OXYGEN SA TURA TION MONITOR PULSOX -300 ® -300 ® -300 Instruction Manual Th is in str um ent mu st be us ed ac cor di ng to th e i nst ru cti ons o f t he do cto r .
Safety Symbols W arnings and precautions noted in this manual and the instrument are indicated by the following markings, designed to prevent accidents caused by erroneous handling of the equipment. This indicates text consisting of a warning or precaution relating to safety .
1 Foreword S a f e t y P r e c a u t i o n s T o ensure correct use of this instrument, read th e following points carefully and adhere to them. After you have read this manual, keep it in a safe place where it can be referred to anytime a question arises.
2 Foreword CAUTION (Failure to adhere to the following points may result in injury or damage to the in- strument or other property .) strument or other property .
3 Foreword Contents Safety Symbols Safety Precautions ............................................................. 1 Foreword ............................................................................ 4 Safety Notes ................................
4 Foreword Foreword Safety Notes CAUTION: Federal law restricts this device to sale by or on the order of a physician. The instrument is designed for measurement of the oxygen saturation (SpO 2 ) of arterial blood and the pulse rate. Do not use it for any other purposes, such as warning warning of sleep apnea and breathing abnormalities.
5 Foreword Package Contents Before using the instrument, make sure that the following items are present. 1) PULSOX-300 main body × 1 2) Wristband WB-300 × 1 3) AAA-size alkaline battery × 1 4) Instruction manuals • PULSOX-300 instruction manual × 1 • Separate manual (Using manual for Probes) × 1 ✻ The probe is optional.
6 Foreword System Diagrams and Accessories T he i ns t ru me nt co ns is t s of t h e fo ll o wi ng i t em s. Optional accessories Standard accessories Wristband WB-300.
7 Foreword Names of Parts PULSOX-300 Power button Probe connector Wristband Battery co ver Used to start/end measurement. Measurement results and messages are displayed. Connect the probe to this connector . U se d t o s et t he in s tr um e nt o n yo u r w ri s t.
8 Foreword Notes on Use • This instrument should be used under the following operat- ing conditions. • T emperature of 0 to 40°C (32 to 104°F), relative humidity of 30 to 85%, with no condensation. • Atmospheric pressure of 700 to 1060 hPa (altitude of – 400 to 3000m).
9 Foreword Difference from the SaO 2 value to displayed value <T able 1> <T able 2> Sa O 2 HbCO Sa O 2 Methemoglobin 1% 5% 10% 1% 5% 10% 50 50 70 70 90 90 100 100 Measured value is alway s lower than the actual value. Displayed value is sometimes higher than the actual value if Sa O 2 is around 50%.
10 Foreword Notes on Storage • This instrument should be stored under the following storage conditions. • T emperature of – 10 to 60°C (14 to 140°F), relative humid- ity of 10 to 95%, with no condensation. • Atmospheric pressure of 700 to 1060 hPa (altitude of – 400 to 3000m).
1 1 Foreword Disposal Method • When disposing of the used battery , insulate the polarity ter- minals with insulating tape etc. If the terminals of the battery come into contact with metal objects, heat generation, explo- sion or fi re may result.
12 Pre parati ons Preparations Before starting measurements using thi s instrument , follow the pro cedure give n bel ow to ensur e that meas ureme nts ar e sta ble. 1) Attaching the Wrist Band Attach the W rist Band WB-300 (supplied as a standard accessory) to the instrument.
13 Pre parati ons 4 Pass th e other end of the band outward through band fi xture B. ◆ T ake care not to twist the band. the band. 2) Connecting the probe Connect the pr obeʼs connector plug into the Probe Connector on the instrument. ◆ Make sure that probeʼs connector plug is oriented correctly .
14 Pre parati ons 3) Installing the battery Procedure 1 Turn the battery cover clockwise approximately 90 degrees to open the cover . ◆ When turning the cover , keep the flat part of your finger on the coverʼs catch. This facilitates opening the cover with minimum force.
15 M e a s u r em e n t Measurement 1) Starting the Measurement 1 A t t a c h t h e p r o b e t o a fi nger of an adult patient. 2 Press the Power button. ● The Power is ON, all the elements on the display are displayed for about 2 seconds, and then the display changes to the measurement display .
16 M e a s u r em e n t 2) Reading the display When the instrument is turned ON, all the elements of the LED will light up. The pulse level, pulse rate and SpO The pulse level, pulse rate and SpO 2 2 value are displayed value are displayed during measurement.
17 M e a s u r em e n t 3) Ending the Measurement About Auto Power-Off function The instrument has an auto power-off function that operates independently .
18 C he ck P o i nt s T rouble Shootings Error Messages The instrument display error messages when the error occurs. Check and correspond to them correctly .
19 C he ck P o i nt s .
20 C he ck P o i nt s .
21 C he ck P o i nt s .
22 C he ck P o i nt s Maintenance and Inspection • Before using the inst rument, make sure that the re is no dam- ag e t o th e i nst rum ent , no d ama ge or wi re- bre aka ge in t he probe cable a nd the instrument op erates correctly and sa fely .
23 Appendix Specifi cation ■ Dual-wavelength pulse type (665nm/880nm) arterial blood oxygen satura- tion measuring instrument • Name: Oxygen Saturation Monitor • Model name: PULSOX-300 ■ Functions: • Measuring range: SpO 2 : 0 to 100% SpO 2 Pulse rate: 30 to 230 bpm • Accuracy: SpO 2 : ±2% SpO 2 (70 to 100% range, 1S.
24 Appendix Probes (SR-5C, SP-5C, LM-5C, SD-5C) Probes (SR-5C, SP-5C, LM-5C, SD-5C) ■ LED-SPD probe ■ T ype • Finger Clip Probe SR-5C • Spot Check Probe SP-5C • Monitor Probe LM-5C • Monit.
25 Appendix Appendix Calculation Method for Displayed V alues <Pulse level meter> The pulse level meter displays the transmitted light amount ratio calculated by the following equation. The pulse level is indicated in eight levels (0 to 15%, full scale if over 10%).
26 Appendix EMC Guidance Guidance and manufactures declaration - electromagnetic emissions Guidance and manufactures declaration - electromagnetic immunity The Oxygen Saturation Monitor Model PULSO X-300 is intended for use in the electromagnetic environment specified below.
27 Appendix Guidance and manufactures declaration - electromagnetic immunity The Oxygen Saturation Monitor Model PULSO X-300 is intended for use in the electromagnetic environment specified below. The customer or the user of the Model PULSO X-300 should assure that it is used in such anenvironment.
28 Appendix ■ Spectral Absorption of Hb and HbO 2 Absorption coefficient Wavelength Red light Infrared light Measurement Principle This instrumen t measures the oxygen satur ation (SpO 2 ) in arte- rial blood and pulse rate continuously in a non-invasive method by applying optical principles.
29 Appendix R e l a t i o n b e t w e e n O x y g e n S a t u r a t i o n a n d P a r t i a l P r e s s u r e The relation between oxygen saturation (SpO 2 ) and oxygen partial pressure (PaO 2 ) is shown in the graph below . SpO 2 is the oxygen saturation as measured by pulse oximeters.
AGGAKK ( AGGAKK ( AGGAKK 1 ) Printed in Japan 92 22-1 732 -25 © 2005-2006 KONICA MINOL T A SENSING, INC. Manufacturer 3 -9 1, D a is en -n i sh im ac h i, S ak a i- ku , S ak ai -s h i, O sa k a 59 0.
Ein wichtiger Punkt beim Kauf des Geräts Konica Minolta 300 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Konica Minolta 300 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Konica Minolta 300 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Konica Minolta 300 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Konica Minolta 300 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Konica Minolta 300 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Konica Minolta 300 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Konica Minolta 300. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Konica Minolta 300 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.