PCI-DAS1002 Multifunction Analog & Digit al I/O User's Guide Document Revision 4, July, 2007 © Copyright 2007 , Measurement Computing Co rporation.
Your new Measurement Computing produc t comes with a fantastic extra — Management committed to your satisfaction! Refer to www.mccdaq.com/execteam.html for the names, titles, an d contact inform ation of each ke y executive at Measurement Computing.
Trademark and Copyright Information TracerDAQ, Universal Library, Harsh E nvironment Warranty , Measurement Compu ting Corporation, an d the Measurement Computing logo are either trademarks or registered trademarks of M easurement C omputing Corporation.
Table of Contents Preface About this U ser's Gu ide .......................................................................................................................7 What you will learn from this user's guide .........................
PCI-DAS1002 User's Manual Miscella neous ................................................................................................................................................... 22 Power consumption ....................................
Preface About this User's Guide What you will learn from this user's guide This user's guide explain s how to inst all, confi gure, and us e the PCI-DAS 1002 so that y ou get the most out of its analog, digital, and timing I/O features.
Chapter 1 Introducing the PCI-DAS1002 Overview: PCI-DAS1002 features This manual explains how to install and u se the PCI-DAS1002. This board is a multifunctio n analog and digital I/O board desi gned f or the PCI bus. The PCI-DAS1002 p rovides either 16 single-ended or eight differential analog inputs.
PCI-DAS1002 User's Manual Introducing the PCI-DAS1002 PCI-DAS1002 block diagram PCI-DAS1002 functions are illustrated in the block diagram shown here.
Chapter 2 Installing the PCI-DAS1002 What is included with your PCI-DAS1002 As you unpack your board, make s ure each of the items shown bel ow is included: Hardware PCI-DAS1002 Additional documentation In addition to this hard ware user's guide, you shoul d also receive the Quick Start Guide (available in PDF at www.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Signal termination a nd conditioning accessories MCC provides signal terminatio n and conditioning products for use with the PCI-D AS1002. Refer to the " Field wiring and signal ter mination " section for a complete list of com patible accessory products.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Configuring the hardware All hardware configuration options on the PCI-DAS1002 are software c ontrolled.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Pinout – main I/O connector 8-channel differential mode Signal Name Pin Pin Signal Name GND 100 • • 50 GND N/C 99 • • 49 N/C N/C 98 • • 48 PC +5V N/C 97 • • 47 N/C N/C 96 • • 46 N/C A/D Int.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 16-channel single- ended mode Signal Name Pin Pin Signal Name GND 100 • • 50 GND N/C 99 • • 49 N/C N/C 98 • • 48 PC +5V N/C 97 • • 47 N/C N/C 96 • • 46 N/C A/D Int.
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Cables 1 50 2 49 51 100 52 99 100 50 51 1 Key Key The re d stri pe ide nt i fi es pi n # 1 The r ed stripe iden ti fies pi n # 51 Ca ble is la be led “Pins 5 1-100 ”. Cable i s lab eled “Pins 1- 50”.
Chapter 3 Programming and Developing Applications After following the installatio n instructions in Ch apter 2 , your board should now be inst alled and ready for use. Although the b oard is part of the larger D AS family , in general there may be no c orrespondence among registers for different boards.
Chapter 4 Calibrating the Board Introduction Calibrate the board u sing the Insta Cal utility after the board has fully warmed up. The reco mmended warm-up time is 15 m inutes. For best results, cal ibrate the boa rd immedi ately before m aking critical measurements.
Chapter 5 Specifications Typical for 25 °C unless other wise specified. Specifications in italic text are guarantee d by design. Analog input Table 1.
PCI-DAS1002 User's Manual Specifications Accuracy Accuracies are l isted for a 20 0 kHz sam pling rate, 10 0 sample avera ge, single cha nnel operation, a 15 mi nute warm-up, and operational temperatures with in ±2 ° C of internal calibration temperature.
PCI-DAS1002 User's Manual Specifications Analog output Table 6. Analog output specifications D/A converter type AD7847AR or equivalent Resolution 12 bits Number of channels 2 Configuration Voltage output, single-ended Output range ±10 V, ±5 V, 0 to 10 V, or 0 to 5 V.
PCI-DAS1002 User's Manual Specifications Counters Table 9. Counter specific ations Parameter Specification Counter type 82C54 Configuration Two 82C54 devices.
PCI-DAS1002 User's Manual Specifications Digital input/output Table 10. DIO specifications Digital type 82C55 Number of I/O 24 (FIRSTPORTA Bit 0 through FIRSTPORTC Bit 7) 2 banks of 8 and 2 banks of 4 or 3 banks of 8 or Configuration 2 banks of 8 with handshake Input high voltage 2.
PCI-DAS1002 User's Manual Specifications Connector and pin out Table 16. Main connector specificatio ns Connector type 100-pin high-density Robinson Nugent Compatible cable C100FF-x, unshielde d ribbon cab le.
PCI-DAS1002 User's Manual Specifications 16-channel single-ended mode pin out Pin Signal Name Pin Signal Name 1 LLGND 51 FIRSTPORTA Bit 0 2 CH0 HI 52 FIRSTPORTA Bit 1 3 CH8 HI 53 FIRSTPORTA Bit 2.
Declaration of Conformity Manufacturer: Measurement Computing C orporation Address: 10 Commerce Way Suite 1008 Norton, MA 02766 USA Category: Electrical equi pment for m easur ement, cont rol and laboratory use.
Measurement Computing Cor poration 10 Comme rce Wa y Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: info@mccdaq.com www.
Ein wichtiger Punkt beim Kauf des Geräts Measurement Specialties PCI-DAS1002 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Measurement Specialties PCI-DAS1002 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Measurement Specialties PCI-DAS1002 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Measurement Specialties PCI-DAS1002 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Measurement Specialties PCI-DAS1002 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Measurement Specialties PCI-DAS1002 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Measurement Specialties PCI-DAS1002 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Measurement Specialties PCI-DAS1002. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Measurement Specialties PCI-DAS1002 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.