INST ALLA TION AND OPERA TING INSTRUCTIONS FOR AQ-1 POWER VENT KIT DESIGNED FOR BOSCH 425 HN W A TER HEA TERS AQUAST AR 125 B W A TER HEA TERS INCLUDING AQUAST AR MODELS: 125HX • 125BS • 125X • 125BL T ABLE OF CONTENTS contents with an AQ-1 power vent p.
AQ-1 Power vent kit Parts included: Spillage Switch Kit 1. 185º F linear spillage switch mounted on an angled bracket and equipped with 36 inch cables connected to one eyelet terminal and one 1/4" quick connect terminal 2. Spillage switch mounting screw 3.
Power V ent Kit CAUTION 1. Failure to install, maintain and/or operate the Power V enter in accordance with manufacturer's instruction may result in conditions which can produce bodily injury and property damage.
INSTRUCTIONS ( SEE DIAGRAMS ABOVE ) 1. Mount gas pressure switch by securing it to the chosen location with a screw in each one of the four mounting holes. 2. Use a tube cutter to make a clean cut (not crimped) at each end of the two lengths of the 1/4" aluminum tubing.
e. Hand thread the pressure tap fitting into the heater's burner manifold. Use a small amount of an appropriate thread sealant on the male end of the fitting. Over tightening of the fitting will break it. f. Guide the end of the tube into the com- pression fitting.
1. The ECO is mounted on the lower left outlet water pipe. (See figure C) a. Remove one lead connecting to ECO terminal, it does not matter which one is disconnected. b. Attach 1/4" quick connect terminal end of linear spill switch cable to now exposed terminal of the ECO.
COMMON SETUP Mount gas pressure switch against wall 6 125B Model shown See Figure D, page 5 for location of Linear S pillage Switch V ent Hood (see freeze prevention information on page 2) Power vent motor 4" single wall pipe* (galvanized or stainless steel) or 4" B-type vent*.
CAUTION Failure to follow these installation instructions may violate applicable national and/or local codes The vent system must terminate so that proper clearances are maintained as cited in the National Fuel Gas Code, ANSI Z223.
INSTRUCTIONS (DO NOT BEGIN THESE PROCEDURES UNTIL VENT HOOD HAS BEEN INST ALLED) 1. Remove vibration mounts, nuts and washers from parts bag. Install on power venter as shown in (Figure H). 2. T o prevent vibration, securely support power venter from ceiling or joist using a plumber's strap or wire fastened to the vibration mounts.
3. Connect the RED wire from the jacketed cable onto the common terminal of the gas pressure switch. (See Figure I) NOTE: If the distance between the power venter and the gas pressure switch is greater than the length of the cable, splice a section of 2 conductor , PVC sheathed, 105º C thermostat cable to the supplied cable.
SAFETY INTERLOCK TEST 1. Open the gas supply to the water heater . 2. Remove the vent pipe from the vent connec- tor on the top of the water heater . 3. Block the vent connector with sheet metal or other noncombustible material. 4. Turn on the hot water supply to allow the burner to activate.
11 HEA TER ECO SAFET Y INTERLOCK DIAGRAM LINEAR LIMIT SPILLAGE SENSING SWITCH 185º MANUAL RESET BLACK.
1. Attach this template to the interior of the wall the V ent Hood will be penetrating. 2. Insure that proposed vent termination clear- ances are met before cutting opening through wall. Using a 1/2" drill bit, drill two pilot holes where noted on this template.
Ein wichtiger Punkt beim Kauf des Geräts AquaStar 125BS (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie AquaStar 125BS noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für AquaStar 125BS - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von AquaStar 125BS reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über AquaStar 125BS erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon AquaStar 125BS besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von AquaStar 125BS verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit AquaStar 125BS. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei AquaStar 125BS gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.