2 Intelligent Flag I/II V600-HA Intelligent Flag I/II V600-HA Innov ative RFID Electronic Fla gs to Replace Mechanical Fla g and Kanban Systems • Doesn't need a program and can be used like a sensor . • Advanced line construction at minimal co st.
Intelligent Flag I/II V600-HA 3 Note: The connector is not water proof. If there is a possibility that the connector ma y be exposed to water , k eep it inside the contr ol box. Be sure to use the connector together with t he separately sold interface cable.
4 Intelligent Flag I/II V600-HA ■ Sensor ■ Transmission Distance Specifications Recommended Combinations Note: 1. The specifications tak e fluctuations in ambient temperature and slight di fferences between products into account. 2. The read distance and write dista nce are the same.
Intelligent Flag I/II V600-HA 5 System Configuration Programmable Controller, I/O terminal, B7A, CompoBus/S, etc. Sensor Controller V600-A6 R V600-A6 M Interface cable Amplifier Sensor Data Ca.
6 Intelligent Flag I/II V600-HA Characteristic Data (Typical) ■ Transmission Range Combinations with the V600-HS51 Sensor Combinations with the V600-HS61 Sensor 0 –4 –8 4 8 4 8 X Y Y X 0 –4 .
Intelligent Flag I/II V600-HA 7 Combinations with the V600-HS63 Sensor X 0 –10 –20 –30 10 20 30 10 20 30 Y Y X 0 –10 –20 –30 –40 10 20 30 40 Y X 10 20 30 X Y 0 –10 –20 –30 –40 .
8 Intelligent Flag I/II V600-HA Combinations with the V600-HS67 Sensor ■ Transmission Time The transmission time ref ers to the time r equired for communications betw een the Sensor and the Data Carrier . It is used f or ca lculating the tra vel speed of the auto command.
Intelligent Flag I/II V600-HA 9 Circuit Configuration V600-HAR91 V600-HAM91 Input Circuit Output Circuit V600-HAR92 Input Circuit Output Circuit V600-HAR81 V600-HAM81 Input Circuit Output Circuit Prec.
10 Intelligent Flag I/II V600-HA P ower Supply V oltage Do not impose any v oltage exceeding the rated v oltage range. Doing so , or applying alter nating curr ent (100 V AC) ma y cause the product to explode or b ur n. Load Short-circuiting Do not shor t-circuit the load c onnected to the product or connect to the power supply .
Intelligent Flag I/II V600-HA 11 Dimensions Note: All units are in millimeter s unless otherwise indicated. Amplifier V600-HAR91/-HAR81 * Enlarged Section of Mounting Hole T wo, mounting holes * Vinyl-insulated round cord 5.8-mm dia., 13-conductor cable, standard length: 0.
12 Intelligent Flag I/II V600-HA V600-HAM91/-HAM81 * Enlarged Section of Mounting Hole T wo mounting holes * Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m XG4E-2631 30˚ 4.4 5.5 30 21 17.5 28.3 36.3 61.8 52.3 44.3 89 8.
Intelligent Flag I/II V600-HA 13 V600-HAR92 Sensor V600-HS51 V600-HS61 XG4E-2631 30˚ 4.4 5.5 30 21 17.5 28.3 36.3 61.8 44.3 89 8.2 98 68.5 75 55 30 80 35.2 500 mm 28.1 52.3 25 6 25 2-M4 89 ± 0.2 21 ± 0.2 * Enlarged Section of Mounting Hole T wo, mounting holes * Vinyl-insulated round cord 5.
14 Intelligent Flag I/II V600-HA V600-HS63 V600-HS67 Interface Cable V600-A6 @ R (for V600-HAR91/-HAR8 1)) 51.5 10 20 53 27 6 40 28 23 11 5 5 18 13 5 13.
Intelligent Flag I/II V600-HA 15 V600-A6 @ M (for V600-HAM9 1/-HAM81/-HAR92) Model L (m) V600-A60R/60M 2 V600-A61R/61M 5 V600-A62R/62M 10 Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.), 23-conductor cable, standard length: 2 m XG5M-2632-N Connector 7.
1 6 Intelligent Flag I/II V600-HA Terms and Condi tions W ARRANTY , LIMI T A TIONS OF LIABILITY W ARRANTY OMRON’ s exclusiv e warranty is that the products are free from def ects in materials and work manship f or a period of one year (or other period if specified) f rom date of sale b y OMRON.
Ein wichtiger Punkt beim Kauf des Geräts Omron V600-HA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omron V600-HA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omron V600-HA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omron V600-HA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omron V600-HA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omron V600-HA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omron V600-HA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omron V600-HA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omron V600-HA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.