Thank Y ou! Thank y ou for selectin g the American Power Conversion SmartSlot Series Measure-UPS II . It has been desi g ned for man y y ears of reliable, mainte- nance-free service. Please read this manual! It provides installation and operatin g instructions that will help y ou g et the most from y our accessor y .
Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 Operation Check . . . . . . . . . . . . .
1. Introduction The SmartSlot Measure-UPS II performs temperature and humidit y sensin g , as well as contact monitorin g . Measure-UPS II supports up to four zones of contact monitorin g , each of which supports both normall y open and normall y closed contacts.
Safety Notice The SmartSlot Measure-UPS II UPS accessor y is intended solel y for use in supplementar y surveillance of equipment. APC does not recom- mend this product for life or propert y protection. APC will not know- in g l y sell Measure-UPS II for use in such applications.
2. Installation Use the followin g procedure to install SmartSlot Measure-UPS II : 1. Install and configure an y software or hardware that will be used with Measure-UPS II for data reporting (see software and hard- ware compatibility abov e). 2. Using figure 2 as a guide, install Measure-UPS II in the host SmartSlot.
Do not: • Cov er any of the ventilation holes on the probe • Immerse the probe or place it where de w can be expected to form • Use the probe in an en vironment with chlorine gas or insecti- cides. 5. The contact monitoring connection is a two piece design.
3. Operation Check 1. Confirm the basic operation of Measure-UPS II . Use the data reporting system (see hardware and software compatibility in sec- tion 1) to confirm that Measure-UPS II is w orking.
4. Sensor Zone Connections Connection Information Measure-UPS II supports normall y open and normall y closed loop s y stems, and allows mixin g of normall y open and normall y closed sensors on an y zone. See the fi g ures below for more information on usin g multiple sensors in one zone and for s y stem hookup.
In order to avoid receivin g alarm indications on unused zones, install a j umper wire between the COM and NC connectors for each unused zone. T o use more than one sensor on a zone, follow the dia g ram below . Connect normall y open sensors in parallel and normall y open sensors in series.
See below for a t y pical hookup. Note that in this example s y stem zone 1 is a normall y closed motion zone with power for the passive infrared detector supplied b y Measure-UPS II . Zone 2 is a normall y open zone. Zone 3 is a combination normall y open and normall y closed zone.
5. Sensor Selection Measure-UPS II ma y be used with an y dr y contact closure t y pe sen- sors. The Measure-UPS II sensor inputs are desi g ned to monitor cir- cuits that have no volta g e potential of their own.
6. Maintenance Measure-UPS II requires periodic maintenance. Confirm contact sens- in g usin g the sensor manufacturers recommended intervals and meth- ods. Use the data reportin g s y stem to verif y that each sensor operates as planned. Clean the temperature (or temperature and humidit y ) probe whenever there is a visible buildup of dust.
7. T roubleshooting Problem Possible Cause Solution Constant Alarm on one or more unused zones. Unused zones not jumpered. Connect a wire between the COM and NC terminals of all unused zones (see section 4). Constant low tem- perature and humid- ity readings.
8. Service If the SmartSlot Measure-UPS II requires service: 1. Check Measure-UPS II using the troubleshooting chart in section 7 before calling for service. 2. Note the model number of the Measure-UPS II , the serial number , and the date purchased. See the back cov er of this manual for the correct telephone number and call customer service.
9. Specifications Electrical SmartSlot specification compatible Operatin g volta g e: 16 - 27 Vdc Operatin g current draw: 30 mAdc (exclusive of an y attached sensors) T emperature accurac y : ±2° C (± 3.
10. Declaration of Conformity Application of Council Directives: 89/336/EEC Standards to Which Conformit y is Declared: EN55022, EN50082-1 Manufacturers Name: American Power Conversion 132 Fair g roun.
Limited W arranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obli- gation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products.
Ein wichtiger Punkt beim Kauf des Geräts APC SmartSlot Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie APC SmartSlot Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für APC SmartSlot Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von APC SmartSlot Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über APC SmartSlot Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon APC SmartSlot Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von APC SmartSlot Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit APC SmartSlot Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei APC SmartSlot Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.