Benutzeranleitung / Produktwartung DISTO X310 des Produzenten Leica
Zur Seite of 22
Leica DISTO TM X310 The original laser distance meter.
Leica DISTO TM X310 788479d 1 EN Table of Contents Instrument Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - 2 Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - .
Leica DISTO TM X310 788479d 2 EN Instrument Set-up Introduction The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them.
Leica DISTO TM X310 788479d 3 EN Instrument Set-up Display Horizontal measurement Units Stake out Ceiling area Wall area Circumference Measuring reference 2nd result Area / Volume Tilt angle Info Slop.
Leica DISTO TM X310 788479d 4 EN Operations Switching ON/OFF Clear Message Codes ON OFF 2 sec Device is turned OFF. i Press ON but- ton 2 sec to st art continuous laser mode. 1x Undo last action. 2x Leave actual func- tion, go to de fault operation mode.
Leica DISTO TM X310 788479d 5 EN Operations Multifunctional endpiece i The orientation of the endpiece is automaticall y detected and the zero point is accordingly ad- justed. Distance unit setting Tilt unit setting Switch between the following unit s: 0.
Leica DISTO TM X310 788479d 6 EN Operations Beep ON/OFF Illumination ON/OFF 2 sec simulta ne- ously 2 sec simultane- ously Keypad lock ON Keypad lock OFF 2 sec simulta ne- ously PRESS MINUS 1 withi n .
Leica DISTO TM X310 788479d 7 EN Measuring Functions Measuring single distance 1 Aim active laser at target. 2 8.532 m 3 i Target surfaces: Measuri ng errors can occur when measuring to col- ourless liquids, glass, styrofo am or semi-permeable surfaces or when aiming at high glo ss surfaces.
Leica DISTO TM X310 788479d 8 EN Measuring Functions Area 1 1x 2 Aim laser at first target point. 3 4 Aim laser at sec- ond target point. 24.352 m 2 5 i The result is shown in the main line and the mea sured valu e above. Partial Measurements: Press + or - after starting the fir st measurement.
Leica DISTO TM X310 788479d 9 EN Measuring Functions Volume 1 2x 2 Aim laser at first target point. 3 4 Aim laser at sec- ond target point. 5 6 Aim laser at third target point. 78.694 m 3 7 i The result is shown in the main line and the measured value above.
Leica DISTO TM X310 788479d 10 EN Measuring Functions Triangular area 1 3x 2 Aim laser at first target point. 3 4 Aim laser at sec- ond target point. 5 6 Aim laser at third target point.
Leica DISTO TM X310 788479d 11 EN Measuring Functions Pythagoras (3-point) 1 4x 2 Aim laser a t upper point. 3 4 Aim laser at rec- tangular point. 5 6 Aim laser at lower point. 8.294 m 7 i The result is shown in the main line and the measured distance above.
Leica DISTO TM X310 788479d 12 EN Measuring Functions Pythagoras (partial height) 1 5x 2 Aim laser a t upper point. 3 4 Aim laser at 2nd point. 5 6 Aim laser at rec- tangular point. 2.602 m 7 i The result is shown in the main line and the measured distance above.
Leica DISTO TM X310 788479d 13 EN Measuring Functions Stake out i Two different distances (a and b) can be entered to mark off de- fined measured lengths. 1 2 3 a b b a = b 1 2 3 a b b a = b 1 .000 m 1 6x 1. 01 2 m 2 Adjust value "a". 3 Approve value "a".
Leica DISTO TM X310 788479d 14 EN Measuring Functions Smart Horizontal Mode 1 Aim laser at tar- get. 2 0.032 m 5.204 m 40.8 ° 4.827 m x z x y z y 3 (up to 360° and a transverse tilt of ±10°) i Press key again to switch off horizontal measure- ment.
Leica DISTO TM X310 788479d 15 EN Measuring Functions Memory (20 last displays) Delete Memory 8.294 m 20 20 last displ ays are displayed. 1 8.294 m 20 Navigates trough 20 last displays. 2 The value from the main line can be used for fur- ther calculations.
Leica DISTO TM X310 788479d 16 EN Calibration Calibration of tilt se nsor (Tilt Cali bration) 1 2 sec simultane- ously 2 Place device on absolutely flat s urface. 3 180° 4 Turn the device ho rizontally by 180° and place it again on absolutely flat surface.
Leica DISTO TM X310 788479d 17 EN Technical Data * applies for 100 % target refl ectivity (white painted wall), low background illumination, 25 ºC ** applies for 10 to 500 % target reflectivity, hi gh background illumination, - 10 ºC to + 50 ºC *** Tolerances apply from 0.
Leica DISTO TM X310 788479d 18 EN Message Codes If the message Error does not disappear after switching on the device re peatedly, contact the dealer. If the message InFo appears with a number, press the Clear button and observe the following instructions: Care • Clean the device with a damp, soft cloth.
Leica DISTO TM X310 788479d 19 EN Safety Instructions Permitted use • Measuring distances • Tilt measurement Prohibited use • Using the product without instruction • Using outside the stated limits • Deactivation of safety systems and removal of explanatory and hazard labels • Opening of the equipment by using tools (screwdrivers, etc.
Leica DISTO TM X310 788479d 20 EN Safety Instructions Electromagnetic Compatibility (EMC) WARNING The device conforms to the most stringent requirements of the relevant standard s and regulations. Yet, the possibility of causing interference in other devices cannot be totally excluded.
Leica Geosystems AG CH-9435 Heerbrugg (Switzerland) www.disto.com Leica Geosystems AG, He erbrugg, Swit zer land has been certified as being equipped with a quality system which meets the International Standards of Quality Management and Quality Syst em s (ISO standard 9001) and Environ- mental Management Systems (ISO standard 14001).
Ein wichtiger Punkt beim Kauf des Geräts Leica DISTO X310 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Leica DISTO X310 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Leica DISTO X310 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Leica DISTO X310 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Leica DISTO X310 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Leica DISTO X310 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Leica DISTO X310 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Leica DISTO X310. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Leica DISTO X310 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.