Benutzeranleitung / Produktwartung SG des Produzenten Linear
Zur Seite of 32
BGUS /BGUS-D SG/SG-D INST ALL A T ION GUIDE BGUS BGUS-D SG SG-D Operator models contained in this manual conform to UL325 standard f or use in Class I, II, III, and IV applications USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free FAX (800) 468-1340 www .
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -2- T ABLE OF CONTENTS CAUTION! ONL Y QUALIFIED SERVICE TECHNICIANS SHOULD WORK ON AN LINEAR BARRIER GA TE OPERA TOR PRE-INST ALLA TION INFORMA TION Gate Operator Classi fi cations ........
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -3- GA TE OPERA TOR CLASSIFICA TIONS All gate operators can be divided into one of four different classi fi cations, depending on their design and usage.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -4- USE COPPER WIRE ONL Y! 1 . Select from the chart at the bottom of this page corresponding to the model, voltage and horsepower rating of your operator . 2. The distance shown on the chart is measured in feet from the operator to the power source.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -5- MOUNTING INSTRUCTIONS BGUS/BGUS-D•SG/SG-D INST ALLA TION ON CONCRETE CURB 1. Uncrate the gate. Avoid damaging the cabinet fi nish. 2. Leave the machine bolted to the bottom pallet until ready to install.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -6- BARRIER GA TE ARM INST ALLA TION FOR MODEL BGUS/BGUS-D 1 . Make sure the barrier gate is in the full closed position 2. With someone’s assistance, lift the arm (#2) up to a height even with the barrier gate fl ange.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -7- BARRIER GA TE ARM INST ALLA TION FOR MODEL SG/SG-D 1. Assemble the SG arm on the ground fi rst, making sure to leave all fasteners loose, including the spreader arms (#4 & #7 above).
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -8- ELECTRICAL CONNECTION AND ADJUSTMENTS All LINEAR gate operators are supplied with a power disconnect switch to turn on and off the power supply available to the operator .
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -9- Auto Close Timer Adjustment: This 270-degree adjustable potentiometer will signal the operator to close automatically , from the fully open position, provided no open, reversing or obstruction signals are present.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -10- TERMINAL CONNECTION DESCRIPTIONS TERMINALS FUNCTION DESCRIPTION OF FUNCTION 24V AC 24V AC Provides 24V olt AC power for accessories. 24V AC N Note: DC models will NOT have 24V olt AC power available.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -11- CURRENT SENSING ADJUSTMENTS Because gates vary in construction and may have different force requirements in the open and close directions to move, the LINEAR control board has separate Multi-turn potentiometers for adjusting in both directions independently .
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -12- ONBOARD L.E.D. INDICA TOR DESCRIPTIONS Control Board L.E.D. Indicators: OPEN This indicator is lit when an open signal is present. This signal can come from such devices as button stations, radio receivers, keypads and telephone entry systems.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -13- BGUS-D • SG-D CHARGER BOARD SLEEP MODE When primary AC power is not available, the operator will continue to operate in battery only mode if the charger board is set in its RUN mode ( see Battery Backup Charger Con fi guration ).
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -14- CONTROL and ACCESSORY CONNECTION ILLUSTRA TIONS.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -15- CONTROL and ACCESSORY CONNECTION ILLUSTRA TIONS.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -16- CONTROL and ACCESSORY CONNECTION ILLUSTRA TIONS.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -17- TROUBLESHOOTING Operator fails to start: A. If the operator has been running a large number of cycles, the motor may have gotten hot and tripped the overload. Allow the motor to cool down and press the overload reset button in bottom of motor .
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -18- MODEL BGUS MECHANICAL P ARTS EXPLODED VIEW.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -19- MODEL BGUS MECHANICAL P ARTS LIST Ref. Part No. Number Description 2 21 10-781* Welded Cabinet Assembly 3 2100-372* Enclosure Door 5 2.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -20- MODEL BGUS-D MECHANICAL P ARTS EXPLODED VIEW.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -21- MODEL BGUS-D MECHANICAL P ARTS LIST Ref. Part No. Number Description 2 21 10-781* Welded Cabinet Assembly 3 2100-372* Enclosure Door 5.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -22- MODEL SG MECHANICAL P ARTS EXPLODED VIEW.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -23- MODEL SG MECHANICAL P ARTS LIST Ref. Part No. Number Description 1 21 10-780* Welded Cabinet Assembly 2 21 10-318* Enclosure Door 5 22.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -24- MODEL SG-D MECHANICAL P ARTS EXPLODED VIEW.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -25- Ref. Part No. Number Description 1 21 10-780* Welded Cabinet Assembly 2 21 10-318* Enclosure Door 5 2220-008 Lock Assembly with Key 6 .
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -26- MODEL SG/SG-D ARM P ARTS LIST Ref. Part No. Number Description 2700-082 Arm Assembly , complete with hardware 2700-082-NOHDWE Arm Asse.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -27- MODELS BGUS/SG CONTROL BOX P ARTS LIST REF NO. P ART NO. DESCRIPTION 1 2100-1778 Control Box Wrapper 2 2100-1761 T erminal Strip Bracket, output side 3 2100-1762 T erminal Strip Bracket, input side 4 2300-735 Heyco Bushing, 1.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -28- MODEL BGUS-D • SG-D CONTROL BOX P ARTS LIST REF NO. P ART NO. DESCRIPTION 1 2100-1778 Control Box Wrapper 2 2200-876 Plunger , Spring Loaded 3 2100-1762 T erminal Strip Bracket, Input Side 4 2100-1761 T erminal Strip Bracket, Output Side 5 2200-122 Heyco Bushing, .
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -29- BA TTERY MAINTENANCE The gel-cell batteries in this operator require no routine maintenance.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -30- PREVENT A TIVE MAINTENANCE GENERAL: LINEAR gate operators are designed for many years of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance.
MODEL BGUS/BGUS-D • SG/SG-D OPERA TOR INST ALLA TION GUIDE -31- sso 3 Imperial Oil MA TERIAL SAFETY DA T A SHEET Date Prepared: February 02, 1996 Supersedes: January 07, 1995 MSDS Number: 225570 Cette fi che signaletique ast aussi disponible en francais 1.
USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free FAX (800) 468-1340 www .linearcorp.com 5/19/2009 P686 X3 Copyright © 2009 Linear LLC.
Ein wichtiger Punkt beim Kauf des Geräts Linear SG (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Linear SG noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Linear SG - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Linear SG reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Linear SG erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Linear SG besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Linear SG verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Linear SG. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Linear SG gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.