Benutzeranleitung / Produktwartung FV300 des Produzenten Olympus
Zur Seite of 16
CONFOCAL LASER SCANNING BIOLOGICAL MICROSCOPES FV300 FLUOVIEW.
1 FV300 CONFOCAL LASER SCANNING MICROSCO PERFORMANCE FOR THE PERSONAL USER The FV300 is the ideal choice of laser scanning microscopes for personal users.
2 OPE q e r t y u i o !0 !1 !2 w q Optical fiber for laser introduction w Beam collimator e Polarizer r Dichromatic mirror t Excitation dichromatic mirror y XY galvanometer mirror scanners u Pupil len.
Preset the conditions for image acquisition and loading Storage of Acquisition Settings enables immediate, one-touch recall of all the relevant experimental settings and conditions.
Image tool bar X-Y-Z scanning operations and time- lapse observations both produce multiple images, which can be displayed in sequence simply by clicking the sequential mode button. Channel selection and image zooming are also available on the same menu.
5 X -t Slant Line-t FreeLine-t Y -t Y-Z-t X-Y-t ZoomIn-t X-Z-t X-Y-t X-Y-Z-t ZoomIn-Z-t Patch clamp BX61WI fixed stage upright microscope+translation stage Image acquisition ROI designation Intensity versus time measurement Calcium sparks in isolated cardiac myocyte Dr.
6 The 440nm diode laser can be added for CFP/YFP FRET imaging. A 440nm diode laser is optionally available for CFP/YFP imaging. The 440nm laser line ideally excites CFP, with minimal disturbance to YFP, and is therefore suitable for CFP/YFP FRET experiments.
7 PAPP for FRAP Application PAPP: Programmable Acquisition Protocol Processor Easy, reliable flow of experiments for fluorescence recovery after photobleaching.
8 Multi-point time lapse system High-magnification multi-point time lapse observation of living cells. Wide-ranging specimen observations for improved experiment throughput Use of a motorized XY stage allows the analysis of time lapse changes in many points scattered over a wide area.
9 Tile display Topographic projection Height of 3D structure indicated by color. X-Z Y-Z X-Y-Z X -Z Y -Z Using multiple 3D images to obtain accurate 3D structure analysis.
10 Link with patch clamping data • With PCs linked through a LAN, Physiolink can synchronize electrophysiological and confocal image data simultaneously. • With the same time stamp recorded in the two PCs, it is possible to access and analyze an image and its patch clamping data corresponding to the Physiolink software time scale.
11 Lucifer Yellow: retina ganglion cell TexasRed: dopamine-operated amacrine cell Prof. Shigetada Nakanishi Dept. of Biological Sciences, Kyoto Univ. Faculty of Medicine Applications Gallery Morpholog.
12 Fluorescent Proteins C elegans expressing beta-integrin fused to GFP Dr. Xioping Xhu and Dr. John Plenefisch University of Toledo, Dept. of Biology GFP-labeling of Drosophila adults Expression of DsRed in a zebrafish embryo Extended focus image of 5µmx30 slice Pr.
Fluorescence Dyes and Filters 300 400 500 600 700 BA530RIF BA550RIF BA650RIF BA430-460 BA465-495 BA480-495 BA470-520 BA510-540 BA520-550 BA505-550 BA505-525 BA480-510 BA535-565 BA540-590 BA560-600 BA5.
Objectives for fixed stage upright microscopes (using WI-UCD, WI-DICTHRA) 14 Item Specifications Laser light Visible light laser source Select from the following laser, to mounted on laser combiner so.
● All brands are trademarks or registered trademarks of their respective owners. ● Monitor images are simulated. Specifications are subject to change without any obligation on the part of the manufacturer. This catalog is printed by enviromentally-friendly waterless printing system with soy ink.
Ein wichtiger Punkt beim Kauf des Geräts Olympus FV300 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Olympus FV300 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Olympus FV300 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Olympus FV300 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Olympus FV300 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Olympus FV300 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Olympus FV300 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Olympus FV300. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Olympus FV300 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.