User Manual InRoom SC 60 Hz ACPSC2000 ACPSC3500 ON/OFF MODE SLEEP FAN TEMP TIME InR oom SC.
.
American Power Conversion Legal Disclaimer The information presented in this manual is not warranted by the Am erican Power Conversion Corpora- tion to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed operational and site specific development plan.
.
Content s InRoom SC 60 Hz User Manual i General Information .................. ...................................... 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Save these instruct ions .
InRoom SC 60 Hz User Manual ii Display Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Display Screen Informati on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Function But ton and Indicato r Light Operati on .
1 InRoom SC 60 H z User Manu al General Information Overview Save these instructions This manual contains important instructions that must be followed during the installation of this equipment.
InRoom SC 60 Hz User Manual 2 Safety symbols that may be used in this manual Electrical Hazard: Indicates an electrical hazard which, if not avoided, could result in injury or death. Danger: Indicates a hazard wh ich, if not avoided, could result in severe personal injury or substantial damage to product or other property .
3 InRoom SC 60 H z User Manu al Safety Electrical Hazard: Connect the equipment to a 3-wire AC outlet (two poles plus a ground). The receptacle must be connected to a dedicated, prop erly grounded 120 volt 60Hz branch circui t rated for 20 amp main protection (fuses/circuit breake r).
InRoom SC 60 Hz User Manual 4 S toring the Cooling Unit If the cooling unit will not be installed immediately , replace the packaging to protect from damage and dust.
5 InRoom SC 60 H z User Manu al Inspecting the Cooling Unit Y our cooling unit has been tested and inspected before shipment. T o e nsure that the cooling unit has not been damaged during transit, carefully insp ect the cooling unit imme di ately upon receipt.
InRoom SC 60 Hz User Manual 6 T ools Required Inventory The cooling unit includes the remote control storage bracket, hardware, batteries, the remote control, and the exhaust kit. See “Remote Control” on page 1 7 for more information. See “Exhaust kit” on page 10 for contents.
7 InRoom SC 60 H z User Manu al Component Identification ACPSC2000 and ACPSC3500 Item Description 1 Control panel 2 V ertical air louver 3 Remote contr ol / stora ge 4 Air filter / upper air intake (e.
InRoom SC 60 Hz User Manual 8 Power plug Electrical Hazard: This equipmen t requires an LCDI plug. Use only the power cord supplied with the equipment. Import ant safety feature. The plug of the power cord contains a fuse as a safety feature to protect the cooling unit from damage.
9 InRoom SC 60 H z User Manu al Inst allation Location Requirement s When deciding where to locate the cooling unit, consider cooling needs, air flow , and the location of the el ectrical outlet. The cooling unit can be no more than 2.4 m (8 ft) from the electrical outlet, condenser intake and exhaust access.
InRoom SC 60 Hz User Manual 10 Exhaust Duct Assembly Dry Mode. Exhaust air must be allowed to return to the room in orde r for dehumidification to take place.
11 InRoom SC 60 H z User Ma nual Inst allation. Exhaust air can be vented to the outside th rough the ceiling. The cooling unit should be positioned a minimum of 500 mm (20 in) from any wall; eith er at the back or on the sides. In a dropped ceiling, the ceiling adapter ca n be inst alled in place of one of the ceiling tiles.
InRoom SC 60 Hz User Manual 12 Condensate Drain The InRoom SC utilizes evaporativ e technology , which eliminates the need for a condensate tank. T o manage any excess condensation, a dr ain pan is located in the bottom of the unit. When the drain pan is full, a light will flash on the display and an al arm will sound to alert yo u.
13 InRoom SC 60 H z User Ma nual Continuous draining Note: Continuous drainage is recommended when the unit is used in DR Y mode. Caution: Condensate drainin g is done by gravity . Do not run a drain hose to a drain that is located above the drain po rt of the cooling unit.
InRoom SC 60 Hz User Manual 14 Operation Control Panel Function Button Locations Item Function Description 1 Power control Turn the cooling unit On and Off 2 Mode selection Three mode control settings: Cool, Dehumidi fy , and Fan. The settings are adjusted by pr essing the Mode Control Button .
15 InRoom SC 60 H z User Ma nual Display Interface Display Screen Information Item Function Description 1 Sleep mode indicator Sleep mode is an underco oling mode that is used during times of non- peak heat. Sleep mode is activat ed by setting the timer .
InRoom SC 60 Hz User Manual 16 Function Button and Indicator Light Operation Cooling Mode. In Cool mode the unit attempts to bring the room air temperature down to the set temperature. The fan speed and temperature are adjusted in Cool mode. Note: The room temperature mu st be higher than the set temperature in order for the cooling mode to start.
17 InRoom SC 60 H z User Ma nual Remote Control Caution: 1. Do not drop the remote control. 2. Do not leave the remote contro l exposed to direct sunlight. Note: 1. T o avoid interference, do not use the re mote control within one meter (3 ft) of a television or other electrical appliance 2.
InRoom SC 60 Hz User Manual 18 Set Timer ch anging settings: W ith the cooling unit ON , 1. - Select the mode and press Send . 2. - Select the fan speed and press Send . 3. - Adjust the temperature be tween 16°C and 30°C and press Se nd . 4. - Press the Ti m e r button to see the remaining hours.
19 InRoom SC 60 H z User Ma nual Maintenance Electrical Hazard: Before performing maintenance on th e cooling unit: 1. T urn the cooling unit off. 2. Unplug the cooling unit. W arning: Damage to equipment may o ccur if: 1. Caustic substances are used to clean the cooling unit.
InRoom SC 60 Hz User Manual 20 Empty the condensate drain p an If the cooling unit is not equipped with a drain hose allowing the drain pan to drain, the unit wil l shut down when the drain pan is full. 1. W ith the power off and the unit unplugg ed, move the coo ling unit to an appropriate place to drain the drain pan.
21 InRoom SC 60 H z User Ma nual Caster replacement W arning: T ipping the cooling unit can cause damage. 1. Raise the unit levelly at least 406 to 508 mm (16 to 20 in) to access the caster . 2. Remove the two Phillips head screws securing the old caster to the cooling unit.
InRoom SC 60 Hz User Manual 22 T roubleshooting Problem Solution Unit does not run T ripped overcurrent protector: Reset the overcurrent protector . If you are attempting to run the coolin g unit from the remote control, check that the batteries in the remote control are good.
23 InRoom SC 60 H z User Ma nual S p are Part s List Part Number Description 0J-0H-0307 Ceiling exhaust ki t 0J-0H-0308 Exhaust duct kit 0J-870-16521 Swivel caster 0J-876-0318 Air filter.
InRoom SC 60 Hz User Manual 24 S pecifications Model APCSC2000 APCSC3500 Net weight (Equipment only) 31 Kg (68 lb) 33 Kg (73 lb) Shipping weight 37 kg (82 lb) 42 kg (92 lb) Dimensions 840 x 685 x 370 mm (33.07 H x 14.57 D x 17.72 W in ) V oltage/Frequency 120V AC - 60 Hz 120V AC - 6 0 Hz Power input 1 170 W 1560 W Operating cu rre nt 9.
.
10/2010 990-3862A-00 1 APC W orldwide Customer Support Customer support for this or any other APC product is available at no char ge in any of the following ways: • V isit the APC W eb site to acce ss documents in the APC Knowledg e Base and to submit customer support requests.
Ein wichtiger Punkt beim Kauf des Geräts APC ACPSC3500 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie APC ACPSC3500 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für APC ACPSC3500 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von APC ACPSC3500 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über APC ACPSC3500 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon APC ACPSC3500 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von APC ACPSC3500 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit APC ACPSC3500. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei APC ACPSC3500 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.