Operation/Reference Guide Controllers NXI NetLinx ® Integrated Controller Initial Release: / Last Revised: 1/8/ 2009.
AMX Limited Warranty and Disclaimer AMX Corporation warrants its product s to be free of defec ts in material and workmanship under normal use for three (3) years from the date of purchase from AM X C.
Table of Contents i NXI NetLinx Integrated Controller Table of Contents Product Information ...................... ..................................................................... 1 Front and Rear Panel Components .................... ...........
ii NXI NetLinx Integrated Controller Table of Contents.
Product Information 1 NXI NetLinx Integrated Controller Product Information The NXI NetLinx Inte grated Controlle r represents the ne w generation of AMX multi-port cent ral controllers.
Product Information 2 NXI NetLinx Integrated Controller Specifications NXI Specifications Power requirements 1.09 A @ 12 VDC (NXI only/no card) Memory 64K of IR memory:· • 32K IR memory for IR port.
Product Information 3 NXI NetLinx Integrated Controller NXI Specifications (Cont.) Rear P anel Components: RS-232/422/485 (ports 1-6) Six 10-pin (male) connec tors that support bi-directional RS-232/422/485 communication (XON/XOFF , CTS/RTS, 300-230,400 baud).
Product Information 4 NXI NetLinx Integrated Controller.
Connections and Wiring 5 NXI NetLinx Integrated Cont roller Connections and Wiring Installing the Master or Hub Card The NXC-ME260 NetLinx Master or any Hub Card can be installed in the NXI. The card mounts in a horizontal position, through the master card slot on the rear panel of the NXI enclosure (see FIG.
Connections and Wiring 6 NXI NetLinx Integrated Controller IR/Serial Connections and Wiring Y ou can connect up to eight IR- or serial- controllable de vices to the IR/Serial connec tors (ports 8-15).
Programming 7 NXI NetLinx Integrated Cont roller Programming This section describes the Send_C ommands, Send_Strings, and Channel commands you can use to program the NXI. The e xamples in this se cti on require a declaration in the DEFI NE_DEVICE section of y our program to work correct ly .
Programming 8 NXI NetLinx Integrated Controller Program Port Commands The Program port commands l isted in th e follo wing table can be sent directly to the Master Card using a terminal program (i.
Programming 9 NXI NetLinx Integrated Cont roller Program Port Comma nds (Cont.) PROGRAM INFO Displays the NetLinx program's name residing in the Master Card. PULSE Pulses a channel on a device on and of f. The device can be on any sys- tem the master you are connected to can reach.
Programming 10 NXI NetLinx Integrated Controller ESC Pass Codes There are 'escape' codes in the pass mode. These code s can switch the display mode or exit pass mode. The follow ing 'escape' codes are defined. Program Port Comma nds (Cont.
Programming 11 NXI NetLinx Integrated Cont roller Notes on Specific Telnet/Terminal Clients T elnet and terminal clients will hav e different behaviors in some situations . This section sta tes some of the known anomalies. Windows TM client pro grams Anomalies occur when using a W indo ws client if you are not typing standard ASCII characters (i.
Programming 12 NXI NetLinx Integrated Controller RS-232/422/485 Send_Commands RS-232/422/485 Send_Commands B9MOFF Sets the port's communica- tion parameters for stop and data bits according to the software settings on the RS- 232 port (default). This command works in conjunction with the B9MON co mmand.
Programming 13 NXI NetLinx Integrated Cont roller RS-232/422/485 Send_C ommands (Cont.) SET BAUD Sets the RS-232/422/485 port's communication param- eters.
Programming 14 NXI NetLinx Integrated Controller RS-232/422/485 Send_C ommands (Cont.) RXON S tarts transmitting received characters to the Master Card.
Programming 15 NXI NetLinx Integrated Cont roller RS-232/422/485 Send_String Escape Sequences RS-232/422/485 Send_Stri ng Escape Sequences 27,17, Sends device-s pecific break characters for a specified duration.
Programming 16 NXI NetLinx Integrated Controller IR / Serial Ports (8 - 15) Channels IR/Serial Send_Commands The following IR and IR/Serial Send_Commands ge nerate control signals for external equipment. IR / Serial Ports Channels 00001 - 00229 IR commands.
Programming 17 NXI NetLinx Integrated Cont roller IR/Serial Send_Commands (Cont.) CTOF Sets the duration of off time (no signal) between IR pulses for channel and IR function transmissions. Off time set- tings are stored in non-vola- tile memory . The factory default for channel off time is 5 (.
Programming 18 NXI NetLinx Integrated Controller IR/Serial Send_Commands (Cont.) PON T urns on a device, based on input Link. If at any time the IR sensor reads that the device is off (such as if one turned it off manually at the front panel), the card automatically attempts to turn the device back on.
Programming 19 NXI NetLinx Integrated Cont roller IR/Serial Send_Commands (Cont.) SP Generates a single IR pulse. Y ou can use the CTON to set pulse lengths and CTOF for time off between pulses.
Programming 20 NXI NetLinx Integrated Controller IR/Serial Send_Commands (Cont.) XCHM Changes the IR output pat- tern for the XCH command. Syntax: SEND_COMMAND <DEV>,'XCH-<Mode>' V ariable: Mode = 0-4 Example: SEND_COMMAND IR_1,'XCH 3' Sets the IR_1 device's extended channel command to mode 3.
Programming 21 NXI NetLinx Integrated Cont roller Input/Output Send_Commands The following Send_Com mands prog ram the I/O ports on the NXI. IR/Serial Send_Commands (Cont.
Programming 22 NXI NetLinx Integrated Controller.
Programming 23 Enter the Document Name Here.
1/09 © 2009 AMX. All rights reserved. AMX and the AM X logo are register ed trademarks of AMX. AMX reserves the ri ght to alter specifica tions without notice at any time. It’s Your World - Take Con trol™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.
Ein wichtiger Punkt beim Kauf des Geräts AMX AMX NetLinx Integrated Controller NXI (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie AMX AMX NetLinx Integrated Controller NXI noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für AMX AMX NetLinx Integrated Controller NXI - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von AMX AMX NetLinx Integrated Controller NXI reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über AMX AMX NetLinx Integrated Controller NXI erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon AMX AMX NetLinx Integrated Controller NXI besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von AMX AMX NetLinx Integrated Controller NXI verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit AMX AMX NetLinx Integrated Controller NXI. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei AMX AMX NetLinx Integrated Controller NXI gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.