Benutzeranleitung / Produktwartung IDEALARC SVM136-A des Produzenten Lincoln Electric
Zur Seite of 102
SVM136-A Nov ember 1997 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with saf ety in mind. How ev er , your o verall saf ety can be in- creased by proper installation . . . and thoughtful operation on your part.
SAFETY i i IDEALARC CV -400 FOR ENGINE powered equipment. 1.a. T ur n the engine off bef ore troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b . Operate engines in open, well-v entilated areas or vent the engine e xhaust fumes outdoors.
SAFETY ii ii IDEALARC CV -400 ARC RA YS can burn. 4.a. Use a shield with the proper filter and cov er plates to protect your e yes from sparks and the ra ys of the arc when welding or obser ving open arc welding. Headshield and filter lens should conform to ANSI Z87.
IDEALARC CV -400 FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse bo x before w or king on the equipment. 8.b . Install equipment in accordance with the U.S . National Electrical Code, all local codes and the manuf acturer’s recommendations.
SAFETY iv iv IDEALARC CV -400 PRÉCA UTIONS DE SÛRETÉ P our votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté P our Soudage A L ’Arc 1.
MASTER T ABLE OF CONTENTS FOR ALL SECTIONS v v IDEALARC CV -400 Page Safety ............................................................................................................................... ................ i-i-v Installation ...........
T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 IDEALARC CV -400 Installation ............................................................................................................................. Section A T echnical Specifications .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-2 A-2 IDEAL.
Read this entire installation section befor e you start installation. SAFETY PRECA UTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live par ts such as output ter minals or inter nal wiring. • Insulate yourself from the work and ground.
GROUND CONNECTION The frame of the welder m ust be grounded. An ear th grounding lead must be connected to the g rounding terminal, mar ked on the input bo x floor with the symbol (See Figure A.2 ). Ref er to T echnical Specifi- cations page f or proper ground wire size.
Hav e a qualified electrician connect the input power leads to the L1, L2, and L3 terminals of the input con- tactor . F ollow all national and local electrical codes. Use a three-phase line. Install the reconnect panel jumper links (see Figure A.3) f or the proper input volt- age.
RECONNECT PR OCEDURE Multiple input voltage w elders are shipped from the f ac- tor y connected f or the highest voltage listed on the machine's rating plate . Before installing the welder , be sure the reconnect panel is connected f or the proper v oltage.
INST ALLA TION A-7 A-7 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 2 1 + - FIGURE A.5 OUTPUT TERMINAL CONNECTIONS 1.
CONNECT WIRE FEEDERS The wire f eeder control cable can connect to the CV - 400 at the 14-pin amphenol on the front of the machine (with the appropriate adapter cable) or the terminal strips behind the hinged control panel cover . A str ain relief bo x connector is provided f or cable access to the terminal str ips.
Section B-1 Section B-1 IDEALARC CV -400 T ABLE OF CONTENTS - OPERA TION SECTION - Operation ............................................................................................................................... Section B Saf ety Precautions .
OPERA TION B-2 B-2 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TING INSTRUCTIONS Read and understand this entire section of operating instructions before operating the machine.
GENERAL DESCRIPTION The IDEALARC CV -400 is an SCR controlled three- phase input, DC output power source f or welding. It uses a single range potentiometer control.
WELDING CAP ABILITY The CV -400 has the f ollowing duty cycle ratings. If the duty cycle is e xceeded, a thermal protector will shut off the machine output until it cools to nor mal operating temperature. The amber ther mal protection indicator light will tur n on until the machine cools.
1. PO WER SOURCE PILO T LIGHT : This light indi- cates that the pow er source input contactor is ener- gized (closed). This also means that the main power transf or mer and all auxiliar y control transf or mers are energized. 2. ON/OFF PO WER T OGGLE SWITCH: Energizes or deengergizes the input contactor .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-6 B-6 IDEALARC CV -400 WELDING OPERA TION LOCAL CONTROL The f ollowing procedures are f or using the CV -400 in the local control mode of operation.
OVERLOAD PROTECTION The pow er source is ther mostatically protected with pro ximity ther mostats against ov er load or insufficient cooling. One ther mostat is located on the nose of the center bottom primar y coil and a second thermostat is attached to the lead connecting the secondaries.
NO TES B-8 B-8 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
T ABLE OF CONTENTS - A CCESSORIES - Accessories ........................................................................................................................... Section C Options/Accessories .................................................
OPTIONS/A CCESSORIES The f ollowing options/accessories are av ailable f or your CV -400 from your local Lincoln Electric Distributor . F ACTOR Y INST ALLED OPTIONS Diode Option - This inter nally installed option allows use of the cold star t and cold electrode sensing fea- tures of the NA-3, NA-5, or NA-5R automatic wire f eed- ers.
ELECTRIC SHOCK can kill. • Only qualified personnel should per- f or m this maintenance. • T ur n the input power OFF at the dis- connect s witch or fuse box bef ore working on this equipment. • Do not touch electrically hot par ts. • Insulate yourself from w or k and ground.
5. Extend wire feeder control cab le lead #21 so it can be connected directly to the work piece. a. Make a bolted connection using A WG #14 or larg- er insulated wire. T ape the bolted connection with insulating tape. b . An S-16586- X remote voltage sensing work lead is av ailable f or this pur pose.
A CCESSORIES C-5 C-5 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 5. Extend wire feeder control cab le lead #21 so it can be connected directly to the work piece.
A CCESSORIES C-6 C-6 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE C.
CONNECTING THE LN-8 OR LN-9 TO THE IDEALARC CV -400 1. Set the CV -400 POWER toggle switch to the OFF (0) position. 2. Disconnect main AC input power to the CV -400. 3. Connect the wire feeder control cable leads to the CV -400 terminal strip as shown in Figur e C.
NO TES C-8 C-8 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section D-1 Section D-1 IDEALARC CV -400 T ABLE OF CONTENTS -MAINTENANCE- Maintenance .................................................................................
SAFETY PRECA UTIONS ELECTRIC SHOCK can kill. • Only qualified personnel should perf orm this maintenance. • T ur n the input pow er OFF at the discon- nect s witch or fuse box bef ore working on this equipment. • Do not touch electrically hot par ts.
MAINTENANCE D-3 D-3 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 9 10 11 8 7 6 5 1 2 3 4 FIGURE D.1 Major Component Locations 1.
NO TES D-4 D-4 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section E-1 Section E-1 IDEALARC CV -400 Theory of Operation ..........................................................................................................
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INPUT LINE V OL T A GE, CONT.
THEOR Y OF OPERA TION E-3 E-3 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Re.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THEOR Y OF OPERA TION E-4 E-4 IDEALARC CV -400 FIGURE E.
SCR OPERA TION A silicon controlled rectifier (SCR) is a three-terminal de vice used to control rather large currents to a load. An SCR acts v er y much lik e a s witch. When a gate sig- nal is applied to the SCR, it is tur ned ON, and there is current flow from anode to cathode .
NO TES E-6 E-6 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section F-1 Section F-1 IDEALARC CV -400 T roub leshooting & Repair Section ................................................................................. Section F How to Use T roubleshooting Guide .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC HO W T O USE TR OUBLESHOO TING GUIDE Ser vice and repair should be perf or med by only Lincoln Electric F actor y T rained P ersonnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRIC SHOCK can kill. Hav e an electrician install and ser vice this equipment.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-4 F-4 IDEALARC CV -400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-5 F-5 IDEALARC CV -400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-6 F-6 IDEALARC CV -400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-7 F-7 IDEALARC CV -400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-8 F-8 IDEALARC CV -400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-9 F-9 IDEALARC CV -400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-11 F-11 IDEALARC CV -400 FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-12 F-12 IDEALARC CV -400 FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-14 F-14 IDEALARC CV -400 INPUT CONT A CT OR TEST (continued) FIGURE F .
TEST FOR CONT ACT CONTINUITY 1. Disconnect the main input supply power to the machine. 2. Remov e the two leads connected to the input con- tactor coil, #233 and X1/#232. See Figure F .4 f or location. 3. Using the external 120V A C supply , apply 120V AC to the ter minals of the input contactor coil.
MAIN TRANSFORMER (T1) V OL T A GE TEST Ser vice and repair should be perf or med by only Lincoln Electric f actor y trained personnel. Unauthorized repairs perf or med on this equipment ma y result in danger to the technician or machine operator and will in validate y our factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-17 F-17 IDEALARC CV -400 TEST PROCEDURE 1. Set the ON/OFF power switch to OFF .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-18 F-18 IDEALARC CV -400 8. Read the meter . a.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-19 F-19 IDEALARC CV -400 12. T est for 115V AC between leads #31 and #32 on the terminal strip.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP .
ST A TIC SCR/DIODE RECTIFIER BRIDGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-22 F-22 IDEALARC CV -400 ST A TIC SCR/DIODE RECTIFIER BRIDGE TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-23 F-23 IDEALARC CV -400 ST A TIC SCR/DIODE RECTIFIER BRIDGE TEST (continued) 8.
A CTIVE SCR TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-25 F-25 IDEALARC CV -400 ACTIVE SCR TEST (continued) TEST PROCEDURE 1.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-26 F-26 IDEALARC CV -400 ACTIVE SCR TEST (continued) 8.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-27 F-27 IDEALARC CV -400 ACTIVE SCR TEST (continued) 9.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-28 F-28 IDEALARC CV -400 This is the typical DC open circuit voltage waveform generated from a properly operating machine.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-29 F-29 IDEALARC CV -400 This is the typical DC open circuit voltage waveform generated from a properly operating machine.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-30 F-30 IDEALARC CV -400 This is the typical SCR gate pulse voltage waveform.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TR OUBLESHOO TING & REP AIR F-31 F-31 IDEALARC CV -400 This is NOT the typical DC output voltage waveform.
INPUT CONT ACTOR (CR1) CLEANING/REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-33 F-33 IDEALARC CV -400 INPUT CONT ACTOR (CR1) CLEANING/REPLACEMENT (continued) FIGURE F .
F AN MOTOR AND BLADE REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-35 F-35 IDEALARC CV -400 F AN MOTOR AND BLADE REMOV AL AND REPLACEMENT (continued) FIGURE F .
SCR/DIODE RECTIFIER ASSEMBL Y REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-37 F-37 IDEALARC CV -400 SCR/DIODE RECTIFIER ASSEMBL Y REMOV AL AND REPLACEMENT (continued) FIGURE F .
SCR REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-39 F-39 IDEALARC CV -400 FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-40 F-40 IDEALARC CV -400 FIGURE F .21 – 1/2” WIDE LEAF SPRING FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-42 F-42 IDEALARC CV -400 SCR REMOV AL AND REPLACEMENT (continued) PROCEDURE FOR THE 5/8 INCH WIDE SPRING 1.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-43 F-43 IDEALARC CV -400 CLAMPING PROCEDURE FOR 1/4-28 CAP SCREWS NOTE: This procedur e can only be used with 1/4-28 cap screws.
MOUNTING OF STUD TYPE DIODES TO ALUMINUM HEA T SINKS Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-45 F-45 IDEALARC CV -400 PROCEDURE 1. Remove the main input supply power to the machine.
MAIN TRANSFORMER REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-47 F-47 IDEALARC CV -400 REMOV AL OF LIFT BAIL 1.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-48 F-48 IDEALARC CV -400 FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-49 F-49 IDEALARC CV -400 FIGURE F .
3. Install the bottom primary coils, one on each of the three legs of the bottom ir on assembly . The coils must be in correct position (left, center , right). Place the coils so that the leads come out at the back of the machine. See Figure F .28 for proper positioning.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-51 F-51 IDEALARC CV -400 MAIN TRANSFORMER REMOV AL & REPLACEMENT (continued) 10.
REASSEMBLING THE MAIN TRANSFORMER INTO THE MACHINE NOTE: The following procedur e assumes you have completely reassembled the transformer coils as described in the procedur e above. The lower iron has r emained in place in the machine. See Figures F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
NO TES F-54 F-54 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Maste.
ELECTRICAL DIA GRAMS G-1 G-1 IDEALARC CV -400 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Electrical Diagrams Section .............................................................................................
ELECTRICAL DIA GRAMS G-2 G-2 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 12-9-94F H2 H3 H4 ELECTRICAL SYMBOLS PER 1 2 4 3 4 PIN 8 PIN J3 J2 CONNECTOR CAVITY NUMBERING SEQUENCE (COMPONENT SIDE OF P.
ELECTRICAL DIA GRAMS G-3 G-3 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC L9270 13 14 15 16 17 18 H2 H3 H4 ELECTRICAL SYMBOLS PER E1537 CONNECTOR CAVITY NUMBERING SEQUENCE (COMPONENT SIDE OF P.
ELECTRICAL DIA GRAMS G-4 G-4 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC IDENTIFICATION PART No.
ELECTRICAL DIA GRAMS G-5 G-5 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC +15V 1W 6.2V DZ12 PILOT R177-R189=68.
ELECTRICAL DIA GRAMS G-6 G-6 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ITEM PART NO.
ELECTRICAL DIA GRAMS G-7 G-7 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Ret.
NO TES G-8 G-8 IDEALARC CV -400 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
Ein wichtiger Punkt beim Kauf des Geräts Lincoln Electric IDEALARC SVM136-A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lincoln Electric IDEALARC SVM136-A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lincoln Electric IDEALARC SVM136-A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lincoln Electric IDEALARC SVM136-A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lincoln Electric IDEALARC SVM136-A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lincoln Electric IDEALARC SVM136-A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lincoln Electric IDEALARC SVM136-A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lincoln Electric IDEALARC SVM136-A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lincoln Electric IDEALARC SVM136-A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.