M165939M.2 Owner’s Manual Instructions for Installation/Set-u p, Operation, Serv icing, & Storage Portable, Outdoor Use-Only, Triple Fuel Generator 10,500 Watt Continuous (13,000 Watt Surge) Cap.
Hazard Signal Word Definitions 2.
Table of Contents 3 Hazard Signal Word Definitions ................................................................................................. 2 About Your Generator ...............................................................................
About Your Generator 4 Thank you for purchasing your NorthStar portable generator! About Your Generator This engine-driven, portable generator is designed to provide up to 8000 Watts of electrical power (10,500 watts continuous, 13,000 watts surge). It can supply power: 1.
About Your Generator (cont’d) 5 This generator is too heavy for one person to lift without mechanical assistance. An optional wheel kit is available from NorthStar and is recomm ended if you will be moving the generator unassisted.
Specifications 6 SPECIFICATIONS Item Number #165939 Maximum Output 13500 Watts (W) Continuous Output: Gasoline Liquid Petroleum Gas (LPG) Natural Gas (NG) 10500 Watts (W) 9600 Watts (W) 8400 Watts (W) Voltage 120 / 240 Volt (V) Phase Single phase (4-wire) Frequency Regulation 56.
Safety Label Locations 7 Always make sure safety labels ar e in place and in good condition. If a safety la bel is missing or not legible, order new labe ls or unsafe opera tion could result. To order replacement safety labels , call NorthStar Product Support at 1-800-270-0810.
Machine Component Identification - Item #165939M.2 8 Figure 1 (Ref. 1-19) Ref. Description Ref. Description 1 Air Cleaner 15 Hour Meter 2 Gas Cap with Gauge 16 Oil Drain Area 3 10.
Machine Component Identification - Item #165939M.2 9 REFERENCE GUIDE Reference 1 – Air Cleaner Refer to your Honda engine manual for air cleaner care. Reference 2 – Gas Cap with Gauge The gas cap is extra large, creating a large hole for refueling and a comfortable grip.
Machine Component Identification - Item #165939M.2 10 and press the extended button back into the circuit breaker housing. Reference 13 - 120V, 20A, Duplex Receptacle The generator has a control panel with two duplex (two receptacles in a common housing) receptacles.
Power Load Planning & Management 11 WARNING NEVER exceed the rated wattage capacity of your generator. OVERLOADING may cause SERIOUS DAMAGE to the generator and attached electrical devices, and may result in fire. Your generator MUST BE SIZED PROPERLY to provide both the running and starting (surge) wattage of the devices you will be powering.
Power Load Planning & Management (cont’d) 12 Device Running Watts Device Running Watts Furnace fan (1/3 HP) 1200 (a) Submersible pump (1-1/2 HP) 2800 (a) Freezer 800 (b) Submersible pump (1 HP) .
Installation / Initial Set-Up 13 There are a number of important steps required to set up your generator for initial use. These steps are: Steps for Installation / Initial Se t-Up 1. Unpacking & delivery inspection. 2. Planning the power load to stay within the generator’s rated capacity.
Installation / Initial Set-Up 14 3. Gas Hook-up Installation fo r Natural Gas or LPG (if needed) You can power this generator with gasoline, natural gas (NG), or propane (LP) gas. The generator is designed so that it is easy to switch between fuel sources.
Installation / Initial Set-Up 15 ♦ This product is designed to operate at an LPG gas pressure range of 7” to 11” of water column and requires a minimum LPG gas flow rate of 9.33 lb/hr, 2.2 Gal/hr, or 201,718 BTU/hr. Note: All gas cylinders produce gas pressure in excess of 11 ” water column.
Installation / Initial Set-Up 16 4. Set-up either as a BUILDING BACK-UP or PORTABLE Power Source This generator is designed to provide up to 13,000W of electrical power. It ca n supply electricity in two ways: 1. As a back up, standby power source for a building.
Installation / Initial Set-Up 17 The generator cannot power your enti re home -- you must work with the installing electrician to determine which devices/appliances you wish to power during an outage. The electr ician can help you determine which circuits and devices can be powered simultaneously without overloading the generator.
Installation / Initial Set-Up 18 ♦ Extension cords may be used to pow er devices that are located at a distance from the generator. Howe ver, use only UL-listed, outdoor-rated, grounded extension cords of the proper size.
Installation / Initial Set-Up 19 5. Select a Suitable Site Before using the generator, you must select a suitable OUTDOOR location for installation and operation.
Installation / Initial Set-Up 20 • Never place the generato r imm ediately adjacent to a building or other structure – allow at least a 7’ clearance. • Do not run the generator in close proximity to other heat-generating equipment, such as another generato r.
Installation / Initial Set-Up 21 6. Grounding the generator Always ensure the generator is properly grou nded to prevent electrical shock. You must always ground the generator by the fo llowing method when using the generator as a portable electrical source: 1) Drive a ¾” or 1” copper pipe or rod into the ground close to the generator.
Installation / Initial Set-Up 22 8. Spark Arrestor Installation Installing the spark arrestor 1. Push spark arrestor into outlet pipe. 2. Attach the spark arrestor to the outlet pipe with screw as shown. (Screw is designed to drill through the outlet pipe.
Operation 23 Once you have set up your generator for use, it is time to start your generator. The following are the procedures necessa ry for safe, successful operation of your generator. Operation Procedures 1. General Safety Rules for Operation 2. Preparing for Operation 3.
Operation (cont’d) 24 be done by factory-authorized personnel. • External fuel sources . Never attempt to connect external gasoline/diesel sources in order to increase engine run time. Larger tank at pressure or higher elev ation will cause ga soline to le ak from carburetor during operation.
Operation (cont’d) 25 Static electricity and filling the gasoline tank: Static electricity can initiate from ungrounded gasoline tanks or containers, from flowing gasoline, and from persons carrying.
Operation (cont’d) 26 2. Preparing for Operation Position generator Position generator in accordance with the instructions g iven in “Installation & Initial Set-up, Step 5: Select a Suitable Site” of this manual. Operate outside only, on dry, level gr ound with adequate clearance and ventilation.
Operation (cont’d) 27 Fill gasoline tank (if using gasoline) Check the gasoline level in the generator’s tank if you will be operating the generator on gasoline. If needed, fill tank with fresh unleaded gasoline from a portable container, after first reading the warni ngs and instructions below.
Operation (cont’d) 28 generator’s tank is not grounded and high velocity flow from the pump can cause static electric ity build-up. Use an approved portable container to transfer gas to the generator’s tank. • Never fill the portable gas conta iner while it is sitting inside a vehicle, trailer, trunk, or pi ck-up truck bed.
Operation (cont’d) 29 Inspect Fuel System / Check for Leaks Inspect fuel system & check for le aks BEFORE starting generator. Do not start generator until all neede d repairs have been completed. WARNING: Fuel leak hazard Gasoline, LP gas (propane) and NG (natural gas) are highly explosive and fuel leaks can result in fire or explosions.
Operation (cont’d) 30 A djustmen t Scre w Lock Nut 3. Starting the Engine After you have completed the pre-start checklist procedures, you are ready to start the engine.
Operation (cont’d) 31 5) Under long, continuous-run operating conditions, be prepared to: a) Check engine oil level every 24 operating hours, b) Change oil after the first 20 opera ting hours, and at least every 100 operating hours thereafter, as direct ed in the engine owner’s manual.
Operation (cont’d) 32 4. Checking Generator Output Although the speed of the engine was carefully adjusted at the factory so that the generator produces the proper voltage and frequency, output voltage should be checked periodically to ensure the generator is working properly before connecting loads to the generator .
Operation (cont’d) 33 5. Connecting Loads You will want to be careful when connecting loads so as not to overload the generator, especially if you are powering devices with motors that require a higher starting power load.
Operation (cont’d) 34 6. Switching Fuels (during operation) You can switch fuel sources (from gasoline to LP /NG, or from LP/NG to gasoline) while the generator is running. Follow the instructions below: Switching from LP/NG to Gasoline 1. Disconnect all loads to the genera tor.
Operation (cont’d) 35 8. Storage & Exercise When you are finished using the generator, you must: o Disconnect all loads o Shut off fuel supply o Store the genera tor properly o Plan on exercising the engine regularly unless the generator is prepared for long-term storage.
Operation (cont’d) 36 Prepare engine for long term storage if needed If you will not be able to exercis e the generato r regularly, you must prepare the engine for long term storage to prevent gum deposits from forming and causing malfunction of the engine.
Maintenance & Repair 37 Inspect and maintain your generator as specified below in order to keep it in safe and optimal working order. Follow all safety ru les and recom mended maintenance steps. WARNING ALWAYS shut off the engine, disconnect the spark plug(s) and discharge the capacitor before cleaning, adjusting, or servicing the ge nerator.
Maintenance & Repair (cont’d) 38 Inspect fuel system / check for leaks Inspect the fuel system and check for leaks on a regular basis. 1) Inspect the entire fuel system.
Troubleshooting 39 TROUBLESHOOTING Problem Possible Causes Possible Remedies Engine will not start. a) Low oil level. b) Fouled spark plug. c) Out of fuel. d) Stop switch in OFF position. e) Battery disconnected or dead. f) Fuel selector switch is set to the incorrect fuel.
Summary of Importation Information for Operation 40 This section provides a summary of the various safety procedures and measures that have been presented throughout the manual. Keep this summ a ry handy and refer to it to refresh your memory about how to safely use your generator.
Summary of Importation Information for Operation cont’d 41 o When CONNECTING the battery, connect the RED cable to the POSITIVE terminal FIRST. o When DISCONNECTING the battery, disconnect the BLACK cable from the NEGATIVE terminal FIRST • Acid/skin contact.
Summary of Importation Information for Operation cont’d 42 • Spark arrestor . Equip engine with a spark a rrestor if generator will be us ed near any igni table forest, brush, or grassy land. See the “Specifications” sec tion of this manual to dete rmine if your generator is already equipped.
Summary of Importation Information for Operation cont’d 43 • Smell for gas before starting the generator: • Natural gas. Natural gas is lighter than air and tends to collect in hi gh areas. After opening NG line supply, smell for gas BEFORE starting engine.
Summary of Importation Information for Operation cont’d 44 contact with victim. Use a nonconducting im plement, su ch as a dry rope or board, to free the victim from the live conductor. Apply first aid and get im mediate medical help. • Hot muffler .
Generator Exploded View Rev – M.2 45.
Generator Exploded View Rev – M.2 46 Fig # Part # Description Qty 1 777149 Fuel Cap, With Gauge 1 2 38760 Fuel Tank Assembly 1 3 171410 Fuel Clamp 2 4 30754 Leather Washer 4 6 n/a Muffler 1 6a 78341.
Wiring Diagram Rev – M.2 47.
Wiring Diagram Rev – M.2 48 Diag # Part # Description Qty 1 306422 Twist Lock Receptacle, NEMA L14-30R 1 2 306426 Receptacle, 120 Vol t, 20 Amp, NEMA 5-20R 2 3 30643 Circuit Breaker, 20 Amp 2 4 3064.
Fuel Delivery System Rev – M.2 49 Diag # Part # Description Qty 1 82187 M6-1.0 X 65mm Socket Head Cap Screw, w/ thread locking patch 2 2 35846 Venturi 1 3 35847 Adapter 1 4 32808 Elbow 1 5 777119 Hose Clamp 2 6 37748 Regulator Wire Harness 1 7 35488 Oil Pressure Switch Wire Harness 1 8 777239 Protective Sleeve 13.
Generator Head Exploded View Rev – M.2 50 Ref # Part # Description Qty 1 30991 Drive End Bracket 1 2 30994 Protection Screen 2 3 31013 Phillips Screw 10 4 30995 Fan 1 5 307489 Grommet 1 6 305605 Terminal Box Cover 1 7 31014 M5 X .8, 16mm Long 2 8 31018 M5 X .
Limited Warranty 51 Dear Valued Customer: The NorthStar Product you just purchased is built with the finest material and craftsmanship. Use this product properly and enjoy the benefits from its high performance. By purchasing a NorthStar produc t, you show a desire for quality and durability.
52 Manufactured by Northern Tool + Equipment Co., 2800 SouthCross Drive West P.O. Box 1499 Burnsville, MN 55337-0499 ®.
Ein wichtiger Punkt beim Kauf des Geräts North Star M165939M.2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie North Star M165939M.2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für North Star M165939M.2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von North Star M165939M.2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über North Star M165939M.2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon North Star M165939M.2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von North Star M165939M.2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit North Star M165939M.2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei North Star M165939M.2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.