FPDM1000 SERIES Positive Displacement Mechanical Flowmeters.
.
Please read this information carefully befor e use! Before use, confirm the fluid to be used is compatible with the meter or consult with OMEGA for advice. To prevent damage fr om dirt or foreign matter , OMEGA recommends a Y or bas- ket type 60 mesh strainer be installed as close as possible to the inlet side of the meter .
1. OMEGA recommends that when set- ting up pipework for meter installations, a bypass line be included in the de- sign. This provides the facility for a meter to be removed for maintenance without interrupting production. (See Figure 1) 2 NOTE: Incorrect installation can cause pr e- mature wear of meter components 7.
3 OPERA TION SERVICE INSTRUCTIONS When fluid passes through the meter , the ro tors tur n. The gear located on top of one of the rotors drives the mechanical r egis- ters gear train which provides an accurate r eadout.
4 Check rotor operation by turning either of the rotors. If the r otors are not in mesh correctly or do not move fr eely , remove one of the rotors and r eplace it correctly at 90 degrees to the other r otor . Recheck the operation of the rotors. 4. Inspect the gears in the meter cap for wear .
5 Symptom Probable Cause Corrective Action FLUID WILL NOT 1. Foreign matter blocking Dismantle meter , clean rotors. Strainer must FLOW THROUGH rotors be fitted in-line. THE METER 2. Line strainer blocked Clean strainer . 3. Damaged rotors Replace rotors.
6 4 3 2 1 20 * 21 * 7 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 6 METER P ARTS LISTING Model: FPDM1004 Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS298N Meter Body 1/2 in. NPT (Aluminum) 11 MS337N Meter Body 1/2 in.
7 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 1 to 30 / 0.26 to 8 Below 5 centipoise 3 to 25 / 0.8 to 6.6 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.
8 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS188N Meter Body 1 in. NPT (Aluminum) 11 MS186N Meter Body 1 in. NPT (Stainless Steel) 11 MS188F Meter Body 1 in. ANSI 150 lb. Flange (Aluminum) 11 MS186F Meter Body 1 in.
9 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 6 to 120 / 1.6 to 32 Below 5 centipoise 10 to 100 / 2.6 to 26 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.
10 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS192N Meter Body 1 1 / 2 in. NPT (Aluminum) 11 MS190N Meter Body 1 1 / 2 in. NPT (Stainless Steel) 11 MS192F Meter Body 1 1 / 2 in. ANSI 150 lb.
11 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 10 to 250 / 2.6 to 66 Below 5 centipoise 15 to 235 / 4 to 62 Accuracy of Reading ± 1% Maximum Viscosity * 1000 C.
6 2 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 4 3 1 1 10 20 * * 7 5 12 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS520N Meter Body 2 in. NPT (Aluminum) 11 MS520-1N Meter Body 2 in.
13 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 15 to 350 / 3.96 to 92.46 Below 5 centipoise 30 to 300 / 7.93 to 79.
.
.
.
.
M- 4103/ 04 05.
Ein wichtiger Punkt beim Kauf des Geräts Omega FPDM1000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega FPDM1000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega FPDM1000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega FPDM1000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega FPDM1000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega FPDM1000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega FPDM1000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega FPDM1000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega FPDM1000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.