Benutzeranleitung / Produktwartung 05-2450-001 des Produzenten Intel
Zur Seite of 28
Intel NetStructure ® Host Media Pr ocessing Software Release 1.5 f or Linux Soft war e Inst alla tion G uid e A ugust 2005 05-2450-00 1.
HMP Rel ease 1.5 for Linux Software Installa tion Guide – Augu st 2005 INFORMA TION IN THIS DOCUMENT IS PRO VIDED IN CONNECTION WITH I NTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED , BY EST OPPEL OR OT HERWISE, T O ANY INTELLECTU AL PROPER TY RIGHTS IS GRANTED BY THIS DOCUMENT .
HMP Releas e 1.5 for Linux Sof tware Install ation Guide – Aug ust 2005 3 Contents Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 About This Publication .
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 4 Re vision Histor y This re vision history summ arizes the chan ges made in each published v ersion of this docu ment. Document No. Publication Date Description of Revisions 05-2450-001 August 2005 Minor editor ial changes.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 5 About This Pub lication This pref ace provides the follo wing information about this do cument: • Purpos e • Intended Au.
6 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 About This Publication Relate d Inf ormation The follo wing docu ments and web sites provide more i nformation: • Intel NetS tructur e Host Me dia Pr ocessing Release 1.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 7 1 1 . Installation Over vie w This chapter provides the following information about installing Intel NetStr ucture ® Host Media Processing Software R elease 1.5 for Linux. • Major Installation Steps .
8 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 Installation Overv iew Once you ha ve installed the HMP Soft w are and download ed a license file 1 to your computer , you must acti vate the license on the t ar get system using the License Manager .
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 9 2 2 . Installing the Software This chapter provides procedures for installing and licensin g Intel NetStructure ® Host Media Processing S oftware Release 1.5 for Linux. This information is cont ained in the following sections: • Assumptions and Prereq uisites .
10 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 Installing the Software supplied with the software will allo w y ou to run the verif ication demo to confirm that you ha ve installed the HMP Software properly . Howev er, its features are limited and y ou may want to obtain another li cense.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 11 Installing the So ftware ============== =========== ================ =========== ================= === Intel ® NetStruct ure ™ Host Media Processing Software 1.5 Redistr ibutable Runtime IN STALLATION You will now h ave an oppo rtunity to insta ll software packages.
12 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 Installing the Software Y ou can config ure the HMP system immediately a fte r ins talling the HMP Software or at some later time. If you configure the system imm ediately after ins talling the software, enter y when asked “ Do you want to run config.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 13 Installing the So ftware 3. Enter the number that corresponds to the licen s e you wan t to activ ate. Details about the license you selected will appear so you can confirm that you really wan t to acti vate this license.
14 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 Installing the Software This tool wi ll attempt to automatically make chang es to /usr/share/ snmpd.conf. A backup cop y will be c reated as /usr/s hare/snmp/s nmpd.conf.backup.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 15 Installing the So ftware 2.5 Runni ng the V erif ication D emo If you w ould like to verify that you ha ve se t up the HMP Software pro perly , you can run th e verif icatio n demo.
16 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 Installing the Software CHEETAHSTART : Building shared memory. CHEETAHSTART : Done. Starting ssp _x86Linux_b oot: [ OK ] Starting Int el(R) NetSt ructure(TM) DM-f amily board (s) download phas e.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 17 Installing the So ftware Adminis tration Gu ide . Use the CLI procedure. Addition al helpful information in the sam e Admin.
18 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 Installing the Software.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 19 3 3 . Uninstalling the Software This chapter describ es ho w to uninstall Intel NetStructu re ® Host Media Processing Software Release 1. 5 for Linux. T o unin stall the HMP Release 1.
20 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 Uninstall ing the Software.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 21 4 4 . T r oubleshooting This chapter pr ovides the fo llowin g information about t roubleshooting problems encounter ed when installing Int el NetStructure ® Host Media Processing Softw are Release 1.
22 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 T roubleshooting 4.2 Und er s tanding the Install Error Messa g es This section describes the e rror messages that can appear during ins tall ation.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 23 T roubleshooting Installation P rerequisites ( OS, Kernel , Disk Space) Follo wing is a list of error messages and what must be done to correct the error condition. The erro r is in bold type and an explanation follo ws it: This program requires y ou to be a Superu ser .
24 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — A ugust 2005 T roubleshooting Invalid Resp onse. When enterin g your selection( s) from the in stall menu, you en tered something other than th e valid numbers and letters shown on th e menu.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — Augu st 2005 25 Glossar y DHCP: Dynamic Hos t Configu ration Protocol Dynamic Host Configuration Pr otocol: A TCP/IP protocol that enables PCs and workstations to get temporary or p ermanent IP addresses from cen t rally-adm i nis tered serv ers.
26 HMP Releas e 1.5 for Linux Sof tware Install ation Guide — Augu st 2005 SNMP A ge nt: The SNMP agent provides remote (or local) monitoring and limited control of Intel NetStruct ure ® de vices over an IP netw ork.
HMP Releas e 1.5 for Linux Sof tware Install ation Guide — Augu st 2005 27 Inde x A activating an HMP Software license 11 adminis trative p rivileges 7 , 9 B bin 22 C cfg 22 confi guring t he syst e.
28 HMP Rel ease 1.5 for Linux Software Installation Guide — August 2 005 SNMP C ompone nt Ma nager 21 , 22 software p ackages 21 Supe ruser 23 supp ort 24 T tria l li cen se 8 U uninstall HMP Release 1.
Ein wichtiger Punkt beim Kauf des Geräts Intel 05-2450-001 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Intel 05-2450-001 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Intel 05-2450-001 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Intel 05-2450-001 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Intel 05-2450-001 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Intel 05-2450-001 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Intel 05-2450-001 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Intel 05-2450-001. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Intel 05-2450-001 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.