Benutzeranleitung / Produktwartung Stratford Tf des Produzenten Aarrow Fires
Zur Seite of 36
Aarrow Fires Ltd The Fireworks Bridport Dorset, DT6 3BE Great Britain T el. (44) 01308 427234 Fax. (44) 01308 427441 www .aarrowfires.com Operating & Installation Manual PLEASE RET AIN THESE INSTR.
Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Stratford Family to ensure ultimate performance and years of trouble free enjoyment. Every detail on the fire has been carefully engineered and designed which is why we are so confident in the reliability of our product.
Page INTRODUCTION Safety Notices 5 The Principle of the Fire 5 Check List 6 T echnical Data 7 OPERA TING INSTRUCTIONS Multifuel Grate 8 Airwash Inlet Controls 8 Interlock System 9 Multi Purpose Operat.
W ARNING T O ALL MUL TIFUEL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES ARE "CALCO", "PETROCOKE" OR "WONDERCO" MUST NOT BE BURNED IN THIS APPLIANCE T O USE THESE FUELS WILL INV ALIDA TE THE APPLIANCE GUARANTEE IF IN DOUBT CONT ACT THE SOLID FUEL ASSOCIA TION TELEPHONE NUMBER 0800 600 000 www .
S tratford Tf & T i Multifuel Boiler S toves 5 INTRODUCTION SAFETY A fireguard conforming to BS 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to BS 3248 should be fitted.
6 S tratford Tf & T i Multifuel Boiler S toves CHECK LIST Inside the appliance you should find the following: 1. Fuel retainers 2 2 2 2 Part Description &V isual Aid (not to scale) S tratford Tf 30b S tratford Tf 50b S tratford Tf 70b S tratford Tf 90b 2.
S tratford Tf & T i Multifuel Boiler S toves 7 TECHNICAL DA T A Number of radiators in average installation *1kW = 3420 BTU’ s ** 25.4mm = 1 inch. 3.5 1 1,970 4.5 15,390 TECHNICAL DA T A S tratford Tf 50b S tratford Tf 70b S tratford Tf 90b 7.5 25,000 13 45,000 17.
MUL TIFUEL GRA TE The Aarrow Multifuel grate comprises of a series of reciprocating cast iron bars seated on a pivoted "comb". These should come fitted in your stove, if not please refer to page 16 for fitting and operation and also operating instructions on fuels for correct settings of the grate.
INTERLOCK SYSTEM Stratford Tf and T i Multifuel Boiler Stoves are fitted with an "interlock" system. A situation where the fire door is closed and the ash door is open may lead to serious overfiring which could damage the appliance. Correct use of the doors and interlock system will ensure that this does not happen.
10 S tratford Tf & T i Multifuel Boiler S toves OPERA TING INSTRUCTIONS S tep 4 Remove the glass completely . Store glass- retaining clips and white gasket (if sound) safely for re-use. S tep 5 Follow this procedure in reverse to fit replacement door glass or gasket.
S tratford Tf & T i Multifuel Boiler S toves 11 OPERA TING INSTRUCTIONS FUEL TYPES W ood- Any type of wood is suitable provided it is well seasoned and has a moisture content below 20%.
12 S tratford Tf & T i Multifuel Boiler S toves OPERA TING INSTRUCTIONS ENSURE THA T YOU HA VE READ & UNDERSTOOD THESE INSTRUCTIONS BEFORE LIGHTING THE FIRE. AL W A YS WEAR SUIT ABLE PROTECTIVE FIRE GLOVES WHEN REFUELLING YOUR STOVE. SOLID FUEL BURNING •Set the grate to ‘coal’ position.
S tratford Tf & T i Multifuel Boiler S toves 13 OPERA TING INSTRUCTIONS ASH REMOV AL The ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan. On no account should the ash be allowed to build up to touch the grate as this will greatly shorten its life.
14 S tratford Tf & T i Multifuel Boiler SER VICING MAINTENANCE It is important that your fir e is r egularly serviced in accor dance with these instructions.
S tratford Tf & T i Multifuel Boiler S toves 15 INST ALLA TION GENERAL PRECAUTIONS Note - All inst allations must conform to the appropriate building regulations. The Building Regulations for England and W ales 2000 ref Approved Document J 2002 edition (issued by the DTLR).
MUL TIFUEL GRA TE All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "H" sitting on the high sections of the comb, and the ends marked "L" sitting on the low sections.
S tratford Tf & T i Multifuel Boiler S toves 17 INST ALLA TION FITTING THE FLUE OUTLET AND HOT PLA TE The flue outlet spigot is found inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet).
18 S tratford Tf & T i Multifuel Boiler INST ALLA TION Due to the gradual introduction of European Chimney Standards chimneys will be specified according to their performance designation as defined in BS EN 1443 that covers the General Requirements for chimneys.
S tratford Tf & T i Boiler Multifuel S toves 19 INST ALLA TION INTEGRAL BOILERS Integral boilers should be connected, with flow and return connection of any circuit on opposite sides of the applia.
20 S tratford Tf & T i Boiler Multifuel S toves INST ALLA TION T i MODELS ADDITIONAL INFORMA TION FOR INSET ST OVES (Ti40B) BUILDERS OPENING / CHIMNEY BREAST Stratford T i 40 fires are designed to.
S tratford Tf & T i Multifuel Boiler S toves 21 INST ALLA TION.
22 S tratford Tf & T i Boiler Multifuel S toves INST ALLA TION P LAN V IEW OF REGISTER PLA TE AND CLEARANCES FOR NON INSULA TED FLUES A is minimum clearance for non-insulated flue = 1.
S tratford Tf & T i Boiler Multifuel S toves 23 INST ALLA TION Central Heating and Domestic Hot W ater System Using Four Boiler T appings Central Heating System W ithout Domestic Hot W ater Using Four Boiler T appings Note: Diagrammatic representation only .
24 S tratford Tf & T i Multifuel Boiler S toves INST ALLA TION Central Heating System W ithout Domestic Hot Water Using Three T appings Note: Diagrammatic representation only . Design and calculations for individual systems should always be carried out by a qualified heating engineer .
S tratford Tf & T i Multifuel Boiler S toves 25 BOILER T APPING POSITIONS S tratford Tf30 Boiler T apping Positions S tratford Tf50 Boiler T apping Positions All dimensions in mm.
26 S tratford Tf & T i Multifuel Boiler S toves BOILER T APPING POSITIONS S tratford Tf70 Boiler T appings Positions S tratford Tf90 Boiler T appings Positions All dimensions in mm.
S tratford Tf & T i Multifuel Boiler S toves 27 BOILER T APPING POSITIONS S tratford T i 40 Inset Boiler T apping Positions All dimensions in mm.
W A TER CONNECTIONS Heating systems The size of the heating system which can be run, will depend on the output rating of the appliance. It will be necessary to work out heat loss calculations for the system proposed in order to establish the kW/hr rating.
S tratford Tf & T i Multifuel Boiler S toves 29 INST ALLA TION T emperatur e and Pr essur e Relief V alve W ith solid fuel appliances it is not practicable to provide a sufficiently rapid reaction.
30 S tratford Tf & T i Multifuel Boiler S toves CHECK LIST CHECKLIST Hearths, Fir eplaces, Flues and chimneys This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory , and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002.
S tratford Tf & T i Boiler Multifuel S toves 31 P AR TS LIST 1. Fuel Retainers AFS152 AFS153 AFS153 AFS153 AFS030A AFS031 AFS034 AFS035 AFS001 AFS001 AFS002 AFS003 AFS010 AFS010 AFS012 AFS012 AFS008 AFS008 AFS008 AFS008 AFS050 AFS051 AFS052A AFS1 16 AFS009 AFS009 AFS011 AFS011 2.
32 S tratford Tf & T i Multifuel Boiler S toves P AR TS LIST 8. Airwash AFS1077 AFS1077 AFS1077 AFS1077 AFS088 AFS090 AFS090 AFS090 AFS089 AFS091 AFS091 AFS091 AFS047 AFS047 AFS047 AFS047 AFS048 AFS048 AFS048 AFS048 AFS200 AFS201 AFS0201 AFS201 AFS095 9.
S tratford Tf & T i Multifuel Boiler S toves 33 P AR TS LIST 15. Fire Door Locking Assembly AFS204 AFS204 AFS204 AFS204 AFS020 AFS020 AFS020 AFS020 AFS022 AFS022 AFS022 AFS022 AFS021 AFS021 AFS021 AFS021 AFS007 AFS007 AFS007 AFS007 AFS168A AFS170A AFS0172A AFS172A AFS075A AFS077A AFS082A AFS082A 16.
Guarantee Once again we would like to thank you for buying a Stratford multifuel boiler stove. When you buy an Aarrow Fir e, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want.
Should you have any questions about your Stratford S tove that is not covered in this manual please contact your Aarrow retailer . Please keep all repair receipts safely . Please ensure you have this manual available when an engineer visits as they will complete the service record chart.
BK029 FINAL F ACT OR Y CHECK LIST QUALITY FINISH PA R T S FLUE OUTLET HOT PLA TE FUEL RET AINERS GRA TE BARS FIRE BED SURROUNDS THROA T PLA TE AIR W ASH DOOR CA TCHES INTERLOCK ASH P AN OPERA TING TOOL THERMOST A T OPERA TING INSTRUCTIONS Model.......
Ein wichtiger Punkt beim Kauf des Geräts Aarrow Fires Stratford Tf (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Aarrow Fires Stratford Tf noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Aarrow Fires Stratford Tf - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Aarrow Fires Stratford Tf reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Aarrow Fires Stratford Tf erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Aarrow Fires Stratford Tf besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Aarrow Fires Stratford Tf verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Aarrow Fires Stratford Tf. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Aarrow Fires Stratford Tf gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.