Benutzeranleitung / Produktwartung PKA-AFAL des Produzenten Mitsubishi Electronics
Zur Seite of 14
Air -Conditioner s PKA-A·F A PKA-A·F AL English INST ALLA TION MANU AL For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit.
2 s Before installing the unit, make sure you read all the “Safety precau- tions”. s Please report to your supply authority or obtain their consent bef ore connecting this equipment to the power suppl y system. W arning: Describes precautions that must be observed to prevent danger of injury or death to the user .
3 2. Installation location 3. Installing the indoor unit Fig. 2-1 3.1. Check the indoor unit accessories (Fig. 3-1) The indoor unit should be supplied with the follo wing accessor ies.
4 3. Installing the indoor unit 3) Installing the wall mounting fixture s Since the indoor unit weighs near 30 kg, 66 lbs, selection of the mounting location requires thorough consideration. If the wall does not seem to be strong enough, reinforce it with boards or beams bef ore installation.
5 3. Installing the indoor unit 4. Installing the refrigerant piping 3.4. Mounting the indoor unit (Fig. 3-11) 1 Make sure to hang the metal catches of the indoor unit o ver the hooks of the wall mounting fixture. 2 When the piping has been completed, use the securing screws to fix the indoor unit on the wall mounting fixture .
6 4.4. Insulating pipes (Fig. 4-5) Refer to the Fig. 4-5 for insulating. Liquid pipe Gas pipe Insulation material 3 Band (large) 4 Band (small) 4 Band (small) 4 Ta p e Thermal insulating material for refrigerant piping Thermal insulating material for liquid pipe Liquid pipe 13/16 inch O.
I nd oo r u ni t m o de l Minim u m c ir cu i t am p a c i ty Ma x im u m ra t ing of o ver cu rren t p r ot e ct ive devi c e I nd oo r u ni t-Out d oo r u ni t *1 I nd oo r u ni t ear th Rem ot e co.
8 6. Electrical work S1 S2 S3 L1 L2 GR BLUE BLUE YELLOW YELLOW CND CND ORANGE CND ORANGE S1 S2 S3 L1 L2 GR YELLOW BLUE BLUE YELLOW CND 6.1.2. Separate indoor unit/outdoor unit power supplies (A-contr ol application) The follo wing connection patterns are availab le.
11 A P air No. of wireless remote controller Indoor PC board 0 F actory setting 1 Cut J41 2 Cut J42 3–9 Cut J41, J42 4) Assigning a remote controller to each unit (Fig. 6-7) Each unit can be operated only b y the assigned remote controller . Make sure each pair of an indoor unit PC board and a remote controller is assigned to the same pair No .
12 6. Electrical w ork Function table Select unit number 00 Mode P ower f ailure automatic recov er y Indoor temperature detecting LOSSNA Y connectivity P ower v oltage Auto mode (only f or PUHZ) Sett.
13 7.2.3. Using SW4 in outdoor unit Refer to the outdoor unit installation man ual. 7.3. Self-chec k 7.3.1. Wired remote controller (Fig. 7-3) 1 T urn on the power . 2 Press the [CHECK] button twice . 3 Set refrigerant address with [TEMP] button if system control is used.
14 • If the unit cannot be operated properly after the abov e test run has been performed, refer to the f ollowing table to remo ve th e cause. Symptom Cause Wired remote controller LED 1, 2 (PCB in.
15 Maintenance mode operation procedures (1) Press the TEST button f or three seconds to activate the maintenance mode . (2) Press the TEMP . buttons to set the refrigerant address.
Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment.
Ein wichtiger Punkt beim Kauf des Geräts Mitsubishi Electronics PKA-AFAL (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Mitsubishi Electronics PKA-AFAL noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Mitsubishi Electronics PKA-AFAL - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Mitsubishi Electronics PKA-AFAL reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Mitsubishi Electronics PKA-AFAL erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Mitsubishi Electronics PKA-AFAL besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Mitsubishi Electronics PKA-AFAL verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Mitsubishi Electronics PKA-AFAL. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Mitsubishi Electronics PKA-AFAL gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.