Benutzeranleitung / Produktwartung ASMB6-iKVM des Produzenten Asus
Zur Seite of 114
ASMB6-iKVM Server Management Board.
ii E6918 First Edition V1 January 2012 Copyright © 2012 ASUST eK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, tra.
iii Contents Contents ...................................................................................................... iii Notices ......................................................................................................... vi Safety information .
iv Contents 3.1.4 Displaying FRU information .......................................... 3-10 3.1.5 Displaying system event logs ......................................... 3-1 1 3.1.6 Using Remote Console ................................................
v Contents 4.4.6 Network Bond ............................................................... 4-13 4.4.7 NTP ............................................................................... 4-13 4.4.9 PEF ...............................................
vi Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received including interference that may cause undesired operation.
vii REACH Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulatory framework, we published the chemical substances in our products at ASUS website at http://csr .
viii Safety information Electrical safety • T o prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the server . • When adding or removing devices to or from the server , ensure that the power cables for the devices are unplugged before the signal cables are connected.
ix About this guide This user guide contains the information you need when installing and conguring the server management board. How this guide is organized This guide contains the following parts: • Chapter 1: Product introduction This chapter describes the server management board features and the new technologies it supports.
x T ypography Bold text Indicates a menu or an item to select. Italics Used to emphasize a word or a phrase. <Key> Keys enclosed in the less-than and greater-than sign means that you must press the enclosed key . Example: <Enter> means that you must press the Enter or Return key .
xi ASMB6-iKVM specications summary Chipset Aspeed 2300 Internal RAM 1 12 MB for system 16 MB for video Internal ROM 32 MB Timers 32-bit W atchdog T imer Main features IPMI 2.
xii.
1 Chapter 1: Product introduction This chapter describes the server management board features and the new technologies it supports..
1-2 Chapter 1: Product introduction 1.1 Welcome! Thank you for buying an ASUS ® ASMB6-iKVM server management board! The ASUS ASMB6-iKVM is an Intelligent Platform Management Interface (IPMI) 2.0-compliant board that allows you to monitor , control, and manage a remote server from the local or central server in your local area network (LAN).
ASUS ASMB6-iKVM 1-3 1.3 Features 1. IPMI 2.0 • System interface (KCS) • LAN interface (support RMCP+) • System Event Log (SEL) • Sensor Data Record (SDR) • Field Replaceable Unit (FRU) • R.
1-4 Chapter 1: Product introduction 1.4 System requirements Before you install the ASMB6-iKVM board, check if the remote server system meets the following requirements: • ASUS server motherboard with Baseboard Management Controller (BMC) connector* • LAN (RJ-45) port for server management** • Microsoft ® Internet Explorer 5.
ASUS ASMB6-iKVM 1-5 1.5 Network setup The ASMB6-iKVM server management board installed on the remote server connects to a local/central server via direct LAN connection or through a network hub. Below are the supported server management congurations.
1-6 Chapter 1: Product introduction.
2 Chapter 2: Installation This chapter provides instructions on how to install the board to the server system and install the utilities that the board supports.
2-2 Chapter 2: Installation 2.2 Hardware installation T o install the server management board: 1. Locate the ASMB6 connector on the motherboard. 2.1 Before you proceed T ake note of the following precautions before you install the server management board to the remote server system.
ASUS ASMB6-iKVM 2-3 4. When installed, the board appears as shown. 5. Insert the LAN cable plug to the LAN port for server management. Refer to the Appendix for the location of the LAN port for server management. 6. For direct LAN conguration, connect the other end of the LAN cable to the local/central server LAN port.
2-4 Chapter 2: Installation 2.3 Firmware update and IP conguration You need to update the ASMB6-iKVM rmware and congure IP source before you start using the ASMB6-iKVM board. 2.3.1 Firmware update T o update the rmware: 1. Insert the support CD into the optical drive.
ASUS ASMB6-iKVM 2-5 7. When the update process is completed, the following screen appears. Ne wIma geSi ze = 32MB , of fs = 0 Up load ing Fir mw are Imag e : Com plet ed Fl ash Upda te Co mple ted De vice Fir mwa re has bee n u pgra ded suc ce ssfu lly.
2-6 Chapter 2: Installation 2.3.2 Congure BMC IP source static IP 1. Repeat the step 1-4 in the previous sub-section. 2. On re boo t, th e mai n m en u app ear s. Se le ct Con gu re B MC IP So ur ce St ati c I P fo r L AN1 (o r DM _LA N1) , an d p res s < En te r> to ent er th e s ub- men u.
ASUS ASMB6-iKVM 2-7 2.3.3 Congure BMC IP source DHCP 1. Repeat the step 1-4 in the previous sub-section. 2. On re boo t, th e mai n m en u app ear s. Se le ct Con gu re B MC IP So ur ce DH CP fo r L AN1 (o r DM _LA N1) , an d p res s < En te r> to ent er th e s ub- men u.
2-8 Chapter 2: Installation 2.4 BIOS conguration Y ou need to adjust the settings in the BIOS setup of the remote server for correct conguration and connection to the central server . • Update the remote server BIOS le following the instructions in the motherboard/system user guide.
ASUS ASMB6-iKVM 2-9 Configuration Source [Previous State] Allows you to select the IP address source type. Set the LAN channel parameters statically or dynamically . The following items are available when you set Conguration Source to [Static]. Station IP Address Allows you to set the BMC IP address.
2-10 Chapter 2: Installation 2.4.3 System Event Log Allows you to view all the events in the BMC event log. It will take a maximum of 15 seconds to read all the BMC SEL records. SEL Components [Disabled] Allows you to enable or disable all features of system event log during booting.
ASUS ASMB6-iKVM 2-1 1 2.5 Running the ASMC6 utility Th e AS MC6 ut ili ty all ows y ou to up dat e the AS MB6 -iK VM rm war e, co n gur e t he LA N s ett ing f or the re mot e s erv er an d cha nge t he us er nam e/ pa ssw ord in D OS en vir onm ent .
2-12 Chapter 2: Installation ASMC6 Help Menu options Options Description -kcs[smic/bt/pci_smic] NetFn command data.... Send IPMI command -bmc_ip_source source[1: Static, 2: DHCP] Set the IP source -bmc_ip [ip_addr] (e.g., bmc_ip 10.10.10.20) Write the BMC IP address for dedicated LAN -bmc_mask [ip_mask] (e.
ASUS ASMB6-iKVM 2-13 2.5.1 Conguring the LAN controller Before you can establish connection to the ASMB6-iKVM board, you must congure the LAN port for server management used by the remote server to connect to the local/central server . T o congure the LAN port of the remote server: 1.
2-14 Chapter 2: Installation 2.5.2 Conguring the user name and password Y ou may change your user name and password from the ASMC6 utility . T o change the user name and password: 1. Follow steps 1-5 on page 2-1 1. 2. When the C:> prompt appears, type ASMC6 -user_name xxxxx , then press <Enter> to change the user name.
ASUS ASMB6-iKVM 2-15 2.6 Software installation Y ou can monitor , control, or manage the remote server from the local/central server using the ASUS Remote Console (ARC). The ARC is a web-based application available from the support CD that came with theASMB6-iKVM package.
2-16 Chapter 2: Installation 3. Follow the installation wizard instructions to install the utility . 2.6.2 Launching ARC T o launch the ARC utility , click Start > All Programs > ASUS Remote Console > ASUS Remote Console from the Windows ® desktop.
3 Chapter 3: ASUS Remote Console This chapter tells you how to use the ASUS Remote Console (ARC) that the server management board supports..
3-2 Chapter 3: ASUS Remote Console 3.1 ASUS Remote Console (ARC) The ASUS Remote Console (ARC) is a web-based utility , designed for ASMB6-SOL PLUS, that allows you to monitor the remote host’s hardware information including temperatures, fan rotations, voltages, and power .
ASUS ASMB6-iKVM 3-3 3.1.1 ARC sections Menu bar The Menu bar contains all the commands for the ARC application. Click on a menu to display a list of available commands. T ool bar The T ool bar buttons correspond to commonly used commands. The T ool bar offers faster access and execution of these commands.
3-4 Chapter 3: ASUS Remote Console Some remote server information (such as the SDR) contains several sensor groups such as T emperature , V oltage , and Fan . Click before the remote server information to display the sensor groups. Click before a sensor group to display individual sensors.
ASUS ASMB6-iKVM 3-5 Event window The Event window displays the Platform Event T rap (PET) received by the ARC. The PET information includes the event index, source IP address, enterprise, community , generic and specic traps, and time ticks. The PET information is a system management alert in SNMP Trap format and is used for IPMI alerting.
3-6 Chapter 3: ASUS Remote Console 3.1.2 Connecting to the remote server T o connect to the remote server: 1. From the menu bar , click Server , then select Add New Server Node . An Add new server connection window appears. 2. T ype the remote server name and IP address on the elds.
ASUS ASMB6-iKVM 3-7 The navig ation window disp lays the remot e serv er. Th e ava ilable rem ote se rver i nforma tion are dis played on th e Detail/SEL window . 4. Use any of these options to connect to the server: • Click before the remote server to display the remote server information, then select from the list.
3-8 Chapter 3: ASUS Remote Console 3.1.3 Retrieving sensor information The Sensor Data Record (SDR) provides remote server system information through available sensors including CPU/system/power temperatures, voltages, fan speeds, chassis intrusion, etc.
ASUS ASMB6-iKVM 3-9 3. Click More . A sensor window appears displaying additional information on the sensor . The Information tab displays basic sensor information including the sensor name, current status, current value, and sensor type. The tab also displays the sensor record ID and SDR version.
3-10 Chapter 3: ASUS Remote Console 3.1.4 Displaying FRU information The Field Replaceable Unit (FRU) information provides the manufacturer , product name, and/or serial number of various modules and components installed on the remote server . For example, the FRU feature can display the remote server motherboard name, model, and serial number .
ASUS ASMB6-iKVM 3-1 1 3.1.5 Displaying system event logs The System Event Log (SEL) is a non-volatile storage area where all remote server system events are stored for real-time tracking or later retrieval. The ARC application can display system events for efcient remote server monitoring and troubleshooting.
3-12 Chapter 3: ASUS Remote Console 3.1.6 Using Remote Console The Remote Console feature lets you see the remote server screen (text only) and is useful when you adjust the remote server BIOS settings. T o display the remote server console, press the Remote Console item from the navigation window .
ASUS ASMB6-iKVM 3-13 3.1.7 Displaying all remote server sensors T o display all remote server sensors in graphical format: 1. From the navigation window , click before the server name to open the remote server information. 2. Click All Sensors value .
3-14 Chapter 3: ASUS Remote Console 3.1.8 Adjusting the monitoring settings The ARC application allows you to adjust the remote server monitoring settings including SEL polling, SDR reading, and PET . T o adjust the monitoring settings: 1. Click Server on the menu bar , then select General Setting from the drop-down menu.
ASUS ASMB6-iKVM 3-15 Enabling the Short Message Service (SMS) feature The Short Message Service or SMS feature allows you to receive Platform Event T rap (PET) information on your smart phone (ASUS P505). Y ou must install Microsoft ® ActiveSync ® before you enable the SMS feature.
3-16 Chapter 3: ASUS Remote Console 3.1.9 Controlling the remote server power ARC allows you to power up, power down, or reset the remote server using the power menu. 2. Click Y es when the Conrm power down window appears. 3. The remote server is turned off.
ASUS ASMB6-iKVM 3-17 3.1.10 Viewing PET information The Platform Event T rap or PET is an SNMP trap used for system management alerts. When the ARC receives a PET , it displays a pop-up window notifying you of the alert and its source (IP address). Right-click the window to close.
3-18 Chapter 3: ASUS Remote Console 4. Double-click Management and Monitoring T ools . 5. Select Simple Network Management Protocol (SNMP). 6. Click OK .
ASUS ASMB6-iKVM 3-19 Important notice for Windows ® XP (Service Pack 2) users If the local server system is behind a rewall, you must create a UDP port to receive PET information. T o create a UDP port: 1. Double-click the My Computer icon from the Windows ® desktop, then click the My Network Places link.
3-20 Chapter 3: ASUS Remote Console 3 . 2 A S U S H o s t M a n a g e m e n t C o n t r o l l e r S e t u p The ASUS Host Management Controller Setup utility provides precise conguration and basic functions including System Event Log (SEL) generation and System Data Record (SDR) reading in DOS mode.
ASUS ASMB6-iKVM 3-21 3.2.2 Command elds The utility menu bar has ve commands: Initial, View , Set, Monitor and Help. Y ou can select a command using the left or right arrow button on the keyboard. After selecting a command, use the down arrow key to display available options.
3-22 Chapter 3: ASUS Remote Console T o view the System Event Log (SEL): 1. Select BMC SEL from the View command option, then press <Enter>. A complete list of system event records appear on the left pane. The right pane displays the SEL information.
ASUS ASMB6-iKVM 3-23 T o view the System Data Record (SDR): 1. Select BMC SDR from the View command option, then press <Enter>. A complete list of data records appears on the left pane.
3-24 Chapter 3: ASUS Remote Console 3.2.5 Set Th e S et com ma nd co ntr ol s the ho st in te rfa ce typ e and th e c orr ect BM C t im e. T o view the BMC information: 1. Select BMC Info from the View command option, then press <Enter>. A list of BMC information appears on the left pane.
ASUS ASMB6-iKVM 3-25 Y ou can select from the following interfaces: KCS Interface - Keyboard Controller Style SMIC Interface - Server Management Interface Chip BT Interface - Block T ransfer PCI Interface - Peripheral Component Interconnect KCS2 Interface - Keyboard Controller 2 Style 3.
3-26 Chapter 3: ASUS Remote Console 3.2.6 Monitor The Monitor command displays real-time data on the remote server system and CPU temperatures, voltages, and fan speeds. T o display a remote server information: 1. Select a sensor from the Monitor command options, then press <Enter>.
ASUS ASMB6-iKVM 3-27 3.2.7 Help The Help command displays the available utility options, utility version, and copyright information. ASUS Host Management Controller Setup Menu No Support Initial View .
3-28 Chapter 3: ASUS Remote Console.
4 Web-based user interface This chapter tells you how to use the web-based user interface that the server management board supports..
4-2 Chapter 4: Web-based user interface 4.1 Web-based user interface The web-based user interface allows you to easily monitor the remote server ’s hardware information including temperatures, fan rotations, voltages, and power . This application also lets you instantly power on/off or reset the remote server .
ASUS ASMB6-iKVM 4-3 4.1.2 Using the utility The web-based graphics user interface displays when you login in the utility successfully . 1. Menu bar: Click a menu to display available function lists. 2. Function list: Click each function key to start using its specic functions.
4-4 Chapter 4: Web-based user interface 4.2 FRU Information This section contains detailed information for various FRU deviced present in this system. 4.3 Server Health This section contains the data related to the server health, such as the Sensor Readings, Event log and System and Audit Log.
ASUS ASMB6-iKVM 4-5 4.3.1 Sensor Readings (with Thresholds) The Sensor Readings page displays the system sensor information, including readings and status. 1 2 3 1. Select a sensor type category: Allows you to select the type of sensor readings to be displayed in the list.
4-6 Chapter 4: Web-based user interface 4.4 Conguration This section allows you to congure the system settings. Click each function key to start using its specic functions 4.
ASUS ASMB6-iKVM 4-7 Procedure: Entering the details in Advanced Active Directory Settings Page 1. Click on Advanced Settings to open the Advanced Active Directory Settings Page. 2. In the Active Directory Settings Page, enter the following details. 3.
4-8 Chapter 4: Web-based user interface T o add a new Role Group 1. In the Active Directory Settings Page, select a blank row and click Add Role Group to open the Add Role group Page as shown in the screenshot below . 2. In the Role Group Name eld, enter the name that identies the role group in the Active Directory .
ASUS ASMB6-iKVM 4-9 4.4.2 DNS The page allows you to manage DNS settings of the device. 1 2 3 4.4.3 LDAP The Lightweight Directory Access Protocol (LDAP) is an application protocol for querying and modifying data of directory services implemented in Internet Protocol (IP) networks.
4-10 Chapter 4: Web-based user interface 2. Add Role Group : T o add a new role group to the device. Alternatively , double click on a free slot to add a role group. 3. Modify Role Group : T o modify the particular role group. 4. Delete Role Group : T o be delete a role group from the list.
ASUS ASMB6-iKVM 4-1 1 T o add a new Role Group 1. In the LDAP Settings Page, select a blank row and click Add Role Group to open the Add Role group Page as shown in the screenshot below . 2 In the Role Group Name eld, enter the name that identies the role group.
4-12 Chapter 4: Web-based user interface 4.4.4 Mouse Mode The Mouse Mode page allows you to select the mouse mode. 1 1. Save: Select the desired mouse mode, and then click Save to apply the setting. 4.4.5 Network The Network page allows you to congure the network settings.
ASUS ASMB6-iKVM 4-13 4.4.6 Network Bond This page allows you to enable or disable networking bonding feature and congure the default interfaces. 4.4.7 NTP This page allows you to congure the NTP server or view and modify the device’ s Date and T ime settings.
4-14 Chapter 4: Web-based user interface 4.4.9 PEF Platform Event Filtering (PEF) provides a mechanism for conguring the BMC to take selected actions on event messages that it receives or has internally generated. These actions include operations such as system power-of f, system reset, as well as triggering the generation of an alert.
ASUS ASMB6-iKVM 4-15 Procedure: 1. Click the Event Filter T ab to congure the event lters in the available slots 2. T o Add an Event Filter entry , select a free slot and click Add to open the Add event Filter entry Page. A sample screenshot of Add Event Filter Page is in seen the screenshot below .
4-16 Chapter 4: Web-based user interface Alert Policy T ab This page is used to congure the Alert Policy and LAN destination. Y ou can add, delete or modify an entry in this page. The elds of PEF Management – Alert Policy T ab are explained below .
ASUS ASMB6-iKVM 4-17 7. Add: T o save the new alert policy and return to Alert Policy list. 8. Modify: T o modify the existing entries. 9. Cancel: T o cancel the modication and return to Alert Policy list. Procedure: LAN Destination has to be congured under Conguration->PEF->LAN Destination.
4-18 Chapter 4: Web-based user interface 9. In the Alert String eld, enable the check box if the Alert policy entry is Event Specic. 10. In the Alert String Key eld, choose any one value that is used to look up the Alert String to send for this Alert Policy entry .
ASUS ASMB6-iKVM 4-19 PEF Management LAN Destination Page This page is used to congure the Event lter , Alert Policy and LAN destination. A sample screenshot of PEF Management LAN Destination Page is given below . The elds of PEF Management – LAN Destination T ab are explained below .
4-20 Chapter 4: Web-based user interface Procedure: 6. Select the User Name from the list of users. 7. In the Subject eld , enter the subject. 8. In the Message eld , enter the message. 9. Click Add to save the new LAN destination and return to LAN destination list.
ASUS ASMB6-iKVM 4-21 4.4.10 RADIUS This page is used to enable or disable RADIUS authentication and enter the required information to access the RADIUS server . 4.4.1 1 Remote Session The Remote Session page allows you to enable or disable encryption on KVM or data during the redirection session.
4-22 Chapter 4: Web-based user interface 4.4.12 Services This page lists services running on the BMC. It shows current status and other basic information about the services. Press Modify to modify the services conguration. 4.4.13 SMTP The SMTP page allows you to congure SMTP mail server .
ASUS ASMB6-iKVM 4-23 4.4.14 SSL The Secure Socket Layer protocol was created by Netscape to ensure secure transactions between web servers and browsers. The protocol uses a third party , a Certicate Authority (CA) , to identify one end or both end of the transactions.
4-24 Chapter 4: Web-based user interface The elds of SSL Certicate Conguration – Upload SSL tab are explained below . 1. Current Certicate: Current certicate information will be displayed (read- only). 2. New Certicate: Certicate le should be of pem type 3.
ASUS ASMB6-iKVM 4-25 2. Organization(O): Organization name for which the certicate is to be generated. - Maximum length of 64 characters. - Special characters '#' and '$' are not allowed. 3. Organization Unit(OU): Over all organization section unit name for which certicate is to be generated.
4-26 Chapter 4: Web-based user interface The elds of SSL Certicate Conguration – Generate SSL tab are explained below . 1. Basic Information: This section displays the basic information about the uploaded SSL certicate. It displays the following elds.
ASUS ASMB6-iKVM 4-27 • Organization Unit(OU) • City or Locality(L) • State or Province(ST) • Country(C) • Email Address Procedure 1. Click the Upload SSL T ab, Browse the New Certicate and New Privacy key . 2. Click Upload to upload the new certicate and privacy key .
4-28 Chapter 4: Web-based user interface 4.4.15 Users The User Management page allows you to view the current list of user slots for the server . Y ou can add a new user and modify or delete the existing users. T o open User Management page, click Conguration > Users from the main menu.
ASUS ASMB6-iKVM 4-29 5 Enable or Disable the User Access Privilege. 6. In the Network Privilege eld, enter the network privilege assigned to the user which could be Administrator , Operator , User or No Access. 7. Check the SNMP Status check box to enable SNMP access for the user .
4-30 Chapter 4: Web-based user interface 4.5 Remote Control This section allows you to perform remote operations on the server . Click each function key to start using its specic functions 4.
ASUS ASMB6-iKVM 4-31 Java Console: This is an OS independent plug-in which can be used in Windows as well as Linux with the help of JRE. JRE should be installed in the client’s system. Y ou can install JRE from the following link. http://www .java.com/en/download/manual.
4-32 Chapter 4: Web-based user interface Video This menu contains the following sub menu items. 1. Pause redirection: This option is used for pausing Console Redirection. 2. Resume Redirection: This option is used to resume the Console Redirection when the session is paused.
ASUS ASMB6-iKVM 4-33 Keyboard This menu contains the following sub menu items. 1. Hold Right Ctrl Key: This menu item can be used to act as the right-side <CTRL> key when in Console Redirection. 2. Hold Right Alt Key: This menu item can be used to act as the right-side <AL T> key when in Console Redirection.
4-34 Chapter 4: Web-based user interface Mouse 1. Show Cursor: This menu item can be used to show or hide the local mouse cursor on the remote client system. 2. Mouse Calibration: This menu item can be used only if the mouse mode is relative. In this step, the mouse threshold settings on the remote server will be discovered.
ASUS ASMB6-iKVM 4-35 Options Band width: The Bandwidth Usage option allows you to adjust the bandwidth. Y ou can select one of the following: 1. Auto Detect: This option is used to detect client system keyboard layout automatically and send the key event to the host based on the Layout detected.
4-36 Chapter 4: Web-based user interface Media Virtual Media W izard: T o add or modify a media, select and click 'Virtual Media Wizard' button, which pops out a box named “Virtual Media” where you can congure the media. A sample screenshot of Virtual media screen is given below .
ASUS ASMB6-iKVM 4-37 Keyboard Layout Auto Detect: This option is used to detect keyboard layout automatically . The languages supported automatically are English – US, French – France, Spanish – Spain, German- Germany , Japanese- Japan.
4-38 Chapter 4: Web-based user interface 4.5.2 Server Power Control The Server Power Control page displays the current server power status and allows you to change the current settings. Select the desired option, and then click Perform Action to execute the selected action.
ASUS ASMB6-iKVM 4-39 4.5.4 Power Button The Power Button page allows you to enable or disable power button and click Perform Action to conrm the selection.
4-40 Chapter 4: Web-based user interface 4.6 Maintenance This section allows you to perform the rmware update for the remote server . Y ou can also use Restore Factory Defaults to reset system settings and use System Admnistrator to enable or disable access and change the password for the administrator account.
ASUS ASMB6-iKVM 4-41 4.6.2 Restore Factory Default This section allows you to restore all settings to factory default. Please click the Restore Factory to reset all settings.
4-42 Chapter 4: Web-based user interface.
A Appendix: Reference information The Appendix shows the location of the LAN ports for server management and BMC connector on server motherboards. This section also presents common problems that you may encounter when installing or using the server management board.
A-2 Appendix: Reference information A.1 BMC connector The ASUS server motherboards that support the ASMB6-iKVM comes with a Baseboard Management Controller (BMC) connector . Refer to the illustration below to locate the BMC connector on different server motherboards.
ASUS ASMB6-iKVM A-3 A.2 LAN ports for server management The ASUS server motherboards that support the ASMB6-iKVM comes with three LAN (RJ-45) ports: one for network connection and the other two for server management. For easy identication, the LAN ports for server management are LAN1 and DM_LAN1 ports.
A-4 Appendix: Reference information A.3 Troubleshooting Problem Solution Th e l ocal /ce ntr al ser ve r c anno t c onn ect to th e ASM B6- iKV M boa rd 1. Check if the LAN cable is connected to the LAN port. 2. Make sure that the IP address of both the remote and local/central servers are on the same subnet.
ASUS ASMB6-iKVM A-5 A.4 Sensor Table Memory ECC Sensor No. Sensor Name Sensor T ype Sensor T ype code Sensor V alue or Event Type Event Data 3 0xD1 CPU1_ECC1 Memory ECC Sensor 0x0C Discrete(0x6F) 0x01.
A-6 Appendix: Reference information Backplane HD Sensor No. Sensor Name Sensor T ype Sensor T ype Code Sensor V alue or Event T ype 0x68 Backplane1 HD1 Drive Slot 0x0D Discrete(0x6F) 0x01: Drive Prese.
ASUS ASMB6-iKVM A-7 Power Supply Sensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event T ype 0x81 PSU1 T emp T emperature 0x01 Threshold(0x01) Upper Non-Critical - going high Upper.
A-8 Appendix: Reference information Hardware Monitor Sensor No. Sensor Name Sensor T ype Sensor T ype Code Sensor V alue or Event T ype 0x31 CPU1 T emperature T emperature 0x01 Threshold(0x01) Upper N.
ASUS ASMB6-iKVM A-9 0x40 +3.3VSB V oltage 0x02 Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high 0x42 P1DDR3 (For AM.
A-10 Appendix: Reference information 0xA2 FRNT_F AN1 F AN 0x04 Threshold(0x01) Lower Non-critical - going low Lower Critital - going low 0xA3 FRNT_F AN2 F AN 0x04 Threshold(0x01) Lower Non-critical - .
Ein wichtiger Punkt beim Kauf des Geräts Asus ASMB6-iKVM (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Asus ASMB6-iKVM noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Asus ASMB6-iKVM - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Asus ASMB6-iKVM reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Asus ASMB6-iKVM erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Asus ASMB6-iKVM besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Asus ASMB6-iKVM verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Asus ASMB6-iKVM. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Asus ASMB6-iKVM gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.