Buccaneer GT Combination Boiler Falcon GTE Combination Boiler Installation, Assembly and Servicing Oil or Gas Fired Boilers Assembly and Installation Instructions for Ideal Buccaneer and Falcon Oil or.
2 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing Contents 1. General ........................................................................ 2 1.1 T echnical S pecifications of Combination Boilers .. 3 1.2 Main Dimensions ........
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 3 1.1 T echnical S pecifications of Combination Boilers Boiler: Maximum operating pressure : 4 bar Maximum operating temperature : 10.
4 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing GENERAL 1.2 Main Dimensions Buccaneer GT Combination Boiler Falcon GTE Combination Boiler G 335 F O flue gas nozzle Optional delive.
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 5 INST ALLA TION 2. INST ALLING THE BOILER 2.1 Boiler Location Sufficient sp ace shall be left clear around the boiler . The figure stated in metres in the drawings below are the minimum recommended dimensions for providing easy access around the boiler .
6 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing INST ALLA TION 2.5 Hydraulic Connections Installation must be carried out following the regulations in force, trade practices and the recommendations contained in this leaflet.
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 7 INST ALLA TION 2.8 Example of Installation The boiler-to-tank connection kit is placed between points A and B between the boiler and the heating circuit.
8 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 3 ASSEMBL Y 3.1 BUCCANEER GT COMBINA TION BOILER ASSEMBL Y Packaging : the tables below show the numbers of the packages which make up the boiler . The packages are listed in the order in which they are opened for assembly .
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 9 ASSEMBL Y Assembling the base and draining tube 1. Lay a sheet of paper in front of the boiler body , take the boiler body off the p allet and place it standing on the furnace door .
10 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing ASSEMBL Y 2 Assembling the boiler onto the tank - Place the boiler on the tank so that it is positioned on the first two marks on the front of the tank. - Assemble the boiler as instructed in views 3 - 13 of Buccaneer GT boiler Assembly Instructions.
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 11 ASSEMBL Y Boiler GTE 4 150 GTE 5 150 GTE 4 250 GTE 5 250 Boiler Body delivered loose - front section - intermediate section - rear.
12 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing ASSEMBL Y 37 39 38 Assemble the boiler as instructed in figures 1 - 16 Assembling the boiler on the hot water tank - Place the boiler on the tank if required with a handling tool (if required).
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 13 ASSEMBL Y 3.3 Hydraulic Boiler to T ank Connections Kit (BH46) Connection kit BH46, provides connections from the tank to the boiler .
14 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing ASSEMBL Y 4. CONTROLS 4.1 Description The boiler connections shall be performed by a qualified professional only . Strict compliance with these operating and connecting instructions is a precondition for the correct operation of the boiler 1.
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 15 ASSEMBL Y 4.3 Electrical Connections The electrical wiring has been carefully checked in the factory and the internal connections of the control panel must not be modified in any event.
16 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing - Install domestic hot water sensor cable A (e.g. for Buccaneer GT) as shown and fix it with plastic clips B . - Insert the sensor in the thimble tube of the tank. ASSEMBL Y - Connect as directed in the diagram on the following pages.
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 17 ASSEMBL Y 1. Instructions for use Regulating the storage temperature of hot water for sanitary systems: The regulating button A allows for the average temperature of stored sanitary hot water to be adjusted between 10 and 80ºC, with a hard point at 6 (about 60ºC).
18 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing - Introduce the bulb G of the limiter thermostat into the boiler pocket. - Connect the charging pump to the boiler control console, ensuring that the terminals live (L), neutral (N) and earth ( ) are properly attached.
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 19 ASSEMBL Y 4 . 6 Heating and Domestic Hot W ater Installation (with MB1 module) 4.
20 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 5. COMMISSIONING ASSEMBL Y - Ensure connections are watertight. - V ent the tank heat exchanger as follows: 1. Unscrew the auto vent cap (P)* a few turns. 2. T urn the antisyphon valve screw 10 to open position (O) 3.
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 21 SERVICING 6. MAINTENANCE AND PERIODIC CHECKS • Safety valve or group • Magnesium anode The magnesium anode must be checked at least every two years.
22 Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing NOTES.
Buccaneer GT , Falcon GTE - Installation, Assembly & Servicing 23 NOTES.
Caradon Plumbing Limited, P .O. Box 103, National Ave, Kingston upon Hull, HU5 4JN. T elephone: 01482 492 251 Fax: 01482 448 858. Registration No. London 322 137. Caradon Plumbing Limited pursues a policy of continuing improvement in the design and performance of its products.
Ein wichtiger Punkt beim Kauf des Geräts IDEAL INDUSTRIES BUC5034 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie IDEAL INDUSTRIES BUC5034 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für IDEAL INDUSTRIES BUC5034 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von IDEAL INDUSTRIES BUC5034 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über IDEAL INDUSTRIES BUC5034 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon IDEAL INDUSTRIES BUC5034 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von IDEAL INDUSTRIES BUC5034 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit IDEAL INDUSTRIES BUC5034. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei IDEAL INDUSTRIES BUC5034 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.