METROLOGIC INSTRUMENTS, INC. MS1690 Focus ® Series Area Imaging Bar Code Scanner Installation and User's Guide.
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any for m or by any means without prior written consent, except by reviewer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE OF C ONTENTS Introduction Product Over view ............................................................................................. 1 Scanner and A ccessori es ...........................................................................
iii T ABLE OF C ONTENTS Default Settings – Commu nication Para meters .................................................. 30 Configurati on Modes .......................................................................................... 34 Upgrading the Flash ROM Firmware .
1 I NTRODUCTION Product Overvie w Metrologic's MS1690 Focus ® series of high p erformance hand-held area i maging bar code scanners utilizes high-resoluti on CMOS imaging sensors for superior image quality. Omniplanar, In c.’s SwiftDecoder ® software, for reliable decodi ng of both 1D and 2D bar code symbologi es.
2 I NTRODUCTION Scanner and Accessories B ASI C K IT Part # Description MS1690 or MS1691 Area Imaging Bar Code Scanner or Area Imaging HD Bar Code Scann er 00-02544 MetroSelect ® Singl e-Line Configu.
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 53-53213x-N-3-FR USB Full Speed Cable, Locking Plus-Po wer™ Type A, coiled cord, long strain re lief, black with fer.
4 I NTRODUCTION Scanner Components Figure 1. Scanner Components Item Description 1 Yellow LED See Visual Indicators (on page 17) 2 White LED See Visual Indicators (on page 17) 3 Blue LED See Visual In.
5 I NTRODUCTION The PowerLink Cable Connecting Important: If the PowerLink cable is not fully ‘latched’ the unit can power intermittently. Figure 2.
6 I NTRODUCTION Labels Each scanner has a label loc ated on the underside of the hea d. This label provides the unit’s model number, date of manufacture, serial number, CE and caution information. The follo wing figur e gives an example of the lab el and its location.
7 I NSTALLING THE S CANNER TO THE H OST S YSTEM RS232 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages. 3. Connect the 9-pin D-type connector of the communication cable to the proper COM port of the host device.
8 I NSTALLING THE S CANNER TO TH E H OST S YSTEM Keyboard Wedge 1. Turn off the host device. 2. Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pi n socket on the scanner. There will be an audibl e click when the connector lock engag es. 3.
9 I NSTALLING THE S CANNER TO TH E H OST S YSTEM Stand Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the scanner. There will be an audible click when the connector lock engages.
10 I NSTALLING THE S CANNER TO TH E H OST S YSTEM RS485 S 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the scanner. There will be an audibl e click when the connector lock engages. 3. Connect the other end of the MVC cable to the host device.
11 I NSTALLING THE S CANNER TO TH E H OST S YSTEM Integrated USB: Full Speed (- 40 or - 106) Low Speed (- 38) 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the scanner. There will be an audibl e click when the connector lock engag es.
12 S TAND K ITS Stand Components, MLPN 46-00147 Figure 11. Stand Components Item Description Qty. a. Stand Base Qty. 1 b. Flexible Shaft Qty. 1 c. Flexible Shaft Cover Qty. 1 d. Scanner Cradle Qty. 1 e. ¼" – 20 x 3/8" Flat Head Phill ips, 100° Undercut Qty.
13 S TAND K ITS Hard Mounting the Stand (Optional) Metrologic provides two #8 wood scre ws for securing the stand base to the counter top. The following figure provides th e pilot hole dimensions for sec uring the stand base.
14 S TAND K ITS Assembling the Stand Figure 13. Assembling the Stand.
15 S CANNER O PERATION Two Default Modes of Op eration* Multi-Trigger, Out of Stand 1. The IR detects an object in the IR activation range and automatically turns on linear illumination. 2. Aim the scanner’s line of light over the bar code. 3. Pull the trigger to initiate scanning.
16 S CANNER O PERATION Audible Indicators When the MS1690 series scanner is in op eration, the scanner provides audible feedback. These sounds indicate the st atus of the scanner. Eight settings are available for the tone of the beep (norma l, 6 altern ate tones and no tone).
17 S CANNER O PERATION Visual Indicators The MS1690 series scanner has three L ED indicators (yellow, white and blue) locat ed on the top of the scanner. When the scanner is on, the flas hing or stationar y activity of the LEDs indicates the status of the current scan and the scanner.
18 S CANNER O PERATION Failure Modes Long Razzberry Tone – During Power Up Failed to initialize or configure the sc anner. If the scanner does not respond after reprogramming, return the scan ner for repair. Short Razzberry Tone – During Scanning An Invalid bar code has been scanne d when in configuratio n mode.
19 S CANNER O PERATION MS1690 Depth of Field by Mini mum Bar Code Element Width M INIMUM B AR C ODE E LEMENT W IDTH 1D PDF A B C D E F G mm .132 .19 .254 .
20 S CANNER O PERATION MS1691 Depth of Field by Mini mum Bar Code Element Width M INIMUM B AR C ODE E LEMENT W IDTH 1D Data Matrix A B C D E mm .102 .127 .
21 S CANNER O PERATION MS1690 IR Activation Range The MS1690 scanner has a built in object detection sens or that instantly turns on the scanner when an object is presented wi thin the scanner’s IR activation Area. Figure 18. MS1690 IR Activation Area Specifications are subjec t to change without notice .
22 S CANNER O PERATION MS1691 IR Activation Range The MS1691 scanner has a built in object detection sens or that instantly turns on the scanner when an object is presented wi thin the scanner’s IR activation Area. Figure 19. MS1691 IR Activation Area Specifications are subjec t to change without notice .
23 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Me tro or 1- 800-436-3876 to pres erve the limited warranty terms. All Interfaces MS1690 Series Troubleshooting Gui de Symptoms Possible Causes Solution No power is being supplied to the scanner.
24 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not beep when bar code is scanned. The beeper is disabled and no tone is selected. Enable the beeper and select a tone. The unit powers up, but does not scan and/or beep.
25 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The bar code may have been printed incorrectly. Check if it is a check digit/character/ or border problem. The scanner is not configured correctly for this type of bar code. Check if check digits are set properly.
26 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit is transmitting each character twi ce. The configuration is not set correctly. Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.
27 D ESIGN S PECIFICATIONS MS1690 S ERIES D ESIGN S PECIFICATIONS O PER AT IO N AL Light Source: LED 645 nm Pulse Duration: 10 µs to 8000 µs Maximum Output: 0.76 mW peak MS1690 0 mm – 330 mm (0" – 13") Depth of Scan Field: MS1691 25 mm – 155 mm (1" – 6.
28 D ESIGN S PECIFICATIONS MS1690 S ERIES D ESIGN S PECIFICATIONS M ECHA N ICAL Height: 183 mm (7.2") Handle 30 mm (1.2") Width: Head 79 mm (3.1") Depth: 111 mm (4.9") Weight: 225 g (8.0 oz) Termination: 10 pin modular RJ45 Cable: Standard 2.
29 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S .
30 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S Many functions of the scanner can be “confi g ured” – that is, enabled or disabled. The scanner is shipped from the factor y c onfigured to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages.
31 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 RS485 S KBW USB Maxicode 9 9 9 9 Aztec 9 9 9 9 Postals 9 9 9 9 Mod 43 Check on Code 39 9 9 9 9 MSI-Plessy 10/10 Check Digi.
32 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 RS485 S KBW USB Transmit lead zero on UPC-E 9 9 9 9 Transmit UPC-A number system * 9 9 9 9 Transmit UPC-A Manufacturer ID#.
33 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 RS485 S KBW USB XON/XOFF Handshaking 9 ACK/NAK 9 Two Digit Supplements 9 9 9 9 Five Digit Supplements 9 9 9 9 Bookland 9 9.
34 C ONFIGURATION M ODES The MS1690 series has three modes of configuration. • Bar Codes The MS1690 series can be configur ed by scanning the bar codes include d in the Metrologic Single-Line Co nfiguration Guide ( MLPN 00-02544). This manual can be do wnloaded for FREE from Metrologic’s website (www.
35 U PGRADING THE F LASH ROM F IRMWARE The MS1690 Focus series is part of Metrologic's lin e of scanners with flash upgradeable firm ware. The upgrade proces s requires a new firmware file supplied to the customer by a customer service representati ve and Metrologic's MetroSet 2 software .
36 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1690-14 or MS1691-14, RS232 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 Reserved 8 Reserved 9 +5VDC The MS1690 series scanner interfaces terminate to a 10-pin, RJ45 Female Socket.
37 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1690-38, Low Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 USB D+ 7 V USB 8.
38 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000-3-FR Coiled Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive .
39 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge Po werLink Cable 53-53002-3 Coiled Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Grou.
40 L IMITED W ARRANTY The MS1690 Focus ® serie s scanners are manufactured by Metrologic at its Suzhou , China .The MS1690 series scanners hav e a five (5) year limited warranty from the date of manufacture.
41 R EGULATORY C OMPLIAN CE Safety ITE Equipment IEC 60950-1, EN 60950-1 LED Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adj ustments or performan ce of procedures oth er than those specified he rein may result in h azardous radi ation exposur e.
42 R EGULATORY C OMPLIAN CE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity per forman ce is not guar anteed for scanner cables grea ter than 3 meters i n length when f ully extended.
43 R EGULATORY C OMPLIAN CE EMC Changes or modifications not expressly approved by the part y responsible for compliance could void the user’s authority to operate the equipment.
44 P ATENTS For patent information, please refer to www.honeywellaidc.com/patents ..
45 I NDEX A AC ................................. 2, 7–11, 28 Accessori es ................................... 2 Adapter .................................... 2, 39 Apertu re......................................... 4 Audible Indica tor ..............
46 I NDEX Light Lev els ................................. 28 Light S ource ................................ 27 M Maintenanc e .................................. 6 MetroSelect ..................... 16, 29, 34 MetroSet 2 ................................
47.
N OTES.
N OTES.
N OTES.
.
July 2008 00 - 02098 G.
Ein wichtiger Punkt beim Kauf des Geräts Metrologic Instruments MS1690 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Metrologic Instruments MS1690 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Metrologic Instruments MS1690 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Metrologic Instruments MS1690 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Metrologic Instruments MS1690 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Metrologic Instruments MS1690 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Metrologic Instruments MS1690 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Metrologic Instruments MS1690. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Metrologic Instruments MS1690 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.