Benutzeranleitung / Produktwartung 900 des Produzenten APC
Zur Seite of 44
Smart-UPS ® Models 900, 1250 and 2000 User's User's User's User's User's Manual Manual Manual Manual Manual TM.
Important safety instructions! Please r ead this manual! V euillez lir e ce manuel! Bitte lesen Sie dieses Anleitungshandbuch! ¡Se ruega leer este manual de instrucciones! This manual provides safety, installation and operating instructions that will help you derive the fullest performance and service life that the UPS has to offer.
Page 1 T able of contents 1. 0 Intr oduction ...................................................................... 2 2. 0 Safety! .............................................................................. 4 Sécurité! (Français) ...............
Page 2 1.0 Intr oduction 1.1 Over view This equipment is a high performance line interactive uninterr uptible power source (UPS) designed to provide clean, r eliable AC power to computer loads.
Page 3 1.0 Intr oduction 1.2 SmartBoost SmartBoost allows continuous on-line operation during extended brownouts or low line voltage conditions. The UPS compensates for the r educed line voltage by boosting the load voltage to a value 12% above the input.
Page 4 2.0 Safety ! Caution! CAUTION ! ■ T o r educe the risk of electric shock, disconnect the Uninterr uptible Power Source from the mains before installing computer interface signal cable (when used). Reconnect the power cord only after all signalling inter connections have been made.
Page 5 2.0 Sécurité ! Attention! A TTENTION! ■ Pour réduir e le risque d’électrocution, débranchez la prise principale de la sour ce d’alimentation permanente (Uninterr uptible Power Source), avant d’installer le câble d’interface allant à l’ordinateur (si utilisé).
Page 6 2.0 Sicherheit ! V orsicht! VORSICHT! ■ Um die Gefahr eines elektrischen Schlages auf ein Minimum zu r eduzier en, die unterbrechungsfr eie Stromversor gung vom Str omnetz trennen, bevor ggf. ein Com- puter -Schnittstellensignalkabel angeschlossen wir d.
Page 7 ESP AÑOL 2.0 ¡ Seguridad ! ¡Atencion! ¡ATENCION! ■ Para r educir el riesgo de descarga eléctrica, desconecte de la r ed la Fuente de energía ininterrumpible antes de instalar el cable de señalización de interfaz de la computadora (si se usa).
Page 8 3.0 Pr esentation 3.1 900V A and 1250V A models - 100, 120 V ac versions Rear view Fr ont view Site wiring fault light See section 4.6 . UPS enable switch See section 4.4 . Circuit breaker NEMA 5-15R receptacles On / Test / Alarm disable pushbutton See section 5.
Page 9 3.0 Pr esentation 3.2 900V A and 1250V A models - 220/230/240 V ac version Rear view Fr ont view On / Test / Alarm disable pushbutton See section 5.1 . Display features See section 5.0 . Power standby pushbutton See section 5.1 . IEC 320 output couplers All couplers are protected by the UPS.
Page 10 3.0 Pr esentation 3.3 2000V A model - 100, 120 V ac versions Fr ont view Rear view Power standby pushbutton See section 5.1 . On / Test / Alarm disable pushbutton See section 5.1 . Battery pack Electronics enclosure 15Amp circuit breaker protects center receptacles NEMA 5-15R receptacles Battery pack cables Display features See section 5.
Page 11 3.0 Pr esentation 3.4 2000V A model - 120 V ac versions options The -1, -2 and -4 wiring device options for the 120 V ac version 2000V A model UPS are shown below for r efer ence. These options allow simple plug-in installation of the UPS where special service or load wiring devices ar e used.
Page 12 3.0 Pr esentation 3.5 2000V A model - 208 V ac version and options The standar d 208 V ac version 2000V A model UPS and its wiring device options are shown below for r efer ence. These options allow simple plug-in installation of the UPS where special service or load wiring devices ar e used.
Page 13 3.0 Pr esentation 3.6 2000V A model - 220/230/240 V ac version Power standby pushbutton See section 5.1 . Battery pack Electronics enclosure Battery pack cables Rear view Fr ont view On / Test / Alarm disable pushbutton See section 5.1 . IEC 320 output couplers All couplers are protected by the UPS.
Page 14 4.0 Installation 4.1 Receiving inspection Once the UPS has been r emoved from its shipping container , it should be inspected for damage that may have occurr ed while in transit. Immediately notify the carrier and place of pur chase if any damage is found.
Page 15 4.0 Installation 4.3 Connect battery pack - 2000V A model only Follow the instructions listed below to install and lock the battery pack coupler . Note: Use only factory supplied or authorized battery packs! 4.3.1 Use a phillips screwdriver to r emove the battery coupler clamp from the electronics enclosur e.
Page 16 4.0 Installation 4.4 Connect UPS to service and enable - continued ■ 220/230/240 V ac versions The 220/230/240 V ac version UPS is not furnished with an input line cord. Instead, two output cor ds are supplied. However , in most installations it will not be necessary to purchase a UPS input power cord.
Page 17 4.0 Installation 4.5 Plug loads into UPS Plug all loads to be protected into the UPS. Do not exceed the UPS's capacity as given in section 9.0 . Once switched on, the UPS will monitor and display the magnitude of the applied load. Note: Do not plug laser printers into this UPS.
Page 18 5.0 Operation 5.1 Display featur es 5.1.1 On / T est / Alarm disable pushbutton The On / T est / Alarm disable pushbutton is used to contr ol activation of the UPS and to energize the load. Once the UPS is ener gized, pressing the button will initiate a battery test.
Page 19 5.0 Operation 5.2 Battery capacity bar graph The battery capacity bar graph continuously displays the state of battery charge. In the above example, the display shows that 100% of rated battery capacity is available. Wher e power quality is fair , the UPS will be able to maintain the battery at 100% of rated capacity .
Page 20 5.0 Operation 5.4 Line voltage bar graph The line voltage bar graph displays the UPS's input voltage in discr ete steps. Line voltage is displayed when the I/T es t pushbutton is pr essed and held.
Page 21 5.0 Operation Note: Option switches may be thrown at any time and take effect immediately . 5.5.3 Replace battery In the event the UPS's battery fails a battery test, the UPS will emit "chirps" for a period of 1 minute.
Page 22 5.0 Operation 5.6 Option switches - continued 5.6.2 Option switch 2 Option switch 2 controls differ ent functions depending upon the UPS version type.
Page 23 5.0 Operation 5.7 Extended capabilities The following sections briefly describe the UPS’s extended capabilities. These ad- vanced functions are accessed by a computer running optional PowerDoctor or PowerChute plus UPS monitoring softwar e.
Page 24 5.0 Operation 5.7 Extended capabilities - continued ● Output voltage, internal temperature, battery voltage, battery capacity - The UPS continuously monitors the rms output voltage, internal temperatur e in degr ees Celsius, battery voltage, and the r emaining battery capacity as a per centage of the fully char ged condition.
Page 25 5.0 Operation 5.7 Extended capabilities - continued ● On-battery output voltage (220/230/240 V ac versions only) - The UPS’s on-battery output voltage may be set to a nominal 220, 225, 230 or 240 V ac. The UPS’s default setting is 225 V ac.
Page 26 6.0 UPS Monitoring 6.1 Over view A UPS system alone provides excellent protection fr om brief power problems. How- ever , during an extended power outage an unattended computer system will eventually shut down due to battery capacity exhaustion.
Page 27 6.0 UPS Monitoring 6.4 Computer interface port The computer interface port is diagramed below for your r eference. Those with technical abilities wishing to use this port in a special application should be awar e of the following limitations and capabilities of the interface.
Page 28 7.0 Difficulty Caution ! CAUTION ! ■ This Uninterruptible Power Source contains potentially hazar dous voltages. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Repairs are performed only by factory trained service personnel.
Page 29 FRANÇAIS 7.0 Difficulté Attention ! A TTENTION! ■ Cette sour ce d’alimentation permanente (UPS) contient des circuits haute tension présentant un danger . Ne jamais essayer de le démonter . Il n’y a aucun composant qui puisse êtr e réparé par l’utilisateur .
Page 30 DEUTSCH 7.0 Schwierigkeit V orsicht ! VORSICHT! ■ Im Inner en dieser unterbr echungsfr eien Stromversor gung herrschen potentiell gefährliche Spannungen. Nicht versuchen, das Gerät zu öf fnen. Es enthält keine vom Benutzer reparierbar en T eile.
Page 31 ESP AÑOL 7.0 Dificultad ¡Cuidado! ¡CUIDADO! ■ Esta Fuente de ener gía ininterrumpible contiene niveles de voltaje peligr osos en potencia.
Page 32 7.0 Difficulty 7.1 T roubleshooting chart PR OB LEM POSSIBLE CA USE ACTIO N TO TA K E U PS will not tu rn on . 1 . U PS Enab le s wi t c h is i n t he of f p os i t i on o r f r ont pan el s wi tc h not pr e s sed. 1 . T ur n o n t he r e ar pa nel U PS En abl e s wi t c h.
Page 33 7.0 Difficulty 7.2 Battery r eplacement check Y ou can expect to r eceive 3 to 6 years of service life fr om the UPS's batteries when installed in a cool, dry location. Battery life is shortened when operated in an envir onment where the ambient temperatur e is normally above 30 ° C (86 ° F).
Page 34 7.0 Difficulty 7.3 Obtaining Service The troubleshooting chart in section 7.1 covers most of the difficulties that a user may encounter under conditions other than a failur e of the UPS itself. For problems not cover ed in the chart, the procedur es outlined below should be followed.
Page 35 8.0 Storing the UPS 8.1 Storage conditions The UPS should be covered and stor ed upright in a cool dry location. The UPS should be stored with its battery in a fully char ged state. That is, the indicated battery capacity should be 100% befor e the UPS is switched off for storage.
Page 36 9.0 Specifications Note: Wher e specifications ratings differ , values for the 100 V ac version are given in { } brackets, values for 208 V ac versions ar e given in ( ) brackets, and values for 220/230/240 V ac versions ar e given in [ ] brackets.
Page 37 9.0 Specifications 9.4 Noise and sur ge suppr ession Surge energy rating (one time, 10/1000 µs waveform) : {160 J}, 480 J, (480 J), [480 J]. Surge current capability (one time, 8/20 µs waveform) : 6500 Amp peak maximum. Surge response time: 0 ns (instantaneous) normal mode, <5 ns common mode.
Page 38 9.0 Specifications 9.9 T ypical r un time versus load Note: Run times are typical at 25°C (77°F). Load 900VA mod el 1 250VA mo d el 200 0VA mo d e l Typ i cal comp u ter l oad (0.
Page 39 Notes.
Page 40 DECLARA TION OF CONFORMITY Application of Council Directive(s): 89/336/EEC Standard(s) to which Conformity is Declared: EN55022, EN50082-1 Manufacturer's Name: AMERICAN POWER CONVERSION M.
Limited W arranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products.
990-7001-A-8 10/93 ( PHONE PHONE PHONE PHONE PHONE (+33) 1.64.62.59.00 in Eur (+33) 1.64.62.59.00 in Eur (+33) 1.64.62.59.00 in Eur (+33) 1.64.62.59.00 in Eur (+33) 1.
Ein wichtiger Punkt beim Kauf des Geräts APC 900 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie APC 900 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für APC 900 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von APC 900 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über APC 900 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon APC 900 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von APC 900 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit APC 900. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei APC 900 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.