Benutzeranleitung / Produktwartung MIL-S1600 des Produzenten Milan Technology
Zur Seite of 16
MIL-S2400 & MIL-S1600 Fast Ethernet Switch 16 or 24 10/100 Mbps auto-sensing ports with optional 1 port 100Mbps Fiber Module User Guide With Optional Fiber 100BASE-TX Extension 100Base-FX with Mod.
Regulatory Approval - FCC Class A - UL 1950 - CSA C22.2 No. 950 - EN60950 - CE - EN55022 Class A - EN55024 Canadian EMI Notice This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.
C ontents 1. Introduction …….…………….…………….……….………….…… 1 Features …………………………………………..…..…….… 2 Package Contents ………………………..…..……….……… 3 Ethernet Switching T echnology ………………….
Introduction Ethernet Switching Technology Ethernet Switching Technology dramatically increases the total bandwidth of a network, eliminates congestion problems inherent with ( CSMA/CD ) protocol, which greatly reduces unnecessary transmissions. Switch Technology has revolutionized networking.
Features n Conforms to IEEE 802.3, 802.3u, and 802.3x standard n 16/24x auto-sensing 10/100Mbps Ethernet RJ-45 ports n Automatic MDI/MDIX ports crossover for 10Base-T and 100Base-TX n One Extension Sl.
Hardware Description This Section mainly describes the hardware of the MIL-S2400 and MIL-S1600 Switches , and gives a physical and functional overview of each Switch. Front Panel The Front Panel of the MIL-S2400 and MIL-S1600 Switches consists of 16 or 24 10/100Base-TX RJ-45 ports ( Auto MDI/MDIX ) and slot for 100Base-FX Fiber Module.
LED Indicators The LED Indicators gives a real-time information of systematic operation status. The following table provides descriptions of LED status and their meaning. Figure 2-2. LED Indicators LED Status Description Green Power On Off Off Green The port is operating at the speed of 100Mbps.
Rear Panel The 3-pronged power plug, On/Off switch, and ventilation fan are located at the rear panel of the MIL- S2400 and MIL-S1600 Switches as shown in Figure 2-2. The Switch will work in the range 100-240V AC, 50-60Hz. Figure 2-3. The Rear Panel of MIL-S2400 and MIL-S1600 Switches Desktop Installation A.
Rack-mounted Installation The MIL-S2400 and MIL-S1600 switches includes a rack-mounted kit and can be mount in an EIA standard size, 19-inch Rack, enabling the switch to be placed in a wiring closet with other equipment. Perform the following steps to rack mount the switch: A.
Optional Fiber Modules This section introduces the optional 100Base-FX Modules which can be installed on the front panel of the MIL-S2400 and MIL-S1600 Switches. Each optional 100Base-FX Module has a one- port fiber connector. The 100Base-FX Modules are designed to extend the distance between switch and other devices.
MIL-S2416ST MIL-S2416MT MIL-S2416VF.
LED Indicators of 100base-FX The LED-Indicators provide a real-time information of systematic operation status. The following table provides descriptions of LED Indicators status and their meaning. Blinks This fiber port is transmitting data. Off No data is be transmitted.
Installing 100Base-FX Module The optional 100Base-FX Modules are designed to be inserted in the extension slot. Before installation, ensure that the power is disconnected. The module is NOT hot-swappable. Follow the steps below to install the optional 100Base-FX Module: 1.
Troubleshooting This section is intended to help you solve the most common problems on the MIL-S2400 and MIL- S1600 Switches. n Faulty or loose cables Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are snug.
Technical Specification Specifications Standard IEEE 802.3 10Base-T Ethernet, IEEE 802.3u 100Base-TX/FX Fast Ethernet Protocol CSMA/CD Max Forwarding Rate and Max Filtering Rate 14,880 pps per Etherne.
P/N: 90000372_A.
Ein wichtiger Punkt beim Kauf des Geräts Milan Technology MIL-S1600 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Milan Technology MIL-S1600 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Milan Technology MIL-S1600 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Milan Technology MIL-S1600 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Milan Technology MIL-S1600 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Milan Technology MIL-S1600 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Milan Technology MIL-S1600 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Milan Technology MIL-S1600. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Milan Technology MIL-S1600 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.