Benutzeranleitung / Produktwartung N8580-31 des Produzenten NEC
Zur Seite of 15
NEC 500 UPS Uninterruptible Power Suppl y 100 VA C Use r ’s Manual 990-5021, Revision 1, 12/98 N8580-31.
i Important! Please read and save this manual. It provides installation and operating instructions that will help you get the fullest performance and service life from your UPS.
ii Table of Contents About Your New UPS .................................................................................................................................................... i 1. Safety ..................................................
1 1. Safety.
2 2. Attention from the Safety Point of View This section contains important instructions that should be followed during installation and maintenance of the NEC 500 and batteries. It is intended for customers who setup, install, relocate, or maintain APC equipment.
3 3. Attention from the Operational and Maintenance Points of View Please charge the battery. The battery may not be fully charged when your UPS arrives. Please allow four to six hours for charging. To turn off the UPS, set the Enable switch to OFF. Pressing the Off button, does not turn off the UPS.
4 5. Name and Function of Parts 1) Front View 5 0 0 With the UPS plugged in, press and release the large upper on/test button to supply power to the loads. The loads are immediately powered while the UPS beeps and performs a self-test . Press and release the small, lower off button to turn off power to the loads.
5 Replace Battery If the battery fails a self-test, the UPS emits short beeps for one minute and the replace battery LED illuminates. The UPS repeats the alarm every five hours. Perform the self-test procedure to confirm replace battery conditions. The alarm stops when the battery passes the self-test.
6 2) Rear View 500 V A Computer Interface Port Power management software and interface kits can be used with this UPS. Use only kits supplied or approved by the manufacturer. If used, connect the interface cable to the 9-pin computer interface port on the back panel of the UPS.
7 7. Operating Instructions With the UPS plugged in, press and release the large upper on/test button to supply power to the loads. Press and release the small, lower off button to turn off power to the loads. Note: Whenever the UPS is plugged in and utility voltage is present, the charger maintains battery charge.
8 8. Function Self-test The UPS performs a self-test automatically when turned on with the enable switch (by default). Automatic self-test eases maintenance requirements by eliminating the need for periodic manual self-tests. During the self-test, the UPS briefly operates the loads on-battery.
9 9. Abnormal Conditions and Protection Functions Smart Boost / Smart Trim The SmartBoost LED comes on to indicate that the UPS is compensating for a low voltage . The SmartTrim LED comes on to indicate that the UPS is compensating for a high voltage .
10 10. Troubleshooting Use the chart below to solve minor UPS installation problems. Contact NEC Technical Support Staff for assistance with complex UPS problems. Problem and Possible Cause Solution UPS will not turn on. • On/test button not pushed.
11 11. Maintenance and Checks Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least 4 hours. Extended storage • At -15 to +30 ° C (+5 to +86 ° F), charge the UPS’s battery every 6 months.
12 Specifications N8580-31 500 VA Acceptable input voltage 0 - 160 VAC Output voltage 90 - 110 VAC Input Protection Resettable circuit breaker Frequency limits (on-line operation) 50 or 60 Hz, +2%, -4% Transfer time 2 ms (normal) 4 ms (maximum) Maximum load 500 VA / 320 W On-battery output voltage 100 VAC On-battery frequency 50 or 60, ± 0.
Ein wichtiger Punkt beim Kauf des Geräts NEC N8580-31 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie NEC N8580-31 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für NEC N8580-31 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von NEC N8580-31 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über NEC N8580-31 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon NEC N8580-31 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von NEC N8580-31 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit NEC N8580-31. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei NEC N8580-31 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.