W eather Station with Scrolling Message Alerts Model: BAR933HG / BAR936HG User Manual BAR933HG Eng Cover R7 OP 8/20/04, 11:03 PM 1 Black.
EN 1 CONTENTS Contents ................................................................... 1 Introduction .............................................................. 1 Product Overview .................................................... 2 Front View .
EN 2 1. LCD display 2. MODE: Change settings / display 3. MEMOR Y : View current, maximum and minimum temperature / humidity / UV readings 4. HISTOR Y : View historical barometer / temperature / humidity and UV readings 5. MESSAGE: View dif ferent messages 6.
EN 3 2 1 3 4 5 1 3 4 5 2 6 7 8 9 10 1 2 4 5 3 6 7 8 9 10 13 1 1 12 LCD DISPLA Y 1. Weather Forecast Area: Animated weather forecast 2. Clock / Alarm / Calendar Area: Radio-controlled clock; alarms; calendar 3. UVI / Barometer Area: UV Index and barometric pressure readings 4.
EN 4 REMOTE SENSOR (RTGR368N) 1 2 3 4 1. LCD display 2. LED status indicator 3. V entilation duct 4. Fold-out stand 1. Signal reception 2. T ime 3. Channel number 4. T emp / humidity readings 5. Low battery icon 6. T emp ( ° C or ° F) 7. Humidity % 1 2 3 4 5 6 7 Made in PR C RTGR368 N SEARCH RESET 12 3 4 5 CHANNEL EU UK C F 1 3 4 5 2 6 7 1.
EN 5 GETTING ST ARTED BA TTERIES Batteries are supplied with this product: • Main unit 4 x UM-4 (AAA) 1.5V • Remote unit 2 x UM-3 (AA) 1.5V Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit.
EN 6 T o fold out the stand: T o use the wall mount: For best results: • Insert the batteries and select the unit, channel, and radio signal format before you mount the sensor . • Place the sensor out of direct sunlight and moisture. • Do not place the sensor more than 70 metres (230 feet) from the main (indoor) unit.
EN 7 RF clock enabled: RF clock disabled: SET CLOCK Y ou only need to do this if you have disabled the radio- controlled clock, or if you are too far from a RF signal. 1. Press SELECT to navigate to the Clock Area. will show next to the Area. 2. Press and hold MODE for 2 seconds.
EN 8 ACTIV A TE ALARM Navigate to the Clock Area, then press ALARM / to switch to Daily Alarm or Pre-Alarm view . T o activate or deactivate the alarm, press UP or DOWN . When the alarm time is reached, the backlight will be on for 5 seconds and crescendo alarm will sound for 2 minutes.
EN 9 2. Press CHANNEL to select user 1-4. 3. Press and hold MODE for 2 seconds to enter the Skin T ype Setting Mode of the selected user . 4. Press UP or DOWN to choose 1 of the 4 skin type settings. Then press MODE to confirm and enter the SPF Set Up Mode.
EN 10 ZONE WET COM TEMPERA TURE HUMIDITY Any >70% 20-25 ° C (68-77 ° F) 40-70% DRY Any <40% This information is shown in the Humidity Area when the current measurement is displayed. HEA T INDEX The Heat Index advises 4 levels of warning if the temperature is high.
EN 11 MESSAGE DEFINITION Heat Index N / A Possibility of heat exhaustion Strong heat: Possibility of dehydration V ery strong heat: Heat exhaustion likely Intense heat: Strong possibility of heat stroke 26.7 ° C to 32.2 ° C / 80 ° F to 90 ° F 32.2 ° C to 40.
EN 12 SPECIFICA TIONS Main Unit Dimensions L x W x H 295 x 86 x 1 10 mm (1 1.61 x 3.39 x 4.33 inches) Weight 386 grams (0.85 lbs) without battery Remote Unit Dimensions L x W x H 70 x 24.
EN 13 EC-DECLARA TION OF CONFORMITY This product contains the approved transmitter module that complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.
© 2004 Oregon Scientific. All Rights Reserved. P/N.: 086-003589-019 BAR933HG Eng Back R7 OP 8/20/04, 11:03 PM 1 Black.
Ein wichtiger Punkt beim Kauf des Geräts Oregon Scientific BAR933HG (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Oregon Scientific BAR933HG noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Oregon Scientific BAR933HG - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Oregon Scientific BAR933HG reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Oregon Scientific BAR933HG erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Oregon Scientific BAR933HG besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Oregon Scientific BAR933HG verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Oregon Scientific BAR933HG. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Oregon Scientific BAR933HG gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.