FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Safety .............................................................................................................................i-iv ________________________________________________________________________ Installation .
A-1 INST ALLA TION MINIFLEX A-1 TECHNICAL SPECIFICA TIONS - MINIFLEX PORT ABLE FUME EXTRACTOR ( K2376-1) INPUT PHYSICAL DIMENSIONS OPERA TING CAP ACITY Min.
A-2 INST ALLA TION MINIFLEX A-2 GENERAL DESCRIPTION The Miniflex has been specifically designed for extracting and/or filtering welding fume. It is a high vacuum, low volume system that excels in the design and ease of handling. It can be completely disassem- bled in a matter of minutes for cleaning and mainte- nance.
B-1 OPERA TION MINIFLEX B-1 Read and understand this entire section before operating your Miniflex. SAFETY PRECAUTIONS Always operate this equipment with the filters installed and covers in place as these provide maximum protection from moving parts and insure proper vacuum operation and cooling air flow.
B-2 OPERA TION B-2 MINIFLEX HIGH AND LOW MODE • In high mode, both motors are working at 100% capacity, extracting 135 CFM (230 m 3 /hr), (Figure B.2, Item B). • In low mode, both motors operate at 70% capacity, extracting 94 CFM (160 m 3 /hr). MANUAL VS.
C-1 ACCESSORIES C-1 MINIFLEX GENERAL OPTIONS / ACCESSORIES The following options/accessories are available for your MINIFLEX Portable Fume Extractor from your local Lincoln Distributor. See Miniflex brochure Publication E13.11. EN 20 Extraction Nozzle - Order K2389-5 The EN 20 nozzle is designed for a wide array of welding applications.
D-1 MAINTENANCE D-1 The particulate matter collected in the unit may be dangerous to your health. Take necessary precau- tions so that you and your fellow workers do not breathe dust and particulate. Wear a suitable respirator when disposing of the particulate.
D-2 MAINTENANCE D-2 Replacing the LongLife-H™ Filter with Integrated Aluminum Mesh Pre-separator 1. Remove electrical cord of Miniflex unit from electri- cal outlet. 2. Loosen the side clips (A). 3. Remove the top cover (B) from the machine. 4. Remove LongLife-H™ Filter (C).
D-3 MAINTENANCE D-3 MINIFLEX A. Side Clips B. T op Cover C. LongLife-H™ Filter D. Main Filter Seals E. Outlet Cover F . HEP A Filter G. Carbon Brushes H.
E-1 TROUBLESHOOTING E-1 MINIFLEX If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 MINIFLEX Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE CAUSE RECOMMENDED COURSE OF ACTION Motor does not start. Motor stops automatically. Poor suction. Unit will not sense current. Unit automatically cycles between low and high speeds.
F-1 WIRING DIAGRAM F-1 MINIFLEX NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Ein wichtiger Punkt beim Kauf des Geräts Lincoln Electric MINIFLEX IM857 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lincoln Electric MINIFLEX IM857 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lincoln Electric MINIFLEX IM857 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lincoln Electric MINIFLEX IM857 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lincoln Electric MINIFLEX IM857 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lincoln Electric MINIFLEX IM857 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lincoln Electric MINIFLEX IM857 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lincoln Electric MINIFLEX IM857. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lincoln Electric MINIFLEX IM857 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.