Benutzeranleitung / Produktwartung HEM-907 des Produzenten Omron Healthcare
Zur Seite of 26
1 INS TR U CTION MAN U AL OMR ON Digital Automatic Blood P ressure Mon itor Model HEM - 9 0 7 HID E P - SE T 1 00 AU T O 1 40 1 80 220 260 280 MOD E A VG. M AN U . CHE CK SI N G LE O N / OF F A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N STA RT STO P mm Hg SYS mmHg DIA BPM PU L SE A RT .
2 Intended Us e Medical P urpose This i s a medical de vice that meas ures the bra chial blood pressu re in a non-inv asiv e mann er . Intended Us er Legally c er ti ed : such as d octor , nu rse and med ic al e xpert. Pa tien t Popu lation It is us ed on adult p atien ts only .
3 E x emptions OM RON will not be ar any responsibilitie s on t he following mat ters. When a p roblem or d amage occu rs c au sed by th e main ten ance an d/or r epai r c on- du cted b y a person oth.
4 Names and F unctions of the P ar ts HIDE P - SET 10 0 AUTO 14 0 18 0 220 260 280 MODE A VG. MANU. CHECK SINGLE ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START ST OP mmHg SYS mmHg DIA BPM PULSE AC DC8V 1 . L CD display 2. HID E ( non- display ) Button 3.
5 Ba t tery lev el Displays for the usable level. Displays for the l ow level. Displays for the unusable level. Names and F unctions of the P ar ts Displa y HIDE BPM mmHg PULSE SYS mmHg DIA AC Systolic blood pressure Dias tolic b lood pressure Con ten ts when the A V G.
6 Names and F unctions of the P ar ts Explanation of F unct ions ( 1 ) P ressure sett ing function P - SET In ation c an be set by AUT O (automatic set ting ) or th e target value. A UTO ( automatic setting) : In the SIN GLE (single measurement ), A VG.
7 Names and F unctions of the P ar ts ( 4) Set ting mo de ch ange func ti on Y o u can set th e number of times to m easure, the waiting ti me until the st ar t of measurem ent, and the inter val bet ween measurements.
8 Notes on S afet y The war ning signs and the sample ic ons show n here are listed for you to use t he product s afely and cor rect ly as well as to prevent the risk and the damag e to you and others f rom happening. The ic ons and meanings are as follow.
9 Notes on S afet y Caution When you are n ot going to use t he unit for a long p eri od of time, be sure to remove the AC adapter from the electric outlet. Y ou may suf fer elect ric shoc k, or electr ic leak or re may arise beca use of deter iorated insulation.
10 Notes on S afet y Caution Be sure to use the p ower supply of 23 0 V AC. It may cause re or electr ic shock. Do not share an elect ric outl et with other unit or elec tric applianc e. It may c ause re or electric leak. Do not pull the p ower co rd when pulling out the AC adapter fro m the elect ric out let.
11 Notes on S afet y Maintenance Be sure to inspec t the unit on regular basis. Check ac curac y on a 1 year inter val. If the unit has not be en used for a while, be sure to c on rm t hat the unit oper ates nor mally and safely before us e Durabilit y The durabilit y of thi s unit is ve y ear s.
12 Components of the P roduct Main unit Access ories HIDE P - S E T 10 0 A U TO 14 0 1 80 2 2 0 260 280 MODE AVG . MA N U . C HE C K S IN G L E ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START STOP Medium size ar m cuf f ( with built- in air bag ) Model : HE M -9CMC Ar t.
13 Sel ec t th e ar m cu f f ac cor din g to t he ar m c ircu mf ere nce o f th e pat ie nt . Ar m circumferenc e Name of the ar m cuf f 1 7 - 22 cm 22 - 32 c m 32 - 42 cm Small size adult arm c uf f ( option ) Adult arm c uf f Larg e size adult arm cu f f ( opti on ) Be sure to use the ar m cuf f suitable for the size of the pat ient ’ s arm.
14 Ho w to Apply the Ar m C uf f (c o n t .) R A N G E ART . RA N G E A R T. INDE X 22 ~ 32cm ( 9" ~ 13" ) R EF HEM - CR 19 Adju st t he l evel of t he a rm c uf f t o th e leve l of th e he ar t. Keep the level of the arm c uf f at the s ame level as the hear t dur ing the measure - ment.
15 Ho w to Measure B lood P ress ure Warning If any abnormal mat ter oc curs dur ing the me a- surement such as t he in ation does not sto p , remove the arm c uf f or pull the air tub e from t he main unit. Y ou may suf fer per ipheral neuropathy .
16 Ho w to Meas ure Blood P ress ure (in SI NGLE M ode) Wrap t h e ar m cuf f ov e r th e patient’s ar m. 1. Set t he M OD E Sel ec to r to “SINGLE” . 3. ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START STOP HIDE P - SET 100 AUTO 140 18 0 220 260 280 MODE AVG.
17 Wrap t h e ar m cuf f ov e r th e patient’s ar m. 1. Set t he M OD E Sel ec to r to “AV G . ”. 3. ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START STOP HIDE P - SET 100 AUTO 140 18 0 220 260 280 MODE AVG. MANU. CHECK SINGLE Push t he ST ART B ut to n to st ar t the meas urement.
18 Ho w to Meas ure Blood P ress ure (in MA NU. Mode) Wrap t h e ar m cuf f ov e r th e patient’s ar m. 1. Push t he O N/OFF (p owe r) But t on to t ur n on t he pow er . 3. ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START STOP HIDE P - SET 100 AUTO 140 18 0 220 260 280 MODE AVG.
19 Ho w to Meas ure Blood P ress ure (in CHECK M od e) Disp lay of pre ssure c an b e con r me d by the CH ECK Mode (yea rly p roc edur e ). Wha t you nee d to pre pare ( 1 ) Well- adjusted referen.
20 Installation and R eplacement of Ba t t er y Pa ck Rem ove the b at t er y c over on t he b ack o f th e main unit. Installation: T o install the bat ter y pack, c onnec t the bat ter y pack c onnec tor to the c onnecto r in the bat ter y cover . Replacement: Remove the batter y pac k fro m the co nnector and replac e wit h a new one.
21 Cle an th e bl ood p re ssur e mon it or ,t he cu f f an d th e ca bl es usi ng a cl ot h da mp ene d wi th wa te r ,dilu te d disinfectant alcohol or diluted mild detergent. T o disinfect, wipe t he unit with a s of t clot h squeezed well af ter moistened w ith the foll owing disinfect ant.
22 L ist o f Error C odes Erro r cod e Cause How to co rre ct Er1 In at ion erro r When the pre ssure does n ot ex ce ed 1 5 mmHg af ter oper ating a pump for 15 se conds from t he star t of in .
23 If a t roubl e occur s whil e using th e unit , pl ease che ck th e followin g. Proble m Wha t to inspe ct How to co rre ct The unit in ates to abnor mally high (low) pressure. Is the ar m cuf f w rapped c or rec tly ? Wrap the arm c uf f c orrec tly , and measure again.
24 Speci cati on s Name : OM RON Di gital Automat ic Bloo d Pressure M onitor H EM - 907 Model : HEM- 907 - E / HEM- 907 - E7 Display : Digita l display Measurement : Osc illometr ic method Measur.
25 Manufacturer OMRON HEAL THC ARE Co., L td. 53, K unots ubo , T era do - cho , Muk o , K y ot o, 6 1 7 - 00 02 JAP A N EU- representative OMRON HEAL THCARE EUR OPE B. V . Scorpiu s 33, 2 1 3 2 LR Hoo fddo r p , THE NETHE RL A NDS w w w .omr o n - h e al th c a re.
26 Englis h Im po r t ant i nf or ma ti on r eg ar di ng E le ct ro M ag net ic C om pa ti bi li ty ( E MC ) Wi th t he in cre as ed nu mbe r of el ec tr oni c dev ic es su ch as P C. s and m obi le ( c ellular) telephones, medic al devices in use may be susc eptible to electromagnetic interference from other de vices.
Ein wichtiger Punkt beim Kauf des Geräts Omron Healthcare HEM-907 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omron Healthcare HEM-907 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omron Healthcare HEM-907 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omron Healthcare HEM-907 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omron Healthcare HEM-907 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omron Healthcare HEM-907 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omron Healthcare HEM-907 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omron Healthcare HEM-907. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omron Healthcare HEM-907 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.