MultiModem ® ISI ISI9234HPCIE Server Card User Guide.
MULTIMODEM® ISI SERVER CARD USER GUIDE MultiModem ® ISI Server Card User Guide Model: ISI9234HPCIE Part Number: S000581, Version 1.1.3 Copyright This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of Multi-Tech Systems, Inc.
CONTENTS Contents Product Overview .................................................................................................................................................... 5 Product Overview.................................................
CONTENTS Environmental Information .................................................................................................................................... 24 Waste Electrical and Electronic Equipment Statement ............................
PRODUCT OVERVIEW Product Overview Product Overview The MultiModem ISI server cards and modems provide four built-in V.92/56K modems on an industry-standard PCI Express x1 architecture for analog dial-up or dedicated fax servers. It also offers V.34/33.
PRODUCT OVERVIEW Documentation Download documentation from www.multitech.com/setup/product.go. MultiModem ISI ISI9234HPCIE User Guide This document. Provides specifications, safety and regulatory information, installation, and configuration information (part number S000581).
PRODUCT OVERVIEW Specifications Category Description General Bus Type PCI Express form factor 1x, PCIe 1.0 compatible. Interrupt Request One IRQ per card (can be shared) Speed Baud Rates 300 bps to 230 Kbps per port Physical Description Weight 0.45 lbs.
PRODUCT OVERVIEW Dimensions Dimensions with Standard Bracket 8 MultiModem ® ISI ISI9234HPCIE Server Card User Guide.
PRODUCT OVERVIEW Dimensions with Low Profile Bracket Power Measurements Sleep Typical Maximum Peak Total Inrush Total Inrush Charge Charge measured in Duration Millicoulombs during (mC) Powerup 3.3 volts Current (AMPS) 0.402 0.541 0.550 0.592 16.00 26mS Watts 1.
SAFETY NOTICES Safety Notices Analog Telecom Safety Warnings Before servicing, disconnect this product from its power source and telephone network. Also: ■ Never install telephone wiring during a lightning storm. ■ Never install a telephone jack in wet locations unless the jack is specifically designed for wet locations.
INSTALLING HARDWARE Installing Hardware Changing Mounting Brackets To use the low profile bracket, remove the standard bracket and replace it with the low profile bracket. Warning: Before handling the device, discharge any static in your body by touching a piece of grounded metal such as the computer chassis.
INSTALLING HARDWARE 2. Remove the two screws holding the standard bracket to the device. 12 MultiModem ® ISI ISI9234HPCIE Server Card User Guide.
INSTALLING HARDWARE 3. Mount the low profile bracket using the screws you removed in Step 1. Installing Hardware Note: Install the hardware, before installing drivers. Warning: Before handling the device, discharge any static in your body by touching a piece of grounded metal such as the computer chassis.
INSTALLING HARDWARE Attention: Perform the procedure described in this section only at an ESD workstation using an antistatic wrist strap. If such a station is not available, you can provide some ESD protection by wearing an antistatic wrist strap and attaching it to a metal ground screw (lug).
INSTALLING HARDWARE Cable Diagrams The ISI9234HPCIE uses a single fan-out cable to connect the four modems to four phone lines. The cable has an RJ- 45 connector on one end and four RJ-11 connectors on the other end. Use the RJ-11 connectors to connect to phone lines.
INSTALLING ON WINDOWS Installing on Windows The ISI9234HPCIE supports both 32-bit and 64-bit versions of the following Windows operating systems: ■ Windows Server 2003, 2008, and 2012 ■ Windows 7, 8, Vista, and XP For Linux support, refer to Installing on Linux.
INSTALLING ON WINDOWS To get the Communications port numbers to match COM ports: 1. In the Device Manager, go to Modems . 2. Right-click MultiTech Systems MT9234SMI #4 and select Uninstall . 3. On the Confirm Device Uninstall tab, check Delete the driver software for this device.
INSTALLING ON LINUX Installing on Linux Installing on Linux Kernel 3.5 and Higher Note: The steps below were tested with Ubuntu 12.04 with Linux kernel 3.5.0 and may or may not work for other 3.x.x versions. After installing the ISI9234HPCIE in a PCIe slot: 1.
INSTALLING ON LINUX 11. Run the command depmod . 12. Reboot Linux. Linux device drivers and device should now be installed and activated. To verify that the modules loaded, send the command lsmod Mult.
CONFIGURING MODEMS FOR YOUR COUNTRY Configuring Modems for Your Country Different countries have different regulations for modem operation. Before using your modems, you must configure them for the country in which you are using them. For Windows computers, use the Global Wizard to set the country.
CONFIGURING MODEMS FOR YOUR COUNTRY Using AT Commands to Set Country If not using Windows, use AT commands to configure the modem. A complete list of country and region codes is available on the Multi-Tech site at www.multitech.com/global/configuration.
REGULATORY INFORMATION Regulatory Information 47 CFR Part 68 Telecom 1. This equipment complies with Part 68 of the 47 CFR rules and the requirements adopted by the ACTA.
REGULATORY INFORMATION Trade Name: SocketModem Model Number: MT9234SMI Registration Number: US:AU7MM01BMT9234SMI Ringer Equivalence: 0.1B Modular Jack (USOC): RJ11C or RJ11W (single line) Service Center in USA: Multi-Tech Systems, Inc.
ENVIRONMENTAL INFORMATION Environmental Information Waste Electrical and Electronic Equipment Statement WEEE Directive The WEEE Directive places an obligation on EU-based manufacturers, distributors, retailers, and importers to take- back electronics products at the end of their useful life.
ENVIRONMENTAL INFORMATION REACH Statement Registration of Substances After careful review of the legislation and specifically the definition of an “article” as defined in EC Regulation 1907/2006, Title II, Chapter 1, Article 7.1(a)(b), it is our current view Multi-Tech Systems, Inc.
ENVIRONMENTAL INFORMATION Restriction of the Use of Hazardous Substances (RoHS) Multi-Tech Systems, Inc Certificate of Compliance 2011/65/EU Multi-Tech Systems confirms that its embedded products comp.
ENVIRONMENTAL INFORMATION Information on HS/TS Substances According to Chinese Standards In accordance with China's Administrative Measures on the Control of Pollution Caused by Electronic Inform.
ENVIRONMENTAL INFORMATION Information on HS/TS Substances According to Chinese Standards (in Chinese) 依 依照 照中 中 国 国标 标准 准 的 的有 有毒 毒 有 有害 害物 物 质 质信.
Ein wichtiger Punkt beim Kauf des Geräts Multitech ISI9234HPCIE (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Multitech ISI9234HPCIE noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Multitech ISI9234HPCIE - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Multitech ISI9234HPCIE reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Multitech ISI9234HPCIE erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Multitech ISI9234HPCIE besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Multitech ISI9234HPCIE verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Multitech ISI9234HPCIE. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Multitech ISI9234HPCIE gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.