Benutzeranleitung / Produktwartung GEM-P1632 des Produzenten Napco Security Technologies
Zur Seite of 16
R INS TALLATION INS TALLATION INST RUCTIONS INST RUCTIONS GEM-RP3DGT L Digital Ke ypad W I982A 6/99 © Napco 1999 Quick Start: 1. Referring to the control panel wiring diagram, connect siren, aux. power, pgm. output, remote bus, earth ground, zone and telephone wiring.
2.
INTRODUCTION The GEM-RP3DGTL is a dual 7-segment digital keypad that is compat ible with the NAPCO GEM-Series GEM-P816, P1632, P3200 & P9600 control-panels.
EASY PROGRAM MODE OVERVIEW ENTERING THE EASY KEYPAD PROGRAM MODE 1 Enter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code if programmed and press A 2 Press NO ( F ) repeatedly until function “ 17 “ (Activate Program Mode) is displayed.
Total Number of Zones in Area 1 (Appears for New Panel Only) Press the A button and then directly enter the total number of zones to be programmed for Area 1. Valid entries are from 01 to 32. Directly enter the total number of zones, including leading zeros.
Entry/Exit Zones in Area 1 (Appears for New Panel Only) Press the A button and then directly enter the zone number of any zones which are to be used as Entry/Exit zones. Valid entries are from 01 to 32. Di- rectly enter each zone number, including leading zeros.
7 Central Station Receiver 1 Format From the table below, enter the central station's receiver format. Use number buttons 1 through 9 . NOTE: Press G0 for a zero and 0 for a blank space (•). Press G 1 through G 4 for letters B–E, respectively.
RF Transmitter Programming (For wireless systems only. Also see Quick Method, which follows) Press the A button and for each transmitter (key fob transmitters also), then directly enter: 1 The zone number (01–32) to which the transmitter will be mapped, including leading zeros.
9 Key Fob Transmitters Keyfobs can be programmed as “Arm/Disarm” devices using the ON and OFF buttons (refer to control panel installation instructions). Press the A button and for each Key Fob Transmitter, enter: 1 The Key Fob Transmitter number (01–15).
Total Number of Zones and Keypads in Area 1. Total Number of Zones and Keypads in Area 2. (Appears for New Panel Only) 1 Press the A button and then press 3 to select the total number of zones to be programmed for Area 1. Valid entries are from 08 to 24 in multiples of 4.
11 Central Station Receiver 1 Format From the table below, enter the central station's receiver format. Use number buttons 1 through 9 . NOTE: Press G0 for a zero and 0 for a blank space (•). Press G 1 through G 4 for letters B–E, respectively.
12 RF Transmitter Programming (For wireless systems only. Also see Quick Method, which follows) Press the A button and for each transmitter and directly enter: 1 The zone number (01–96) to which the transmitter will be mapped, including leading zeros.
Key Fob Transmitters Keyfobs can be programmed as “Arm/Disarm” devices using the ON and OFF buttons (refer to control panel installation instructions). Press the A button and for each Key Fob Transmitter, enter: 1 The Key Fob Transmitter number (01–15).
DIRECT ADDRESS PROGRAM MOD E This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the Keypad Programming Worksheets contained in the control panel programming guide. Refer to these worksheets to identify the 4-digit location (address) of the feature to be programmed.
15.
NAPCO SECURITY SYSTEMS, INC. (NAPCO) war- rants its products to be free from manufacturing defects in materials and workmanship for thirty-six months fol- lowing the date of manufacture. NAPCO will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original pur- chaser or user.
Ein wichtiger Punkt beim Kauf des Geräts Napco Security Technologies GEM-P1632 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Napco Security Technologies GEM-P1632 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Napco Security Technologies GEM-P1632 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Napco Security Technologies GEM-P1632 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Napco Security Technologies GEM-P1632 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Napco Security Technologies GEM-P1632 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Napco Security Technologies GEM-P1632 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Napco Security Technologies GEM-P1632. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Napco Security Technologies GEM-P1632 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.