Revision 1.8 Page i ® ® SSC200 Solid State Rate/Gyro Compass User’s Manual Revision 1.8 Copyright © 2012 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N.
SSC200 User’s Manual Page ii Revision 1.8 Revision History Revision Description 1.0 Original document. 1.1 Minor editorial changes. Corrected default rate for Rate of Turn PGN under Technical Specifications. 1.2 Minor editorial changes. Removed Warranty Card.
Revision 1.8 Page iii ® ® Table of Contents 1 General ....................................................................................................................... ....... 1 1.1 Introduc tion ...................................
SSC200 User’s Manual Page iv Revision 1.8 Table of Figures Figure 1 – Mounting the SSC200 to a Horizontal Surface ......................................................... 4 Figure 2 – Mounting the SSC200 to Vertical Surface ....................
Revision 1.8 Page 1 ® ® 1 General 1.1 Introduction Congratulations on your purc hase of the Maretron SSC200 Solid State Rate/Gyro Compass. Maretron has designed and built your compass to the highest standards for years of reliable, dependable, and accurate service.
SSC200 User’s Manual Page 2 Revision 1.8 6. Calibrate the SSC200 Compass for Installation-Offset (Section 3.2 ) 7. Use Default Variation Source or Select an Appropriate Variation Source (Section 4 ) 2 Installation 2.1 Unpacking the Box When unpacking the box containing the Maretron SSC200, you should find the following items.
Revision 1.8 Page 3 ® ® switched on and off, which makes compensation im practical. Therefore, you should try to mount the compass as far away as possible from these magnetic field sources (doubling the distance between the magnetic field source and the compass will reduce the field strength by a factor of approximately 8) .
SSC200 User’s Manual Figure 1 – Mounting the SSC200 to a Horizontal Surface 2.3.2 Mounting the SSC200 to a Vertical Surface Mounting the SSC200 compass to a vertical surface requires that the provided mounting brackets be fastened to the side of the SSC200 using the prov ided brass flat head screws.
® ® Figure 2 – Mounting the SSC200 to Vertical Surface 2.4 Connecting the SSC200 You have a choice of connec ting the SSC200 to a NMEA 2000 ® interface (Section 2.4.1 ), NMEA 0183 interface (Section 2.4.2 ), or connecting both interf aces simultaneously (Section 2.
SSC200 User’s Manual Page 6 Revision 1.8 NMEA 2000 / Power Connecto r NMEA 0183 Connector Figure 3 – NMEA 2000 ® / NMEA 0183 Interface Connector Locations 2.4.1 Connecting to NMEA 2000 ® Interface The Maretron SSC200 provides a connection to an NMEA 2000 ® interface through a five pin male connector ( Figure 4 ).
® ® Figure 5 - SSC200 with NMEA 2000 ® Connection Only 2.4.2 Connecting to NMEA 0183 Interface The Maretron SSC200 provides a connection to an NMEA 0183 interface through an eight pin male connector ( Figure 6 ).
SSC200 User’s Manual Figure 6 – NMEA 0183 Connector Face Views Connect the other end of the cable consisting of individual wires using recommended practices for installing NMEA 0183 produc ts.
® ® Figure 8 - SSC200 with NMEA 0183 Connection Only 2.4.2.2 Supported NMEA 0183 Baud Rates The SSC200 compass supports NMEA0183 co mmunication at both 4800 baud and 38400 baud.
SSC200 User’s Manual Page 10 Revision 1.8 This causes the new baud rate to be stored to non-volatile memory, so the compass will retain this baud rate when it is powered down. 2.4.3 Connecting Both NMEA 2000 ® and NMEA 0183 Interfaces The SSC200 can be simultaneously connected to both an NMEA 2000 ® network and an NMEA 0183 network.
Revision 1.8 Page 11 ® ® values in its permanent memory. Therefore, it is important to verify that the deviation calibration process completed successfully.
SSC200 User’s Manual Page 12 Revision 1.8 4. While continuing to turn the vessel as indicated in step 3, remove the power from the compass and reapply power (this in itiates deviation calibration). 5. Continue turning the vessel through four complete circles in less than 10 minutes from the time power was applied.
Revision 1.8 Page 13 ® ® 2. With the vessel laying flat in the water, adjust the pitch ang le of the SSC200 by adding small washers or spacers between the mounting bracket holes and mounting surface until the display reads zero for the pitch angle (skip this step if you are not interested in viewing the vessel’s pitch angle).
SSC200 User’s Manual Page 14 Revision 1.8 1. Transmit the Heading, Devi ation & Variation ( HDG) sentence includ ing the variation field as seen from the RMC or VTG sentence over the NMEA 0183 interface if HDG is enabled (see Appendix A for enabling or disabling NMEA 0183 sentences).
Revision 1.8 Page 15 ® ® 4.4 Variation Source Selection As shipped from the factory, the SSC200 automatically looks fo r variation from both the NMEA 0183 and NMEA 2000 ® interfaces.
SSC200 User’s Manual Page 16 Revision 1.8 5.1 Rate of Turn Damping Period Selection with Maretron Display You can program the SSC200 to us e a particular rate of turn damping period using a Maretron display product (e.g., DSM200). Refer to the display product user’s manual for details on programming the SSC200 to use a specific damping period.
Revision 1.8 Page 17 ® ® 7 Troubleshooting If you notice unexpected operation of the Ma retron SSC200, follow the troubleshooting procedures in this section to remedy simple problems.
SSC200 User’s Manual Page 18 Revision 1.8 8 Technical Specifications Specifications Parameter Value Comment Static Heading Accura cy <1° rms ±45° Pitch and Roll - 15°C to 35°C Heading Display Resolution 0.
Revision 1.8 Page 19 ® ® Electrical Parameter Value Comment Operating Voltage 9 to 16 Volts DC Voltag e Power Consumption <15 0mA Average Current Drain Load Equivalence Number (LEN) 3 NMEA 2000 ® Spec.
SSC200 User’s Manual 10 Installation Template Please check the dimensions before using the follo wing diagrams as templates for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Page 20 Revision 1.8 3 87” 1.
Revision 1.8 Page 21 ® ® 11 Maretron (2 Year) Limited Warranty Maretron warrants the SSC200 to be free from defects in materials and workm anship for two (2) y ears from the date of original purchase.
SSC200 User’s Manual Page 22 Revision 1.8 This page intentionally left blank.
Revision 1.8 Appendix A – NMEA 0183 Interfacing Page A1 ® ® Appendix A – NMEA 0183 Interfacing SSC200 NMEA 0183 Transmitted Sentences HDG – Heading, Deviation & Variation The SSC200 indicates heading 10 times a second. The deviation field always contains zero as the SSC200 reports it’s heading with the deviation included.
SSC200 User’s Manual Page A2 Appendix A – NMEA 0183 Interfacing Revision 1.8 D-I: Null TXT – Text Transmission The SSC200 transmits various status messages using the text transmission senten ce.
Revision 1.8 Appendix A – NMEA 0183 Interfacing Page A3 ® ® SSC200 NMEA 0183 Received Sentences Note on NMEA 0183 Checksums For ease of manual configuration of the SSC200 via the NMEA 0183 Interface, NMEA 0183 checksums are optional.
SSC200 User’s Manual Page A4 Appendix A – NMEA 0183 Interfacing Revision 1.8 $PMAREXE,SSC200,,5D,2,,,<CR><LF> This command causes the SSC200 to use variation data from the NMEA 0183 interface and ignore all other variation sources (i.e.
Revision 1.8 Appendix A – NMEA 0183 Interfacing Page A5 ® ® 5. To disable transmission of the HDT sentence: $PMARSETPX,SSC200,,02,0 6. To enable transmission of the HDT sentence at intervals of 100 ms: $PMARSETPX,SSC200,,02,100 7. To disable transmission of the ROT sentence: $PMARSETPX,SSC200,,03,0 8.
SSC200 User’s Manual Page A6 Appendix A – NMEA 0183 Interfacing Revision 1.8 5. Continue turning the vessel through at l east 3 circles until you see one of the following Maretron proprietary sentences: a.
Revision 1.8 Appendix B – NMEA 2000 ® Interfacing Page B1 ® ® Appendix B – NMEA 2000 ® Interfacing SSC200 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 127250 – Vessel Heading The SSC200 uses this PGN to indicate the vessel’s heading.
SSC200 User’s Manual Page B2 Appendix B – NMEA 2000 ® Interfacing Revision 1.8 2: Yaw – This field always contains a value of 0x7FFF (data not available). 3: Pitch – This field is used to report the vessel’s pitch. 4: Roll – This field is used to report the vessel’s roll.
Revision 1.8 Appendix B – NMEA 2000 ® Interfacing Page B3 ® ® Status Code Message Name Description 01 Deviation Calibration Started This me ssag e is transmitted at the beginning of the magnetic deviation calibration process.
SSC200 User’s Manual Page B4 Appendix B – NMEA 2000 ® Interfacing Revision 1.8 12: Maretron Command – set this field’s value to 0xF0, which will initiate a reset and start the calibration process. PGN 126208 – NMEA Command Group Function – Maretron Proprietary Installation Offset.
Revision 1.8 Appendix B – NMEA 2000 ® Interfacing Page B5 ® ® SSC200 NMEA 2000 ® Initiated Deviation Calibration NMEA 2000 ® initiated deviation calibra tion is accomplished by turning the vessel through at least 3 complete circles after the SSC200 receives a Maretron proprietary NMEA 2000 ® PGN.
SSC200 User’s Manual Page B6 Appendix B – NMEA 2000 ® Interfacing Revision 1.8 This page intentionally left blank.
Revision 1.8 Appendix C – Connecting to a PC Via NMEA 0183 Page C1 ® ® Appendix C – Connecting to a PC Via NMEA 0183 In order to perform configuration of the SSC200 ove r the NMEA 0183 interface, it is preferable that the connection be made by a RS-232 to RS-422 level converte r.
SSC200 User’s Manual Page C2 Appendix C – Connecting to a PC Via NMEA 0183 Revision 1.8 This page intentionally left blank.
Revision 1.8 Appendix D – Transmi tting True Heading Data Page D1 ® ® Appendix D – Configuring the SSC200 to Transmit True Heading Data The SSC200 is factory configured to transmit magnet ic hea ding data on the NMEA0183 interface. Some NMEA 0183 applications require true hea ding d ata.
SSC200 User’s Manual Page D2 Appendix D – Transmitting True Heading Data Revision 1.8 $PMAREXE,SSC200,,5D,0, <variation> ,, Where <variation> is the m agneti c variation in units of degrees and resolution in t enth of degrees – positive values represent easterly variation, and negative values re present westerly variation.
Revision 1.8 Appendix E – Transmitting the HDT Sentence Page E1 ® ® Appendix E - Configuring the SSC200 to Transmit the HDT Sentence for Satellite Antennas and Radars The SSC200 is factory configured to tr ansmit the HDG sentence 10 times pe r second.
SSC200 User’s Manual Page E2 Appendix E – Transmitting the HDT Sentence Revision 1.8 This page intentionally left blank.
Revision 1.8 Appendix F – Changing the NMEA 0183 Identifier Page F1 ® ® Appendix F – Changing the NMEA0183 Identifier Transmitted by the SSC200 The identifier for NMEA0183 sentences t ran smitted by the SSC200 is set by the factory to be “II”; however, some users may need to change this to other v alues.
Ein wichtiger Punkt beim Kauf des Geräts Maretron SSC200 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Maretron SSC200 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Maretron SSC200 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Maretron SSC200 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Maretron SSC200 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Maretron SSC200 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Maretron SSC200 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Maretron SSC200. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Maretron SSC200 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.