PEFY -1 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E 1. SPECIFICA TIONS .............................................................................
PEFY -2 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E CEILING-CONCEALED (LOW/MEDIUM/HIGH-ST A TIC PRESSURE) PEFY -P-NMSU- E (Low Profile) PEFY -P-NMHU-E PEFY -P-NMSU- E For PEFY -P-NMHU-E, can be done from the side all the maintenance work inspection hole.
PEFY -3 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 1. SPECIFICA TIONS Model PEFY -P06NMSU-E PEFY -P08NMSU-E PEFY -P12NMSU-E PEFY-P15NMSU-E Power source 1-phase 208/230v 60Hz Cooling capacity *1 (Nominal) Btu / h 6,000 8,000 12,000 15,000 kW 1.
PEFY -4 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E Model PEFY -P18NMSU-E PEFY-P24NMSU-E Power source 1-phase 208/230V 60Hz Cooling capacity *1 (Nominal) Btu / h 18,000 24,000 kW 5.3 7.0 Power input kW 0.
PEFY -5 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E CN24REL AY -KIT -CM3 CN24REL AY -KIT -CM3 CN24REL AY -KIT-CM3 CN24REL AY -KIT-CM3 PEFY -P06NMAU-E PEFY-P08NMAU-E PEFY -P12NMAU-E PEFY-P15NMAU-E 0.
PEFY -6 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 1. SPECIFICA TIONS PEFY -P18NMAU-E PEFY-P24NMAU-E PEFY-P27NMAU-E PEFY -P30NMAU-E 0.14-(0.20*)-0.28-0.40-0.60 35-(50*)-70-100-150 0.14-(0.20*)-0.
PEFY -7 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E PEFY -P36NMAU-E PEFY-P48NMAU-E PEFY -P54NMAU-E 0.14-(0.20*)-0.28-0.40-0.60 35-(50*)-70-100-150 35-(50*)-70-100-150 35-(50*)-70-100-150 DC brushless motor DC brushless motor DC brushless motor 0.
PEFY -8 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E Mode lP EFY-P15NMHU- EP EFY-P18NMHU-E PEFY-P24NMHU-E PEFY-P27NMHU-E Power source 1-phase 208/230 V 60Hz Cooling capaci ty B TU / h 15,000 18,000 24,000 27,000 (Nominal ) kW 4.
PEFY -9 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 1. SPECIFICA TIONS Note: *1 Nominal cooling conditions *2 Nominal heating conditions Unit converter Indoor: 80degF D.B. / 67degF W .B. (26.7degC D.
PEFY -10 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 1. SPECIFICA TIONS Note: *1 Nominal cooling conditions *2 Nominal heating conditions Unit converter Indoor: 80degF D.B. / 67degF W .B. (26.7degC D.
PEFY -1 1 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 1. SPECIFICA TIONS S Electrical characteristics of Indoor unit Symbols: MCA : Min.
PEFY -12 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E mm(in.) (35-7/16) (27-9/16) (19-1 1/16) (41-3/4) (33-7/8) (26) (47-1/4) (39-3/8) (31-1/2).
PEFY -13 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 2. EXTERNAL DIMENSIONS 5 2. EXTERNAL DIMENSIONS DATA U6 INDOOR UNITS 2. EXTERNAL DIMENSIONS 3-Ø2.9(1/8) mounting hole Air filter Drain pipe(O.
PEFY -14 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 2. EXTERNAL DIMENSIONS 2. EXTERNAL DIMENSIONS DATA U6 INDOOR UNITS 6 780 10 4 10 300 150 .
PEFY -15 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 2. EXTERNAL DIMENSIONS DATA U3 PEFY-P-NMLU-E/PEFY-P-NMHU-E IU - A - 8 mm(in.) 4-14X30(9/16X1-3/16) Slot Keep duct-work length 850mm(33-15/32 in.
PEFY -16 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E IU - A - 9 2. EXTERNAL DIMENSIONS DATA U3 PEFY-P-NMLU-E/PEFY-P-NMHU-E 4-14X30(9/16X3/16) Slot Air inlet Air outlet Keep duct-work length 850mm(33-15/32 in.
PEFY -17 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 3. CENTER OF GRA VITY Model name PEFY -P06NMSU-E PEFY -P08NMSU-E PEFY -P12NMSU-E PEFY -P1.
PEFY -18 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 3. CENTER OF GRA VITY 9 3. CENTER OF GRAVITY DATA U6 INDOOR UNITS 3.
PEFY -19 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 4. ELECTRICAL WIRING DIAGRAMS 8 7 6 5 4 3 2 1 4 3 2 1 1~ M M 4 23 1 M 13 24 12 1 4 5 6 7 6 5 3 1 4 3 2 1 13 5 1 2 13 24 8 13 2 456 7 1 3 PARTS LOCATION CONTROL BOX I.
PEFY -20 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 4. ELECTRICAL WIRING DIAGRAMS External Heater Note: If using gravity drain, unplug pump connecto r.
PEFY -21 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 4. ELECTRICAL WIRING DIAGRAMS S(SHIELD) G PA RTS LOCA TION (White) (Y ellow )( Green) (Re.
PEFY -22 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 4. ELECTRICAL WIRING DIAGRAMS S(SHIELD) PA RTS LOCA TION LEV adapter board (Green) (Red ).
PEFY -23 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5. SOUND PRESSURE LEVELS Aux.duct 3-1/4ft. (1m) 4-7/8ft. (1.5m) Measurement location 6-1/2ft. (2.0m) 5-1. Sound Pressure Levels Measured in an anechoic room.
PEFY -24 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5-2. NC Curves 10.0 15.0 20.0 25.0 30.0 35.
PEFY -25 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5. SOUND PRESSURE LEVELS PEFY - 15 5. SOUND LEVELS DATA U4 PEFY-P-NMSU-E/PEFY-P-NMHU-E PEFY 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.
PEFY -26 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5. SOUND PRESSURE LEVELS 5. SOUND LEVELS DATA U6 INDOOR UNITS 12 5-2. NC curves 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.
PEFY -27 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 13 5. SOUND LEVELS DATA U6 INDOOR UNITS 10.
PEFY -28 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5. SOUND LEVELS DATA U6 INDOOR UNITS 14 10.
PEFY -29 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 15 5. SOUND LEVELS DATA U6 INDOOR UNITS 10.
PEFY -30 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5. SOUND PRESSURE LEVELS 5. SOUND LEVELS DATA U4 PEFY-P-NMSU-E/PEFY-P-NMHU-E PEFY - 16 PEFY 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.
PEFY -31 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5. SOUND PRESSURE LEVELS PEFY - 17 5. SOUND LEVELS DATA U4 PEFY-P-NMSU-E/PEFY-P-NMHU-E PEFY 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.
PEFY -32 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5. SOUND LEVELS DATA U4 PEFY-P-NMSU-E/PEFY-P-NMHU-E PEFY - 18 PEFY 10.
PEFY -33 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 5. SOUND PRESSURE LEVELS PEFY - 19 5. SOUND LEVELS DAT A U4 PEFY-P-NMSU-E/PEFY-P-NMHU-E PEFY 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.
PEFY -34 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES PEFY -P08NMSU-E External static pressure : 5Pa,0.020[in.WG] Power source : 208,230V / 60Hz PEFY -P06NMSU-E External static pressure : 35Pa,0.
PEFY -35 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E Static pressure (Pa)[in.WG] PEFY -P12NMSU-E External static pressure : 35Pa,0.141[in.WG] Power source : 208,230V / 60Hz PEFY -P12NMSU-E External static pressure : 5Pa,0.
PEFY -36 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E Static pressure (Pa)[in.WG] Static pressure (Pa)[in.
PEFY -37 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E PEFY -P06,08,12,15,18,24,27NMSU-E Air filter static pressure cuves Air filter Static pressure (Pa) [in. WG] Airflow rate (m 3 /min) [cfm] 15 10 5 0 [0.
PEFY -38 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES Initial FIlter Pressure Drop Curves with Optional 1 " .
PEFY -39 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES Initial FIlter Pressure Drop Curves with Optional 1 " .
PEFY -40 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS 16 6. FAN CHARACTERISTICS CURVES PEFY -P06,08NMAU-E External static pressure : 35Pa [0.
PEFY -41 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 17 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS PEFY -P12NMAU-E External static pressure : 35Pa [0.141in.WG] Power source : 208-230V Static pressure (Pa) [in.
PEFY -42 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS 18 PEFY -P15NMAU-E External static pressure : 35Pa [0.141in.WG] Power source : 208-230V Static pressure (Pa) [in.
PEFY -43 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 19 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS PEFY -P18NMAU-E External static pressure : 35Pa [0.141in.WG] Power source : 208-230V Static pressure (Pa) [in.
PEFY -44 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS 20 PEFY -P24NMAU-E External static pressure : 35Pa [0.141in.WG] Power source : 208-230V Static pressure (Pa) [in.
PEFY -45 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 21 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS PEFY -P27,30NMAU-E External static pressure : 35Pa [0.141in.WG] Power source : 208-230V Static pressure (Pa) [in.
PEFY -46 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS 22 PEFY -P36NMAU-E External static pressure : 35Pa [0.141in.WG] Power source : 208-230V Static pressure (Pa) [in.
PEFY -47 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 23 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS PEFY -P48NMAU-E External static pressure : 35Pa [0.141in.WG] Power source : 208-230V Static pressure (Pa) [in.
PEFY -48 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS 24 PEFY -P54NMAU-E External static pressure : 35Pa [0.141in.WG] Power source : 208-230V Static pressure (Pa) [in.
PEFY -49 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 25 6. FAN CHARACTERISTICS CURVES DATA U6 INDOOR UNITS PEFY -P06,08,12,15,18,24,27,30,36,48,54NMAU-E Air filter static pressure cuves Air filter Static pressure (Pa) [in.
PEFY -50 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES Initial FIlter Pressure Drop Curves with Optional 2 " .
PEFY -51 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES PEFY-P18-NMAU w ith Filt er Box FBM2-2 0.08 0.09 0.10 0.11 0.12 0.13 0.14 0.15 424 449 474 499 52 5 550 575 600 A irflow rate (cfm) Stati c Pressure (in.
PEFY -52 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E PEFY-P36-NMAU w ith Fil te r Box FBM 2-4 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 812 862 913 963 1014 10 64 1115 1 165 A i r f low rate (cfm) Stat ic Pressure (in.
PEFY -53 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES PEFY -P15,18NMHU-E External static pressure : 100,150,200Pa,0.401,0.602,0.803[in.WG] Power source : 230V / 60Hz Suction : Back inlet PEFY -P15,18NMHU-E External static pressure : 50,160Pa,0.
PEFY -54 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES PEFY -P30NMHU-E External static pressure : 100,150,200Pa,0.401,0.602,0.803[in.WG] Power source : 230V Suction : Back inlet PEFY -P30NMHU-E External static pressure : 50,160Pa,0.
PEFY -55 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 6. F AN CHARACTERISTIC CURVES PEFY -P72NMHU-E External static pressure : 100,200Pa,0.401,0.803[in.WG] Power source : 230V / 60Hz Suction : Back inlet PEFY -P72NMHU-E External static pressure : 70,160Pa,0.
PEFY -56 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 7. OA INTAKE-STATIC PRESSURE CURVES DATA U6 INDOOR UNITS 26 7. OA INTAKE-STATIC PRESSURE CURVES P06,08 PEFY -P06,08,12,15,18,24,27,30,36,48,54NMAU-E OA Intake-static pressure curves Static pressure (Pa) [in.
PEFY -57 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 8. OPTIONAL P ARTS Long-life filter P AC-KE-LAF Filter box P AC-KE-TB-F PEFY -P-NMHU-E Dr.
PEFY -58 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E 8-3. FBM2-Series MERV 13 Filter Boxes for PEFY -P-NMAU-E Part No. Used on CITY MUL TI Models Filters Included S hip Weight (lbs.) Net Weight (lbs.
PEFY -59 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E Life span: 2,500 hr *. The actual dust situation affects the filter life span, which should be considered at the applying site.
PEFY -60 PEFY -P-NMSU-E/PEFY -P-NMAU-E/PEFY -P-NMHU-E (June 2010) PEF Y-P-NMSU-E PEF Y-P-NMAU-E PEF Y-P-NMHU-E External heater adaptor CN24RELA Y -KI T- CM3 is a set of special wiring parts for controlling the electric heater* with the air conditioner system.
Ein wichtiger Punkt beim Kauf des Geräts Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Mitsubishi Electronics PEFY-P-NMSU-E/PEFY-P-NMAU-E/PEFY-P-NMHU-E gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.