Benutzeranleitung / Produktwartung IM514-A des Produzenten Lincoln Electric
Zur Seite of 30
OPERA TOR’S MANUAL Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
LINCOLN ELECTRIC ELECTRIC ® ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87.
LINCOLN ELECTRIC ELECTRIC ® FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
LINCOLN ELECTRIC ELECTRIC ® iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi MASTER T ABLE OF CONTENTS FOR ALL SECTIONS Page Installation .......................................................................................................Section A Technical Specifications .................................................
A-1 INST ALLA TION CLASSIC I A-1 LINCOLN ELECTRIC ELECTRIC ® TECHNICAL SPECIFICA TIONS – CLASSIC I Product Name Description Horsepower Operating Speeds Displacement Ignition Capacities Continental TM27 4 Cylinder 4 Cycle Water-Cooled Gasoline Engine 38 HP @ 1450 RPM Full Load: 1450 RPM High Idle: 1600±50 RPM Low Idle: 1000 RPM 164.
A-2 INST ALLA TION CLASSIC I A-2 GENERAL DESCRIPTION The Classic I is a heavy duty engine driven DC arc welding power source capable of providing DC con- stant current output for stick welding and DC TIG welding.
A-3 INST ALLA TION CLASSIC I A-3 LINCOLN ELECTRIC ELECTRIC ® PRE-OPERA TION INST ALLA TION Safety Precautions Exhaust Spark Arrester Some federal, state, or local laws may require that engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard.
A-4 INST ALLA TION CLASSIC I A-4 LINCOLN ELECTRIC ELECTRIC ® P olarity Control and Cable Sizes With the engine off, route the electrode and work cables through the strain relief bracket on the base and connect to the studs located below the fuel tank mounting rail.
A-5 INST ALLA TION CLASSIC I A-5 LINCOLN ELECTRIC ELECTRIC ® PRE-OPERA TION SER VICE READ the engine operating and maintenance instruc- tions supplied with this machine. ------------------------------------------------------------ Oil This unit is supplied from the factory with the engine crankcase filled with a high quality SAE 10W/30 oil.
B-1 OPERA TION B-1 CLASSIC I ENGINE OPERA TION Operate the welder with the doors closed. Leaving the doors open changes the designed air flow and can cause overheating. Starting the Continental TM27 Engine a) Turn the Idler control switch to “HIGH”.
B-2 OPERA TION B-2 CLASSIC I Control of W elding Current DO NOT TURN THE “CURRENT RANGE SELEC- TOR” WHILE WELDING because the current may arc between the contacts and damage the switch. ------------------------------------------------------------------------ The “Current Range Selector” provides five overlap- ping current ranges.
B-3 OPERA TION B-3 CARBURET OR DEICING KIT USA GE INSTR UCTIONS FOR SEA- SONAL CHANGE O VER ELECTRIC SHOCK can kill. • Do not operate with panels open. • Disconnect NEGATIVE(-) BATTERY LEAD before servicing. • Do not touch electrically live parts.
C-1 A CCESSORIES C-1 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® OPTIONAL FEA TURES (field Installed) Accessory Set (K702) Includes 35 ft (10.7m) electrode and 30 ft (9.1m) work cables, headshield, work clamp, and electrode holder. CV Adapter (K384) K6090 thru -4 only Provides constant voltage output for semiautomatic welding.
D-1 MAINTENANCE D-1 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® MAINTENANCE General Instructions 1. Blow out the welder and controls with an air hose at least once every two months. In particularly dirty locations, this cleaning may be necessary once a week.
D-2 MAINTENANCE D-2 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Bearings This welder is equipped with a double-shielded ball bearing having sufficient grease to last indefinitely under normal service. Where the welder is used con- stantly or in excessively dirty locations, it may be nec- essary to add one-half ounce of grease per year.
E-1 TR OUBLESHOO TING E-1 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TR OUBLESHOO TING E-2 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable .
E-3 TR OUBLESHOO TING E-3 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable .
E-4 TR OUBLESHOO TING E-4 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable .
E-5 TR OUBLESHOO TING E-5 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable .
E-6 TR OUBLESHOO TING E-6 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® ELECTR ONIC IDLER TROUBLESHOO TING GUIDE Engine Will Not Return to Idle in Approximately 15 Seconds Set Idler Control Switch to the Auto Position Check to See Whether Oil Pressure Light is On and Alternator is Charging Light Off Light On If Oil Light is O.
F-1 DIA GRAMS F-1 CLASSIC I MOTOR + GROUND GROUND TO BASE TO ENGINE EXC ALTERNATOR S B + STARTING OIL PRESSURE SWITCH G AUX POWER RECEPTACLE 600B B R TO EXCITER OUTPUT - + E E B F1 15A. TO PLUGS IGNITION COIL DISTRIBUTOR + - ONLY. FUSE IN CIRCUIT ON C.
F-2 DIA GRAMS F-2 CLASSIC I PART NO. WELDER A B C D E F G H A CONTROL PANEL F G B H D E C O HOLE O MOUNTING HOLE N.A. N.B. NOTES: OIL AND WATER IN ENGINE, BUT NO FUEL. N.A. CENTER OF GRAVITY WITH O S10766-7 J J K K DIMENSION PRINT S10766 METRIC cm (ENGLISH in.
Now A vailab le...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “Bible” of the arc welding industry. This printing will go fast so don’t delay.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Ein wichtiger Punkt beim Kauf des Geräts Lincoln Electric IM514-A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lincoln Electric IM514-A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lincoln Electric IM514-A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lincoln Electric IM514-A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lincoln Electric IM514-A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lincoln Electric IM514-A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lincoln Electric IM514-A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lincoln Electric IM514-A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lincoln Electric IM514-A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.