Benutzeranleitung / Produktwartung NetLinx Custom Panel Interface NXP-CPI16 des Produzenten AMX
Zur Seite of 18
Operation/Reference Guide Custom Panel I nterfaces NXP-CPI16 NetLinx Custom Panel Interface Last Rev ised: 1/13/ 2009.
AMX Limited Warr anty and Disclaimer AMX warrant s it s pro ducts to be free of defect s in materia l and wor kmanshi p under n ormal use for three (3) years from the date of purc hase from AMX, with .
Table of Contents i NXP-CPI16 NetLinx Custom Panel Interface Table of Contents Product I nformation ....... .......... ..... ....... ......... ..... ........ ......... ..... ....... .......... ..... .... 1 Specifications ... ..........................
.
Produc t Info rma tion 1 NXP-CPI16 NetLinx Custom Panel Interfa ce Product Information The AMX NXP-CPI16 is a NetLinx panel device that allows sys tem integrators to connect switches, indicators, and rotary encoders to a NetLinx control system.
2 NXP-CPI16 NetLinx Custom Panel Interfa c e Specifications The table below lists the NXP-CPI1 6 specifications. NXP-CPI16 Specifications Power Requirement 12 VDC (300 m A ma x.
3 NXP-CPI16 NetLinx Custom Panel Interfa ce Input and Output Conne ctors T o install the NXP-CPI16, connect r ibbon cables or a PC b oard to one or more of the h eaders. The table belo w shows the pinouts for the two 20-pin headers. Quadrature Connectors The table below lists th e connector pinouts for the quadrature connector .
4 NXP-CPI16 NetLinx Custom Panel Interfa c e Quad ratur e Input s By default, the quadrature inputs e xpect the phase relationship, shown in FIG. 2, for a clockwise rotation of the encoder to generate a positiv e level change. If the phase relationship does not match the e xample, a clockwise rotation will generate a negati ve lev e l change.
Progra mming 5 NXP-CPI16 NetLinx Custom Panel Interfa ce Programming There are two modes of Channel A ssign ments: Discrete Outp ut and Def au lt Mode.
Send_Commands Use the Send_Commands listed in the table belo w to program the NXP-CPI16. Send_Commands BMODE Configures either set of 8 outp uts as an 8-segment bar- graph display .
7 NXP-CPI16 NetLinx Custom Panel Interfa ce Send_Commands (Cont.) LV L _ S Z Sets the size (data type) of the value that will be used by the NXP-CPI16 when receiving and sending LEVEL messages. The default is byte (8-bits), which yields a rang e of 0 - 2 55 for the level value.
8 NXP-CPI16 NetLinx Custom Panel Interfa c e The NXP-CPI16 uses input channels to rep ort user input on the contacts or switches attached to the input terminals. Output channels are used to turn on the lamp or LED display de vice s to indicate the b utton status to the user .
9 NXP-CPI16 NetLinx Custom Panel Interfa ce Each of the two 20-pin connectors is assign ed a group of 8 input and output channels. The table belo w sho ws the relation of input and output channels in the ST A TUS modes. The NXP-CPI16 may be configured to default to ST A TUS- ON mode using the follo wing method.
10 NXP-CPI16 NetLinx Custom Panel Interfa c e.
System Worksheets 11 NXP-CPI16 NetLinx Custom Panel Interfa ce System Worksheets Header 1 Header 2 Dealer ID Date Dealer PO Number Job SO Number Description Serial Number Rev Number Device Number CH1 .
CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 Out In Out In Out In Out In Out In Out In Out In Out In 9 10 11 12 Ground Po w e r Ground Ground 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20.
.
1/09 © 2009 AM X. All right s reserved . AMX and the AMX logo ar e registered trademarks of AMX. A MX reserves t he right to alter spec ific ations without notice at any time. It’s Y ou r W orld - T ak e Co ntr ol™ 3000 RESEARCH DR IVE, RICHARDSON, TX 75082 USA • 800.
Ein wichtiger Punkt beim Kauf des Geräts AMX NetLinx Custom Panel Interface NXP-CPI16 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie AMX NetLinx Custom Panel Interface NXP-CPI16 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für AMX NetLinx Custom Panel Interface NXP-CPI16 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von AMX NetLinx Custom Panel Interface NXP-CPI16 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über AMX NetLinx Custom Panel Interface NXP-CPI16 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon AMX NetLinx Custom Panel Interface NXP-CPI16 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von AMX NetLinx Custom Panel Interface NXP-CPI16 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit AMX NetLinx Custom Panel Interface NXP-CPI16. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei AMX NetLinx Custom Panel Interface NXP-CPI16 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.