Hardware Reference Guide NetLinx Integrated Controllers NXI-x000 Series NetLinx Integrated Controllers (NI-2000, NI-3000, NI-4000) Last Revised: 5/30/2008.
AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material and workmanship under n ormal use for three (3) years from the date of purchase fr om AMX, with the foll.
Table of Contents i NI-2000, NI-3000, NI-4000 Hardware Reference Guid e Table of Contents Introduction .................. ...................................................................... ................ 1 NI-2000 Specifications ................
ii NI-2000, NI-3000, NI-4000 Hardware Refe rence Guide Table of Contents Input/Output (I/O) Por t: Connections and Wir ing ......... ......................... ................. 29 IR/Serial Port: Connections and Wiring ..................... ..........
Introduction 1 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide Introduction NetLinx Integrated Master Controllers can b e programmed to control RS-232/422/485, Relay , IR/Serial, and Input/Output devices through the us e of both the NetLinx programming la nguage and the NetLinx Studio application (version 2.
Introduction 2 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide NI-2000 Specifications The front panel LEDs (FIG. 1) are grouped by control type and are labeled according to their corresponding port (connector) numbers on the rear of the unit. The back of the unit contains three RS-232/422/485, one Relay , one IR/Serial and one I/O connectors.
Introduction 3 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide NI-2000 Specifications Dimensions (HWD): • 3.47" x 17.00" x 3. 47" (8.81 cm x 43.18 cm x 8.82 cm) • 2 RU (rack unit) high Power Requirement: • 700 mA @ 12 VDC Memory: • 32 MB SDRAM • 1 MB of Non-volatile Flash Compact Flash: • 32 MB Card (upgradeable).
Introduction 4 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide NI-2000 Specifications (Cont.) Rear P anel Connectors (Cont.): Relay (P or t 4) • Four-channel single-pole single-throw relay po rts • Each relay is independently controlled.
Introduction 5 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide NI-2000 Specifications (Cont.) Rear P anel Connectors (Cont.): Ethernet Link/Activity LED • LEDs show communication activity , conn.
Introduction 6 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide NI-3000 Specifications The front LEDs (FIG. 3) are grouped by control type and are labeled according to their corresponding port (connector) numbers on the rear of the unit. Th e back of the this unit contains RS-232/422/485, Relay , IR/Serial and I/O connectors.
Introduction 7 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide NI-3000 Specifications Dimensions (HWD): • 3.47" x 17.00" x 3. 47" (8.81 cm x 43.18 cm x 8.82 cm) • 2 RU (rack unit) high Power Requirement: • 900 mA @ 12 VDC Memory: • 32 MB SDRAM • 1 MB of Non-volatile Flash Compact Flash: • 32 MB Card (upgradeable).
Introduction 8 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide NI-3000 Specifications (Cont.) Rear P anel Connectors (Cont.): Relay (P or t 8) • Eight-channel single-pole single-throw r elay ports • Each relay is independently controlled.
Introduction 9 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide NI-3000 Specifications (Cont.) Rear P anel Connectors (Cont.): Ethernet Link/Activity LED • LEDs show communication activity , conn.
Introduction 10 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide NI-4000 Specifications The front LEDs (FIG. 5) are grouped by control type, and are labeled according to their corresponding port (connector) numbers on the rear of the unit. Th e back of the this unit contains RS-232/422/485, Relay , IR/Serial and I/O connectors.
Introduction 11 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide NI-4000 Specifications Dimensions (HWD): • 5.21" x 17.00" x 9.60" (13.
Introduction 12 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide NI-4000 Specifications (Cont.) Rear P anel Connectors: RS-232/422/485 (P or ts 1 -7) • Seven RS-232/422/485 control ports using DB9 (male) connectors w ith XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and 300-1 15,200 baud.
Introduction 13 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide NI-4000 Specifications (Cont.) Rear P anel Connectors (Cont.): Program port • RS-232 DB9 connector (male) can b e connected to a D.
Introduction 14 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide Related Documents For information on using the on-board W eb Console, as well as NetLinx send commands and terminal communications to configure the NI Controllers, refer to the NetLinx Inte grated Contr oller W ebConsole & Pr ogr amming Guide .
Installation and Upgrading 15 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide Installation and Upgrading Installing NetLinx Control Cards (NI-4000 Only) NetLinx Cards can be installed into the front card slots. The cards mo unt horizontally through the card slot openings on the front of the enclosure.
Installation and Upgrading 16 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide Setting the NetLinx Control Card Addresses (NI-4000 Only) The 8-position CardFrame Number DIP switch (lo cated on the re ar of the NI-4000) sets the starting address (the device number in the D:P:S specification) for the Control Cards installed in the CardFrame.
Installation and Upgrading 17 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide NUMBER:PORT:SYSTEM where: Removing NetLinx Control Cards (NI-4000 Only) T o install NetLinx Control Card: 1. Discharge an y static electricity from your body , by touching a grounded object and unplug all connectors (if any) from the unit.
Installation and Upgrading 18 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide 3. Carefully pull-up and remove the housing up and away from the Controller to expose the internal circuit board (FIG. 3). 4. Refer to the following Installation of Compact Flash Upgr ades for detailed replacement information.
Installation and Upgrading 19 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide 7. T o complete the upgrade process, close and re-sec ure the Integrated Controller enclosure using the procedures outlined in the following section. Closing and Securing the Ou ter Housing Once the card has been replaced, close and re-secure the outer housing: 1.
Installation and Upgrading 20 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide 3. Thread the cables through the opening in the equipment ra ck. Allow for enough slack in the cables to accommodate for mov ement during the installation process. 4. Reconnect all cables to their appropriate source/terminal locations.
Connections and Wiring 21 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide Connections and Wiring Setting the Configuration DIP Sw itch (for the Program Port) Prior to installing the Controller , use the Conf igur ation DIP switch to set the baud rate used by the Program port for communication.
Connections and Wiring 22 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide Working With the Co nfiguration DIP Switch 1. Disconnect the power supply from the 2-pin PWR (green) connector on the rear of the NetLinx Integrated Controller .
Connections and Wiring 23 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide Modes and Front Panel LED Blink Patterns The following table lists the modes and blink patterns for the front panel LEDs assoc iated with each mode. These patterns are not e vident until after the unit is po wered.
Connections and Wiring 24 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide AXlink Port and LED All NI units ha ve an AXlink port and adjacent status LED (FIG. 1). This port allo ws the NI to support AMX Legac y AXlink devices such as G3 touch panels ( ex: CP4/A ) and PosiT rack Pilot devices.
Connections and Wiring 25 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide Preparing Captive Wires Y ou will need a wire stripper and flat-blade screwdri ver to prepare and connect the captiv e wires. 1. Strip 0.25 inch (6.35 mm) of insulation off all wires.
Connections and Wiring 26 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide Using the 4-pin Mini-Phoe nix Connec tor For Data With External Power T o use the 4-pin 3.
Connections and Wiring 27 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide The table below provides information about the connector pins, signal types, and signal functions.
Connections and Wiring 28 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide ICSHub OUT Port: Connections and Wiring The NI Controller must be equipped with the av aila ble ICSNet connectors for this functionality to be activ e.
Connections and Wiring 29 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide Input/Output (I/O) Port: Connections and Wiring The I/O port responds to either switch closures, voltage level (high/lo w) changes, or it can be used for logic-le vel outputs.
Connections and Wiring 30 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide IR/Serial Port: Connections and Wiring Y ou can connect up to eight IR- or Serial-controllable devices to the IR/Serial connectors on the rear of the NI-4000 and NI-3000 and up to fou r on the NI-2000 (FIG.
Connections and Wiring 31 NI-2000, NI-3000, NI-4000 Hardware Reference Gu ide Ethernet/RJ-45 Port: Connections and Wiring The following table lists the pinouts, signals, and pairing for the Ethernet connector . FIG. 10 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable.
Connections and Wiring 32 NI-2000, NI-3000, NI-4000 Hardware Refer ence Guide Ethernet Ports Used By th e Integrated Contr oller Ethernet Port Descriptions Port type Description Standard Por t # FTP The on-board Master has a built-in FTP server .
Connections and Wiring 33 NI-2000, NI-3000, NI-4000 Hardware Reference Guide.
5/08 © 2008 AMX. All rights reserved. AMX and the AM X logo are register ed trademarks of AMX. AMX reserves the ri ght to alter specifica tions without notice at any time. It’s Your World - Take Con trol™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.
Ein wichtiger Punkt beim Kauf des Geräts AMX NetLinx Integrated Controllers NXI-x000 Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie AMX NetLinx Integrated Controllers NXI-x000 Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für AMX NetLinx Integrated Controllers NXI-x000 Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von AMX NetLinx Integrated Controllers NXI-x000 Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über AMX NetLinx Integrated Controllers NXI-x000 Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon AMX NetLinx Integrated Controllers NXI-x000 Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von AMX NetLinx Integrated Controllers NXI-x000 Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit AMX NetLinx Integrated Controllers NXI-x000 Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei AMX NetLinx Integrated Controllers NXI-x000 Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.