Benutzeranleitung / Produktwartung DP63000A-I des Produzenten Omega Vehicle Security
Zur Seite of 16
LP0694A omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at D D P P 6 6 3 3 0 0 0 0 0 0 A A -I I D D P P 6 6 3 3 0 0 0 0 0 0 B B -I I Digita .
OMEGAnet ® Online Ser vice omega.com Inter net e-mail info@omega.com Ser vicing North America: U.S.A.: One Omega Drive, P .O . Bo x 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.
3 z FOUR SELECT ABLE D.C. RANGES 200 µ A, 2 mA, 20 mA, 200 mA z MINIMUM AND MAXIMUM DISPLA Y CAPTURE z LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING z 0.
1. DISPLA Y : 5 digit LCD 0.48" (12.2 mm) high digits DP63000A-I : Reflective LCD with full viewing angle DP63000B-I : T ransmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module.
5 ADDING OPTION CARDS The DP63000 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below . The plug-in cards, that are sold separately , can be installed initially or at a later date.
WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter . All conductors should conform to the meter ’ s voltage and current ratings. All cabling should conform to appropriate standards of good installation, local codes and regulations.
7 4.3 INPUT WIRING CAUTION : Power input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential.
8 5.0 R EVIEWING THE F RONT B UTTONS AND D ISPLAY PROGRAMMING MODE ENTR Y (SEL BUTT ON) It is recommended all programming changes be made off line, or before installation. The meter normally operates in the Display Mode. No parameters can be programmed in this mode.
9 6.1 MODULE 1 - S IGNAL I NPUT P ARAMETERS ( 1-INP ) P ARAMETER MENU ª « 0.02A rAN6E INPUT RANGE Select the input range that corresponds to the external signal. This selection should be high enough to avoid input signal overload but low enough for the desired input resolution.
Entering Code 66 will overwrite all user settings with the factory settings. The meter will display rESEt and then return to CodE 00 . Press the SEL button to exit the module.
11 The Security Code determines the programming mode and the accessibility of programming parameters. This code can be used along with the Program Mode Lock-out ( P-Loc ) in the User Input Function parameter (Module 1). T wo programming modes are available.
Enter the reset action of the output. See figure for details. Auto = Automatic action; This action allows the output to automatically reset off at the trigger points per the Setpoint Action shown in Setpoint Output Figures. The “on” output may be manually reset (of f) immediately by the front panel RST button or user input.
13 6.5 MODULE 5 - S ERIAL S ETUP P ARAMETERS ( 5 -S S E r ) The Serial Setup Parameters are only active when the optional RS232 or RS485 serial communications module is installed in the meter . Refer to the DP6-COM bulletin for complete details on DP63000 serial communications.
PROGRAMMING QUICK OVERVIEW Press and hold SEL button to enter Programming Mode..
W ARRANTY/DISCLAIMER OMEGA ENGINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I F ind Everything I Need for P rocess Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERA TURE ] Thermocouple, RTD & Thermistor Probes, Connectors, P anels &.
Ein wichtiger Punkt beim Kauf des Geräts Omega Vehicle Security DP63000A-I (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega Vehicle Security DP63000A-I noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega Vehicle Security DP63000A-I - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega Vehicle Security DP63000A-I reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega Vehicle Security DP63000A-I erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega Vehicle Security DP63000A-I besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega Vehicle Security DP63000A-I verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega Vehicle Security DP63000A-I. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega Vehicle Security DP63000A-I gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.