PULSAR C CCD Hand-Held Scanner User Manual Metrologic Instruments GmbH Dornier S trasse 2 82178 Puchheim Germany T el +49 89 890190 Fax +49 89 89019200 www .
Table of Contents 1. Introduc tion .................................................................................. 1 2. General Featur es ......................................................................... 2 2.1 Buzze r ......................
1 1. Introduction This manual contains all the info rmation needed to operate and configure the Pulsar C Barcode Scanner. It is divi ded into two parts. The first part of this manual describes the operation and programmable features of the scanner. The second part of this manual contains the setup barcodes used to configure the scanner.
3 period ( Scanner Time-Out Duration ) is expired. Unlike the Auto Off mode, the scanner will continue to scan and the scanning period is re-counted each time there is a successful read. • Alternate Mode: The scanner will start scanning once the switch is triggered.
5 3. Output Interface The Pulsar C is a single interface CCD scanner. It can be ordered as a keyboard wedge scanner, and a RS-232 scanner. The output interface must be specified at time of order. 3.1 Keyboard Wedge Interface 3.1.1 Keyboard Type The keyboard wedge interface is enabled by configuring/selecting keyboard type.
7 3.2 RS232 Interface The user can select the desired, fl ow control, baud rate, parity, and data bits to be used in this output interface. 3.2.1 Baud Rate / Parity / Data Bits The supported baud rate, parity, and data bit are listed below.
9 kind of undesired reading, the Code Length settings can help to insure that the correct code is read by qualifying the allowable code length. Code length parameters can be configured in two ways: Fixed Code Length or Max / Min code length . If the fixed code length is selected, up to 2 fixed lengt hs can be specified.
11 and Max/Min code length . If the fixed code length is selected, up to 2 fixed lengths can be specified. And if max / min code length is selected, the max length and the mi n length must be specified, and the scanner will only accept those codes with lengths fall between max / min length specified.
13 5.3 Code ID Up to two characters of Code ID c an be configured for each symbology. To minimize the Code ID configuration efforts, the scanner provides five predefined Code ID Sets that user can se lect from. User can first select one of the Code ID Sets and then make desired modifications.
15 • Code Type : This parameter specifie s the code type of the data eligible for data editing. Multiple code types can be specified for this parameter. • Data Length : This parameter specifies the length (character count) of the data eligible for data editing.
17 Example 2: Extract the date code, item number, and quantity information from barcodes. Data is encoded in t he barcode like this: From the first character to the 6th character is the date code. From the 7th character is the item number, its length is not fixed but is delimited by a ‘-’ character.
19 For these kinds of parameters, the l abel of the parameter to be configured must be read first. Then the labels comprising the numeric value or character string are read. Finally, t he “Validate” label must be read to complete the setting. The scanner will respond with two beeps when the “Validate” label is read.
21 • Add Control (R) : The right Control key will be sent together with the character programmed. • Add Alternate (R) : The right Alternate key will be sent together with the character programmed.
Ein wichtiger Punkt beim Kauf des Geräts Metrologic Instruments Hand-Held Scanner (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Metrologic Instruments Hand-Held Scanner noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Metrologic Instruments Hand-Held Scanner - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Metrologic Instruments Hand-Held Scanner reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Metrologic Instruments Hand-Held Scanner erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Metrologic Instruments Hand-Held Scanner besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Metrologic Instruments Hand-Held Scanner verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Metrologic Instruments Hand-Held Scanner. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Metrologic Instruments Hand-Held Scanner gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.