Mitsubishi Electric Air Co nditioner Network System PI controller PAC-YG60MCA Installation/Instruction Manual Before using the PI controller, plea se read this installa tion/instruction manu al carefully to ensure proper operation. Keep this installation/instruction manual for futu re reference.
1 • Before using the device, thorou ghly read the follo wing safety precautions and use as dir ected. • Hazards and levels o f danger tha t can occur du e to in correct handling are classified by the following symbols. • After reading this manual, keep this ma nual for future reference.
2 • Confirm that the box contains the following parts. * In addition to the parts mentioned above, other par ts need to be procured locally in order to operate this device. Furthermore , oth er Mitsubishi optional parts may be required depending on how the device is to be used.
3 5 Example of System Configuration Note: • For the shield ground of the M-NET centralized control line for central control, use single-po int grounding at the power unit for the transmission line.
4 6-1. Parts to be Procured Locally Prepare the following parts to install th is device. [Parts to be Purchased Separately] [Recommended Pulse Specifications] Prepare a measuring instrumen t that measures the type of pulse sign als indicated in table below.
5 6-2. Installation Procedure The PI controller PAC-YG60MCA does not ha ve a waterpro of structure. Be sure to install the PI controller inside a control panel tha t is located indoors. Prepare a control panel capable of storing this device such as the one shown in the figure.
6 (3) Refer to "7 Wiring Method " and connect the wires for the po wer line, M-NET transmission line, and input/outpu t signal lines. 7-1. Names of Parts PAC - SC50KUA M-NET N FG L -V +V Diagram Image (Installed within a Contro l Panel) * The wiring in the diagram has bee n simplified.
7 7-2. Connecting the Power Line and M-NET Transmission Line CN16 V+/V -/FG CN17 A/B/S S FG M- NET S / B / A (M1) (M2) U U R Tightening to rque for term inal screws: 1 N·m Connect the device to a pow.
8 7-3. Connecting the Signal Lines • Separate ly procure items such as te rminal blocks and cables locally. • The maximum wire length is 10 0 m. However, since th e use of long wires makes th e device susceptible to noise, using wires shorter than 10 m is recommended.
9 After completing the p rocedures described in "6 Installation Method" and "7 Wiring Method", set the initial settings in accordance with the procedure descr ibed below. (1) M-NET address settin gs (2) Use the dip switches to select functions.
10 Set the dip switches for fu nction selection according to the system to be used. At the time of shipment, all dip switches are set to OFF and the M-NET ad dress is set to 01. *1: When using a system controller (G(B)-50A or T G-2000A), select the "SC setting" and set the pulse we ight value settings from a system controller.
11 The LEDs of this device indicate the pulse in put status and error status of this device. 10-1.Display Content List *1: If a communication error occurs, switch to "Communication Err o r Status Display".
12 Use the following pr ocedure to co nfirm operation of the system. (1) Configure the settings of this devi ce and the system controllers while refe rring to "8 Initial Setting Procedure". (2) Perform an operation from a system co ntroller and confirm whether a connected device can be operat ed normally.
.
.
WT04973X01 This product is designed and int ended fo r use in the residential, commercial and light-i ndustr ial environment. This product at hand is based on the following EU regulations: • Low Vol.
Ein wichtiger Punkt beim Kauf des Geräts Mitsubishi Electronics PAC-YG60MCA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Mitsubishi Electronics PAC-YG60MCA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Mitsubishi Electronics PAC-YG60MCA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Mitsubishi Electronics PAC-YG60MCA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Mitsubishi Electronics PAC-YG60MCA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Mitsubishi Electronics PAC-YG60MCA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Mitsubishi Electronics PAC-YG60MCA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Mitsubishi Electronics PAC-YG60MCA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Mitsubishi Electronics PAC-YG60MCA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.