Introduction Omega Engineering OMG-COMM8-A Page 1 Introduction Overview The Omega Engineering OMG-COMM8-A provides the PC with eight RS -232 asynchronous ports. The OMG-COMM8-A allows for connection to any device utilizing the RS -232 electrical interface, such as modems, data -entry terminals, and plotters.
Introduction Omega Engineering OMG-COMM8-A Page 2 To install the OMG-COMM8-A using factory default settings, refer to the Installation section of this manual.
Card Setup Omega Engineering OMG-COMM8-A Page 3 Card Setup The OMG-COMM8-A contains several jumper straps that must be set for proper operation. Address Selection The OMG-COMM8-A occupies 64 I/O locations and can be addressed two different ways.
Card Setup Omega Engineering OMG-COMM8-A Page 4 The following illustration shows the correlation between the DIP-switch setting and the address bits used to determine the base address. In the example below, address 280 (Factory Default) is selected as a base.
Card Setup Omega Engineering OMG-COMM8-A Page 5 IRQ Selection The OMG-COMM8-A has an interrupt selection jumper that corresponds to each port that may have to be set prior to use. The software you are using with the board will determine which interrupts, if any are to be used.
Card Setup Omega Engineering OMG-COMM8-A Page 6 Interrupt Mode Options The OMG-COMM8-A will allow each port to have an independent interrupt level or share an interrupt with another port on the adapter. The OMG-COMM8-A will even share interrupts with a compatible port that is located on another adapter.
Card Setup Omega Engineering OMG-COMM8-A Page 7 Set jumpers to “ S ” for shared interrupt mode on all blocks sharing an IRQ except one. Set that port block for “ M ”. This provides the pull-down resistor circuit that makes sharing of IRQ possible.
Installation Omega Engineering OMG-COMM8-A Page 8 Installation The OMG-COMM8-A can be installed in any of the full size PC expansion slots, but to access the “AT” or (E )ISA IRQs (10, 11, 12, 15) it must be installed in one of the 16 bit slots.
Technical Descri ption Omega Engineering OMG-COMM8-A Page 9 Technical Description The Sealevel OMG-COMM8-A provides 8 additional serial ports for terminals, modems, printers, etc. The OMG-COMM8-A utilizes the 16550 UART chip. This chip features programmable baud rate, data format, interrupt control and a 16 byte FIFO.
Technical Descri ption Omega Engineering OMG-COMM8-A Page 10 DB-25 Connector Pin Assignments Signal Name Pin # Mode GND Ground 7 TD Transmit Data 2 Output RTS Request To Send 4 Output DTR Data Termina.
Specifications Omega Engineering OMG-COMM8-A Page 11 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F ) -20º to 70º C (-4º to 158º F) Humidity Range 10 to 90% R.H. Non -Condensing 10 to 90% R.
Appendix A - Troubleshooting Omega Engineering OMG-COMM8-A Page 12 Appendix A - Troubleshooting A Serial Utility Diskette is supplied with the Omega Engineering adapter and will be used in the troubleshooting procedures.
Appendix A - Troubleshooting Omega Engineering OMG-COMM8-A Page 13 6. The following are known I/O conflicts: • The 278 and 378 settings may conflict with your printer I/O adapter.
Appendix B - How To Get Assistance Omega Engineering OMG-COMM8-A Page 14 Appendix B - How To Get Assistance Please refer to Appendix A - Troubleshooting prior to calling Technical Support. 1. Read this manual thoroughly before attempting to install the adapter in your system.
Appendix C - Electrical Interface Omega Engineering OMG-COMM8-A Page 15 Appendix C - Electrical Interface RS -2 32 Quite possibly the most widely used communication standard is RS -232. This implementation has been defined and revised several times and is often referred to as RS -232-C/D/E or EIA/TIA -232-C/D/E.
Appendix D - Asynchronous Communications Omega Engineering OMG-COMM8-A Page 16 Appendix D - Asynchronous Communications Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character.
Appendix E – 3421 Addendum Omega Engineering OMG-COMM8-A Page 17 Appendix E - 3421 Addendum The OMG-COMM8-A can be equipped with a higher speed oscillator and the Startech 16C654 UART. This UART has a significantly larger FIFO (64 bytes as opposed to the 16 of the 16C554).
Appendix F - Silk-Screen Omega Engineering OMG-COMM8-A Page 18 Appendix F - Silk-Screen 4.2" 8.0" 3.9".
Appendix G - Compliance Notices Omega Engineering OMG-COMM8-A Page 19 Appendix G - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules.
Warranty Omega Engineering OMG-COMM8-A Page 20 Warranty Omega Engineering, Inc. warrants this product to be in good working order for a period of one year from the date of purchase.
Ein wichtiger Punkt beim Kauf des Geräts Omega Engineering OMG-COMM8-A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega Engineering OMG-COMM8-A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega Engineering OMG-COMM8-A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega Engineering OMG-COMM8-A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega Engineering OMG-COMM8-A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega Engineering OMG-COMM8-A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega Engineering OMG-COMM8-A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega Engineering OMG-COMM8-A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega Engineering OMG-COMM8-A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.