.

2 Mount the mounting spacer on the top panel of the camera.

3 Use the chain mounting screw (M4!6 mm with flat washer and spring washer) to attach the other end of the chain to the screw hole of the mounting spacer.

When mounting the AW-E350 or AW-E650 camera

1 Use the chain mounting screw (M4!8 mm with flat washer and spring washer) to attach one end of the chain to the pan/tilt head’s arm.

2 Use the chain mounting screw (M4!6 mm with flat washer and spring washer) to attach the other end of the chain to the screw hole of the top panel of the camera.

For a stand-alone installation For installation on the ceiling

≥ CameraAW-E750 ≥ Camera: AW-E750

M4!8 mm chain mounting screw with flat washer and spring washer

M4!6 mm chain mounting screw with flat washer and spring washer M4!6 mm chain mounting screw with flat washer and spring washer

Panasonic AW-RC400E — For a stand-alone installation For installation on the ceiling diagram (page 17)
Abb. 17 · For a stand-alone installation For installation on t…
Panasonic AW-RC400E — For a stand-alone installation For installation on the ceiling diagram (page 17)
Abb. 18 · For a stand-alone installation For installation on t…

M4!8 mm chain mounting screw with flat washer and spring washer

❈Be absolutely sure to tighten up the mounting spacer and screws securely using a tool such as a screwdriver.

Arm

Page 18 of the Panasonic AW-RC400E user manual — $ Replacing the gear
Seite 18 · Zum Vergrößern klicken
Seite 18

Replacing the consumable parts

$ Replacing the battery

The battery has a service life of approximately 5 years. The unit stores the preset positions, limiters and other data in its memory. This data is retained even when the power is turned off, but if the internal battery has reached the end of its service life, the data will be lost when the power is turned off. Replace a battery that has lost its charge with a new one. (Battery used: CR2032 manganese dioxide-lithium battery)

Panasonic AW-RC400E — $ Replacing the battery diagram (page 18)
Abb. 19 · $ Replacing the battery

$ How to remove the battery

1 Remove the four screws, and remove the pedestal connector panel. 2 Push the battery in the direction indicated by the arrow in the figure, and slide it out. 3 With the battery slid out, raise it from underneath the part with the arrow. 4 After disengaging the part with the arrow from the battery holder, pull the battery out toward yourself.

Replace the lithium battery here.

$ How to install the battery

1 Make the “+” side of the new battery to the front side, and insert its end into the battery holder from the direction of the arrow. 2 Push the battery into the holder while pushing the battery in the direction of the arrow. 3 Attach the pedestal connector panel using the four screws.

$ Replacing the motor

Replace the motor when it ceases to operate properly. For details on the motor replacement, consult your dealer.

$ Replacing the belt

Replace the belt when the preset stop accuracy has deteriorated. For details on the belt replacement, consult your dealer.

$ Replacing the gear

Replace the gear when the preset stop accuracy has deteriorated. For details on the gear replacement, consult your dealer.

The motor, gear and belt are consumables.

They need to be replaced at periodic intervals.

Pedestal connector panel

Page 19 of the Panasonic AW-RC400E user manual — Specifications
Seite 19 · Zum Vergrößern klicken
Seite 19

Specifications

Supply voltageAC 240V, 50/60 Hz
Power consumption145W

1 indicates safety information.

Genlock inputBNC Black burst or composite video signal Prompter input
(PROMPTER IN)BNC Through output to PROMPTER connector Prompter output
(PROMPTER OUT)D-SUB 15-pin

VIDEO: BNC, 75-ohm output, 1 Vp-p Connecting cable: 5C-2V, max. 1000 meters Y, Pr/C, Pb: Y/C

Y: 1 Vp-p/75 ohms C: 0.285Vp-p/75 ohms (burst) Component video:

Y: 1 Vp-p/75 ohms Pr: 0.7Vp-p/75 ohms Pb: 0.7Vp-p/75 ohms Connecting cable: 5C-2V, max. 1000 meters SDI: BNC

Camera, pan/tilt head control: RJ45, RS-485, pan/tilt head control signal output RP/IP Connecting cable: 10BASE-T straight cable (equivalent to UTP category 5), max. 500 meters

Functions/performanceMaximum load-bearing capacity: 8 kg Tilt range: 190 degrees (approx. ±95 degrees)

The tilt range is subject to restrictions depending on the cable and lens of camera to be mounted on pan/tilt head. Pan range: 400 degrees (approx. ±200 degrees) Maximum operating speed: 90 degrees/sec.

(Maximum operating speed with prompter mounted: 30 degrees/sec.) Repeatability: ±30” Noise level: Less than NC30 (at less than 30 degrees/sec.)

Ambient operating temperature: 0°C to +45°C Storage temperature: –20°C to +60°C Ambient operating humidity: 30% to 90% (no condensation) Dimensions (W!H!D):!! mm Weight: Approx. ?? kg Finish: AV ivory paint (colour resembling Munsell 7.9Y6.8/0.8)

Camera video output

Page 20 of the Panasonic AW-RC400E user manual — Accessories
Seite 20 · Zum Vergrößern klicken
Seite 20

Introduction

≥This pan/tilt head controller enables up to five AW-PH400

NOTE

indoor pan/tilt heads to be controlled.

≥The AW-RP400 cannot be used to control the model

≥By connecting the AW-CB400 remote operation panel or

AW-PH300, AW-PH300A, AW-PH350, AW-PH500 or AW-PH600 pan/tilt heads.

WV-CB700A remote control box to the controller, the convertible cameras mounted on the pan/tilt heads can be controlled at the same time.

≥Before using the controller, the movement range

(limiters) of the pan/tilt head system must be set without fail.

≥By installing an additional controller, two of the five units

in the pan/tilt head system can be controlled at the same time.

≥When the AW-PH400 controller is to be discarded at

the end of its service life, ask a specialized contractor to dispose of it properly in order to protect the environment.

≥Up to ten tracing memories can be accommodated.

≥Up to 50 preset memories can be set.

≥The connection distance between the controller and

pan/tilt head system can be extended up to a maximum of 500 meters.

Accessories

Zoom switch 1

Plug (D-SUB 15-pin) for tally/INCOM system 1 set

Rack-mounting adaptors 2

Mounting screws (M4!8 mm) 4

Page 21 of the Panasonic AW-RC400E user manual — NOTE
Seite 21 · Zum Vergrößern klicken
Seite 21

Parts and their function

$ Front panel

1 I H G E D C B A @ ? > = < ; F

J

K

:

1EXT CONT [M/S] switch This switch is normally kept at the [M] (master) position. When an additional AW-RP400 controller has been installed, set the EXT CONT switch on the additional unit to [S] (slave). If no additional AW-RP400 controller is going to be installed, the EXT CONT switch on this controller must be kept at the [M] (master) position without fail.

NOTE

When an additional AW-RP400 controller is installed and used, it will not be possible to exercise control from the slave controller unless the OPERATE switches not only on the slave controller but on the master controller as well are set to [ON]. Remember to set the OPERATE switch on the slave controller to [ON] first before setting the OPERATE switch on the master controller to [ON].

2OPERATE lamp This lights up green when the (3) OPERATE switch is at ON. It goes off when the switch is set to OFF.

4INCOM jack The INCOM (inter-communication) headset is connected here.

3OPERATE [OFF/ON] switch When this switch is set to [ON], the power supply from the connected pan/tilt heads to the cameras is turned on, and system control is enabled. When it is set to [OFF], the power supply from the connected pan/tilt heads to the cameras is turned off.

5LEVEL control Use this to adjust the volume of the headset’s receiver.

6CALL button When this button is pressed, the buzzer of the connected controller sounds, and the CALL button lamp lights.

Page 22 of the Panasonic AW-RC400E user manual — Parts and their function
Seite 22 · Zum Vergrößern klicken
Seite 22

Parts and their function

7IRIS [AUTO/MANU/LOCK] button Use this to select the method for adjusting the lens iris of the cameras in the currently selected pan/tilt head system. Each time it is pressed, the setting is switched in the sequence of AUTO, MANU and LOCK. AUTO: The cameras automatically adjust the lens iris in

Sixteen LEDs are used to display the position of the pan/tilt head in the horizontal rotational direction for 200 degrees to the left or right. When the pan/tilt head is rotated to the right by more than 180 degrees up to 200 degrees, the 180-degree LED flashes, and LEDs on its left light. Conversely, when the pan/tilt head is rotated to the left by more than 180 degrees up to 200 degrees, the 180- degree LED flashes, and LEDs on its right light.

accordance with the light quantity, and the IRIS button lamp lights. MANU: The lens iris is adjusted manually using the IRIS

dial. At this setting, the IRIS button lamp is off. LOCK: The lens iris is locked at the manually adjusted

setting. It does not move even when the (9) IRIS dial is turned. In this status, the IRIS button lamp flashes slowly.

90° to the left 90° to the right

While MANU or LOCK is selected, the IRIS button lamp starts flashing quickly when the IRIS dial is turned: this indicates that the lens iris cannot be controlled even when the (9) IRIS dial is turned.

180° to the left or right

≥The IRIS button on the controller does not work when

the WV-CB700A remote control box is connected to the controller. Select AUTO or MANU using the IRIS [AUTO/MAN] button on the WV-CB700A.

The position of the lens iris in the currently selected pan/tilt head system is indicated by a 6-step display (CLOSE > OPEN).

8SD CARD slot This slot is where the SD memory cards are inserted. The pan/tilt head and camera setting can be stored on these cards.

The position of the lens zoom in the currently selected pan/tilt head system is indicated by a 6-step display (WIDE > TELE).

9IRIS dial The lens iris can be adjusted by turning this dial while the (7) IRIS [AUTO/MANU/LOCK] button is set to MANU. The iris is opened by turning the dial clockwise and stopped down by turning it counterclockwise.

The position of the lens focus in the currently selected pan/tilt head system is indicated by a 6-step display (NEAR > FAR).

≥The IRIS dial on the controller does not work when the

WV-CB700A remote control box is connected to the controller. Adjust the iris using the IRIS control on the WV-CB700A.

?OPTION switches [A to H]

The “NOT USE”, “LAMP”, “DEFROSTER”, “WIPER”, “HEATER/FAN”, “AF”, “ND”, “OPTION” and “EXTENDER” functions can be allocated to OPTION switches A to H by menu settings.

:ZOOM lever/FOCUS dial

Use the ZOOM lever to adjust the lens zoom. The TELE (telephoto) and WIDE (wide angle) settings are established by the direction in which the lever is tilted; the zooming speed is adjusted by the angle to which the lever is tilted. The lens is focused using the FOCUS dial on the top of the lever.

Press this to move the pan/tilt head and roll unit to the home position.

ALCD CONTRAST control

Use this to adjust the contrast of the LCD panel.

Show 6 more labels / short text on this page
;PAN indicator · 0o · <IRIS indicator · =ZOOM indicator · >FOCUS indicator · @HOME button
Page 23 of the Panasonic AW-RC400E user manual — J TRACING MEMORY [START POINT, STOP,
Seite 23 · Zum Vergrößern klicken
Seite 23

Parts and their function

HCONTROL SELECT buttons [1] to [5]

When one of the (C) PRESET MEMORY selection buttons [1] to [50] is pressed while holding down the MEMORY button, the settings of the pan/tilt head system can be registered in that PRESET MEMORY selection button. The MEMORY button flashes if the pan/tilt head selected by the (H) CONTROL SELECT button is not connected or its power has not been turned on.

The (R) CONTROL OUT TO PAN/TILT HEAD [P1] to [P5] connectors on the rear panel can be selected by pressing buttons [1] to [5]. The button lamps corresponding to the numbers of the buttons selected light, and the selected pan/tilt head systems can be controlled. When the (S) MONI SEL OUT connector on this controller is connected to the MONI SEL IN connector on the AW-RC400 cable compensator, the images of the camera connected to the MONI1 or MONI2 connector on the AW-RC400 can be output.

CPRESET MEMORY selection buttons [1] to [50]

Use these buttons to call the settings registered in them. When data has been registered in the tracing memories, the recording/play time displays appear.

≥When two AW-RP400 controllers are connected, the

combination of the controllers which select the monitor output can be set on the menu.

The current setting statuses are displayed on this panel.

IANOTHER CONTROL lamps [1] to [5]

When another AW-RP400 controller is connected, these lamps indicate the numbers of the pan/tilt head systems selected by the additional AW-RP400 controller.

Hold down this button for two or more seconds to turn the setting menu ON or OFF. When (C) PRESET MEMORY selection button [5], [10], [15], [20], [25] or [30] is pressed while holding down the MENU/LIMIT button, ON/OFF control over the limiters can be exercised.

J TRACING MEMORY [START POINT, STOP,

RESTORE, RESET, 1 to 10] buttons Use these for the tracing memory operations. For details on operation, refer to the tracing memory section.

This is used for the setting menu operations.

[ZOOM/FOCUS/PAN/TILT/ROTATION] These enable the pan/tilt head, lens and roll unit control speeds to be adjusted. By turning these controls as far as they will go in the counterclockwise direction, operation of the pan/tilt heads and lenses can be prevented even when control is exercised using the joystick, etc.

GTALLY lamps [1] to [5]

When tally signals are supplied to the (O) TALLY/INCOM connectors [1] to [5] on the rear panel, the lamps with the numbers corresponding to those connectors light up. When tally signals are supplied to the tally connectors [1] to [5] of the AW-CB400 remote operation panel, if this panel is connected to the pan/tilt head controller, the lamps with the numbers corresponding to those connectors also light up.

LPAN/TILT lever/ROTATION control switch

Use these to adjust the direction of the pan/tilt heads. When the lever is tilted to the left or right, the pan/tilt heads move toward the left or right; when it is tilted up or down, they move upward or downward. The movement speed can be adjusted by the angle to which the lever is tilted. Further, the angle of the AW-RL400 roll unit can be adjusted using the ROTATION control switch on the front of the lever. By pressing the top part of the ROTATION control switch, the roll unit rotates clockwise; by pressing the bottom part, it rotates counterclockwise. The speed of the rotation changes in accordance with the amount of pressure applied.

Show 5 more labels / short text on this page
BMEMORY button · DLCD panel · EMENU/LIMIT button · FCONT dial · KSPEED controls
Page 24 of the Panasonic AW-RC400E user manual — EXT CONT
Seite 24 · Zum Vergrößern klicken
Seite 24

Parts and their function

$ Rear panel

M N O P Q

U T S R

MEXT CONT IN/OUT connectors

When an additional AW-RP400 controller is to be provided, connect these connectors on the two AW-RP400 controllers using a 10BASE-T (equivalent to UTP category 5) straight cable.

Connect this to the TALLY/INCOM connector on the video switcher or other unit. When the TALLY input connector is set to the GND level, the TALLY lamp on the controller or pan/tilt head lights. Do not apply a voltage in excess of 5V to this connector.

87654321 ?>=

Pin layout as seen from the

EXT CONT

EXT CONT

back panel of AW-RP400

IN

IN

Pin No. Signal name 1 TALLY1 9 TALLY2 2 TALLY3 10 TALLY4 3 TALLY5 11 TALLY GND 4 – – – 12 – – – 5 – – – 13 – – – 6 MIC+ 14 MIC– 7 INCOM GND 15 SP– 8 SP+

10BASE-T 10BASE-T straight cable

EXT CONT

EXT CONT

OUT

OUT

NCAMERA CONTROL IN FROM RCB [P1] to [P5]

connectors Connect the WV-CB700A remote control boxes to these connectors. The cameras installed on the pan/tilt heads corresponding to the ports where the WV-CB700A boxes have been connected can then be controlled. When even one WV-CB700A box is connected, the cameras cannot be controlled from the AW-CB400 remote operation panel even if the AW-CB400 is connected.

Use the accessory plug (D-SUB 15-pin) to connect the tally/INCOM signals to the system. Connect a 4-wire INCOM system to the INCOM connector. When an additional controller has been provided or when the AW-CB400 remote operation panel has been connected, the tally or INCOM function of all the units will take effect if tally or INCOM signals are connected to one of the units.

OTALLY/INCOM connector · Master controller AW-RP400 · Slave controller AW-RP400

Page 25 of the Panasonic AW-RC400E user manual — Parts and their function
Seite 25 · Zum Vergrößern klicken
Seite 25

Parts and their function

Connect an external unit to this connector to control the pan/tilt head systems from a PC or other external unit. Connect the connector to the PC using the AW-CA50T9 RS-232C cable.

QDC 12V IN socket

Connect the AW-PS505 AC adaptor (sold separately) to this socket.

RCONTROL OUT TO PAN/TILT HEAD [P1] to [P5]

connectors Connect these connectors to the IP/RP connectors on the AW-PH400 indoor pan/tilt heads using 10BASE-T (equivalent to UTP category 5) straight cables. The cables can be extended up to a maximum of 500 meters.

SMONI SEL OUT connector

Connect this connector to the MONI SEL OUT connector on the AW-RC400 cable compensator using a 10BASE-T (equivalent to UTP category 5) straight cable. The images of the camera selected by the controller can now be output from the MONITOR1 or MONITOR2 connector on the AW-RC400.

TCAMERA CONTROL IN FROM RCP connector

Connect the AW-CB400 remote operation panel to this connector using the connecting cable packed with the AW-CB400. The cameras installed on the pan/tilt heads can now be controlled from the AW-CB400.

Connect this terminal to ground.

PREMOTE connector · UGround terminal

Page 26 of the Panasonic AW-RC400E user manual — DIRECTION
Seite 26 · Zum Vergrößern klicken
Seite 26

Menu settings

$ Operation method

1 The menu setting items are displayed when the MENU/LIMIT switch is held down for two or more seconds.

AW-RP400

PAN/TILT CONTROLLER

2 If nothing appears on the bottom line of the LCD display, turn the CONT dial to select a menu item.

PRIORITY

3 When the CONT dial is pressed, what has been set appears on the bottom line. If more than one setting is involved in the menu item, the settings on the bottom line are switched each time the dial is pressed.

DIRECTION SET

DIRECTION

PAN NORMAL

4 When a setting is displayed, the setting can be changed by turning the CONT dial.

DIRECTION

TILT NORMAL

5 Press the CONT dial successively: all the detailed settings come to an end, and the display on the bottom line is cleared, enabling another menu item to be selected.

DIRECTION

TILT REVERSE

6 To exit the setting menu, hold down the MENU/LIMIT switch for two or more seconds. Even when a setting is displayed on the bottom line of the LCD display, the menu is exited when the MENU/LIMIT switch is held down for two or more seconds.

DIRECTION

AW-RP400

PAN/TILT CONTROLLER

Show 7 more labels / short text on this page
; · ; · ; · ; · ; · ; · ;
Page 27 of the Panasonic AW-RC400E user manual — OPERATE STOP, RUN STOP
Seite 27 · Zum Vergrößern klicken
Seite 27

Menu settings

$ List of menu items and settings

Menu item Setting Description Initial value

PRIORITY MASTER, SLAVE MASTER

DIRECTION PAN

TILT

ZOOM NORMAL, REVERSE NORMAL FOCUS

IRIS

ROTATION

SPEED WITH ZOOM POS. OFF, 1, 2, 3 OFF

MEMORY LENGTH 60s, 120s, 300s, 600s 60s

PRESET SPEED 1 to 25 25

IRIS CONTROL BOTH, RP400, CB400 BOTH

ROTATION SWITCH ROTATION, FOCUS, ZOOM, IRIS ROTATION

OPTION SWITCH A

B

C NOT USE, LAMP, EFROSTER, WIPER, D HEATER/FAN, AF, ND, OPTION, NOT USE E EXTENDER F

G

H

CONTROL SELECT MODE INTERLOCK, UN-INTERLOCK INTERLOCK

MONITOR2 SELECT (When the controller CB400, SLAVE CB400

(When the controller RP400, CB400 RP400

BUZZER OFF, ON ON

AUTO RUN START No. 1 to 50 1

END No. 1 to 50 50

INTERVAL 1s to 30s 1s

OPERATE STOP, RUN STOP

SD CARD STORE, LOAD – – –

PRIORITY (MASTER/SLAVE)

When two AW-RP400 pan/tilt head controllers have been connected, the priority of the CONTROL SELECT buttons is to be set. When MASTER is selected as the setting, the master AW-RP400 has priority; when SLAVE is selected, the slave AW-RP400 has priority. If the AW-RP400 controller with a high priority has selected the pan/tilt heads, which were selected by the AW-RP400 controller with a low priority, the CONTROL SELECT button lamps on the AW-RP400 controller with the low priority start flashing to indicate that the control rights have been ceded to the other controller. This setting is performed using the master AW-RP400 controller.

is the master) · is the slave)

Page 28 of the Panasonic AW-RC400E user manual — ROTATION SWITCH setting (ROTATION/FOCUS/ZOOM/IRIS)
Seite 28 · Zum Vergrößern klicken
Seite 28

Menu settings

DIRECTION settings (PAN, TILT, ZOOM, FOCUS, IRIS, ROTATION NORMAL/REVERSE)

When the lever or dial is operated, the DIRECTION menu item enables the operational direction of PAN, TILT, ZOOM, FOCUS, IRIS or ROTATION to be set as the user desires.

PAN: When NORMAL is selected, the pan/tilt head moves toward the left when the PAN/TILT lever is tilted to the LEFT and toward the right when it is tilted to the RIGHT. When REVERSE is selected, the head moves in the opposite direction.

TILT: When NORMAL is selected, the pan/tilt head moves upward when the PAN/TILT lever is tilted toward UP and down when it is tilted toward DOWN. When REVERSE is selected, the head moves in the opposite direction.

ZOOM: When NORMAL is selected, the lens zoom moves toward the telephoto end when the ZOOM lever is tilted toward TELE and toward the wide-angle end when it is tilted toward WIDE. When REVERSE is selected, the zoom moves in the opposite direction.

FOCUS: When NORMAL is selected, the lens focus moves toward FAR when the FOCUS dial is turned clockwise and toward NEAR when it is turned counterclockwise. When REVERSE is selected, the lens focus moves in the opposite direction.

IRIS: When NORMAL is selected, the lens iris moves toward open when the IRIS dial is turned clockwise and toward closed when it is turned counterclockwise. When REVERSE is selected, the lens iris moves in the opposite direction.

ROTATION: When NORMAL is selected, the pan/tilt head moves clockwise when the top of the ROTATION control

switch is pressed and counterclockwise when the bottom is pressed. When REVERSE is selected, the head moves in the opposite direction.

SPEED WITH ZOOM POS. setting (OFF/1/2/3)

At the OFF setting, the pan and tilt speed does not change in accordance with the zoom position. At the 1, 2 or 3 setting, the panning and tilting of the pan/tilt head slows down as the zoom approaches the telephoto end, making it easier to adjust the pan or tilt position even at the telephoto end. The higher the number selected for the setting, the slower the pan and tilt speed at the telephoto end, and the easier it is to adjust the position using a zoom lens with a high magnification rate.

PRESET SPEED setting (1 to 25)

During preset memory data play, this menu item enables the movement speed to the preset positions to be set to one of 25 steps. The higher the setting, the faster the movement speed to the preset positions; conversely, the lower the setting, the slower the movement speed.

IRIS CONTROL setting (BOTH/RP400/CB400)

When the AW-CB400 remote operation panel has been connected to the AW-RP400 controller, this menu item is used to set which controller is to be used to adjust the lens iris. At the BOTH setting, the lens iris can be controlled from both the AW-RP400 and AW-CB400. At the RP400 setting, it can be controlled only from the AW-RP400; similarly, at the CB400 setting, it can be controlled only from the AW-CB400.

ROTATION SWITCH setting (ROTATION/FOCUS/ZOOM/IRIS)

This menu item enables ROTATION, FOCUS, ZOOM or IRIS to be selected as the function to be controlled by the ROTATION switch.

Page 29 of the Panasonic AW-RC400E user manual — CONTROL SELECT MODE setting (INTERLOCK/UN-INTERLOCK)
Seite 29 · Zum Vergrößern klicken
Seite 29

Menu settings

OPTION SWITCH A to H settings (NOT USE / DEFROSTER / WIPER / HEATER/FAN / AUTO FOCUS / ND / OPTION / EXTENDER)

The following functions can be allocated to OPTION buttons A to H. Different functions can be allocated for different pan/tilt heads.

NOT USE: The button is disabled.

DEFROSTER: This controls the ON and OFF states of the defroster function when using a pan/tilt head system

equipped with this function. Each time the button is pressed, ON is switched to OFF or vice versa. When the defroster function is ON, the lamp of the button to which this function has been allocated is lit; when it is OFF, the lamp is off.

WIPER: This controls the ON and OFF states of the wiper function when using a pan/tilt head system equipped with this function. Each time the button is pressed, ON is switched to OFF or vice versa. When the wiper function is ON, the lamp of the button to which this function has been allocated is lit; when it is OFF, the lamp is off.

HEATER/FAN: This controls the ON and OFF states of the heater/fan function when using a pan/tilt head system

equipped with this function. Each time the button is pressed, ON is switched to OFF or vice versa. When the heater/fan function is ON, the lamp of the button to which this function has been allocated is lit; when it is OFF, the lamp is off.

OPTION: This controls the short-circuit and open-circuit states of the AC adaptor’s OPTION CONTROL OUT connector when using an AC adaptor for a pan/tilt head system equipped with the OPTION switch control function. Each time the button is pressed, short circuit is switched to open circuit or vice versa. When short-circuited, the lamp of the button to which this function has been allocated is lit; when open- circuited, the lamp is off.

ND: This controls the ON and OFF states of the ND filter when using a lens equipped with an ND filter. Each time the button is pressed, ON is switched to OFF or vice versa. When the ND filter is ON, the lamp of the button to which this function has been allocated is lit; when it is OFF, the lamp is off.

EXTENDER: This controls the ON and OFF states of the extender when using a lens equipped with an extender. Each time the button is pressed, ON is switched to OFF or vice versa. When the extender is ON, the lamp of the button to which this function has been allocated is lit; when it is OFF, the lamp is off.

AF: This controls the ON and OFF states of the auto focus function when using a lens equipped with this function. Each time the button is pressed, ON is switched to OFF or vice versa. When the auto focus function is ON, the lamp of the button to which this function has been allocated is lit; when it is OFF, the lamp is off.

MEMORY LENGTH setting (60s/120s/300s/600s)

This menu item is used to set the tracing memory data recording time and the number of memories.

60s : 60 sec. ! 10 memories 120s : 120 sec. ! 5 memories 300s : 300 sec. ! 2 memories 600s : 600 sec. ! 1 memory

≥When data has already been registered in a tracing memory, the setting for the recording time and number of memories

cannot be changed. To reset a setting, delete the registered data in the tracing memory first.

CONTROL SELECT MODE setting (INTERLOCK/UN-INTERLOCK)

This menu item is for selecting the method used to select the pan/tilt head and camera when the AW-CB400 remote operation panel has been connected to the AW-RP400 controller.

INTERLOCK: When the pan/tilt head and camera system are selected by the AW-RP400 or AW-CB400, the same system is selected by the other unit as well.

UN-INTERLOCK: A different pan/tilt head and camera system can be selected by the AW-RP400 and AW-CB400.

Page 30 of the Panasonic AW-RC400E user manual — SD CARD setting
Seite 30 · Zum Vergrößern klicken
Seite 30

Menu settings

MONITOR SELECT setting

This menu item is used to select the controller used to switch the images of the AW-RC400’s MONITOR2 output when the AW-CB400 remote operation panel and a second AW-RP400 have been connected to this AW-RP400 controller and the AW-RC400 cable compensator is used. By setting the master AW-RP400 and slave AW-RP400, the camera images which have been selected by the controller given in the table below are output as the AW-RC400’s monitor output.

AW-RP400 menu setting AW-RC400

Master unit Slave unit MONITOR1 MONITOR2

MON2 = CB400 MONITOR2 = setting disabled Master RP400 Master CB400

MON2 = SLAVE MONITOR2 = RP400 Master RP400 Slave RP400

MONITOR2 = CB400 Master RP400 Slave CB400

When the cable compensator has been connected to the slave AW-RP400, the images selected by the slave AW-RP400 are output to MONITOR1 on the AW-RP400 and the images selected by the slave AW-CB400 are output to MONITOR2 regardless of this setting.

BUZZER setting (OFF/ON)

This menu item is used to select ON or OFF for the buzzer inside the controller. The buzzer does not sound at the OFF setting. The buzzer sounds when the CALL button has been pressed or when a tracing memory operation (record, play or change) is started, suspended or ended.

AUTO RUN setting (START No., END No., INTERVAL)

This menu item enables the presets of the pan/tilt head to be repeated automatically.

START No. (1 to 50): This sets the first number of the preset to be repeated.

END No. (1 to 50): This sets the last number of the preset to be repeated.

INTERVAL (1s to 30s): This sets the stop time at the preset position. Up to 30 seconds can be set in 1-second increments for the stop time.

OPERATE (STOP/RUN): When RUN is selected, the presets from the START No. to STOP No. are played repeatedly;

when STOP is selected, operation stops. When the PAN/TILT lever is operated, STOP is selected automatically, and operation stops.

SD CARD setting

The menu setting data of this controller, the preset memory data of the pan/tilt heads and the setting data of the cameras can be stored on SD memory cards. If the MENU button is pressed while STORE is displayed, the setting data is stored on the SD memory card. If the MENU button is pressed while LOAD is displayed, the data stored on the SD memory card is called, and the settings are loaded into the controller, pan/tilt heads and cameras.

≥The tracing memory data is not stored.

Page 31 of the Panasonic AW-RC400E user manual — AW-RP400
Seite 31 · Zum Vergrößern klicken
Seite 31

Example of rack mounting

$ How to mount the AW-RP400 in a rack

1 Use the accessory mounting screws (M4!8 mm) to attach the rack-mounting adaptors.

AW-RP400

Accessory mounting screws (M4!8 mm) 4 pcs

Rack-mounting adaptor

Page 32 of the Panasonic AW-RC400E user manual — $ How to change the direction of the connector panel
Seite 32 · Zum Vergrößern klicken
Seite 32

Example of rack mounting

$ How to change the direction of the connector panel

Screws!5 (bottom panel)

1 Remove the five bottom panel screws, and remove the blank panel.

Remove the blank panel.

Screws!5 (rear panel)

2 Remove the five rear panel screws, and remove the connector panel.

Remove the connector panel.

Screws!5 (bottom panel)

3 Secure the connector panel to the bottom panel using the screws.

Screws!5 (rear panel)

4 Secure the blank panel to the rear panel using the screws.

Connector panel · Blank panel

Page 33 of the Panasonic AW-RC400E user manual — $ How to replace the zoom switch
Seite 33 · Zum Vergrößern klicken
Seite 33

Example of rack mounting

$ How to replace the zoom switch

Panasonic AW-RC400E — $ How to replace the zoom switch diagram (page 33)
Abb. 20 · $ How to replace the zoom switch

1 Remove the four screws that secure the zoom lever.

Panasonic AW-RC400E — $ How to replace the zoom switch diagram (page 33)
Abb. 21 · $ How to replace the zoom switch

2 Pull out the zoom lever, disconnect the two cables from the circuit board inside, and remove the zoom lever.

Panasonic AW-RC400E — $ How to replace the zoom switch diagram (page 33)
Abb. 22 · $ How to replace the zoom switch

3 Plug the two cables extending from the zoom switch into the connectors on the circuit board inside.

4 Secure the zoom switch using the four screws.

Screws!4

Page 34 of the Panasonic AW-RC400E user manual — Replacing the consumable parts
Seite 34 · Zum Vergrößern klicken
Seite 34

Replacing the consumable parts

The joysticks and zoom switch are consumables.

Replace them if they are not working properly.

Ask your dealer to do the replacement work.

Page 35 of the Panasonic AW-RC400E user manual — CONTROL OUT TO
Seite 35 · Zum Vergrößern klicken
Seite 35

Specifications

Supply voltageDC 10.8V to 16V
Power consumptionApprox. 11W

1 indicates safety information.

DC 12V IN: XLR, 4 pins CONTROL IN FROM ROP: D-SUB 15-pin, cable supplied with AW-CB400 remote operation panel CONTROL IN FROM RCB: 10-pin round connector, cable supplied with WV-CB700A EXT CONT IN: RJ45, additional AW-RP400 control signal input; 10BASE-T straight cable (UTP category 5), max. 500 meters REMOTE: 50-pin D-SUB connector, external control input, AW-CA50T9

CONTROL OUT TO

PAN/TILT HEAD: RJ45, pan/tilt head control signal output; 10BASE-T straight cable (UTP category 5), max. 500 meters MONI SEL OUT: RJ45, monitor switching signal output; 10BASE-T straight cable (UTP category 5), max. 50 meters EXT CONT OUT: RJ45, additional AW-RP400 control signal output; 10BASE-T straight cable (UTP category 5), max. 500 meters

INCOM (top panel)XLR, 4 pins TALLY/INCOM: D-SUB, 15-pin

TALLY: Contact input (Do not apply a voltage in excess of 5V to this connector.) INCOM: 4-wire system

Switch functions: Master/slave switching, OPERATE control, home position, menu/limit switch, optional function operations, pan/tilt head selection, lens iris AUTO/MANU/LOCK switching, preset memory data operations, tracing memory data operations, call

Adjustment functions: LCD contrast, INCOM level, lens iris, zoom, focus, pan/tilt/rotation, zoom speed, focus speed, pan speed, tilt speed, rotation speed, menu settings

Ambient operating temperature–10°C to +45°C
Storage temperature–20°C to +60°C
Ambient operating humidity30% to 90% (no condensation)

Dimensions (W!H!D): 320!85!266 mm

WeightApprox. ?? kg
FinishColour resembling Munsell 3.5

Input connectors · Output connectors · Input/output connectors

Page 36 of the Panasonic AW-RC400E user manual — Accessories
Seite 36 · Zum Vergrößern klicken
Seite 36

Cable Compensator AW-RC400

Introduction

≥The AW-RC400 is capable of providing cable

NOTE

compensation for analogue composite, analogue Y/C or analogue component signals in five channels up to 500 meters (when the 5C-2V connecting cable or its equivalent is used).

≥Input either sync signals to the sync signal input

connector on the AW-RC400 cable compensator or input video signals to one of the video channels (input composite signals or Y signals with sync to video input connector 1). If neither of these signals is input, the monitor selection will not be controlled.

≥It features a 5us advance function for the sync signals in

order to provide easy support for a system (another cable compensator is required) in which the coaxial cable connected between this AW-RC400 cable compensator and the camera is longer than 500 meters.

≥The AW-RC400 provides cable compensation for the

three Y, Pr and Pb signal channels by means of a single control. This means that the Y, Pr and Pb signals cannot be adjusted separately. In the same way, the Y and C signals cannot be adjusted separately.

≥The AW-RC400 is a cable compensator and, as such,

it does not come with signal conversion functions (for converting component signals into composite signals, for instance).

≥When the cable compensator is to be discarded at the

end of its service life, ask a specialized contractor to dispose of it properly in order to protect the environment.

Accessories

Rack-mounting adaptors 2

Mounting screws (M4!8 mm) 4

Page 37 of the Panasonic AW-RC400E user manual — Cable Compensator AW-RC400
Seite 37 · Zum Vergrößern klicken
Seite 37

Cable Compensator AW-RC400

Parts and their function

1 2 3 45

> = < ? @ A ; : 9 B

Front panel Rear panel

1Power LED This lights up green when the (2) POWER switch is set to ON while a DC 12V voltage is supplied to the (7) DC 12V IN socket.

7DC 12V IN socket This is the power input socket. Connect the AW-PS301 AC adaptor (sold separately) here.

8MONI SEL IN connector Control signals for selecting the video signals output to the MONITOR1 or 2 connector are supplied to this connector. Connect it to the MONI SEL OUT connector on AW-RP400 pan/tilt head controller using a 10BASE-T straight cable (equivalent to UTP category 5). It is then possible to output the video signals of the camera selected by the AW-RP400 or the AW-CB400 remote operation panel which is connected to the AW-RP400, to the MONITOR1 or MONITOR2 connector.

2POWER switch Set this to ON to turn on the cable compensator’s power. Part of the power supply circuitry will still operate even when the power switch is at the OFF position. To turn off the power completely, disconnect the AC adaptor.

3Cable length setting switches [0 to 5] Set these switches according to the length of the coaxial cable connected. [0] is used to provide the minimum amount of cable compensation, and [5] the maximum amount. As a general guideline, set to [1] if the coaxial cable is 100 meters long, and [2] if it is 200 meters long.

9G/L IN connectors The sync signals (black burst signals) are input here. These connectors are automatically terminated internally by a 75-ohm resistance. The top and bottom connectors have the same specifications, and the signals can be connected to either one. The termination is released if BNC cables are connected to both input connectors (when they are used in a loop-through configuration).

4Y LEVEL control Use this to adjust the output level of the cable compensation output signals (video output).

5F RESPONSE control Use this to adjust the amount of cable compensation (frequency response compensation) for the cable compensation output signals.

:G/L OUT connectors [1 to 5]

The genlock signals supplied to the G/L IN connector can be distributed and output to five cameras. Use sync signal outputs 1 to 5 to correspond to video signal channels 1 to 5. The signals of sync signal output connector 1 are supplied to the camera connected to video input connector 1.

6SHORT/LONG selector switch This is normally used at the SHORT position. Set it to LONG if the coaxial cable from the camera is a long one and the camera’s sync adjustment range is insufficient, or if the cable compensator is used as part of a system (another cable compensator is required) in which the coaxial cable (5C-2V or equivalent) connected to the camera is longer than 500 meters.

Page 38 of the Panasonic AW-RC400E user manual — Cable Compensator AW-RC400
Seite 38 · Zum Vergrößern klicken
Seite 38

Cable Compensator AW-RC400

Parts and their function

;MONITOR1, 2 connectors

BAC adaptor storage space

The video signals of the cameras selected by the AW-RP400 pan/tilt head controller or the AW-CB400 remote operation panel which is connected to the AW-RP400 are output from these connectors. The output signals are cable-compensated signals of the same type as the input signals. For instance, if a channel to which composite signals have been input is selected, these composite signals will be cable-compensated and output.

The AC adaptor can be stored here when the ambient temperature in the location where the cable compensator has been installed is under 30°C. Remove the two screws, and remove the storage space cover. Pull out the AW-PS301 AC adaptor, and stow it away while ensuring that the cable is not subjected to stress. Trouble will occur in the AC adaptor if the ambient temperature exceeds 30°C, in which case it should not be stored in the space.

The analogue video signals are input to these connectors. They are terminated internally by a 75-ohm resistance. Either Y (component signals or Y of the Y/C signals with sync) or VIDEO (composite) signals are supplied.

=Pr/C IN connectors [1 to 5]

The analogue video signals are input to these connectors. They are terminated internally by a 75-ohm resistance. Either Pr (R-Y among the component signals) or C (C of the Y/C signals) signals are supplied.

>Pb IN connectors [1 to 5]

The analogue video signals are input to these connectors. They are terminated internally by a 75-ohm resistance. The Pb (B-Y among the component signals) signals are supplied.

?Y/VIDEO OUT connectors [1 to 5]

The analogue video signals are output from these connectors. Cable-compensated Y or VIDEO (composite) signals that are in accordance with the input signals are output. Y signals are output if component Y signals have been input to the Y/VIDEO IN connectors [1 to 5], and composite signals are output if composite signals have been input.

@Pr/C OUT connectors [1 to 5]

The analogue video signals are output from these connectors. Cable-compensated Pr or C signals that are in accordance with the input signals are output. Pr signals are output if Pr signals have been input to the Pr/C IN connectors [1 to 5], and C signals are output if C signals have been input.

APb OUT connectors [1 to 5]

The analogue video signals are output from these connectors. Cable-compensated Pb signals are output if Pb signals have been input to the Pb IN connectors [1 to 5].

Page 39 of the Panasonic AW-RC400E user manual — Cable Compensator AW-RC400
Seite 39 · Zum Vergrößern klicken
Seite 39

Cable Compensator AW-RC400

Example of rack mounting

$ How to mount the AW-RC400 in a rack

Use the accessory rack-mounting adaptors and accessory mounting screws (M4!8 mm) to mount the unit in a rack.

1 Press the POWER switch to turn off the power.

2 Remove four feet on the bottom of the unit.

Remove four feet.

3 Place the rack-mounting adaptors to the both ends of the unit, and fix it using four mounting screws.

POWER switch · Rack-mounting adaptor · Mounting screws

Page 40 of the Panasonic AW-RC400E user manual — Cable Compensator AW-RC400
Seite 40 · Zum Vergrößern klicken
Seite 40

Cable Compensator AW-RC400

Specifications

Supply voltageDC 10.8V to 16V
Power consumptionApprox. 9W

1 indicates safety information.

DC 12V IN: For connecting accessory AC adaptor (AW-PS301) G/L IN: BNC!2, automatically terminated by 75-ohm resistance, loop-through output, black burst VIDEO/Y, Pr/C, Pb: BNC!3 (5 sets), 75-ohm termination

Composite 1 Vp-p Y/C

Y: 1 Vp-p (with sync) C: 0.286V (burst) Component

Y: 1 Vp-p (with sync) Pr, Pb: 0.7Vp-p MONI SEL IN: RJ45 Connecting cable: 10BASE-T straight cable (UTP category 5), max. 50 meters

G/L OUT: BNC!5, 75-ohm output, 5C-2V connecting cable, max. 1000 meters VIDEO/Y, Pr/C, Pb: BNC!3 (5 sets), 75-ohm output

Composite 1 Vp-p Y/C

Y: 1 Vp-p (with sync) C: 0.286V (burst) Component

Y: 1 Vp-p (with sync) Pr, Pb: 0.7Vp-p (Cable compensation adjustment is required) MONITOR OUT1/2: BNC!3 (2 sets), 75-ohm output

Switch and adjustment functionsPower ON/OFF; cable length setting 0/1/2/3/4/5; sync signal setting SHORT/LONG; cable

compensation amount adjustment; video level adjustment

Ambient operating temperature0°C to +40°C
Storage temperature–20°C to +60°C
Ambient operating humidity30% to 90% (no condensation)

Dimensions (W!H!D): 420!250!88 mm

WeightApprox. 3.7 kg
FinishAV ivory paint (colour resembling Munsell 7.9Y6.8/0.8)

Input connectors · Output connectors

Page 41 of the Panasonic AW-RC400E user manual — Cable Compensator AW-RC400
Seite 41 · Zum Vergrößern klicken
Seite 41

Cable Compensator AW-RC400

Page 42 of the Panasonic AW-RC400E user manual — Accessories
Seite 42 · Zum Vergrößern klicken
Seite 42

Roll Unit AW-RL400

Introduction

≥The AW-RL400 roll unit enables a camera to be rotated

NOTE

when it is used in combination with the AW-PH400 indoor pan/tilt head.

≥Since the roll unit causes the camera to rotate, the user

should ensure that all the wiring such as the camera cable and lens cable will not become entangled when the roll unit is operated.

≥When the roll unit is to be discarded at the end of its

service life, ask a specialized contractor to dispose of it properly in order to protect the environment.

Accessories

Pan/tilt head connecting cable 1

Mounting screws (M4!8 mm) 3

Page 43 of the Panasonic AW-RC400E user manual — Roll Unit AW-RL400
Seite 43 · Zum Vergrößern klicken
Seite 43

Roll Unit AW-RL400

Parts and their function

5Roll unit anchoring screw holes This is where the roll unit is secured to the rotary arm of the pan/tilt head.

2Camera mounting screw (U1/4”-20UNC) After mounting the camera, secure it firmly using this screw.

6Pan/tilt head connector Connect this to the OPTION connector on the pan/tilt head using the pan/tilt head connecting cable supplied.

3Camera mounting plate Mount the camera on this plate using the camera mounting screws.

4Camera mounting plate anchoring screws After mounting the camera on the camera mounting plate, anchor it to the roll unit using these screws.

1Rotary ring

Page 44 of the Panasonic AW-RC400E user manual — Roll Unit AW-RL400
Seite 44 · Zum Vergrößern klicken
Seite 44

Roll Unit AW-RL400

Installation

1 Attach the pan/tilt head’s rotary arm to the roll unit using the accessory three screws (M4!8 mm, with flat washers).

2 Attach the rotary arm to the pan/tilt head using the rotary arm mounting screws (M5!20 mm, with flat washers, pan/tilt head accessory).

Roll unit mounting screws

Panasonic AW-RC400E — Roll Unit AW-RL400 diagram (page 44)
Abb. 23 · Roll Unit AW-RL400

3 Loosen the two screws of camera mounting plate which is already installed to the roll unit. Then remove the camera mounting plate.

4 Attach the camera mounting plate (it was removed in step 3) to the camera unit using two camera mounting screws (camera accessory).

Panasonic AW-RC400E — Roll Unit AW-RL400 diagram (page 44)
Abb. 24 · Roll Unit AW-RL400

Roll unit · Camera mounting plate

Page 45 of the Panasonic AW-RC400E user manual — Specifications
Seite 45 · Zum Vergrößern klicken
Seite 45

Roll Unit AW-RL400

Installation

5 Attach the camera mounting plate to the roll unit in a way contrary to the procedure of removing it in step 3.

Camera mounting plate’s screws

Specifications

Supply voltageDC 24V
Power consumptionApprox. 24W

1 indicates safety information.

Pan/tilt head connectorConnected to pan/tilt head using cable supplied

Performance: Maximum load-bearing capability: 4 kg Rotary range: 380 degrees (approx. ±190 degrees) Maximum operating speed: 60 degrees/sec. Repeatability: Less than ±1 degree Noise level: Less than

Ambient operating temperature0°C to +40°C
Storage temperature–20°C to +60°C
Ambient operating humidity30% to 90% (no condensation)

Dimensions (W!H!D): 205!198!260 mm

WeightApprox. 3.9 kg
FinishAV ivory paint (colour resembling Munsell 7.9Y6.8/0.8)
Page 46 of the Panasonic AW-RC400E user manual — Connections
Seite 46 · Zum Vergrößern klicken
Seite 46

Connections

≥Turn off the power of all the equipment before proceeding with the connections.

≥Use the AW-PS505 as the AC adaptor for the AW-RP400 pan/tilt head controller. Use the DC cable supplied

with the AW-PS505 to connect the DC 12V IN socket on the AW-RP400 with the DC 12V OUT socket on the AW-PS505.

≥Connect the AC power cable supplied with the AW-PH400 for the AW-PH400 indoor pan/tilt head.

≥Use the AC adaptor supplied with the AW-RC400 for the AW-RC400 cable compensator.

≥Use 10BASE-T straight cables to connect the IP/RP connectors on the pan/tilt heads with the CONTROL OUT

TO PAN/TILT HEAD (1 to 5) connectors on the AW-RP400. The maximum extension distance is 500 meters when using UTP category 5 cables or their equivalent.

≥Use the camera cables supplied with the pan/tilt head to connect the AW-PH400 to the convertible camera.

Supplied with the pan/tilt head are a cable for the composite/component signals, a cable for IEEE1394 cards and a cable for WEB cards. Select the camera cable that matches the intended application.

≥Connect the iris control cable of the motorized zoom lens to the IRIS connector on the camera, and connect the

zoom/focus cable to the LENS I/F connector on the pan/tilt head.

≥Use either the AW-CB400 remote operation panel or WV-CB700A remote control box for camera control.

The AW-CB400 and WV-CB700A cannot be used together.

≥When using the AW-CB400, use the cable (10 m) supplied with the AW-CB400 to connect the CAMERA

CONTROL IN FROM RCP connector on the AW-RP400 with the I/F CONNECTOR on the AW-CB400. Five cameras can be controlled from the AW-CB400. Power is supplied through this cable from the AW-RP400 to the AW-CB400 so the AC adaptor need not be connected to the AW-CB400.

≥When using the WV-CB700A, use the RCB cables (2 m) supplied with the WV-CB700A to connect the

CAMERA CONTROL IN FROM RCB (1 to 5) connectors on the AW-RP400 with the RCB connectors on the WV-CB700A. Only one camera can be controlled from the WV-CB700A. If there is a multiple number of cameras, one AW-CB700A will be required for each camera. It is also necessary to align the number of the CONTROL OUT TO PAN/TILT HEAD connectors connected to the cameras to be controlled with the CAMERA CONTROL IN FROM RCB connectors used to connect the WV-CB700A.

≥Use the 10BASE-T straight cable to connect the MONI SEL OUT connector on the AW-RP400 with the MONI

SEL IN connector on the AW-RC400. The maximum extension distance is 50 meters when using a UTP category 5 cable or its equivalent. By connecting these MONI SEL connectors, the video signals of the camera selected by the AW-RP400 can be output from the MONITOR1 connector and the video signals of the camera selected by the AW-CB400 can be output from the MONITOR2 connector. When the WV-CB700A is used, MONITOR2 cannot be switched.

≥Use a coaxial cable to connect the AW-RC400 and AW-PH400.

≥Supply the genlock signals from a unit such as a signal generator to the G/L IN connector on the AW-RC400,

and connect the G/L OUT (1 to 5) connectors on the AW-RC400 with the G/L IN connectors on the pan/tilt heads.

≥When using composite signals, connect the VIDEO connectors on the pan/tilt heads and Y/VIDEO connectors

(1 to 5) on the AW-RC400.

≥Also connect the Y/VIDEO OUT connectors on the AW-RC400 to switchers or monitors.

≥When using Y/C signals, connect the Y connectors and Pr/C connectors on the pan/tilt heads to the Y/VIDEO

connectors and Pr/C connectors, respectively, on the AW-RC400. Also connect the Y/VIDEO OUT connectors and Pr/C connectors on the AW-RC400 to switchers or monitors.

≥When using component signals, connect the Y connector, Pr/C connector and Pb connector on the pan/tilt head

to the Y/VIDEO connector, Pr/C connector and Pb connector, respectively, on the cable compensator. Also connect the Y/VIDEO OUT connectors, Pr/C connectors and Pb connectors on the AW-RC400 to switchers or monitors.

Page 47 of the Panasonic AW-RC400E user manual — Connections
Seite 47 · Zum Vergrößern klicken
Seite 47

Connections

Panasonic AW-RC400E — Connections diagram (page 47)
Abb. 25 · Connections

Camera cable supplied with AW-PH400

Cable supplied with AW-CB400 (AW-CB400 power and camera control signals)

Show 6 more labels / short text on this page
Motorized zoom lens · Convertible camera · Video signal output · Genlock signal input · AW-PS301 AC adaptor · Monitor signals 2
Page 48 of the Panasonic AW-RC400E user manual — AW-PH400
Seite 48 · Zum Vergrößern klicken
Seite 48

Example of system configuration

Panasonic AW-RC400E — Example of system configuration diagram (page 48)
Abb. 26 · Example of system configuration

AW-PH400

Show 8 more labels / short text on this page
Convertible camera · Indoor Pan/Tilt Head · Composite video or · component video · signals · To switcher, · monitor · AW-PS301 AC adaptor
Page 49 of the Panasonic AW-RC400E user manual — $ Setting the movement range (limiters) of the AW-PH400 indoor pan/tilt head
Seite 49 · Zum Vergrößern klicken
Seite 49

Operating procedures

$ Turning on the power

1 When using one AW-RP400, set its EXT CONT [M/S] switch to the [M] position.

2 Turn on the power. First set the power switch on the AC adaptor for the AW-RP400 and AC power switch on the AW-PH400 to ON, and then set the OPERATE switch on the AW-RP400 to ON.

$ Setting the movement range (limiters) of the AW-PH400 indoor pan/tilt head

If there are any objects obstructing the movement of the AW-PH400 indoor pan/tilt head in the immediate vicinity, set restrictions on the movement range (limiters: left, right, top and bottom limits of rotation). When the AW-RL400 roll unit is connected to the AW-RP400, set the movement limits (clockwise and counterclockwise limits) of the roll unit as well. Before using these units, set these limits without fail.

≥When it is shipped, the AW-PH400 is set up to be placed on a stand or base. If it is to be suspended from the ceiling, the

mounting direction switch must be set without fail. If this setting is not performed correctly, the directions of the pan/tilt operations will be reversed, and the movement range (limiter) settings of the pan/tilt head will not be stored in the memory properly. For details on the setting methods and related aspects, refer to “Setting the mounting direction switch” in the operating instructions for the AW-PH400.

Now proceed with the settings for the AW-RP400 pan/tilt head controller.

1 Use the CONTROL SELECT buttons to select the pan/tilt head whose movement range (limiters) is to be set.

2 To set the left limit, use the PAN/TILT lever to rotate the pan/tilt head as far as the left limit which is to be set. While holding down the MENU/LIMIT button, press the PRESET MEMORY button [5]. Once the limit is set, the lamp of the PRESET MEMORY button [45] will light. To release the setting, press the PRESET MEMORY button [5] again while holding down the MENU/LIMIT button. Once the setting is released, the lamp of the PRESET MEMORY button [50] will light.

3 To set the right limit, use the PAN/TILT lever to rotate the pan/tilt head as far as the right limit which is to be set. While holding down the MENU/LIMIT button, press the PRESET MEMORY button [10]. Once the limit is set, the lamp of the PRESET MEMORY button [45] will light. To release the setting, press the PRESET MEMORY button [10] again while holding down the MENU/LIMIT button. Once the setting is released, the lamp of the PRESET MEMORY button [50] will light.

4 To set the top limit, use the PAN/TILT lever to rotate the pan/tilt head as far as the top limit which is to be set. While holding down the MENU/LIMIT button, press the PRESET MEMORY button [15]. Once the limit is set, the lamp of the PRESET MEMORY button [45] will light. To release the setting, press the PRESET MEMORY button [15] again while holding down the MENU/LIMIT button. Once the setting is released, the lamp of the PRESET MEMORY button [50] will light.

5 To set the bottom limit, use the PAN/TILT lever to rotate the pan/tilt head as far as the bottom limit which is to be set. While holding down the MENU/LIMIT button, press the PRESET MEMORY button [20]. Once the limit is set, the lamp of the PRESET MEMORY button [45] will light. To release the setting, press the PRESET MEMORY button [20] again while holding down the MENU/LIMIT button. Once the setting is released, the lamp of the PRESET MEMORY button [50] will light.

Page 50 of the Panasonic AW-RC400E user manual — Waveform monitor (composite signals) Waveform monitor (component signals)
Seite 50 · Zum Vergrößern klicken
Seite 50

Operating procedures

6 To set the counterclockwise limit of the roll unit, use the ROTATION switch to rotate the roll unit as far as the limit in the counterclockwise direction which is to be set. While holding down the MENU/LIMIT button, press the PRESET MEMORY button [25]. Once the limit is set, the lamp of the PRESET MEMORY button [45] will light. To release the setting, press the PRESET MEMORY button [25] again while holding down the MENU/LIMIT button. Once the setting is released, the lamp of the PRESET MEMORY button [50] will light.

7 To set the clockwise limit of the roll unit, use the ROTATION switch to rotate the roll unit as far as the limit in the clockwise direction which is to be set. While holding down the MENU/LIMIT button, press the PRESET MEMORY button [30]. Once the limit is set, the lamp of the PRESET MEMORY button [45] will light. To release the setting, press the PRESET MEMORY button [30] again while holding down the MENU/LIMIT button. Once the setting is released, the lamp of the PRESET MEMORY button [50] will light.

$ Providing cable compensation for the cameras

Make these adjustments using the AW-RC400 cable compensator.

1 Connect a waveform monitor to the video output connector on the AW-RC400, and set the signals supplied to the corresponding video input connector to colour bar signals.

2 Set the waveform monitor to the H rate (see figure below), and while monitoring the rise and fall sections of the waveforms, set the cable length setting switch at the point where the undershoot and overshoot are kept to the minimum. At this time, keep the Y LEVEL control and F RESPONSE control at their centre positions.

3 Turn the F RESPONSE control, and adjust in such a way that the undershoot and overshoot of the waveforms in the rise and fall sections are kept to the minimum. If the adjustment range of the control is exceeded, see if another setting can be selected for the cable length setting switch.

4 Next, use the Y LEVEL control to obtain the prescribed video level.

5 With component signals, while observing the Y signal on the waveform monitor in the same way as with the composite signals, use the cable length setting switch, F RESPONSE control and Y LEVEL control to adjust the cable compensation in such a way that the prescribed video signals are obtained.

6 Next, view the Y, Pr and Pb signals in their entirety, and re-adjust the F RESPONSE control and Y LEVEL control in such a way that the optimum cable compensation is provided.

7 With Y/C signals as well, first adjust the Y signal in the same way as with the component signals, view both the Y and C signals, and adjust in such a way that the optimum cable compensation is provided.

IRE

IRE

0 10 20 30 40 50 60 70 80 90 100 +100

0 10 20 30 40 50 60 70 80 90 100

100 IRE (0.714V)

+7.5

—40 —30 —20 —10

—40 —30 —20 —10

Waveform monitor (composite signals) Waveform monitor (component signals)

Show 4 more labels / short text on this page
+77 · 1 V [p-p] · +20 · +20
Page 51 of the Panasonic AW-RC400E user manual — $ Tracing memory settings
Seite 51 · Zum Vergrößern klicken
Seite 51

Operating procedures

$ Genlock adjustments for the respective cameras

For details on the genlock adjustments, refer to the operating instructions of the AW-CB400 remote operation panel or WV-CB700A remote control box.

$ Video adjustments for the cameras

Adjust the total pedestal (black level), white balance, black balance, etc. of the cameras. For details on the camera adjustments, refer to the operating instructions of the AW-CB400 remote operation panel or WV-CB700A remote control box.

$ Tracing memory settings

Perform these settings on the AW-RP400 pan/tilt head controller.

The AW-RP400 comes with a tracing memory function for registering the paths along which the pan/tilt head systems move. Using this function, the data is registered in TRACING MEMORY buttons 1 to 10.

Setting the recording time and number of memories

1 Select the first pan/tilt head system using one of the CONTROL SELECT buttons.

2 Set the recording time in the tracing memory and the number of memories using the TR MEMORY LENGTH menu setting.

60s 60 sec. ! 10 memories (buttons 1 to 10)

120s 120 sec. ! 5 memories (buttons 1 to 5)

300s 300 sec. ! 2 memories (buttons 1, 2)

600s 600 sec. ! 1 memory (button 1)

≥It is not possible to set TR MEMORY LENGTH if data has already been registered in the tracing memory.

Before selecting a different setting, delete the registered data in the tracing memory, and then perform the setting. ≥The recording time and the number of memories cannot be changed in each button in which they are registered.

3 Select the other pan/tilt head systems using the other CONTROL SELECT buttons, and set the recording time and number of memories for each of the pan/tilt head systems.

Registering the tracing memory data

1 Select the pan/tilt head system using one of the CONTROL SELECT buttons. When using the AW-CB400 for camera control, select the same number for the AW-CB400.

2 Set the statuses of the pan/tilt head and camera at the start point in the tracing memory. ≥Decide on the view angle and focus using the PAN, TILT, ZOOM and FOCUS controls. ≥Select auto iris, manual iris or manual lock using the IRIS [AUTO/MANUAL/LOCK] button. ≥If manual iris is selected, adjust the iris using the IRIS dial. ≥Adjust the black level, black balance and white balance using the camera controller.

MEMORY LENGTH Setting

Page 52 of the Panasonic AW-RC400E user manual — Operating procedures
Seite 52 · Zum Vergrößern klicken
Seite 52

Operating procedures

3 Press the START POINT button. The lamps of the buttons among TRACING MEMORY buttons 1 to 10 where data can be registered now light. ≥The lamps of the buttons with numbers exceeding the number of memories set by the TR MEMORY LENGTH menu

setting do not light. ≥If the lamp of any button among the number of memories in which data can be set is off, it means that data has already

been registered in the button. When registering data in such a button, delete the existing data in its memory first.

4 Press the number of the button in which the data is to be registered. Only the lamp of the button pressed now lights, and the pan/tilt head position and camera settings prevailing at this time are recorded as the start position of the tracing memory. ≥When the PAN/TILT lever is now operated, the registration of the tracing memory data is cancelled.

5 Press the START button. The lamp of the START button flashes, and the recording standby mode is established. ≥If the STOP button is now operated, the registration of the tracing memory data is cancelled.

6 Since tracing memory recording starts at the point where the PAN, TILT, ZOOM or FOCUS control is operated, proceed to register the data. The lamp of the START button stops flashing, and the lamp of the STOP button starts flashing. As a general rule, the time which can be stored in the memory is about 3 seconds for each of the PRESET MEMORY buttons No.1 to 10 and about 30 seconds for each of the PRESET MEMORY buttons No.11 to 30. Starting with the No.10 button, the button lamps go off every 3 seconds to indicate the remaining time for recording in the memory. When the lamps of all the buttons have gone off, the buzzer sounds, and the registration of the tracing memory data is ended. ≥To suspend the recording of the tracing memory data at any time, press the STOP button.

The operations performed up to the moment when the recording was suspended are registered as the tracing memory data. ≥The buzzer sounds when the tracing memory data recording starts, is suspended or ends.

7 If necessary, register the data in TRACING MEMORY buttons No.1 to 10.

8 Select another pan/tilt head system using the CONTROL SELECT button, and proceed with the tracing memory data settings for the pan/tilt head system concerned. Repeat this step for all the pan/tilt head systems.

The tracing memory information is recorded in the pan/tilt heads and controllers.

If a pan/tilt head or controller is replaced, re-register the data in the tracing memory.

Playing the tracing memory data

1 Select the pan/tilt head system using one of the CONTROL SELECT buttons.

2 Press the button in which the tracing memory data to be played is registered. The pan/tilt head system is set to the start position registered in the tracing memory.

3 After the pan/tilt head system has been set to the start position registered in the tracing memory and stopped, the operation of the data registered in the tracing memory can be started by pressing the button corresponding to the tracing memory in which that data is registered. ≥To suspend the play of the tracing memory data at any time, press the STOP button.

Play is also suspended when the PAN, TILT, ZOOM or FOCUS control is operated. ≥The buzzer sounds when tracing memory play starts, is suspended or ends.

Page 53 of the Panasonic AW-RC400E user manual — $ Setting the preset memory data
Seite 53 · Zum Vergrößern klicken
Seite 53

Operating procedures

Changing the tracing memory data

1 Select the pan/tilt head system using one of the CONTROL SELECT buttons. When using the AW-CB400 for camera control, select the same number for the AW-CB400.

2 Press the button corresponding to the tracing memory whose registered data is to be changed, and call the start position.

3 Press the RESTORE button. The lamp of the RESTORE button flashes, and start position setting in the tracing memory can be changed. ≥If the STOP button is pressed at this point, the change mode is cancelled.

4 Press the RESTORE button again. The pan/tilt head system starts the operation registered in the tracing memory, and the lamp of the RESTORE button stops flashing and lights. As when the data was registered, the PRESET MEMORY buttons 1 to 30 serve to provide a general indication of the time.

5 Change the tracing memory operation. ≥It is not possible to change parts of the tracing memory operation. Re-register the whole operation from the point where

the change was made all the way to the end.

6 When the lamps of all PRESET MEMORY buttons have gone off, the buzzer sounds, and the changing of the tracing memory data is completed.

Erasing the tracing memory data

1 Select the pan/tilt head system using one of the CONTROL SELECT buttons.

2 Press the RESET button. The lamps of the buttons (TRACING MEMORY buttons 1 to 10) corresponding to the tracing memories in which data has been registered now light.

3 Press the button with the number whose data is to be erased. The lamp of the button goes off, and the tracing memory data is erased.

$ Setting the preset memory data

Perform these settings on the AW-RP400 pan/tilt head controller.

The AW-RP400 comes with a preset memory function for registering the positions and settings used for shooting by the pan/tilt head systems. The preset memory data is registered in PRESET MEMORY buttons 1 to 50.

Registering the preset memory data

1 Select the pan/tilt head system using one of the CONTROL SELECT buttons.

2 Set the statuses of the pan/tilt heads and cameras. ≥Decide on the view angle and focus using the PAN, TILT, ZOOM and FOCUS controls. ≥Select auto iris or manual iris using the IRIS [AUTO/MANUAL/LOCK] button. ≥If manual iris is selected, adjust the iris using the IRIS dial. ≥Adjust the black level, black balance and white balance using the camera controller.

3 While holding down the MEMORY button, press one of the buttons (PRESET MEMORY buttons 1 to 50) in which the preset memory data is to be registered.

4 If necessary, register other shooting positions and settings in PRESET MEMORY buttons 1 to 50 as preset memory data.

5 Select another pan/tilt head system using the CONTROL SELECT button, and proceed with the preset memory data settings for the pan/tilt head system concerned. Repeat this step for all the pan/tilt head systems.

Page 54 of the Panasonic AW-RC400E user manual — Operating procedures
Seite 54 · Zum Vergrößern klicken
Seite 54

Operating procedures

Playing the preset memory data

1 Select the pan/tilt head system using one of the CONTROL SELECT buttons.

2 When the button corresponding to the registered preset memory data is pressed, the pan/tilt head system is set to the registered status.

Page 55 of the Panasonic AW-RC400E user manual — MONITOR SELECT setting
Seite 55 · Zum Vergrößern klicken
Seite 55
Page 55 of the Panasonic AW-RC400E user manual — MONITOR SELECT setting

Frage zu Panasonic AW-RC400E stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Panasonic AW-RC400E

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Panasonic AW-RC400E PDF-Anleitung

272 Seiten·6.1 MB·Digitalkamera·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…