Benutzeranleitung / Produktwartung ULTRAFILTER 300 625.384720 des Produzenten Kenmore
Zur Seite of 20
OWNER'S MANUAL MODEL NO. UltraFilter 300 625.384720 UltraFilter 500 625.384750 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or maintaining your reverse osmosis system, call this toll-free number.
- WARRANTY- _ t t t t t t t t t t t t t t t t t t t t t t t t t t t t t _ FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM I I I (except filter cartridges and R.
- TABLE OF CONTENTS - Where To Install the RO System ........ 4 Tools and Materials Needed ........... 4 Installation Steps .................... 5- 9 Cold Water Supply .................. 5 Drain Adapter ..................... 6 Faucet .................
- WHERE TO INSTALL THE RO SYSTEM - The RO assembly and storage tank is designed for installation under the sink, usually in the kitchen or bathroom. The RO assembly mounts on a wall sur- face, or can lay on the cabinet floor next to the storage tank. Hanger washers and wood screws are included for cabinet wall mounting.
- STEP 1: INSTALL COLD WATER SUPPLY FITTING - Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The fitting must provide a leak-tight connection to the RO 1/4" tubing (see FIG. 8, page 8). A typical connection using the included water supply fitting is shown in FIG.
- STEP 2: INSTALL DRAIN ADAPTER - • Note: Running the drain tubing directly to a floor drain, sump, standpipe, laundry tub, etc., as shown on page 17, is preferred. However, if that is not pos- sible or practical, the included drain adapter installs in the sink drain pipe, always above or ahead of the p-trap (FIG.
- STEP 3: INSTALL FAUCET (cont.)- ..* SEM.LEF*UCET [ FIG. 6 ] 1. Remove the large blue nut from the faucet threads. 2. Slide the three attached tubes and the telephone style wire (monitored models only) through the sink or countertop hole, aligning gasket under faucet base.
- STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS - 1. CONNECT DRAIN TUBING, FAUCET TO DRAIN ADAPTER: Referring to FIG. 8, run the loose section of black 3/8" tubing from the faucet to the drain adapter, with a black collet, installed on page 6.
- STEP 6: SANITIZING, PRESSURE TESTING & PURGING - SANITIZING Sanitizing is recommended upon installation of the RO system, and after servicing inner parts. It is im- portant for the service person to have clean hands while handling inner parts of the system.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - PREFILTER Water from the cold supply pipe enters the RO as- sembly prefilter first (FIG. 8, page 8, and schematic, page 11). The prefilter has a replaceable sediment cartridge with activated carbon in its composition.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - REVERSE OSMOSIS WATER FLOW SCHEMATIC ! PRODUGq- WATER FAUCET _ir 9_p Y gra_viLy drain ! WATER IN 11 Problems, Questions? Call 1-800-426-9345 Kenmore Water Lin.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - To keep your reverse osmosis system operating and producing higil quality" water, you must make sure supply water is Nways within the lhnits shown in the specifications. Good supply water helps to assure longer Fife from the RO membrane cartridge, prefilter and postfilter cartridges.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - 2. Remove (turn to the left) the sump from the filter head, Be careful...the sump is full of water, 3. Remove mid disc_d the RO c_tridge in a proper manner. Ftush the hlsides of the sump with fresh wa- ter. Do not lose the large o-ring seals.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - TUBING CONNECTION (continued) AUTOMATIC SHUTOFF SERVICE To Disconnect Tubing: Push the collet inward and hold with a finger while pulling the tubing out. FIG. 11-A] cut tubing _uare L 1 I I I end of tubing round and smooth, with no cutS, nicks or flat spots Tubing correctly cut and connected oollet _.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - REVERSE OSMOSIS SYSTEM CARE GUIDE MODEL NOs. 625.384720 & 625.384750 1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges or when yellow LED flashes.
- DIMENSIONS and SPECIFICATIONS - 15 _ 13" Supply water pressure limits ........................ 40 - 100 psi Supply water temperature limits ..................... 40 - 100 "F Maximum total dissolved soiids (TDS) ............... 2000 ppm Maximum water hardness @ 6.
- REMOTE LOCATION FOR REVERSE OSMOSIS SYSTEM - REMOTE RO INSTALLATION (storage tank not shown) Possible remote locations for the RO nearby the kitchen or bathroom sink include; (1) a basement area underneath the sink, and (2) an adjacent room or closet.
- REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Model Nos. 625.384720 & 625.384750 23 9 _ 8 24 / M_ni[old Housing PUSH - IN FITTINGS (_) 114" e_318 20 Z Q) DRAIN 19 22 x r I .
- REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Key Part Description of Part No. Number 1 7221128 Sump (3 req.) 2 7223633 O-Ring, 2-1/4" x 2-1/2" (3 req.) 3 9006062 Screw (2 req.) 4 9041700 Hanger Washer (2 req.) 5 7234210 Paddtewheel & O-Ring Kit, 625.
OWNER'S MANUAL MODEL NO. UltraFilter 300 625.384720 UltraFilter 500 625.384750 The model number of your reverse osmosis system is found on the rating decal.
Ein wichtiger Punkt beim Kauf des Geräts Kenmore ULTRAFILTER 300 625.384720 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Kenmore ULTRAFILTER 300 625.384720 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Kenmore ULTRAFILTER 300 625.384720 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Kenmore ULTRAFILTER 300 625.384720 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Kenmore ULTRAFILTER 300 625.384720 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Kenmore ULTRAFILTER 300 625.384720 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Kenmore ULTRAFILTER 300 625.384720 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Kenmore ULTRAFILTER 300 625.384720. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Kenmore ULTRAFILTER 300 625.384720 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.