Benutzeranleitung / Produktwartung OS136 des Produzenten Omega Engineering
Zur Seite of 16
OS136 SERIES Miniature Low-Cost Non-Contact Infrared T emperature Sensor/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.
Servicing Nor th America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 USA Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.
i OS136 Series Miniature Low-Cost Non-Contact Infrared T emperature Sensor/T ransmitter T able of Contents Section Page Caution and Safety Information .................................................................. iii Safety W arnings and IEC Symbols .
OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter ii List of Figures Figure Description Page 2-1 General W iring Diagram ................................................................ 2 3-1 Optical Field of V iew ..
OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter iii CAUTION & SAFETY INFORMA TION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impair ed. The Installation category is one (1).
1 SECTION 1 - INTRODUCTION The model OS136 series is a very low-cost, super-compact infrar ed transmitter . It measures temperatur e via non-contact, and provides an analog output proportional to the measur ed temperature. The OS136 series is of fered in two temperature ranges: -18 to 204ºC (0 to 400ºF) and 149 to 538ºC (300 to 1000ºF).
2 2 The following describes the ordering information: OS136 – * – ** , where - * means: -1 : -18 to 204ºC (0 to 400ºF) T emperature range -2 : 149 to 538ºC (300 to 1000ºF) T emperature range -.
3 Operation 3 SECTION 3 – OPERA TION 3.1 – Measuring T emperature Before starting to measur e temperature, make sur e the following check list is met: The Power and output connections are made.
Operation 3 4 3.3 - Atmospheric Quality Environments with smoke , dust, and fume dirty up the optical lens, and cause erroneous temperatur e readings. T o keep the surface of the optical lens clean, the air purge collar accessory is r ecommended, OS136-AP (Fig 3-3).
Figure 3-4. Stainless Steel Housing Figure 3-5. Water/Air Cool Jacket, OS136-WC Figure 3-6. Water/Air Cool Jacket Assembly Operation 3 5 LIGHT HEX KNURL 4.76 ( 3 /16) WIDE DIMEN S ION S mm (in) 3 /4-16 UNF 88 .9 ( 3 .5) 1. 83 m (6ft) 33 .27 (1. 3 1) 19.
SECTION 4 - LASER SIGHT ACCESSOR Y 4.1 – W arning and Caution Y ou may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MA Y RESUL T IN HAZARDOUS RADIA TION EXPOSURE.
7 Figure 4-1. Laser Sighting Accessory, OS100-LS Figure 4-2. Laser Warning Label Laser Sight Accessory 4 LASER W ARNING LABEL DC POWER JACK LED LASER POWER INDICA TOR LASER BEAM 19 (0.75) 50.8 (2.0) 38.1 (1.5) POWER CABLE ON/OFF SWITCH BA TTERY P ACK POWER SUPPL Y OS136 Dimen s ion s mm (in.
Specifications 5 8 SECTION 5 – SPECIFICA TIONS 5.1 - General T emperature Range: OS136-1 -18 to 204ºC (0 to 400ºF) OS136-2 149 to 538ºC (300 to 1000ºF) Accuracy: @22ºC (72ºF) ambient OS136-1 3% of Rdg or 4.4ºC (8ºF) whichever is greater OS136-2 3% of Rdg or 5.
Specifications 5 9 5.2 - Laser Sight Accessory Laser W avelength (Color): 630 - 670 nm (Red) Operating Distance: Up to 9.1 m (30 ft.) Max. Laser Power Output: Less than 1 mW @ 22ºC ambient European Classification: Class 2, EN60825-1/1 1.2001 FDA Classification: Class II Laser Product.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from dat e o f p urch ase . OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
M3946/0806 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE Thermocouple, RTD & Thermistor Probes, Con.
Ein wichtiger Punkt beim Kauf des Geräts Omega Engineering OS136 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega Engineering OS136 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega Engineering OS136 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega Engineering OS136 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega Engineering OS136 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega Engineering OS136 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega Engineering OS136 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega Engineering OS136. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega Engineering OS136 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.