© Copyright 1989, 1994 National Instruments Corporation. All Rights Reserved. GPIB-BUF User Manual February 1994 Edition Part Number 320125-01.
National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, TX 78730-5039 (512) 794-0100 Technical support fax: (800) 328-2203 (512) 794-5678 Branch Offices: Australia (03) 879 9422, Austria (0662) 435986, Belgium 02/757.
MicroGPIB Products National Instruments has developed the MicroGPIB product line to offer a series of high performance, low cost IEEE 488 support items that are packaged in small all-metal cases, capable of being rack mounted.
action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunc.
FCC/DOC Radio Frequency Interference Compliance This equipment generates and uses radio frequency energy and, if not installed and used in strict accordance with the instructions in this manual, may cause interference to radio and television reception.
There is no guarantee that interference will not occur in a particular installation. However, the chances of interference are much less if the equipment is installed and used according to this instruction manual.
© National Instruments Corp. v i i GPIB-BUF User Manual Contents About This Manual .......................................................................... i x Introduction to the GPIB-BUF .................................................. . i x Organization of This Manual .
Contents GPIB-BUF User Manual v i i i © National Instruments Corp. Appendix A Hardware Specifications .............................................................. A -1 Appendix B Customer Communication ..............................................
© National Instruments Corp. i x GPIB-BUF User Manual About This Manual Introduction to the GPIB-BUF The GPIB-BUF is one of National Instruments family of MicroGPIB products. These products are high-performance, low-cost IEEE 488 support items, packaged in small all-metal cases, capable of being rack mounted.
About This Manual GPIB-BUF User Manual x © National Instruments Corp. Conventions Used in This Manual The following conventions are used in this manual. italic Italic text denotes emphasis, a cross reference, or an introduction to a key concept. bold italic Bold italic text denotes a note, caution, or warning.
© National Instruments Corp. 1 -1 GPIB-BUF User Manual Chapter 1 Description of the GPIB-BUF This chapter contains general information about the National Instruments GPIB-BUF and lists components and accessories.
Description of the GPIB-BUF Chapter 1 GPIB-BUF User Manual 1 -2 © National Instruments Corp. The GPIB-BUF has two isolated GPIB ports and is placed in-line between a GPIB system and a single, slower GPIB device (usually a printer or plotter). The GPIB-BUF automatically buffers all device-dependent data sent to the slower device.
Chapter 1 Description of the GPIB-BUF © National Instruments, Corp. 1 -3 GPIB-BUF User Manual The GPIB-BUF Front Panel The power switch and six Light Emitting Diodes (LEDs) are mounted on the GPIB-BUF front panel. Figure 1-2 shows the front panel of the GPIB -BUF.
Description of the GPIB-BUF Chapter 1 GPIB-BUF User Manual 1 -4 © National Instruments Corp. The GPIB-BUF Rear Panel Figure 1-3 shows the power cable and the GPIB cables connected to the rear panel of the GPIB-BUF. Figure 1-3. The GPIB-BUF Rear Panel The GPIB Connectors The GPIB-BUF has two GPIB connectors labeled GPIB IN and GPIB OUT.
Chapter 1 Description of the GPIB-BUF © National Instruments, Corp. 1 -5 GPIB-BUF User Manual The port labeled GPIB IN is intended to be connected to a GPIB system that includes one or more GPIB devices which send data to the GPIB target device.
© National Instruments Corp. 2 -1 GPIB-BUF User Manual Chapter 2 Installation and Operation This chapter describes the procedures for installing and operating the GPIB -BUF.
Installation and Operation Chapter 2 GPIB-BUF User Manual 2 -2 © National Instruments Corp. Installation Install the GPIB-BUF according to the following procedure. 1 . Inspect the GPIB-BUF. 2 . Verify the voltage requirement. 3 . Configure th e operating parameters.
Chapter 2 Installation and Operation © National Instruments Corp. 2 -3 GPIB-BUF User Manual Step 3. Configure the Operating Parameters The GPIB-BUF is shipped from the factory configured to operate at a GPIB primary address of 5 with the SRQ-on-empty function disabled and device clear recognition and pass through enabled.
Installation and Operation Chapter 2 GPIB-BUF User Manual 2 -4 © National Instruments Corp. Set Configuration Switches Use the DIP switch at location U38 on the printed circuit board to configure the GPIB primary address and operating modes of the GPIB-BUF.
Chapter 2 Installation and Operation © National Instruments Corp. 2 -5 GPIB-BUF User Manual Table 2-2. Configuration Parameters for Switches 4 through 8 Switches 4567 8 Indication OF F OF F OF F OF F.
Installation and Operation Chapter 2 GPIB-BUF User Manual 2 -6 © National Instruments Corp. Table 2-2. Configuration Parameters for Switches 4 through 8 (Continued) Switches 4567 8 Indication O N O F.
Chapter 2 Installation and Operation © National Instruments Corp. 2 -7 GPIB-BUF User Manual Step 5. Power on the Unit Power on your target device then power on your GPIB-BUF by using the front panel rocker switch. The POWER LED should light immediately and the READY indicator should blink while the unit executes its power-on self-test.
© National Instruments Corp. 3 -1 GPIB-BUF User Manual Chapter 3 Technical Information This chapter contains a more detailed description of the operation of the GPIB-BUF. The timing characteristics of the parallel port are provided in this chapter. The GPIB-BUF is actually a powerful 8-bit microcomputer tailored for use as an IEEE 488 data buffer.
Technical Information Chapte r 3 GPIB-BUF User Manual 3 -2 © National Instruments Corp. If the SRQ-on-empty feature is enabled, the GPIB-BUF asserts the Service Request (SRQ*) signal on the GPIB IN port. The SRQ condition can be used to signal the GPIB Controller that the GPIB-BUF is powered on and ready to accept data.
Chapter 3 Technical Information © National Instruments Corp. 3 -3 GPIB-BUF User Manual DMA Controller transfers the data directly to the internal data buffer without processor intervention. Thus, GPIB transfer rates as high as 900 kbytes/s are possible.
Technical Information Chapte r 3 GPIB-BUF User Manual 3 -4 © National Instruments Corp. When receiving data while addressed as a GPIB Listener, the GPIB-BUF buffers the state of the EOI* signal line along with the data byte it corresponds to using an additional on-board RAM module.
Chapter 3 Technical Information © National Instruments Corp. 3 -5 GPIB-BUF User Manual Polling the GPIB-BUF The GPIB-BUF can return status information to the GPIB Controller through the serial poll response byte as shown in Figure 3-1.
Technical Information Chapte r 3 GPIB-BUF User Manual 3 -6 © National Instruments Corp. The GPIB-BUF SRQ-on-empty feature and serial poll status byte are useful for several reasons. • A remote Controller is able to tell when a data transfer to a plotter or printer is completely finished.
Chapter 3 Technical Information © National Instruments Corp. 3 -7 GPIB-BUF User Manual Internally, the local Individual Status (ist) bit of the GPIB-BUF is reset to 0 when the internal data buffer is empty of data. It is set to 1 when the internal data buffer is not empty.
Technical Information Chapte r 3 GPIB-BUF User Manual 3 -8 © National Instruments Corp. Special Note About Timeouts If your current GPIB system relies on a timeout method to ensure a non- functioning.
Chapter 3 Technical Information © National Instruments Corp. 3 -9 GPIB-BUF User Manual internal data buffer. This mode can be used to prematurely abort a lengthy plot or print. Neither Group Execute Trigger (GET), Go To Local (GTL), nor Local Lockout (LLO) have any effect on the GPIB-BUF.
Chapter 1 Description of the GPIB-232CV © National Instruments Corp. 1 -1 GPIB-232CV User Manual Appendix A Hardware Specifications This appendix lists the electrical, environmental, and physical specifications of the GPIB-BUF.
Hardware Specifications Appendix A GPIB-BUF User Manual A -2 © National Instruments Corp. Table A-3. Physical Characteristics Characteristic Specification Case Size 1.6 in. by 5.7 in. by 8.4 in. (40.6 mm by 144.8 mm by 213.4 mm) Case Material All metal enclosure Rack Mounting Single or dual kits available Weight 28 oz.
© National Instruments Corp. B -1 GPIB-BUF User Manual Appendix B Customer Communication For your convenience, this appendix contains forms to help you gather the information necessary to help us solve technical problems you might have as well as a form you can use to comment on the product documentation.
Technical Support Form Technical support is available at any time by fax. Include the information from your configuration form. Use additional pages if necessary.
The problem is List any error messages The following steps will reproduce the problem.
Hardware Configuration Form Record the settings and revisions of your hardware on the line to the right of each item. Update this form each time you revise your hardware configuration, and use this form as a reference for your current configuration.
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: GPIB-BUF User Manual Edition Date: February 1994 Part Number: 320125-01 Please comment on the completeness, clarity, and organization of the manual.
If you find errors in the manual, please record the page numbers and describe the errors. Thank you for your help. Name Title Company Address Phone ( ) Mail to: Technical Publications National Instrum.
© National Instruments Corp. G- 1 GPIB-BUF User Manual Glossary Prefix Meaning Value µ - micro 10 -6 m- milli- 10 -3 k- kilo- 10 3 M- mega- 10 6 ° degrees % percent A amperes A C alternating curren.
Ein wichtiger Punkt beim Kauf des Geräts National Instruments GPIB-BUF (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie National Instruments GPIB-BUF noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für National Instruments GPIB-BUF - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von National Instruments GPIB-BUF reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über National Instruments GPIB-BUF erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon National Instruments GPIB-BUF besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von National Instruments GPIB-BUF verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit National Instruments GPIB-BUF. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei National Instruments GPIB-BUF gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.