Benutzeranleitung / Produktwartung P521Ua des Produzenten Lux Products
Zur Seite of 30
CAUTIONS AND W ARNINGS . . . . . . . . . . 2 SYSTEM COMP A TIBILITY . . . . . . . . . . . . 3 FEA TURES . . . . . . . . . . . . . . . . . . . . . . . 4 TOOLS YOU MA Y NEED . . . . . . . . . . . . . . 4 MOUNTING LOCA TION . . . . . . . . . . . . . . 5 REMOVE OLD THERMOST A T .
2 • This thermostat requires batteries to opera te and failure or sub-standard performance of the batteries may impair or prevent the correct operation of the thermostat. Use Duracell ® or Energizer ® alkaline batteries ONL Y for all LUXPRO thermostats requiring batteries.
HOLD S E T R U N D AY/ T IM E T EM P P RO G A IR FI LT ER T E MP E RAT U RE H E AT O FF C OO L F A N A U TO O N E ME R N EX T LCD Display Screen P521Ua UP , DOWN and HOLD Buttons Set Slide Switch Fan Mode Switch System Mode Switch The electrical rating for this thermostat is 1.
• 1 or 2-Heat / 1-Cool, 5/2-day programming • Universal Compatibility for all system types • Weekdays and Weekends can be programmed separately • Exclusive LUX ® Speed Slide T M for easy prog.
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, please follow these general guidelines: 1. Mount the thermostat on an inside wall, about 5 ft. (1.
1. Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean off any corrosion present. 2. F ill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat’ s normal opera tion. 3. Separate new thermostat housing using your thumb and index finger .
WIRING DIAGRAM NOTES: (Important, please read all notes before connecting wires) • If the information provided in the following wiring diagrams does not clearly represent or match your system, please refer to the “TECHNICAL ASSIST ANCE” section of this manual, and contact us before removing any of your existing thermostat wiring.
8 #1 CONVENTIONAL: HEA TING ............................................................9 1-ST AGE OR 2-ST AGE 2 , 3 , 4 , 5 W I R E S #2 CONVENTIONAL: HEA TING .......................................................... 1 0 3-WIRE ZONE V AL VE 3, 4 WIRES #3 CONVENTIONAL: COOLING .
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W X F G B* W2 RH V R W1 A W2 O B C G Y RC RH 1-ST AGE OR 2-STAGE, HEA TING ONL Y (INCLUDING MILLIVOL T) (2-.
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X B* C RH V R W1 4 W A W1 A W2 O B C G Y RC RH HOT WA TER HEA TING ONL Y (WITH A 3-WIRE ZONE V AL VE) Factory RH.
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X F G Y1 6 Y B* RC V R W1 A W2 O B C G Y RC RH 1-ST AGE, COOLING ONL Y Factory RH-RC Jumper Wire Installed #3 C .
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC RH RC V R Y1 6 Y F G X W1 4 W B* W1 A W2 C G O B Y RC RH CONVENTIONAL (NON HEA T PUMP) 1-ST AGE HEATING AND 1-ST.
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W2 RH RC V R Y1 6 Y F G X W1 4 W B* W1 A W2 C G O B Y RC RH CONVENTIONAL (NON HEA T PUMP) 2-ST AGE HEATING AND 1.
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X B* C R V RH R V RC Y1 6 Y F G W1 4 W W1 A W2 O B C G Y RC RH CONVENTIONAL (NON HEA T PUMP) 1-STAGE HEA TING AN.
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC O X F G Y1 6 Y B* RC V R W1 A W2 O B C G Y RC RH SINGLE-ST AGE HEAT PUMP SYSTEM WITH NO AUX OR EMERGENCY HEA T #.
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC CUSTOMER INST A LLED Y -W1 Jumper Wire X B* C W3 W W2 O F G Y1 6 Y RC V R W1 A W2 O B C G Y RC RH 2-HEA T / 1-CO.
INST ALL BA TTERIES INTO THERMOST A T : Install two brand new Energizer ® o r DURACELL ® “AA ” size alkaline (only) batteries, into the thermosta t’ s battery compartment.
with or without a demand for heating or cooling, even when the System Mode switch is in the OFF position. NOTE: The Fan Mode switch only works if your system provides a wire for the thermostat’ s “G” wire terminal, to control a blower fan.
Setup options for how the thermostat will function, along with choosing your particular system type, are performed using a menu on the display screen. TO ACCESS THE SETUP MENU: Move the System Mode switch into the OFF position, and then hold down the EMER button for approximately 5 seconds until the screen changes.
ITEM #07 (DLA Y = DELA Y TIME): [5, default] Thermostat waits 5 minutes before turning the system back on after it was last run. This internal delay prevents rapid cycling and provides equipment protection. The 5 minute setting is fine for most applications.
SET D A Y AND TIME: Place the Set Slide Switch into the DA Y/TIME position. With the day flashing, press UP or DOWN to set the day of the week. Press NEXT and the clock time will start flashing. Use UP or DOWN to set the time, making sure the AM/PM indication is correct.
characteristics, you should refer to your heat pump literature to determine when to disable the heat pump and run in Emergency Heat mode. In general for most heat pump systems, use Emergenc y Hea t mode whenever the outside temperature is less than 32°F (0°C) degrees.
By default, this thermostat has 4 separate program periods for both Heat and Cool mode, they are: MORN, DA Y , EVE, and NITE. Each period ends at the start time of the following period. The heat programs are set in HEA T mode, and the cool programs are set in COOL mode.
TEMPERA TURE CALIBRA TION: The internal temperature sensor in this thermostat is accurately calibrated at the factor y , and in most cases alterations to this setting should not be needed.
NEXT button to accept the setting. If the code you tried was not correct, the thermostat will exit and return to the Normal Run screen with no changes made. If the entered code is correct, the screen will add the word “SET” and display the current heat set temperature limit.
KEYP AD LOCKOUT : Y ou can lock the front panel buttons to prevent unauthorized tampering of your thermostat settings. NOTE: These keypad lock instructions need to be performed in a timely manner .
TO RESET THE FIL TER USAGE COUNTER: Move the Set Slide switch to the “AIR FIL TER” position. The three small digits at the top of the screen tell you the quantity of filter days remaining. Press both the UP and DOWN buttons together , and the usage counter will return to the beginning of the value that it originally started counting from.
This thermostat is powered by two “AA ” Alkaline batteries. The batteries should be replaced A T LEAST once per year to ensure reliable operation (or sooner if “LO BA TT” appears in the display screen). The batteries are located on the back of the thermostat’ s circuit board.
If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our T echnical Assistance department at 856-234-8803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday .
Mercury is considered to be a hazardous material. If this product is replacing a thermostat that contains mercur y in a sealed tube, contact your local waste management authority for instructions regarding recycling and proper disposal. It may be unlawful in your state to place it in the trash.
Ein wichtiger Punkt beim Kauf des Geräts Lux Products P521Ua (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lux Products P521Ua noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lux Products P521Ua - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lux Products P521Ua reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lux Products P521Ua erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lux Products P521Ua besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lux Products P521Ua verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lux Products P521Ua. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lux Products P521Ua gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.