WARNING : Improper installation, adjustment , alt eration , service or maintenance can c ause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or t he gas supplier.
2 6 720 606 601 AquaSt ar 1 25FX LP and 1 25FX NG Specific ations W ater Connection 1 /2” Thread fitting N P T H x W x D 29 3/ 4” x 1 8 1 /4” x 8 3/4" V ent 4” Gas C onnection 1 /2” N PT thread Min. W ater Pressure 1 8 Psi Max. W ater Pressure 1 50 Psi Shipping W eight 50.
3 6 720 606 601 M I N I M U M I N S T ALLA TI ON C LE AR A N C E S F R OM C O M B USTI B LE AN D N ON C OM B U S TI B LE MA TE R IALS F OR AL C O VE OR C L O SET I N S T ALLA TI ON S FR ONT VI EW SI D.
4 6 720 606 601 G EN E RAL R U LES T O FOLL OW FOR SAFE O PE R A TI ON 1. Y ou should follow these instructions when you inst all your heater . In the United St ates: The installation must conform with local codes or , in the absence of local codes, the National Fuel Gas Code AN SI Z223.
5 6 720 606 601 COMBUSTION AIR REQUIREMENTS The AquaStar water heater holds cold water in its copper heat exchanger and brass water valve when not in use. Because of this, any cold air that comes in through the unit’s vent pipe is capable of freezing these components.
6 6 720 606 601 Fig . 3 - Inc andescent Part icle T ray Illust ration The incandescent particle tray (shipped loose in the carton with the water heater) must be attached at the bottom of the water heater front cover at the time of installation. Use the screws provided.
7 6 720 606 601 VENTING WARNING: Do not reduce the vent pipe size and do not common vent with any other vented appliance or stove. This appliance must be vented horizontally to the outside with a sealed 4” single wall vent pipe.
8 6 720 606 601 Fig 4 : Some V ent ing Guide Suggestions An approved side wall vent terminal must be used when the water heater is vented through a side wall.
9 6 720 606 601 Fig 5: Side wall exit locations for mechanical draft vent terminals SOFFIT VENT HOOD 7’ MINIMUM ABOVE PUBLIC WALKWA Y ONE FOOT ABOVE GRADE 3’ ABOVE ANY FORCED AIR INLET WITHIN 10.
10 6 720 606 601 Fig. 6 - Appliance pressure regulator (with directional arrow on reverse side pointing up) GAS LINE SIZING The pressure regulator provided with the heater is adjusted to deliver the proper gas pressure (as indicated on the rating plate and in the manual for altitude up to 2000 feet (660 meters) above sea level.
11 6 720 606 601 GAS PIPING, CONNECTIONS Before connecting the gas supply, c heck the rating plate on the right side of the front cover to be sure that the heater is rated for the same gas to which it will be connected.
12 6 720 606 601 Fig.7 - Water valve and water connectors, top view W A TE R CONN EC TIO N S Install the heater centrally in the building if possible and make hot water piping runs as short as possible When facing the heater , the cold water inlet will be on the right and the hot water outlet on the left.
13 6 720 606 601 ELECTRICAL CONNECTIONS WARNING: For safety reasons, disconnect the power supply to the heater before any service or testing is performed. WARNING: This heater must be electrically grounded in accordance with the most recent edition of the National Electrical Code , N FP A 70.
14 6 720 606 601 O PERA T I N G INST R UC T ION S Before operating the heater , make sure that the system is filled with water. Open the cold water inlet supply to the heater fully .
15 6 720 606 601 Fig. 1 2 - Charact eristic Pilot Flame Flame sensor Piezo Electrode W at e r V alve ( Part # 8 7 07 002802): The water valve on this heater should be serviced periodically.
16 6 720 606 601 3. W ater flow is not sufficient to act ivate heater. W ater flow rate at faucet is below minimum flow needed to activate heater . W hen temperature adjustment knob is turned all the way clockwise, the AquaStar model 1 25FX requires 1 /2 gallon per minute flow to activate the heater .
17 6 720 606 601 Mineral deposits can eventually (3-5 years in hard water areas) corrode the water valve parts to a point where they will need replacing. Any sign of moisture at the bleed hole is a sign that the water valve needs to be replaced immediat ely .
18 6 720 606 601 WA TE R IS T OO H O T 1 . T emperature S election too high T urn the temperature adjustment knob counter-cloc kwise (to the left) to lower the maximum water temperature. Note: This will increase the activation flow rate. 2 . Inlet water temperature is very warm (60°-75°F) Reduce inlet gas supply to lower the heaters degree rise.
19 6 720 606 601 Fig. 1 5 - Diagram of AquaStar 1 25FX 1 . Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. electric control box 8. Power cord 9. on/off switch 1 0. T emperature adjustment selector 1 1 .
20 6 720 606 601 Fig. 1 6 - I NTE RI OR CO MP ON E NTS DIA G RAM AN D P ARTS LIST.
21 6 720 606 601 Fig . 1 6 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 1 25FX 1 Cover 8 705 421 775 2T e m p era tur e ad j ustment kno b 8 702 000 111 3T e m p era tur e ad j ustment co l lar 8 700 .
22 6 720 606 601 Fig . 1 7 - Flow chart of Aquastar 1 25 F X.
23 6 720 606 601 L I M ITE D W AR R ANT Y Aquast ar General Aquastar water heaters are warranted by the Manufacturer ( B OSC H ) through Controlled Energy C orp.
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park W ait sfield, V ermont 05673 Phone 800-642-31 1 1 Fax (802) 496-6924 ww w .controlledenergy .com/tech techsupport@controlledenergy .com VULCANO T ermodomésticos S.
Ein wichtiger Punkt beim Kauf des Geräts AquaStar 125FX LP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie AquaStar 125FX LP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für AquaStar 125FX LP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von AquaStar 125FX LP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über AquaStar 125FX LP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon AquaStar 125FX LP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von AquaStar 125FX LP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit AquaStar 125FX LP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei AquaStar 125FX LP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.