Benutzeranleitung / Produktwartung OPL 9712 des Produzenten Opticon
Zur Seite of 27
OPL 9712 Barcode Data Collector Specifications Manual.
Opticon OPL 9712 S pecifications Manual 2 All information subject to change without notice. Document History Model Number: OPL 9712 Specification Number: SS06071 Edition: 1 Original Spec Number: SS06050 Date: 2007-02-05 Copyright 2007 Opticon. All right s reserved.
Opticon OPL 9712 S pecifications Manual 3 Content s 1. Abstract ....................................................................................................................... .............5 2. Overview ........................................
Opticon OPL 9712 S pecifications Manual 4 14.2. Vibration Strength ..........................................................................................................23 14.3. Dust and Drip Proof .................................................
Opticon OPL 9712 S pecifications Manual 5 1. Abstract This manual provides specifications for the OPL 9712 barcode data colle ctor (hereafter referred to as “data collector”). 2. Overview This scanner uses laser technology. To start a scan, press the trigger switch.
Opticon OPL 9712 S pecifications Manual 6 Applications can be developed for this product using the Software Development Kit (SDK). Software can be developed in the C programming language. These development tools are available as accessories. Figure 1: Reading a barcode.
Opticon OPL 9712 S pecifications Manual 7 4. Environmental Specifications 4.1. Operating Temper ature and Humidity Temperature: 0 to 40° C Humidity: 20 to 85% 4.
Opticon OPL 9712 S pecifications Manual 8 5. Electrical Specifications Item Specifications Remarks Main battery 600 mAh lithium-ion battery Main battery life Rechargeable: 300 times Backup battery 3.
Opticon OPL 9712 S pecifications Manual 9 8. Technical Specifications The conditions for technical specifications are as follows, unle ss otherwise specified in each section.
Opticon OPL 9712 S pecifications Manual 10 The scanning range follows a rectilinear path and expands in the shape of an arc while centering (focusing) on a distant virtual reference point. PCS Resolution (mm) Decode Depth (mm) 0.9 1.0 60–300 0.5 35–21 0 0.
Opticon OPL 9712 S pecifications Manual 11 8.3. Pitch, Skew, and Tilt 8.3.1. Pitch Angle Scanning performance is guaranteed at α ±25°. Figure 4: Pitch.
Opticon OPL 9712 S pecifications Manual 12 8.3.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection) (Depth of field: Within 90 mm from the minimum scannable distance).
Opticon OPL 9712 S pecifications Manual 13 8.3.3. Tilt Angle Scanning performance is guaranteed when γ = ±20° γ = 2 0 ° γ = 2 0° Figure 6: Tilt angle Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance: 90 mm from the edg e of the data collector Label: Pitch, Skew Angle PCS = 0.
Opticon OPL 9712 S pecifications Manual 14 8.4. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R ≥ 15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R ≥ 20 mm. Figure 7: Curvature Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.
Opticon OPL 9712 S pecifications Manual 15 9. Interface Specifications 9.1. Bluetooth Specifications Bluetooth® is a registered trademark owned by its proprietor and used by OPTOELECTRONICS Co.
Opticon OPL 9712 S pecifications Manual 16 9.2. Frequency Bluetooth devices use the 2.4 GHz frequency band. Scientific, medical, and industrial devices, including microwaves, wireless security (camera) systems and WLAN use the same frequency band as this scanner.
Opticon OPL 9712 S pecifications Manual 17 10. Default Settings 10.1. Default Settings 1: Readable Codes Symbology Read Transmit Code Length Transmit CD Calculate CD Set Prefix Set Suffix Othe r UPC-A.
Opticon OPL 9712 S pecifications Manual 18 Symbology Read Transmit Code Length Transmit CD Calculate CD Set Prefix Set Suffix Other RSS-14 X X — CR RSS-limited X X — CR RSS-expande.
Opticon OPL 9712 S pecifications Manual 19 11. Serial Number The serial number shown on the right is written on silver matte with black paper affixed to the backside of the OPL 9712.
Opticon OPL 9712 S pecifications Manual 20 12. FCC Labels This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Opticon OPL 9712 S pecifications Manual 21 13. Packaging Specifications 13.1. Individual Packaging Specification Place the OPL 9712 in a protection bag E, and pack it in the provided box. Then place the accessories into the box. Accessories: • 1 lithium-ion battery • 1 hand strap Close the box and affix a label to the side of the box.
Opticon OPL 9712 S pecifications Manual 22 13.2. Labeling Figure 11: Labels When packing 50 pre-packaged data collectors, select a bo x size equal to 560 mm (W) by 490 mm (D) by 195 mm (H).
Opticon OPL 9712 S pecifications Manual 23 14. Durability 14.1. Shock There was no damage to the data collector structure or data collector operation after dropping the data collector from a height of 1.5 meters onto a concrete flo or. Each side of the data collector impacted the floor three times.
Opticon OPL 9712 S pecifications Manual 24 16. Regulatory Compliance 16.1. Laser Safety The data collector emits laser beams. • JIS C6802: 2005: Laser class 1 • IEC60825-1: Laser clas s 1 • CDRH Laser class I. Complies with 21 CFR 1040.10 and 10 40.
Opticon OPL 9712 S pecifications Manual 25 16.4. R&TTE This scanner conforms to the following standards of the Radio and Telecommunications Terminal Equipment (R&TTE) directive from the EU. EN300 328 EN301 489-1 IEC60950-1 EN60950-1 The scanner qualifies as radio equipment for low-power radio stations (2.
Opticon OPL 9712 S pecifications Manual 26 17. Safety Handle this product carefully. Do not deliberately subject it to any of the following. 17.1. Shock • Do not throw or drop the data collector.
Opticon OPL 9712 S pecifications Manual 27 18. Mechanical Drawing 1 2 3 5 8 AB CD E F JK L T UV 6 M N O 9 WXYZ 7 4 G HI P Q RS CL R BS Sh i f t 0 . *..
Ein wichtiger Punkt beim Kauf des Geräts Opticon OPL 9712 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Opticon OPL 9712 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Opticon OPL 9712 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Opticon OPL 9712 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Opticon OPL 9712 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Opticon OPL 9712 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Opticon OPL 9712 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Opticon OPL 9712. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Opticon OPL 9712 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.