DE
IBM logo
Offizielle Bedienungsanleitung

IBM 8688

262 Seiten·17 MB·Überwachungskamera·PDF·ENNLJA
IBM 8688
Inhaltsverzeichnis 227 Abschnitte About this manual · Important safety information · Online support · Contents · … AnzeigenAusblenden
About this manualp.5Important safety informationp.5Online supportp.5Contentsp.7Chapter 1. General informationp.11Related publicationsp.11Notices and statements in this bookp.12Features and specificationsp.13What your IBM xSeries 450 offersp.14Server controls and indicatorsp.14Front viewp.15Rear viewp.16Server power featuresp.18Turning on the serverp.18Turning off the serverp.18Chapter 2. Configuring the serverp.21Using the Extensible Firmware Interface (EFI) Boot Managerp.21Using the Configuration/Setup Utility programp.22Starting the Configuration/Setup Utility programp.22Configuration/Setup Utility menu choicesp.22Passwordsp.24Using the LSI Logic Configuration Utility programp.25Setting up the Remote Supervisor Adapterp.26Remote Supervisor Adapter featuresp.26Setup requirementsp.26Cabling and configuring the Remote Supervisor Adapterp.28Cabling the Ethernet LAN port and serial portp.28Configuring the adapterp.30Using the ASM interconnect networkp.36Planning and cabling the interconnect networkp.36Forwarding alertsp.37Connecting the ASM Interconnect module to the xSeries 450p.37ASM interconnect network configuration examplesp.38Configuring the Gigabit Ethernet controllerp.41Chapter 3. Diagnosticsp.43General checkoutp.43Diagnostic tools overviewp.45POST error codes and messagesp.45System-error logsp.46Light Path Diagnostics featurep.46The diagnostics panelp.47LEDs on the top of the serverp.47LEDs on the system boardsp.47Diagnostic displayp.47Diagnostic programs, error codes, and messagesp.48Text messagesp.48Starting the AMIDiag programp.48Starting the AMIDiag program from the serverp.48Updating the firmwarep.49AMIDiag menusp.50Using AMIDiag keysp.50Running AMIDiag testsp.51Running the AMIDiag program in Batch Modep.51Error-log viewerp.52Quitting testsp.52System diagnostic testsp.52Processor testp.52System Board Testp.53PCI System Testp.53Multiprocessor Testp.53Memory diagnostic testsp.54IDE device diagnostic testsp.54IDE CD-ROM testsp.55IDE DVD testsp.55ATAPI removables testp.56SCSI diagnostic testsp.56SCSI Disk Buffer Testp.57SCSI Disk Self Diagnostic Testp.57SCSI Disk Read Testp.57SCSI Disk Write Testp.58SCSI Disk Format Testp.58SCSI Disk Spin Down Testp.58SCSI Disk Quick Testp.58SCSI CD-ROM testsp.59SCSI Tape Testp.60Video diagnostic testsp.61Running video testsp.62Video Monitor Testp.62Video Controller Testp.63USB diagnostic testsp.63USB Functionality Testp.63USB Keyboard Testp.63USB Mouse Testp.70Miscellaneous diagnostic testsp.70Serial port testp.70LED Testp.71RXE Port Testp.71Advanced System Management Testp.72Options menup.73Edit Batch Parametersp.73Load Batch Parametersp.78Save Batch Parametersp.79Generate Reportp.79Toggle All Tests in Menup.80Run Selected Testsp.80Toggle Hidden Test Displayp.80Ethernet diagnostic testsp.80Diagnostic error code tablesp.80Small computer system interface (SCSI) messagesp.81Recovering SAL/EFI codep.81Clearing a power-on passwordp.82Clearing CMOSp.83Power checkoutp.84Troubleshooting the Ethernet controllerp.85Network connection problemsp.85Ethernet controller troubleshooting chartp.86Ethernet controller messagesp.86Chapter 4. Installing optionsp.87Installation guidelinesp.87System reliability considerationsp.87Working inside a server with power onp.87Handling static-sensitive devicesp.88Major components of the xSeries 450 serverp.88Connector and LED locationsp.90Memory board internal connectors and LEDsp.90Memory switch card LEDsp.91Processor board internal connectors and LEDsp.92Midplane board connectors and LEDsp.94PCI-X board internal connectors and LEDsp.96I/O-board internal connectorsp.97I/O-board jumpersp.97Remote Supervisor Adapter connectors and LEDsp.98Opening the coverp.98Removing and replacing the bezelp.99Removing and replacing a hot-swap power supplyp.100Installing an adapterp.102Installing a hot-swap hard disk drivep.105Installing a 1.44 MB diskette drivep.106Installing a CD-ROM or DVD-ROM drivep.107Installing memoryp.108Installing and replacing a microprocessor and power modulep.110Replacing and troubleshooting fansp.117Replacing fan 1 or 2p.117Replacing fan 3 or 4p.118Replacing the batteryp.119Completing the installationp.121Closing the coverp.121Connecting the cablesp.121Updating your server configurationp.122Installing the server in a rackp.123Chapter 5. Field replaceable unitsp.125Memory-board assemblyp.125Memory boardp.125Memory-board voltage regulator module (VRM)p.126Memory switch card and cablep.128Processor-board assemblyp.129Microprocessor and power modulep.131Processor-board VRMp.132PCI-X board assemblyp.133Midplane boardp.135Midplane-board VRMp.136PCI-X boardp.137Active PCI assemblyp.139I/O board, riser card, and Remote Supervisor Adapterp.140Restoring the nonvolatile EFI variablesp.144Top cover assemblyp.147Top power boardp.148Hard disk drive backplanep.148Media bay cardp.149Memory-board retaining latchesp.150AC box assembly mechanismp.151Media-extract mechanismp.153Power/reset card assemblyp.154Light Path cardp.154Chapter 6. Symptom-to-FRU indexp.157Light Path LED errorsp.157System-error log entriesp.159SAL/EFI messagesp.160Service processor messagesp.164Diagnostic error codesp.169System-error codesp.169IDE CD test error codesp.171ATAPI removables test error codesp.172IDE DVD-ROM drive test error codesp.174SCSI test error codesp.174Video test error codesp.177USB test error codesp.177Serial port test error codesp.179Advanced System Management error codesp.180RXE port error codesp.183Memory test error codesp.184LED error codesp.185Error symptomsp.186Power supply LED errorsp.190Diagnostic display error codesp.191Hardware status error codesp.191SAL/EFI progress codesp.193SCSI error messagesp.194Ethernet error messagesp.195Undetermined problemsp.195Chapter 7. Parts listing xSeries 450 Type 8688p.197Systemp.197Figure Ap.200Figure Bp.201Keyboard CRUsp.202Power cord CRUsp.203Appendix A. Getting help and technical assistancep.205Before you callp.205Using the documentationp.205Getting help and information from the World Wide Webp.205Software service and supportp.206Hardware service and supportp.206Appendix B. Related service informationp.207Safety informationp.207General safetyp.207Electrical safetyp.208Safety inspection guidep.209Handling static-sensitive devicesp.210Grounding requirementsp.210Safety notices (multilingual translations)p.211Appendix C. Noticesp.215Edition noticep.215Trademarksp.216Important notesp.216Product recycling and disposalp.217Battery return programp.217Electronic emission noticesp.218Federal Communications Commission (FCC) statementp.218Industry Canada Class A emission compliance statementp.218Australia and New Zealand Class A statementp.218United Kingdom telecommunications safety requirementp.218European Union EMC Directive conformance statementp.218Taiwanese Class A warning statementp.219Chinese Class A warning statementp.219Japanese Voluntary Control Council for Interference (VCCI) statementp.219Power cordsp.219Indexp.223
Page 1 of the IBM 8688 user manual —
Seite 1 · Zum Vergrößern klicken
Seite 1

E Rserver

Page 2 of the IBM 8688 user manual
Seite 2 · Zum Vergrößern klicken
Seite 2
Page 2 of the IBM 8688 user manual
Page 3 of the IBM 8688 user manual —
Seite 3 · Zum Vergrößern klicken
Seite 3

ERserver

Page 4 of the IBM 8688 user manual
Seite 4 · Zum Vergrößern klicken
Seite 4

Fifth Edition (February 2004)

The most recent version of this document is available on the World Wide Web at http://www.ibm.com/pc/support

The following paragraph does not apply the United Kingdom or any country where such provisions are inconsistent with local law:

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION ″AS IS″ WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time.

This publication was developed for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed in this document in other countries, and the information is subject to change without notice. Consult your local IBM representative for information on the products, services, and features available in your area.

Requests for technical information about IBM products should be made to your IBM reseller or IBM marketing representative.

© Copyright International Business Machines Corporation 2003. All rights reserved. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

Page 5 of the IBM 8688 user manual — Online support
Seite 5 · Zum Vergrößern klicken
Seite 5

About this manual

This manual contains diagnostic information, a Symptom-to-FRU index, service information, error codes, error messages, and configuration information for the IBM®

Eserver™xSeries® 450 Type 8688 server.

servicers who are familiar with IBM products. Before servicing an IBM product, be sure to review “Safety information” on page 197.

Important safety information

Be sure to read all caution and danger statements in this book before performing any of the instructions. See “Safety information” on page 197.

Leia todas as instruções de cuidado e perigo antes de executar qualquer operação.

IBM 8688 — Important safety information diagram (page 5)
Abb. 1 · Important safety information

Prenez connaissance de toutes les consignes de type Attention et Danger avant de procéder aux opérations décrites par les instructions.

Lesen Sie alle Sicherheitshinweise, bevor Sie eine Anweisung ausführen.

Accertarsi di leggere tutti gli avvisi di attenzione e di pericolo prima di effettuare qualsiasi operazione.

Lea atentamente todas las declaraciones de precaución y peligro ante de llevar a cabo cualquier operación.

ADVERTENCIA: El contacto con el cable de este producto o con cables de accesorios que se venden junto con este producto, pueden exponerle al plomo, un elemento químico que en el estado de California de los Estados Unidos está considerado como un causante de cancer y de defectos congénitos, además de otros riesgos reproductivos. Lávese las manos después de usar el producto.

Online support

You can download the most current diagnostic, system abstraction layer/extensible firmware interface (SAL/EFI) flash, and device driver files from http://www.ibm.com/pc/support on the World Wide Web.

© Copyright IBM Corp. 2003 iii

Page 6 of the IBM 8688 user manual — About this manual
Seite 6 · Zum Vergrößern klicken
Seite 6

iv IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide

Page 7 of the IBM 8688 user manual — Inhaltsverzeichnis
Seite 7 · Inhalt
Inhalt

Inhalt

About this manualp.5Important safety informationp.5Online supportp.5Contentsp.7Chapter 1. General informationp.11Related publicationsp.11Notices and statements in this bookp.12Features and specificationsp.13What your IBM xSeries 450 offersp.14Server controls and indicatorsp.14Front viewp.15Rear viewp.16Server power featuresp.18Turning on the serverp.18Turning off the serverp.18Chapter 2. Configuring the serverp.21Using the Extensible Firmware Interface (EFI) Boot Managerp.21Using the Configuration/Setup Utility programp.22Starting the Configuration/Setup Utility programp.22Configuration/Setup Utility menu choicesp.22Passwordsp.24Using the LSI Logic Configuration Utility programp.25Setting up the Remote Supervisor Adapterp.26Remote Supervisor Adapter featuresp.26Setup requirementsp.26Cabling and configuring the Remote Supervisor Adapterp.28Cabling the Ethernet LAN port and serial portp.28Configuring the adapterp.30Using the ASM interconnect networkp.36Planning and cabling the interconnect networkp.36Forwarding alertsp.37Connecting the ASM Interconnect module to the xSeries 450p.37ASM interconnect network configuration examplesp.38Configuring the Gigabit Ethernet controllerp.41Chapter 3. Diagnosticsp.43General checkoutp.43Diagnostic tools overviewp.45POST error codes and messagesp.45System-error logsp.46Light Path Diagnostics featurep.46The diagnostics panelp.47LEDs on the top of the serverp.47LEDs on the system boardsp.47Diagnostic displayp.47Diagnostic programs, error codes, and messagesp.48Text messagesp.48Starting the AMIDiag programp.48Starting the AMIDiag program from the serverp.48Updating the firmwarep.49AMIDiag menusp.50Using AMIDiag keysp.50Running AMIDiag testsp.51Running the AMIDiag program in Batch Modep.51Error-log viewerp.52Quitting testsp.52System diagnostic testsp.52Processor testp.52System Board Testp.53PCI System Testp.53Multiprocessor Testp.53Memory diagnostic testsp.54IDE device diagnostic testsp.54IDE CD-ROM testsp.55IDE DVD testsp.55ATAPI removables testp.56SCSI diagnostic testsp.56SCSI Disk Buffer Testp.57SCSI Disk Self Diagnostic Testp.57SCSI Disk Read Testp.57SCSI Disk Write Testp.58SCSI Disk Format Testp.58SCSI Disk Spin Down Testp.58SCSI Disk Quick Testp.58SCSI CD-ROM testsp.59SCSI Tape Testp.60Video diagnostic testsp.61Running video testsp.62Video Monitor Testp.62Video Controller Testp.63USB diagnostic testsp.63USB Functionality Testp.63USB Keyboard Testp.63USB Mouse Testp.70Miscellaneous diagnostic testsp.70Serial port testp.70LED Testp.71RXE Port Testp.71Advanced System Management Testp.72Options menup.73Edit Batch Parametersp.73Load Batch Parametersp.78Save Batch Parametersp.79Generate Reportp.79Toggle All Tests in Menup.80Run Selected Testsp.80Toggle Hidden Test Displayp.80Ethernet diagnostic testsp.80Diagnostic error code tablesp.80Small computer system interface (SCSI) messagesp.81Recovering SAL/EFI codep.81Clearing a power-on passwordp.82Clearing CMOSp.83Power checkoutp.84Troubleshooting the Ethernet controllerp.85Network connection problemsp.85Ethernet controller troubleshooting chartp.86Ethernet controller messagesp.86Chapter 4. Installing optionsp.87Installation guidelinesp.87System reliability considerationsp.87Working inside a server with power onp.87Handling static-sensitive devicesp.88Major components of the xSeries 450 serverp.88Connector and LED locationsp.90Memory board internal connectors and LEDsp.90Memory switch card LEDsp.91Processor board internal connectors and LEDsp.92Midplane board connectors and LEDsp.94PCI-X board internal connectors and LEDsp.96I/O-board internal connectorsp.97I/O-board jumpersp.97Remote Supervisor Adapter connectors and LEDsp.98Opening the coverp.98Removing and replacing the bezelp.99Removing and replacing a hot-swap power supplyp.100Installing an adapterp.102Installing a hot-swap hard disk drivep.105Installing a 1.44 MB diskette drivep.106Installing a CD-ROM or DVD-ROM drivep.107Installing memoryp.108Installing and replacing a microprocessor and power modulep.110Replacing and troubleshooting fansp.117Replacing fan 1 or 2p.117Replacing fan 3 or 4p.118Replacing the batteryp.119Completing the installationp.121Closing the coverp.121Connecting the cablesp.121Updating your server configurationp.122Installing the server in a rackp.123Chapter 5. Field replaceable unitsp.125Memory-board assemblyp.125Memory boardp.125Memory-board voltage regulator module (VRM)p.126Memory switch card and cablep.128Processor-board assemblyp.129Microprocessor and power modulep.131Processor-board VRMp.132PCI-X board assemblyp.133Midplane boardp.135Midplane-board VRMp.136PCI-X boardp.137Active PCI assemblyp.139I/O board, riser card, and Remote Supervisor Adapterp.140Restoring the nonvolatile EFI variablesp.144Top cover assemblyp.147Top power boardp.148Hard disk drive backplanep.148Media bay cardp.149Memory-board retaining latchesp.150AC box assembly mechanismp.151Media-extract mechanismp.153Power/reset card assemblyp.154Light Path cardp.154Chapter 6. Symptom-to-FRU indexp.157Light Path LED errorsp.157System-error log entriesp.159SAL/EFI messagesp.160Service processor messagesp.164Diagnostic error codesp.169System-error codesp.169IDE CD test error codesp.171ATAPI removables test error codesp.172IDE DVD-ROM drive test error codesp.174SCSI test error codesp.174Video test error codesp.177USB test error codesp.177Serial port test error codesp.179Advanced System Management error codesp.180RXE port error codesp.183Memory test error codesp.184LED error codesp.185Error symptomsp.186Power supply LED errorsp.190Diagnostic display error codesp.191Hardware status error codesp.191SAL/EFI progress codesp.193SCSI error messagesp.194Ethernet error messagesp.195Undetermined problemsp.195Chapter 7. Parts listing xSeries 450 Type 8688p.197Systemp.197Figure Ap.200Figure Bp.201Keyboard CRUsp.202Power cord CRUsp.203Appendix A. Getting help and technical assistancep.205Before you callp.205Using the documentationp.205Getting help and information from the World Wide Webp.205Software service and supportp.206Hardware service and supportp.206Appendix B. Related service informationp.207Safety informationp.207General safetyp.207Electrical safetyp.208Safety inspection guidep.209Handling static-sensitive devicesp.210Grounding requirementsp.210Safety notices (multilingual translations)p.211Appendix C. Noticesp.215Edition noticep.215Trademarksp.216Important notesp.216Product recycling and disposalp.217Battery return programp.217Electronic emission noticesp.218Federal Communications Commission (FCC) statementp.218Industry Canada Class A emission compliance statementp.218Australia and New Zealand Class A statementp.218United Kingdom telecommunications safety requirementp.218European Union EMC Directive conformance statementp.218Taiwanese Class A warning statementp.219Chinese Class A warning statementp.219Japanese Voluntary Control Council for Interference (VCCI) statementp.219Power cordsp.219Indexp.223
Page 11 of the IBM 8688 user manual — Related publications
Seite 11 · Zum Vergrößern klicken
Seite 11

Chapter 1. General information

Your IBM Eserver xSeries 450 Type 8688 server is a high-performance symmetric multiprocessing (SMP) server. It is ideally suited for networking environments that require superior microprocessor performance, efficient memory management, flexibility, and reliable data storage.

The xSeries 450 server contains several IBM X-Architecture™technologies, which help increase server performance and reliability.

Your server comes with a limited warranty. If you have access to the World Wide Web, you can obtain up-to-date information about your server model and other IBM server products at http://www.ibm.com/pc/us/eserver/xseries/

Your server serial number and model number are on the ID label located on the left side of the bezel just above the hard disk drives. You will need these numbers when you register your server with IBM. The information label containing the serial number, machine type, model number, and agency marks for your server is on the bottom of the server.

Related publications

This Hardware Maintenance Manual and Troubleshooting Guide contains information to help you solve the problem yourself or to provide helpful information to a service technician.

In addition to this Hardware Maintenance Manual and Troubleshooting Guide, the following xSeries 450 Type 8688 documentation is provided with your server:

v Installation Guide This printed publication contains setup and installation instructions. v Rack Installation Instructions This printed publication contains the instructions to install your server in a rack. v Safety Book This multilingual publication is provided in Portable Document Format (PDF) on the IBM xSeries Documentation CD. It contains translated versions of the caution and danger statements that appear in the documentation for your server. Each caution and danger statement has an assigned number, which you can use to locate the corresponding statement in your native language. v User’s Guide This publication is provided in PDF on the IBM xSeries Documentation CD. It contains general information about your server, including information about features, how to configure your server, and how to get help. v Option Installation Guide This publication is provided in PDF on the IBM xSeries Documentation CD. It contains instructions to install, remove, and connect optional devices supported by your server.

Depending on your server model, additional publications might be included on the IBM xSeries Documentation CD.

© Copyright IBM Corp. 2003 1

Page 12 of the IBM 8688 user manual — Notices and statements in this book
Seite 12 · Zum Vergrößern klicken
Seite 12

Notices and statements in this book

The caution and danger statements used in this book also appear in the multilingual Safety Information book provided on the IBM xSeries Documentation CD. Each caution and danger statement is numbered for easy reference to the corresponding statements in the safety book.

The following types of notices and statements are used in this book: v Note: These notices provide important tips, guidance, or advice.

v Important: These notices provide information or advice that might help you avoid inconvenient or problem situations.

v Attention: These notices indicate possible damage to programs, devices, or data. An attention notice is placed just before the instruction or situation in which damage could occur.

v Caution: These statements indicate situations that can be potentially hazardous to you. A caution statement is placed just before the description of a potentially hazardous procedure step or situation.

v Danger: These statements indicate situations that can be potentially lethal or extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation.

Page 13 of the IBM 8688 user manual — DVD/CD-RW: IDE
Seite 13 · Zum Vergrößern klicken
Seite 13

Features and specifications

The following table provides a summary of the features and specifications of your xSeries 450.

Microprocessor: v Intel®™Itanium® 2 900 MHz or higher, depending on server model v 1.5 MB (minimum) Level-3 cache v 200 MHz front-side bus (FSB), at two data transfers per cycle, yielding a 400 MHz system bus (minimum) v Support for up to four microprocessors v XceL4™Server Accelerator Cache: 64 MB

Power supply:

Heat output:

Two power supplies: 550 watts at 100-127 V ac or 1050 watts at 200-240 V ac (hot-swappable and redundant at 200-240 V ac only)

Approximate heat output in British thermal units (Btu) per hour v Minimum configuration: 854 Btu (250 watts) v Maximum configuration: 2646 Btu (775 watts)

Video: v Integrated ATI RageXL video v PCI bus interface v Compatible with SVGA v 8 MB SDRAM video memory

Electrical input: v Sine-wave input (50-60 Hz) required v Input voltage low range: – Minimum: 100 V ac – Maximum: 127 V ac v Input voltage high range: – Minimum: 200 V ac – Maximum: 240 V ac v Input kilovolt-amperes (kVA) approximately: – Minimum: 0.250 kVA – Maximum: 1.3 kVA

Active Memory™: v Minimum: 1 GB v Maximum: 40 GB v Type: 2-way interleaved PC2100, ECC DDR SDRAM, registered DIMMs only v Supports 512 MB, 1 GB, and 2 GB dual inline memory modules (DIMMs)

Size (4 U): v Height: 17.8 cm (7 inches, 4 U) v Depth: 69.85 cm (27.5 inches) v Width: 48.3 cm (19 inches) v Maximum weight: 38.6 kg (85 lb), depending on your configuration

Integrated functionsv Broadcom 5704 10/100/1000 dual port Ethernet controller v Light Path Diagnostics ™

Notes: 1. Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use. 2. These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate.

Drives standard:

v One external and one internal Ultra320 SCSI port (dual-channel integrated controller with RAID capabilities) v Remote Supervisor Adapter (service processor) – ASM interconnect (peer-to-peer) port – Ethernet port – Serial port v IDE controller v RXE Management port v RXE Expansion ports v Three USB ports v SCSI ports v Serial port v Wake on LAN®

DVD/CD-RW: IDE

Expansion bays: v Two removable media bays (one DVD/CD-RW preinstalled) v Supports up to two internal Ultra320 SCSI hard disk drives

Active™PCI-X expansion slots:

Six 64-bit Active PCI-X expansion slots: v Two 66 MHz PCI-X slots v Two 100 MHZ PCI-X slots v Two 133 MHZ PCI-X slots

Cooling:

Environment: v Air temperature: – Server on: 10° to 35°C (50.0° to 95.0°F). Altitude: 0 to 914 m (2998.7 ft) – Server on: 10° to 32°C (50.0° to 89.6°F). Altitude: 0 to 2133 m (6998.0 ft) – Server off: -40° to 60°C (-104° to 140°F). Maximum altitude: 2133 m (6998.0 ft) v Humidity: – Server on: 8% to 80% – Server off: 5% to 100%

Four hot-swap fans v Two 150 mm x 51 mm fans v Two 150 mm x 38 mm fans

Acoustical noise emissions: v Declared sound power, idle: 6.5 bels v Declared sound power, operating: 6.5 bels v Bystander sound pressure, idle: 49 dBa v Bystander sound pressure, operating: 49 dBa

Chapter 1. General information 3

Page 14 of the IBM 8688 user manual — Server controls and indicators
Seite 14 · Zum Vergrößern klicken
Seite 14

What your IBM xSeries 450 offers

Your server includes the following features and technologies:

v IBM Enterprise X-Architecture technology Enterprise X-Architecture technology combines proven, innovative IBM designs to make your Intel-processor-based server powerful, scalable, and reliable. For more information, go to http://www.ibm.com/pc/us/eserver/xseries/xarchitecture/enterprise/index.html on the World Wide Web.

– Active Memory The Active Memory feature improves the reliability of memory through memory mirroring, memory scrubbing, and the Memory ProteXion™feature. For more information, see the User’s Guide. – Large system memory The memory bus supports up to 40 GB of system memory. The memory controller provides error code correcting (ECC) support for up to 28 industry-standard PC2100, 2.5 V, 184-pin, 133 megahertz (MHz), registered, double data rate (DDR), synchronous dynamic random access memory (SDRAM) dual inline memory modules (DIMMs). – XceL4™Server Accelerator Cache The XceL4 Server Accelerator Cache provides 64 MB of external Level-4 cache, which increases effective memory bandwidth.

v Light Path Diagnostics feature

The Light Path Diagnostics feature provides LEDs to help you isolate problems. For more information, see “Light Path Diagnostics feature” on page 36. v System-management capabilities The server comes with a Remote Supervisor Adapter installed in a dedicated connector. This adapter, in conjunction with the system-management software that comes with the server, enables you to manage the functions of the server locally and remotely. The Remote Supervisor Adapter also provides system monitoring, event recording, and dial-out alert capability. v Integrated network support Your server comes with an integrated Broadcom Gigabit Ethernet controller, which supports connection to a 10-Mbps, 100-Mbps, or 1000-Mbps network. For more information, see “Configuring the Gigabit Ethernet controller” on page 31.

Server controls and indicators

The following section identifies the controls and indicators on the front and rear of your server.

Page 15 of the IBM 8688 user manual — Front view
Seite 15 · Zum Vergrößern klicken
Seite 15

Front view

Hard disk drive activity LED (green)

IBM 8688 — Front view diagram (page 15)
Abb. 2 · Front view

Power-on LED: This green LED turns on and stays on when you turn on your server, and it flashes when the server is in Standby mode.

Hard disk drive activity LED: When this green LED is lit, it indicates that the hard disk drive is in use.

Hard disk drive error LED: On some server models, each hot-swap hard disk drive has an error LED. The interpretation of a flashing error LED depends on the SCSI controller connected to the hot-swap drive. When the drive is connected to the integrated SCSI controller with RAID capabilities, a flashing error LED indicates that the drive is a secondary drive in a mirrored pair and the drive is being synchronized.

USB connector: This is an automatically configured port that you can use to connect one or more USB devices to the front of the server, using Plug and Play technology.

System-error LED: When this amber LED is lit, it indicates that a system error has occurred.

Information LED: When this amber LED is lit, it indicates that information about a system error has been placed in the system-error log.

SCSI activity LED: When this green LED is lit, it indicates that there is activity on the SCSI bus.

Locator LED: This blue LED is used to help you locate other devices connected to the server.

Drive-eject button: Push this button to release a drive from the server.

DVD/CD-RW eject button: Push this button to release a DVD or CD from the drive.

DVD/CD-RW drive activity LED: When this LED is lit, it indicates that the DVD/CD-RW drive is in use.

Chapter 1. General information 5

Show 5 more labels / short text on this page
Power button · Reset button · USB connector · Drive eject button · DVD/CD-RW eject button
Page 16 of the IBM 8688 user manual — Rear view
Seite 16 · Zum Vergrößern klicken
Seite 16

Drive-eject button: Push this button to release a drive from the server.

Power-supply latch: This latch is used to secure the power supply in place.

Reset button: Press this button to reset the server and run the power-on self-test (POST). You might need to use a pen or the end of a straightened paper clip to press the button.

Power button: Press this button to manually turn the server on or off.

Rear view

RXE Expansion Port (B) connector

System power connector (1)

System power connector (2)

Remote Supervisor Adapter connectors and LEDs

USB 2 connector USB 1 connector RXE Management Port connector

RXE Expansion Port (A) connector

System power connectors (1 and 2): The system power cords are connected to these two connectors to provide power to the system.

RXE Expansion Port B connector: Use this port to connect the server to a remote input/output (I/O) enclosure.

Serial connector: The signal cable for a system console or other serial device connects to the serial port.

Show 5 more labels / short text on this page
Serial connector · Ethernet LEDs · Gigabit Ethernet connectors · SCSI connector · Video connector
Page 17 of the IBM 8688 user manual — Rear view
Seite 17 · Zum Vergrößern klicken
Seite 17

Remote Supervisor Adapter connectors and LEDs: This group of ports and indicators on the back of the server are used for system-management information and control.

Ethernet activity LED (green)

External power supply connector

Ethernet link LED (green)

v External power-supply connector: This connector is not supported on this server. v Error LED: This amber LED is lit when a system-management error has occurred. v RS-485 connector: Signal cables for managing expansion module resources are attached to this connector. v Ethernet activity LED: This green LED is lit when there is activity on the Ethernet LAN attached to the Ethernet connector. v Ethernet link LED: This green LED is lit when there is an active link connection on the Ethernet controller for the Ethernet port. v Ethernet connector: Ethernet signal cables are attached to the Ethernet connector. v System-management connector: Signal cables for modems or other serial devices are attached to this connector. v Power LED: This green LED goes on and stays on when you plug in your server.

Ethernet LEDs: These LEDs are lit green when there is an active link connection on the Gigabit Ethernet controller and flash amber when there is activity on the Ethernet LAN.

Gigabit Ethernet connectors: Gigabit Ethernet signal cables are connected to the Gigabit Ethernet ports. These ports support 10/100/1000 Mbps data transfer rates.

RXE Expansion Port A connector: Use this connector to attach the server to a remote I/O enclosure.

Video connector: The signal cable for a monitor attaches to the video connector.

USB 2 connector: This is an automatically configured port that you can use to attach one or more USB devices to the server, using Plug and Play technology.

USB 1 connector: This is an automatically configured port that you can use to attach one or more USB devices to the server, using Plug and Play technology.

RXE Management Port connector: Use this connector to attach a management cable from the server to a remote I/O enclosure.

Chapter 1. General information 7

Show 5 more labels / short text on this page
Error LED (amber) · RS-485 connector (RJ14) · Power LED (green) · Ethernet connector System-management · connector
Page 18 of the IBM 8688 user manual — Turning off the server
Seite 18 · Zum Vergrößern klicken
Seite 18

SCSI connector: This connector is used to attach external SCSI devices to the server.

Server power features

When the server is connected to an ac power source but is not turned on, the operating system does not run, and all core logic except for the service processor is shut down; however, the server can respond to requests from the service processor, such as a remote request to turn on the server. The power-on LED flashes to indicate that the server is connected to ac power but is not turned on.

Turning on the server

Approximately 20 seconds after the server is connected to ac power, the power-control button becomes active, and you can turn on the server and start the operating system by pressing the power-control button. The server can also be turned on in any of the following ways: v If a power failure occurs while the server is turned on, the server will restart automatically when power is restored. v If ac power is present, the server can be turned on from the Remote Supervisor Adapter user interface. v The Wake on LAN feature can turn on the server.

Notes: 1. The power supplies are hot-swappable and redundant only at 200-240 V ac. 2. Both power supplies must be connected to the power source for operation at 100-127 V ac. 3. During normal operation, both power supplies must be installed for proper operation. 4. While the server is powering up, the power-on LED on the front of the server is lit. When the server is connected to ac power but is not turned on, the power-on LED on the front of the server flashes.

Turning off the server

When you turn off the server and leave it connected to ac power, the server can respond to requests from the service processor, such as a remote request to turn on the server. To remove all power from the server, you must disconnect it from the power source.

Some operating systems require an orderly shutdown before you turn off the server. See your operating-system documentation for information about shutting down the operating system.

Page 19 of the IBM 8688 user manual — Server power features
Seite 19 · Zum Vergrößern klicken
Seite 19

Statement 5:

The server can be turned off in any of the following ways: v You can turn off the server from the operating system, if your operating system supports this feature. After an orderly shutdown of the operating system, the server will be turned off automatically. v You can press the power-control button to start an orderly shutdown of the operating system and turn off the server if your operating system supports this feature. v If the operating system stops functioning, you can press and hold the power-control button for more than 4 seconds to turn off the server. v If the server is connected to an Advanced System Management interconnect network, the server can be turned off from the Remote Supervisor Adapter user interface.

2. If you disconnect the server from the power source, wait approximately 15 seconds for the server to stop running before you open the cover. Watch for the power-on LED on the front of the server to stop flashing.

Chapter 1. General information 9

Page 20 of the IBM 8688 user manual — Server power features
Seite 20 · Zum Vergrößern klicken
Seite 20
Page 20 of the IBM 8688 user manual — Server power features
Page 21 of the IBM 8688 user manual — Using the Extensible Firmware Interface (EFI) Boot Manager
Seite 21 · Zum Vergrößern klicken
Seite 21

Chapter 2. Configuring the server

The following configuration programs and capabilities come with your server: v Extensible Firmware Interface (EFI) Boot Manager program

This program controls the startup environment. You can use this program to configure startup options, such as starting the server to an operating system on the network or on media, or to the EFI Boot Maintenance Manager main menu. See “Using the Extensible Firmware Interface (EFI) Boot Manager” for more information. v Configuration/Setup Utility program

This program is an EFI utility that comes with your server. You can use this program to set the date and time and to set passwords. See “Using the Configuration/Setup Utility program” on page 12 for more information.

v LSI Logic Configuration Utility program With the built-in LSI Logic Configuration Utility program, you can configure the integrated SCSI controller and the devices that are attached to it. See “Using the LSI Logic Configuration Utility program” on page 15 for more information. v Remote Supervisor Adapter configuration process See “Setting up the Remote Supervisor Adapter” on page 16 for information about setting up and cabling the Remote Supervisor Adapter for use with an Advanced System Management (ASM) network. v Ethernet controller configuration process To configure the integrated Ethernet controller, see “Configuring the Gigabit Ethernet controller” on page 31.

Using the Extensible Firmware Interface (EFI) Boot Manager

You can use the EFI Boot Manager to configure a variety of start options, including starting to an external device or to a specific file. The following table provides a summary of the selection s available from the EFI Boot Maintenance Manager main menu.

Boot from a file Automatically adds EFI applications as start options, or you can start the server from a specific file.

Add a boot option Adds a start option to the EFI Boot Manager. You specify the option by providing the name of the EFI application.

Delete boot options Deletes a specific start option or all start options.

Change boot order Controls the relative order in which the EFI Boot Manager attempts start options.

Manage boot next setting Defines a start option to use one time (the next start operation).

Set automatic boot timeout value

Defines the amount of time before the server automatically starts without user intervention.

Select active console output devices

Displays the list of available console output devices, as contained in the ConOutDev list. You can select output console devices from the list.

Select active console input devices

Displays the list of available console input devices, as contained in the ConInDev list and the subset detailed in the ConIn variable.

© Copyright IBM Corp. 2003 11

Selection Description

Page 22 of the IBM 8688 user manual — Configuration/Setup Utility menu choices
Seite 22 · Zum Vergrößern klicken
Seite 22

Select active error devices Displays the list of available error devices as contained in the ErrOutDev list and the subset detailed in the ErrOut variable.

Cold reset Performs a platform-specific cold reset of the server. Note: A cold reset typically is a full-platform reset.

Exit Returns control to the EFI Boot Manager startup options. This will display the active start devices.

Complete the following steps to start the EFI Boot Manager and access the EFI Boot Maintenance Manager main menu: 1. Turn on the server.

2. From the EFI Boot Manager startup options, select the EFI Boot Maintenance Manager main menu.
3. Follow the instructions that appear on the screen.

Using the Configuration/Setup Utility program

Use the Configuration/Setup Utility program to: v Enable memory mirroring v Set the date and time v Set passwords

The following sections provide instructions for starting the Configuration/Setup Utility program and descriptions of the menu choices that are available.

Starting the Configuration/Setup Utility program

Complete the following steps to start the Configuration/Setup Utility program:

1. Turn on the server. 2. From the EFI Boot Manager startup options, select the Configuration/Setup Utility program. 3. Follow the instructions that appear on the screen.

Configuration/Setup Utility menu choices

The following choices are on the Configuration/Setup Utility main menu. Depending on the version of the system abstraction layer/extensible firmware interface (SAL/EFI) code in your server, some menu choices might differ slightly from these descriptions. v System Summary Select this choice to display configuration information. This includes the type and speed of the microprocessor and the amount of memory that is installed.

v System Information – System Product Data Select this choice to view system information, such as the machine type and model, the server serial number, and the revision level, date, and build level of the SAL/EFI code, diagnostic code, and ASM adapter code. – System Card Data Select this choice to view identifying information about the PCI-X board, processor board, memory board, power supplies, hard disk drive backplane, and power backplane.

Selection Description

Page 23 of the IBM 8688 user manual — Using the Configuration/Setup Utility program
Seite 23 · Zum Vergrößern klicken
Seite 23

v Devices and I/O Ports Select this choice to view information about, enable, or disable the integrated SCSI and Ethernet controllers.

Notes: 1. The default setting is Enable for all of the controllers. If you select Disable, the system will not configure the disabled device, and the operating system will not detect the device. (This is equivalent to unplugging the device.) 2. If the integrated SCSI controller is disabled and no other controller for a mass storage device is installed, operating-system startup cannot occur. v Date and Time Select this choice to set the system date and time and to change the system time that is sent to the Remote Supervisor Adapter when the server is started. The system time is in a 24-hour format (hour:minute:second). All fields are required.

v System Security Select this choice to set or change the power-on or administrator password. See “Passwords” on page 14 for more information. The Remote Control Security Settings menu is located in System Security. This menu is used to set the Failed Login Threshold and the Automatic Lockout Delay. You can also use this menu to save, change, or delete a remote-control password.

v Advanced Setup Select this choice to change values for advanced hardware features, such as memory configuration, cache control, PCI configuration, and system-management settings. – Memory Configuration Select this choice to manually enable a set, or bank, of four DIMMs used for memory mirroring and to enable memory mirroring. If a memory error is detected during POST or memory configuration, the server can automatically disable the failing DIMM bank and continue operating with reduced memory capacity. If this occurs, you must manually enable the DIMM bank after the problem is corrected. Use the arrow keys to highlight the bank that you want to enable. Press Enter to view detailed information about your selection; then, use the arrow keys to select Enable. – Cache Control Select this choice to enable or disable the Xcel4 cache. – PCI Slot Information Select this choice to configure and view information about the PCI-X slots and devices in your server and those located in the remote expansion enclosure, if one is attached. – System Management Settings Select this choice to set the server to restart automatically after a nonmaskable interrupt (NMI) occurs. You can also enable the system to assign the memory mapped I/O (MMIO) above 4 GB.

Chapter 2. Configuring the server 13

Page 24 of the IBM 8688 user manual — Passwords
Seite 24 · Zum Vergrößern klicken
Seite 24

v System Event and Error Log Select this choice to view or clear the system-error log and enable or disable debug options. Use the debug options to define the severity level of messages viewable during POST. – Select View System Error Log to view the system-error log. The system-error log contains all the system error and warning messages that the server has generated. You can use the arrow keys to move between pages in the system-error log.

– Select Clear System Error Log to clear the system-error log. v Save Settings Select this choice to save your customized settings (except PCI-X Slot Information changes, the date and time, and password settings). v Save Settings and Reboot Select this choice to save your customized settings (except PCI-X Slot Information changes, the date and time, and password settings), and restart the server. v Restore Settings Select this choice to delete your changes (except PCI-X Slot Information changes, the date and time, and password settings), and restore the previous settings. v Load Default Settings Select this choice to restore the factory settings (except PCI-X Slot Information changes, the date and time, and password settings). v Exit Setup

If you have made any changes and not saved them (except PCI-X Slot Information changes, the date and time, and password settings), the program will prompt you to save the changes or exit without saving the changes.

Passwords After you select this choice, you can set a power-on password or an administrator password.

Power-on password: You can use any combination of up to seven characters (A–Z, a–z, and 0–9) for your power-on password. Keep a record of your password in a secure place. When a power-on password is set, POST does not complete until you type the password. If you forget the power-on password, you can regain access to the server through one of the following methods: v Remove the battery and then reinstall the battery (see “Replacing the battery” on page 109).

Attention: Before changing any switch settings or moving any jumpers, turn off the server and peripheral devices, and disconnect all power cords and external cables. v Move the jumper on J20 to positions 2 and 3, and restart the server to remove the power-on password. Restart the server, and start the Configuration/Setup Utility program to change the power-on password. For detailed instructions, see “Clearing a power-on password” on page 72.

Administrator password: Select this choice to set an administrator password. The administrator password provides access to all choices on the Configuration/Setup Utility main menu. You can set, change, or delete both the administrator and power-on passwords and allow a user to change a power-on

Page 25 of the IBM 8688 user manual — Using the LSI Logic Configuration Utility program
Seite 25 · Zum Vergrößern klicken
Seite 25

password. You can use any combination of up to seven characters (A–Z, a–z, and 0–9) for your power-on password. Keep a record of your password in a secure place.

Using the LSI Logic Configuration Utility program

The LSI Logic Configuration program is a built-in, menu-driven configuration utility program. You can use it to: v Configure a redundant array of independent disks (RAID) v Perform a low-level format on a hard disk v Set the SCSI device scan order

v Set the SCSI ID for a controller

Notes: 1. The integrated SCSI controller with RAID capabilities in your server supports RAID level 1 operation; however, you might need to download an updated release of the system abstraction layer/extensible firmware interface (SAL/EFI) code for the firmware and device driver to provide support for RAID level 1. To download the updated LSI SCSI controller device driver with support for RAID Level 1, when available, go to http://www.ibm.com/pc/support/ on the World Wide Web. 2. You must configure your SCSI controller with RAID capabilities before you install your operating system. If the hard disk has been previously partitioned, run DISKPART.EFI after mirroring but before installing the operating system to completely remove the previous partition table. A pointer to DISKPART.EFI can be found on the Resource CD that comes with the server. 3. If you install a different type of RAID adapter in your server, use the configuration method supplied with the RAID adapter to view or change SCSI settings for attached devices. 4. The internal hard disk drives can connect only to the integrated SCSI controller with RAID capabilities.

Complete the following steps to start the LSI Logic Configuration Utility program:

1. Turn on the server, and watch the monitor screen. 2. From the EFI Boot Manager startup options, select EFI Shell [Built-In], and press Enter. 3. Type drivers -b to display the device driver handle identifiers. Not the device driver handle identifier in the far left column for the LSI Logic Ultra320 SCSI device driver. 4. Type drvcfg drv to display the controller identifiers. Note the controller identifier for the LSI Logic Ultra320 SCSI device driver. 5. Type drvcfg drv ctrl -s to run the utility (where drv is the device driver handle identifier and ctrl is the controller identifer). 6. Type drvcfg /? for help.

You can use the LSI Logic Configuration Utility program to perform a low-level format on a SCSI hard disk drive. Complete the following steps to format a drive: 1. Select the controller channel for the drive from the list of adapters. 2. Select Device Properties.

Chapter 2. Configuring the server 15

Page 26 of the IBM 8688 user manual — Setup requirements
Seite 26 · Zum Vergrößern klicken
Seite 26
3. Use the arrow keys to select the drive to format. Attention: Low-level formatting removes all data from the hard disk. If there is data you want to save, back up the hard disk before continuing this procedure. 4. Use the arrow keys or the End key to scroll to the right. 5. Select Format , and press Enter to start.

Setting up the Remote Supervisor Adapter

This section describes the Remote Supervisor Adapter features and setup requirements. It also explains how to cable and configure the adapter for use on an Advanced System Management (ASM) network so that you can manage the server from a remote location. For more detailed information, see the Remote Supervisor Adapter User’s Guide on the IBM xSeries Documentation CD.

Remote Supervisor Adapter features

The Remote Supervisor Adapter has the following features: v Continuous health monitoring and control v Advanced Predictive Failure Analysis® (PFA) v Configurable notification and alerts v Time-stamped event logs that can be saved in nonvolatile memory and attached to e-mail alerts

v Remote graphics console redirection v LAN, serial, and Advanced System Management (ASM) interconnect remote access v Point-to-point protocol (PPP) support v Simple Network Management Protocol (SNMP) v Domain Name System (DNS) and Dynamic Host Configuration Protocol (DHCP) support v Remote power control v Microsoft® Windows® Server 2003, Enterprise Edition (64-bit) blue-screen capture v Remote firmware update and access to critical server settings v Optional, independent power, which enables around-the-clock access to the server, even if the server is turned off

Setup requirements

Before you set up the Remote Supervisor Adapter, you must download the EFI Remote Supervisor Utility program from http://www.ibm.com/pc/support/ on the World Wide Web, and create a CD.

You might need to enable the server to use the CD creation feature to create the Remote Supervisor Utility CD. If you have Microsoft Windows Server 2003, complete the following steps to enable the CD creation feature.

format using the CD creation feature. 1. Right-click My Computer. 2. Click Manage. 3. Double-click Services and Applications.

4. Double-click IMAPI CD-Burning COM Service .
Page 27 of the IBM 8688 user manual — Setting up the Remote Supervisor Adapter
Seite 27 · Zum Vergrößern klicken
Seite 27
5. Click Manual for Startup Type . 6. Click OK to close the window. 7. Log off Windows Explorer, and logon again.

To copy an ISO image to a CD using SuSe Linux, type cdrecord -v dev=b, t, 1 in the command prompt, where b is the SCSI bus, t is the target device, and l is the logical unit number (LUN) for your DVD/CD-RW device.

To determine the appropriate SCSI bus, the target device, and the LUN for the DVD/CD-RW for the device, type cdrecord -scanbus, and press Enter.

You might need to add a startup option in the elilo.conf file to enable IDE to SCSI emulation. If the IDE DVD/CD-RW drive is the first IDE device in your startup order, complete the following steps: 1. Add the following startup option to the stanza for the kernel you are starting up: append="hda=ide-scsi", and restart the server. 2. When the server starts up, type # lsmod , and look for ide-scsi in the list of modules currently loaded to verify that the IDE to SCSI driver is loaded. 3. If the IDE to SCSI driver is not loaded, type insmod ide-scsi to manually load the driver.

Complete the following tasks before you set up the Remote Supervisor Adapter:

v Install the operating system on the server, using the documentation that comes with the operating system. v Ensure that the remote alert recipients are IBM Director-enabled servers with UM Server Extensions, if you are configuring remote alert recipients for Director over LAN or Director over modem. v If you want to use a Web browser to access the Remote Supervisor Adapter remotely, ensure that your Web browser meets the following requirements: – Microsoft Internet Explorer 4.0 (with Service Pack 1) or later

– Netscape Navigator 4.72 or later (version 6.0 is not currently supported) – Java™enabled Web browser (see your browser documentation or online help for instructions for enabling its Java support) – Support for JavaScript™1.2 or later (see your browser documentation or online help for instructions for enabling its JavaScript support) – Support of HTTP version 1.0 or later – Minimum display resolution of 800 x 600 pixels and 256 colors

the double-byte character set (DBCS) languages.

Chapter 2. Configuring the server 17

Page 28 of the IBM 8688 user manual — Cabling and configuring the Remote Supervisor Adapter
Seite 28 · Zum Vergrößern klicken
Seite 28

Cabling and configuring the Remote Supervisor Adapter

Complete the following tasks to cable and configure the Remote Supervisor Adapter.

create a backup copy of the configuration. If you need to replace the adapter in the future, you can use the backup copy to restore the configuration and resume normal operation more quickly. See the Remote Supervisor Adapter User’s Guide on the IBM xSeries Documentation CD for details.

Task 1. Connect the Ethernet and serial port cables. See “Cabling the Ethernet LAN port and serial port.”

Task 2. Perform the initial configuration to enable remote access to the Remote Supervisor Adapter. See “Enabling remote access to the adapter” on page 20. Completing this task enables you to: 1. Configure the Ethernet port 2. Configure the serial (COM) port 3. Set up the point-to-point protocol

Task 3. Configure the remote-control password to enable the ASM Web interface remote-control features. See “Configuring the remote-control password” on page 25.

Task 4. Install the ASM device drivers. See “Installing Advanced System Management device drivers” on page 25.

For service, assistance, or additional information, see Appendix A, “Getting help and technical assistance,” on page 195.

Cabling the Ethernet LAN port and serial port You can manage the server remotely through the Remote Supervisor Adapter using one of the user interfaces and one of the connection methods that are described in Table 1 on page 19. Perform the cabling procedure for the interface method you want to use.

If you plan to set up an ASM interconnect network, before you begin cabling the server, see “Using the ASM interconnect network” on page 26 for instructions for cabling the ASM interconnect port and setting up the network. You might want to review the information in “ASM interconnect network configuration examples” on page 28 before you connect the cables. Then, return here to start the cabling procedures.

Page 29 of the IBM 8688 user manual — P - P
Seite 29 · Zum Vergrößern klicken
Seite 29

Table 1. Cabling tasks to enable remote access to the Remote Supervisor Adapter

User interface to Remote Supervisor Adapter

Connection to Remote Supervisor Adapter

For the cabling procedure, see

ASM Web interface using the HTTP protocol

LAN using the Ethernet port “Cabling the Ethernet LAN port” on page 19

Text-based user interface using the Telnet protocol

Text-based user interface using a modem or a null modem

Serial (COM) port “Cabling the serial (COM) port” on page 20

ASM Web interface using point-to-point protocol (PPP)

Text-based user interface using the Telnet protocol over PPP

Cabling the Ethernet LAN port: This section describes how to cable the Ethernet LAN port.

Complete the following steps to attach the Ethernet cables: 1. Connect one end of a Category 3 or Category 5 Ethernet cable to the Ethernet connector on the Remote Supervisor Adapter. Connect the other end of the Ethernet cable to the network.

2. Check the Ethernet LEDs to ensure that the network connection is working. The following illustration shows the locations of the LEDs.

(amber) External power supply connector

P - P

(COM)

(RJ-14)

When the green Ethernet activity LED flashes, it indicates that there is Ethernet activity.

When the green Ethernet link LED is lit, it indicates that the Ethernet cable is connected properly.

If you want to use the serial port connection, continue with “Cabling the serial (COM) port” on page 20; otherwise, go to “Configuring the adapter” on page 20.

Chapter 2. Configuring the server 19

Show 12 more labels / short text on this page
Lithium battery · Ethernet activity · LED (green) · Ethernet link · Error LED · LED (green) · Serial connector · Ethernet connector (RJ-45) · Power LED (green) · ASM Interconnect port · Ethernet activity LED · Ethernet link LED
Page 30 of the IBM 8688 user manual — Configuring the adapter
Seite 30 · Zum Vergrößern klicken
Seite 30

Cabling the serial (COM) port: To cable the serial (COM) port, connect a modem or null modem cable to the serial connector on the Remote Supervisor Adapter. Then, continue with “Configuring the adapter.”

Configuring the adapter This section describes how to enable remote access to the Remote Supervisor Adapter and install ASM device drivers. These procedures assume that you have a keyboard and pointing device attached to the server.

Enabling remote access to the adapter: The Remote Supervisor Adapter must be configured to enable remote access through the Ethernet connector or the serial connector. Perform the configuration procedure for the interface method you want to use.

text-based interface, see the Remote Supervisor Adapter User’s Guide on the IBM xSeries Documentation CD.

Table 2. Configuration tasks to enable remote access to the Remote Supervisor Adapter

User interface to Remote Supervisor Adapter

Connection to Remote Supervisor Adapter

For the configuration procedure, see

ASM Web interface using the HTTP protocol

LAN using the Ethernet port “Configuring the Ethernet settings for Web-based remote access” Text-based user interface using the Telnet protocol

Text-based user interface using a modem or a null modem

Serial (COM) port “Configuring the serial port for text-based remote access” on page 22 and “Setting up point-to-point protocol” on page 23 ASM Web interface using point-to-point protocol (PPP)

Text-based user interface using the Telnet protocol over PPP

Configuring the Ethernet settings for Web-based remote access: If you have an accessible, active, and configured Dynamic Host Configuration Protocol (DHCP) server on the network, the host name, IP address, gateway address, subnet mask, and DNS server IP address are set automatically. The default value should have no effect on whether you have to do any other configuration. If you need to configure the serial port, go to “Configuring the serial port for text-based remote access” on page 22; otherwise, go to “Configuring the remote-control password” on page 25.

If you do not have a DHCP server on the network, complete the following steps to configure the Ethernet settings.

requirements” on page 16. 1. With the server turned off, insert the CD containing the EFI Remote Supervisor Utility program into the drive; then, turn on the server. The utility starts automatically, displaying the Remote Supervisor Utility window. 2. Use the Up Arrow and Down Arrow keys (↑and ↓) to select Configuration Settings; then, press Enter. The Configuration Settings window opens.

Page 31 of the IBM 8688 user manual — Configuring the adapter
Seite 31 · Zum Vergrößern klicken
Seite 31
3. Use the arrow keys to select Ethernet Settings , and press Enter. The Ethernet Settings window opens.

different.

IBM 8688 — Configuring the adapter diagram (page 31)
Abb. 3 · Configuring the adapter
4. Use the arrow keys to navigate to each field. Your system administrator can provide the information for the following fields:

The default setting is Enabled; verify that it is still set to Enabled.

Type the IP address of the Remote Supervisor Adapter.

Type the subnet mask used by the Remote Supervisor Adapter. The default value is 255.255.255.0.

Type the IP address of the gateway.

Type the hostname of the Remote Supervisor Adapter. The default hostname is ASMA

Chapter 2. Configuring the server 21

Show 5 more labels / short text on this page
Network Interface · IP Address · Subnet Mask · Gateway · Host Name
Page 32 of the IBM 8688 user manual — Configuring the adapter
Seite 32 · Zum Vergrößern klicken
Seite 32
12. If you also want to configure the serial port, continue with “Configuring the serial port for text-based remote access.” Otherwise, go to “Installing Advanced System Management device drivers” on page 25.

Configuring the serial port for text-based remote access: Complete the following steps to configure the Remote Supervisor Adapter serial port for access using a modem or null modem. If you completed the procedure for configuring the Ethernet port and the Configuration Settings window is open, go to step 4.

1. With the server turned off, insert the CD containing the EFI Remote Supervisor Utility program into the drive, and turn on the server. 2. The utility starts automatically, displaying the Remote Supervisor Utility window. 3. Use the Up Arrow and Down Arrow keys ( ↑ and ↓ ) to select Configuration Settings , and press Enter. The Configuration Settings window opens. 4. Use the arrow keys to select Modem Settings , and press Enter. The Modem Settings window opens.

different.

IBM 8688 — Configuring the adapter diagram (page 32)
Abb. 4 · Configuring the adapter
5. Verify the following serial port values:

The default is 57600. Make sure that the baud rate matches the baud rate of the device you are connecting to the serial port on the Remote Supervisor Adapter.

The default setting is Disabled. If you are using point-to-point protocol (PPP), set this field to Enabled. If the value in this field is Enabled when the server is restarted, the serial port remains dedicated to system management and is not returned to the operating system.

drivers as described in “Installing Advanced System Management device drivers” on page 25.

If the serial port is shared with the operating system, it is dedicated to the Remote Supervisor Adapter only while the server is turned off or

Baud Rate · Dedicated to ASM

Page 33 of the IBM 8688 user manual — Configuring the adapter
Seite 33 · Zum Vergrößern klicken
Seite 33

during POST. The port is returned to the operating system after POST completes. You can view the port using the operating system or any application. The Remote Supervisor Adapter takes over the port from the operating system only when information about a critical event is received. The Remote Supervisor Adapter dials out and transmits an alert and keeps the port dedicated until the server is restarted. The port is no longer available to the operating system or applications.

Parity The default setting is None.

The default is 1.

Note: The data bits value is preset to 8 and cannot be changed. For detailed information about the serial port and modem settings, see the Remote Supervisor Adapter User’s Guide on the IBM xSeries Documentation CD. 6. If you made changes to the serial port settings, press F6 to apply the change. 7. Press Esc to return to the Configuration Settings window. If you need to set up point-to-point protocol, go to “Setting up point-to-point protocol.” 8. Press Esc to return to the Remote Supervisor Adapter Utility main window. 9. Use the arrow keys to select Exit Utility from the menu, or press Esc to close the Remote Supervisor Adapter Utility program.

10. Remove the CD from the drive. The Remote Supervisor Adapter restarts automatically. 11. Continue with “Setting up point-to-point protocol.”

Setting up point-to-point protocol: The Remote Supervisor Adapter serial port supports PPP. PPP enables TCP/IP communication over the serial port, which enables Web-based management and TELNET sessions over a modem. To set up PPP, complete the following steps. If you completed the procedure for configuring the serial port and the Configuration Settings window is open, go to step 4.

1. With the server turned off, insert the CD containing the EFI Remote Supervisor Utility program into the drive, and turn on the server. 2. The utility starts automatically, displaying the Remote Supervisor Utility window. 3. Use the Up Arrow and Down Arrow keys ( ↑ and ↓ ) to select Configuration Settings ; then, press Enter. The Configuration Settings window opens. 4. Use the arrow keys to select PPP Settings , and press Enter. The PPP Settings window opens.

Chapter 2. Configuring the server 23

Stop Bits

Page 34 of the IBM 8688 user manual — Configuring the adapter
Seite 34 · Zum Vergrößern klicken
Seite 34

different.

IBM 8688 — Configuring the adapter diagram (page 34)
Abb. 5 · Configuring the adapter
5. Use the arrow keys to navigate to each field. Verify the values in the following fields:

The default setting is Disabled. Change this field to Enabled.

The default value is 192.96.1.1. You can use the default value or another value, but the server must be able to establish a connection to that address. The default IP address (local and remote) is easily reconfigurable.

The default value is 255.255.255.255.

The value is set to PPP.

The default value is 192.96.1.2.

The default is CHAP then PAP. Make sure that the value in this field matches your client settings. For detailed information about the PPP settings, see the information about configuring PPP access over a serial port in the Remote Supervisor Adapter User’s Guide on the IBM xSeries Documentation CD. 6. Press F6 to apply the changes. 7. Press Esc. After the Warning message displays, press Enter to restart the Remote Supervisor Adapter. 8. Press Esc to return to the Configuration Settings window. If you need to configure the serial port, go to “Configuring the serial port for text-based remote access” on page 22.

9. Press Esc to return to the Remote Supervisor Adapter Utility main window. 10. Use the arrow keys to select Exit Utility from the menu, or press Esc to close the Remote Supervisor Adapter Utility program. 11. Remove the CD from the drive. The server restarts automatically.
Show 6 more labels / short text on this page
Network Interface · IP Address · Subnet Mask · Line Type · Remote IP Address · Authentication Protocol
Page 35 of the IBM 8688 user manual — Configuring the adapter
Seite 35 · Zum Vergrößern klicken
Seite 35
12. Continue with “Installing Advanced System Management device drivers.”

Installing Advanced System Management device drivers: You must install the ASM device drivers for the server to enable communication between the Remote Supervisor Adapter and the server in which it is installed. You can obtain the most current device drivers from http://www.ibm.com/pc/support/ on the World Wide Web.

v You must install the operating system on the server before you install the ASM device drivers. For information about installing the operating system, see the documentation that comes with the operating system. v Before installing the ASM device drivers for the Remote Supervisor Adapter, stop any system-management application.

After you install the ASM device drivers, go to “Configuring the remote-control password” to set the remote-control password.

Configuring the remote-control password: If you want to use the remote-control features of the Remote Supervisor Adapter ASM Web interface, you must configure the remote-control password using the Configuration/Setup Utility program.

To set up a remote-control password, complete the following steps:

1. Start the server and watch the monitor screen. 2. From the EFI Boot Manager startup options, select the Configuration/Setup Utility program. 3. Use the Up Arrow and Down Arrow keys (↑and ↓) to select System Security; then, press Enter. The System Security window opens. 4. Select Remote Control Security Settings, and press Enter. The Remote Control Security Settings window opens. 5. Type the remote-control password that you will use each time you log into the remote-control features of the Remote Supervisor Adapter ASM Web Interface. 6. Select Save New Remote Control Password, and press Enter.

7. In the System Security window, press Esc. 8. Select Save Settings , and press Enter. 9. Confirm your selection, and exit the Configuration/Setup Utility program.
10. Continue with “Completing the configuration.”

Completing the configuration: To complete the configuration of the Remote Supervisor Adapter, see the Remote Supervisor Adapter User’s Guide on the IBM xSeries Documentation CD. The tasks include the following: v Defining the login IDs and passwords v Selecting the events that will receive alert notification v Monitoring remote server status using the ASM Web interface or a text-based user interface v Controlling the server remotely

If you want to set up an ASM interconnect network and have not already done so, continue with “Using the ASM interconnect network” on page 26. If you do not want to set up an ASM interconnect network, Remote Supervisor Adapter configuration is now complete. To start managing the server remotely, see the Remote Supervisor Adapter User’s Guide on the IBM xSeries Documentation CD.

Chapter 2. Configuring the server 25

Page 36 of the IBM 8688 user manual — Using the ASM interconnect network
Seite 36 · Zum Vergrößern klicken
Seite 36

Using the ASM interconnect network

This section explains how to configure and connect the server to function within an ASM interconnect network.

The ASM interconnect network can include as many as 12 individual ASM connections in a single bus. These connections can include Remote Supervisor Adapters, ASM processors, and ASM PCI adapters. When the clients and servers are connected, they use the ASM interconnect network to share ASM resources, information, and alerts among multiple servers without having to add additional communications hardware or network interface adapters.

An ASM interconnect network provides two levels of functionality. First, the ASM interconnect network enables you to configure settings and to control the servers where other Remote Supervisor Adapters, ASM processors, and ASM PCI adapters on the network reside. Second, the ASM interconnect network enables other interconnect network devices to use the resources (Ethernet or modem) of other Remote Supervisor Adapters, ASM processors, and ASM PCI adapters in the ASM interconnect network for sending alerts. This interconnect network is used when Remote Supervisor Adapters, ASM processors, or ASM PCI adapters cannot send an alert and must forward the information to another one of these devices to send the alert.

Planning and cabling the interconnect network To support the most recent ASM features, a Remote Supervisor Adapter must be the main gateway interconnect to the ASM interconnect bus if the bus also includes servers with ASM PCI adapters or ASM processors. The Remote Supervisor Adapter forwards the ASM information generated by the servers attached to the ASM interconnect bus to other servers on the Ethernet network. The connected ASM processors and ASM PCI adapters are managed through the new user interface and Web browser access of the Remote Supervisor Adapter.

firmware installed on the Remote Supervisor Adapter that is the main interconnect gateway for the ASM interconnect network. The most current level of firmware is available at http://www.ibm.com/pc/support/ on the World Wide Web. For more information about updating firmware, see “Updating the firmware” on page 39 and the Remote Supervisor Adapter User’s Guide on the IBM xSeries Documentation CD.

You must connect an ASM Interconnect module to the Remote Supervisor Adapter and to each xSeries 450 server that you connect to the ASM interconnect network bus.

To connect the servers, note the following setup and configuration considerations:

v Ensure that the ASM interconnect network is set up as a bus topology. You must connect the servers to the ASM interconnect network in a series, with terminated beginning and end points. v Ensure that the total combined length of all Ethernet cables connecting the server in the ASM interconnect network does not exceed 91 m (300 ft). v Each Remote Supervisor Adapter, ASM PCI adapter, or ASM processor that is connected to the ASM interconnect network bus counts as one connection. For

Page 37 of the IBM 8688 user manual — Forwarding alerts
Seite 37 · Zum Vergrößern klicken
Seite 37

example, if an ASM PCI adapter is installed in a server that has an ASM processor, the processor and the adapter connect to each other using one ASM interconnect connection, but the processor and the adapter count as two connections on the ASM interconnect network bus.

Forwarding alerts Remote Supervisor Adapters, ASM PCI adapters, and ASM processors that are connected to an ASM interconnect network share resources and system-management information. This section provides information on how alerts are forwarded in the ASM interconnect network.

During normal operation, each Remote Supervisor Adapter, ASM processor, or ASM PCI adapter on the ASM interconnect network communicates with the other processors and adapters on the network. Processors or adapters that have a modem or Ethernet connection notify the other processors and adapters that these communications resources are available for use by other servers on the ASM interconnect network. These resources are then used as ASM interconnect network resources, enabling Remote Supervisor Adapters, ASM processors, or ASM PCI adapters on the ASM interconnect network to send alerts using a modem or the network, even if they do not have a modem or network connection physically attached.

When alerts are generated, they are forwarded to the Remote Supervisor Adapter, ASM processor, or ASM PCI adapter on the ASM interconnect network that has the communication resources to forward the alert. If no system on the ASM interconnect network meets the requirements, the alert is set for transmission if the connection type is configured or becomes available later.

If multiple modems or network connections exist in the ASM interconnect network, you cannot specify which system will receive an alert or which will use its modem or network connection to forward the alert. If an alert is forwarded to a Remote Supervisor Adapter, ASM processor, or ASM PCI adapter that is unable to deliver the alert (for example, the modem it is configured to use has failed or the network cannot resolve the destination IP address), the processor or adapter attempts to forward the alert to another system on the ASM interconnect network that has the communication resources to forward the alert.

Alerts are typically sent once per connection type, but an alert is forwarded to another interconnect device if the resources exist on other interconnect devices in the network. For example, on a three ASM processor network where ASM processor 1 generates a modem alert, but does not have a modem and the other ASM processors have modems, the following might occur:

If ASM processor 1 generates an alert and the modem is unplugged from ASM processor 2 45 seconds prior to ASM processor 1 generating the alert, ASM processor 1 forwards the alert to ASM processor 2, having previously determined that ASM processor 2 has an available modem. When ASM processor 2 receives the forwarded alert, it determines that a modem is attached to ASM processor 3 and forwards the alert. Therefore, depending on the time frame (45 seconds) within which a resource (modem) fails, the alert might be forwarded multiple times until an interconnect device can send the alert.

Connecting the ASM Interconnect module to the xSeries 450 The ASM Interconnect module connects the Remote Supervisor Adapter to the ASM interconnect network. This module must be purchased separately.

Chapter 2. Configuring the server 27

Page 38 of the IBM 8688 user manual — ASM interconnect network configuration examples
Seite 38 · Zum Vergrößern klicken
Seite 38

To connect the ASM interconnect module to the Remote Supervisor Adapter, complete the following steps.

Attention: To avoid damage to the Ethernet connector, do not plug the ASM interconnect module into the Remote Supervisor Adapter Ethernet port. 1. Connect the ASM Interconnect module 1 to the Remote Supervisor Adapter ASM interconnect (peer-to-peer) port 2. This port is on the edge of the Remote Supervisor Adapter that is accessible from the rear of the server and is labeled RS485.

IBM 8688 — ASM interconnect network configuration examples diagram (page 38)
Abb. 6 · ASM interconnect network configuration examples
2. Connect one or two Category 3 or Category 5 Ethernet cables to the other end of the ASM Interconnect module. 3. Continue with “ASM interconnect network configuration examples.”

ASM interconnect network configuration examples The illustrations in this section show sample ASM interconnect network configurations.

Page 39 of the IBM 8688 user manual — ASM interconnect network configuration examples
Seite 39 · Zum Vergrößern klicken
Seite 39

The following illustration shows an Ethernet cable connecting the remote administrator system to the Remote Supervisor Adapter that is installed in an xSeries 450. Server 1 uses the LAN connection to forward system-management data generated by the other xSeries 450s in the ASM interconnect network bus to the remote system-management administrator.

IBM 8688 — ASM interconnect network configuration examples diagram (page 39)
Abb. 7 · ASM interconnect network configuration examples

Chapter 2. Configuring the server 29

Page 40 of the IBM 8688 user manual — ASM interconnect network configuration examples
Seite 40 · Zum Vergrößern klicken
Seite 40

The following illustration shows a modem connected to the serial port of the Remote Supervisor Adapter in the xSeries 450 on the left, a modem connected to the serial port of the Remote Supervisor Adapter in the xSeries 450 on the right, and a modem connected to the remote administrator system. Placing modems at opposite ends of the ASM interconnect network bus ensures that if an ASM interconnect connection in the bus fails, all of the servers on the ASM interconnect network have access to a modem to forward system-management data to the remote system-management administrator.

IBM 8688 — ASM interconnect network configuration examples diagram (page 40)
Abb. 8 · ASM interconnect network configuration examples
Page 41 of the IBM 8688 user manual — Configuring the Gigabit Ethernet controller
Seite 41 · Zum Vergrößern klicken
Seite 41

Configuring the Gigabit Ethernet controller

The Ethernet controllers are integrated on the I/O board. They provide an interface for connecting to a 10-Mbps, 100-Mbps, or 1-Gbps network and provide full-duplex (FDX) capability, which enables simultaneous transmission and reception of data on the network. If the Ethernet ports in your server support auto-negotiation, the controllers detect the data-transfer rate (10BASE-T, 100BASE-TX, or 1000BASE-T) and duplex mode (full-duplex or half-duplex) of the network and automatically operate at that rate and mode.

You do not need to set any jumpers or configure the controllers. However, you must install a device driver to enable the operating system to address the controllers. For device drivers and information about configuring the Ethernet controllers, see the Resource CD that comes with your server. For updated information about configuring the controllers, go to http://www.ibm.com/pc/support/ on the World Wide Web.

The following illustration shows the Ethernet controller port assignments, connectors, and LEDs.

Ethernet LED (port 0)

Ethernet LED (port 1)

Ethernet connector (port 1)

Ethernet connector (port 0)

Chapter 2. Configuring the server 31

Page 42 of the IBM 8688 user manual — Configuring the Gigabit Ethernet controller
Seite 42 · Zum Vergrößern klicken
Seite 42
Page 42 of the IBM 8688 user manual — Configuring the Gigabit Ethernet controller
Page 43 of the IBM 8688 user manual — General checkout
Seite 43 · Zum Vergrößern klicken
Seite 43

Chapter 3. Diagnostics

This section provides basic troubleshooting information to help you resolve some common problems that might occur with your server.

If you cannot locate and correct the problem using the information in this section, see Appendix A, “Getting help and technical assistance,” on page 195 for more information.

General checkout

The server diagnostic programs are stored in the upgradeable electronically erasable programmable read-only memory (EEPROM) on the I/O board and on the Resource CD. These programs provide the primary methods of testing the major components of the server.

If you cannot determine whether a problem is caused by the hardware or by the software, run the diagnostic programs to confirm that the hardware is working properly.

work to correct the cause of the first error message. After you correct the cause of the first error message, the other error messages usually will not occur the next time you run the test.

A failed server might be part of a shared hard disk drive cluster (two or more servers sharing one or more external storage devices). Before you run diagnostics, verify that the failing server is not part of a shared storage device cluster.

A server might be part of a cluster if:

v The server is identified as part of a cluster. v One or more external storage units are attached to the server and at least one of the attached storage units is also attached to another server or unidentifiable source. v One or more servers are located near the failing server.

If the failing server is suspected to be part of a shared hard disk drive cluster, run all diagnostic tests except those that test the storage unit (storage device residing in the storage unit) or the storage adapter attached to the storage unit.

Notes: 1. For servers that are part of a shared hard disk drive cluster, run one test at a time in looped mode. Do not run all tests in looped mode, because this could enable the hard disk drive diagnostic tests. 2. If multiple error codes are displayed, diagnose the first error code that is displayed. 3. If the server stops with a POST error, see “SAL/EFI messages” on page 150. 4. If the server stops and no error is displayed, see “Undetermined problems” on page 185. 5. For power supply problems, see “Power checkout” on page 74. 6. For safety information, see “Safety information” on page 197.

7. For intermittent problems, check the system-error log.

© Copyright IBM Corp. 2003 33

Page 44 of the IBM 8688 user manual — 003 DID THE DIAGNOSTIC PROGRAM START?
Seite 44 · Zum Vergrößern klicken
Seite 44

Follow the steps in this procedure to identify system problems.

001 IS THE SERVER PART OF A CLUSTER?

YES. Schedule maintenance for the system. Shut down all systems related to the cluster.

NO. Go to step 002.

002 IF THE SERVER IS NOT PART OF A CLUSTER:

If the operating system is running, do the following:

1. Check the Light Path. Go to “Light Path Diagnostics feature” on page 36 for more information. 2. Check the service processor system-error logs. a. If the system-error log indicates a damaged field replaceable unit (FRU), replace the FRU, and run the AMIDiag program to confirm that the problem has been solved. b. If the system-error log does not indicate a damaged FRU, check the Light Path.

If the operating system is not running, do the following: 1. Check the Light Path. Go to “Light Path Diagnostics feature” on page 36 for more information. 2. Check the service processor system-error logs. a. If the error log indicates a damaged field replaceable unit (FRU), replace the FRU, and run the AMIDiag program to confirm that the problem has been solved. b. If the error log does not indicate a damaged FRU, see “Undetermined problems” on page 185 3. Turn off the server and all external devices. 4. Check all cables and power cords. 5. Set all display controls to the middle position. 6. Turn on all external devices. 7. Turn on the server. 8. Monitor the screen and the serial port for POST errors, and record any POST error messages that are displayed on the screen. If an error is displayed, look up the first error in the “SAL/EFI messages” on page 150. 9. When the EFI Boot Manager starts, select Diagnostic from the menu, and press Enter to start the AMIDiag program.

003 DID THE DIAGNOSTIC PROGRAM START?

NO. Find the failure symptom in “Error symptoms” on page 176.

YES. Run the diagnostic programs. If necessary, see “Diagnostic programs, error codes, and messages” on page 38.

If you receive an error, see Chapter 6, “Symptom-to-FRU index,” on page 147.

If the diagnostic programs were completed successfully and you still suspect a problem, see “Undetermined problems” on page 185.

If the server does not turn on, see “Error symptoms” on page 176.

Page 45 of the IBM 8688 user manual — POST error codes and messages
Seite 45 · Zum Vergrößern klicken
Seite 45

Diagnostic tools overview

The following tools are available to help you identify and resolve hardware-related problems: v POST error messages The power-on self-test (POST) generates error messages to indicate the detection of a problem. See “POST error codes and messages” for more information. v System-error logs The system-error log contains all the error messages that were issued during POST. See “System-error logs” on page 36. v Light Path Diagnostics feature Use the Light Path Diagnostics feature to identify system errors quickly (see “Light Path Diagnostics feature” on page 36).

v Diagnostic display If a problem is detected with system power on or during initialization, an error code might be present in the two-hex character diagnostic display on the midplane board. See “Diagnostic display error codes” on page 181 for more information. v Diagnostic programs and error messages The AMIDiag program is the primary method of testing the major components of the server. The AMIDiag program is stored in the EEPROM on the I/O board. You can download the latest version of this program and copy it to a CD so that you can update the AMIDiag program. See “Starting the AMIDiag program” on page 38 for more information. The diagnostic program for the Ethernet controller is on the Resource CD. For instructions about using this CD, see “Troubleshooting the Ethernet controller” on page 75. v Product support page The IBM Web site has up-to-date information about IBM xSeries products, services, and support at http://www.ibm.com/eserver/xseries/ on the World Wide Web. You can find service information for your IBM products, including supported options, at http://www.ibm.com/pc/support/

POST error codes and messages

When you turn on the server, it performs a series of tests to check the operation of server components and some of the options installed in the server. This series of tests is called the power-on self-test, or POST.

If POST finishes without detecting any problems, the EFI Boot Manager screen appears. If POST detects a problem, an error message will be sent to either the serial port or the display screen. See “SAL/EFI messages” on page 150 for more information.

Chapter 3. Diagnostics 35

Page 46 of the IBM 8688 user manual — Light Path Diagnostics feature
Seite 46 · Zum Vergrößern klicken
Seite 46

System-error logs

The system-error log contains all messages issued during system initialization or normal system operation.

You can view the contents of the system-error log from the Configuration/Setup Utility program or from the service processor. To view error logs from the Configuration/Setup Utility program, start the Configuration/Setup Utility program; then, select Error Logs from the main menu. See “Starting the Configuration/Setup Utility program” on page 12 for more information.

You can also use the error-log viewer in the AMIDiag program. For information about viewing diagnostic program error logs from the AMIDiag program, see “Error-log viewer” on page 42.

Light Path Diagnostics feature

The Light Path Diagnostics panel is inside the Light Path Diagnostics drawer on the front right of the server. When you press on the front of the Light Path Diagnostics drawer, the Light Path Diagnostic panel is exposed.

The following illustration shows the location of the diagnostics panel. See “The diagnostics panel” on page 37 for information about identifying problems using the Light Path Diagnostic LEDs.

IBM 8688 — Light Path Diagnostics feature diagram (page 46)
Abb. 9 · Light Path Diagnostics feature

The system-error LED on the operator information panel is lit when certain system errors occur. If the system-error LED on the server is lit, one or more LEDs inside the server might be lit. Use the Light Path Diagnostics panel to identify the type of

Page 47 of the IBM 8688 user manual — Diagnostic display
Seite 47 · Zum Vergrößern klicken
Seite 47

error that occurred, and see “Light Path LED errors” on page 147 to help determine the cause of the error and the action you should take.

To view the LEDs on the various main boards, look at the board indicated by the diagnostic panel.

To acknowledge a system error but not take immediate action, press the REMIND button, and place the Light Path Diagnostics feature in Remind mode. The system-error LED flashes in Remind mode. If a new failure occurs, the system-error LED is lit again.

The diagnostics panel

The diagnostics panel should be the first place you look for help with identifying problems. If a system error occurs, the system-error LED on the front of this panel is lit. Press the front of the panel to open the diagnostics panel, and look for any lit LEDs. These lit LEDs can help you identify the possible cause of the error. Make a note of any LEDs that are lit, and then close the panel.

LEDs on the top of the server

You can also use the LEDs on the top of the server to find an error. If the BOARD LED on the diagnostics panel is lit, pull the server out, and view the top cover. In the center of the top cover is a set of six LEDs and the system service labels. The numbers next to the LEDs correspond to the numbers on the system service label. Note the lit LED, and see the numbered block on the system service label that corresponds to the lit LED. Then, follow the instructions, if any, in the numbered block.

LEDs on the system boards

To locate the actual component that caused the error, locate the lit LED next to that component.

For example:

A system error has occurred, and you have noted that the CPU LED is lit on the diagnostics panel. Referring to the LEDs on the top cover, you see that LED 2 is lit. You then locate the panel on the system service label with the number 2 on it. In this case, the instructions in the panel tell you that the problem occurred with one of the microprocessors. Follow the instructions to remove the processor-board assembly. See “Processor-board assembly” on page 119. Located on the circuit board is the light-path capacitor switch. Press and hold the switch until you locate the lit LED next to the defective microprocessor. Follow the instructions in “Microprocessor and power module” on page 121 and “Installing and replacing a microprocessor and power module” on page 100 to remove and replace the microprocessor.

For more information about LEDs and connectors, see “Connector and LED locations” on page 80.

Diagnostic display

If a problem is detected with system power on or during initialization, the two-hex character diagnostic display on the midplane board might show an error code. See “Midplane board connectors and LEDs” on page 84 and “Diagnostic display error codes” on page 181 for more information.

Chapter 3. Diagnostics 37

Page 48 of the IBM 8688 user manual — Starting the AMIDiag program
Seite 48 · Zum Vergrößern klicken
Seite 48

Diagnostic programs, error codes, and messages

Diagnostic error messages indicate that a problem exists. They are not intended to be used to identify a failing part. Troubleshooting and servicing of complex problems that are indicated by error messages should be performed by trained service personnel.

Sometimes the first error to occur causes additional errors. In this case, the server displays more than one error message. Always follow the suggested action instructions for the first error message that appears.

Chapter 6, “Symptom-to-FRU index,” on page 147 contains the error codes that might appear in the detailed test log and summary log when the diagnostic programs are run.

Text messages

The diagnostic text message format is as follows:

Function NameResult (test specific string)

where:

is the name of the function being tested when the error occurred. This corresponds to the function code (fff) shown in the error code format in the previous section.

can be one of the following:

Passed This result occurs when the diagnostic test is completed without any errors.

Failed This result occurs when the diagnostic test discovers an error.

Aborted This result occurs when you stop the diagnostic test before it is complete.

Starting the AMIDiag program

The AMIDiag program is stored in the EEPROM of the server. You can download the latest version from http://www.ibm.com/eserver/xseries/ on the World Wide Web.

Starting the AMIDiag program from the server Complete the following steps to start the AMIDiag program:

1. Turn on the server, and watch the screen.

level password that is set. That is, if an administrator password is set, you must type the administrator password, not the user password, to run the diagnostic programs. 2. When the EFI Boot Manager appears on the screen, select Diagnostic, and press Enter. 3. When the AMIDiag program screen appears, select the test you want to run from the menu that appears, and follow the instructions on the screen.

Function Name · Result

Page 49 of the IBM 8688 user manual — Updating the firmware
Seite 49 · Zum Vergrößern klicken
Seite 49

Notes: a. Press F1 while running the AMIDiag program to obtain help information. Press F1 from within a help screen to obtain online documentation from which you can select different categories. To exit from the help information and return to where you left off, press Esc. b. If the server stops during testing and you cannot continue, restart the server and try running the AMIDiag program again. If the problem remains, replace the component that was being tested when the server stopped.

c. When you exit the AMIDiag program, the server resets automatically. If the server does not reset automatically, manually reset the server before starting the operating system.

If the diagnostic programs do not detect any hardware errors but the problem persists during normal server operations, a software error might be the cause. If you suspect a software problem, see ″Software problems″ at “Error symptoms” on page 176 and the information that comes with the software package.

Updating the firmware If you have downloaded the latest version of the AMIDiag program from the World Wide Web, you can create a CD or save it to a valid file system on your server so that you can update the AMIDiag program on the server.

Before you can create a CD, you might need to enable the CD creating feature. For instructions to enable the CD creating feature using Microsoft Windows Server 2003, see “Setup requirements” on page 16. For instructions using another operating system, see the documentation for the operating system.

To create a CD with the latest version of the AMIDiag program, unzip the file that you downloaded from the World Wide Web, and copy it to a CD.

To use the service processor to update SAL/EFI, AMIDiag, or service processor firmware, complete the following steps: 1. Open the Remote Supervisor Adapter Web browser, and click Firmware Update. 2. Click Browse, and select flash2.efi; then, click Update. A loader popup window is displayed. 3. When the Confirm Firmware Update window displays, click Continue. A message indicating that the update has completed displays when the update is finished.

To update the firmware from the EFI Shell, complete the following steps:

1. Unzip the file you downloaded, and save all the components of the file package to a valid file system. 2. From the EFI Boot Manager, select EFI Shell [Built-In] , and press Enter. 3. Locate the file system on which the file you downloaded was saved, and type cd fs n : , where n is the file system number where the file is saved.
4. Locate the directory where the file is saved, and go to that directory. 5. Type flash2 , and press Enter. A menu is displayed. 6. Select Update System Firmware , and press Enter. A Warning screen is displayed. 7. Press Enter to continue. The Firmware Update Options Menu is displayed. 8. Select Normal Flash - All Subsystems , and press Enter. Follow the instructions on the screen.

Chapter 3. Diagnostics 39

Page 50 of the IBM 8688 user manual — AMIDiag menus
Seite 50 · Zum Vergrößern klicken
Seite 50
9. Restart the server.

AMIDiag menus

The following figure shows the AMIDiag main menu:

IBM 8688 — AMIDiag menus diagram (page 50)
Abb. 10 · AMIDiag menus

Press the Up Arrow (↑) or Down Arrow (↓) keys to select a menu choice, and press Enter. Press the Right Arrow (→) or Left Arrow (←) keys to display a different AMIDiag menu.

Using AMIDiag keys The following table shows the AMIDiag keys and a brief description of their function.

Esc Halt a currently running test. Exits the AMIDiag program if no test is running.

Enter Run the selected AMIDiag test.

F1 Display Help screens.

F2 Edit batch parameters.

F3 Load batch parameters.

F4 Save batch parameters.

F5 Select or deselect the current test.

F6 Select or deselect the tests on a specific AMIDiag menu.

F7 Select or deselect all AMIDiag tests.

F8 Select or deselect all tests necessary to run a system quick test.

F9 Display a list of the AMIDiag function keys.

F10 Run the selected test or tests.

Key Description

Page 51 of the IBM 8688 user manual — Running AMIDiag tests
Seite 51 · Zum Vergrößern klicken
Seite 51

Running AMIDiag tests

To run this test or test group... Do the following

Run all AMIDiag tests. Press F7, then F10.

Run a complete overall system quick test .

Press F8, then F10.

Run all processor board diagnostic tests. 1. Select System, and press Enter.

2. Press F6, then press F10.

Run all memory diagnostic tests. 1. Select Memory, and press Enter.

2. Press F6, and then press F10.

Run all IDE drive diagnostic tests. 1. Select IDE, and press Enter.

2. Press F6, and then press F10.

Run all USB diagnostic tests. 1. Select USB, and press Enter.

2. Press F6.
3. Press F10.

Run all video diagnostic tests. 1. Select Video, and press Enter.

2. Press F6.
3. Press F10.

Run all serial, expansion port, and ASM diagnostic tests.

1. Select the Misc. menu, and press Enter.
2. Press F6.
3. Press F10.

Enable logging of test session. 1. Select Options, and press Enter.

2. Select Generate Reports , and press Enter.
3. Select the output device, and press Enter. Note: Logging to a file requires a writeable file system to be available from the EFI environment.

Exit the AMIDiag program. Press Esc, and select Yes at the prompt.

Running the AMIDiag program in Batch Mode When your server is experiencing an intermittent problem that no diagnostic software test has been able to identify, run AMIDiag tests over an extended period of time. Many server problems (especially memory problems) are not evident when a test is run only once. You can use the AMIDiag program to run diagnostic tests on only a certain part of the server, a specific part of memory, or a specific part of a disk drive. You can also use the AMIDiag program to build script (.INI) files that contain test configuration information. After you have created an AMIDiag script file, you can run the diagnostic tests listed in the .INI file automatically.

To run the AMIDiag program in batch mode, complete the following steps: 1. Select the AMIDiag tests to be run. 2. Select the test parameters, such as the drives and the I/O ports. These parameters differ for each test. 3. Press F10 to run the tests. 4. Save the current AMIDiag test configuration to a .INI file. You can then run this set of AMIDiag tests at any time.

Chapter 3. Diagnostics 41

Page 52 of the IBM 8688 user manual — System diagnostic tests
Seite 52 · Zum Vergrößern klicken
Seite 52

Error-log viewer If you have enabled logging with the Generate Report option, you can display the log while still running the AMIDiag program. The AMIDiag error log contains all diagnostic errors that the AMIDiag program has found during the current AMIDiag session. The error-log viewer offers some text search capability.

To display the error log, select Display Error Log File on the AMIDiag Options menu. Type the name of the error log file. The default error log filename is amidiag.log. The AMIDiag error log file will be displayed.

If you get a message that says that the log file is damaged, complete the following steps to correct the problem: 1. From the main menu, select Options, and press Enter. 2. Select Generate Report, and press Enter. 3. Select Report Destination, and press Enter.

report. 4. Select File, and press Enter.

To access Help for more information about an error, browse to the error that you want to see in the error window (on the right side of the screen), and press F1.

Quitting tests Press Esc to quit the testing process. Testing stops after any test in progress has been completed.

System diagnostic tests

This section describes individual system diagnostic tests.

codes, see “System-error codes” on page 159.

Processor test Use the processor test to make sure that all microprocessors are functioning properly.

Use the CPU Functionality Test to make sure that microprocessors in the server are operating correctly and efficiently in all address modes. To run the CPU Functionality Test, complete the following steps:

1. From the AMIDiag main menu, select System , and press Enter. 2. Select Processor Test , and press Enter. 3. Select CPU Functionality Test , and press Enter.

Use the CPU Speed Test to check the microprocessor speed. When you run this test, the screen displays the expected processor speed and the actual microprocessor clock speed. To run the CPU Speed Test, complete the following steps: 1. From the AMIDiag main menu, select System, and press Enter. 2. Select Processor Tests, and press Enter. 3. Select CPU Speed Test, and press Enter.

Page 53 of the IBM 8688 user manual — System Board Test
Seite 53 · Zum Vergrößern klicken
Seite 53
4. Set the test parameters: a. Select YES for the CPU Speed Comparison , and press Enter. b. Select Expected CPU Speed , and press Enter.

c. Select Run Test parameters, and press Enter.

To make sure the system configuration is not damaged, complete the following steps: 1. From the AMIDiag main menu, select System, and press Enter. 2. Select Processor Tests, and press Enter. 3. Select CMOS Validity Test, and press Enter.

To make sure that the PCI adapter slots are functioning correctly, complete the following steps: 1. From the AMIDiag main menu, select System, and press Enter.

2. Select Processor Tests , and press Enter. 3. Select PCI Test , and press Enter.

System Board Test Select this choice to run a DMA controller test or a CMOS validity test.

DMA controller test: This test is a series of read and write tests on the memory address registers and page registers of direct memory address (DMA) controllers 1 and 2. The DMA controller manages the flow of information directly to and from system memory and an ″intelligent″ peripheral device, without passing through the microprocessor. On error, the AMIDiag program displays the register number, data written, and data read. To perform this test, complete the following steps: 1. From the main menu, select System, and press Enter. 2. Select DMA Controller Test, and press Enter.

CMOS Validity Test: Use this test to check the validity of the data in CMOS RAM, to make sure that the CMOS RAM checksums are correct, and to make sure that the battery is in good condition. To perform this test, complete the following steps: 1. From the main menu, select System, and press Enter. 2. Select CMOS Validity Test, and press Enter.

PCI System Test Use the PCI System Test to make sure that the PCI bus and all PCI devices in the server are working properly.

Multiprocessor Test Select this test when running the AMIDiag program in a server that has more than one microprocessor. This test performs a variety of diagnostic tests on all microprocessors. To perform this test, select Multiprocessor Test from the System menu, and press Enter. Follow the directions on the screen.

Chapter 3. Diagnostics 43

Page 54 of the IBM 8688 user manual — IDE device diagnostic tests
Seite 54 · Zum Vergrößern klicken
Seite 54

Memory diagnostic tests

Use the memory diagnostic tests to make sure that the memory board and installed memory are properly seated and functioning correctly. You can test all memory and the memory board, or you can isolate a single memory bank to verify that it functions correctly. The following test modes are available: v Quick test runs a single test pattern through the entire free, installed memory space of the banks selected. v Full test runs 18 patterns, including pseudo-random patterns through the entire free, installed memory space of the banks selected.

To run the Quick Memory Test over all memory banks, complete the following steps: 1. From the AMIDiag main menu, select Memory, and press Enter. 2. Select Quick Memory Test, and press Enter. 3. Select All Banks, Quick Test, and press Enter.

To run full diagnostic tests over all memory banks, complete the following steps: 1. From the AMIDiag main menu, select Memory, and press Enter. 2. Select Full Memory Test, and press Enter. 3. Select All Banks, Full Test, and press Enter.

To run the Quick Memory Test over a single memory bank, complete the following steps: 1. From the AMIDiag main menu, select Memory, and press Enter. 2. Select Quick Memory Test, and press Enter.

3. Select the individual bank you want to test or select Bank n , Quick Test, and press Enter.

To run the Full Memory Test over a single memory bank, complete the following steps:

1. From the AMIDiag main menu, select Memory , and press Enter. 2. Select Full Memory Test , and press Enter. 3. Select the individual banks you want to test or select Bank n , Full Test, and press Enter.

IDE device diagnostic tests

The IDE device diagnostic tests work only with CD-ROM, DVD, and removable devices that use the ATAPI interface.

Page 55 of the IBM 8688 user manual — IDE CD-ROM tests
Seite 55 · Zum Vergrößern klicken
Seite 55

IDE CD-ROM tests Use the IDE CD-ROM tests to make sure that the IDE CD-ROM drive is functioning properly. You can test the functionality of the CD-ROM drive tray and the data and audio read functions of the CD-ROM drive. The IDE CD-ROM tests include the following: v IDE CD Tray Test Select this test to make sure that the CD-ROM drive auto-eject feature can eject a CD. The CD tray should open and close. To run the CD tray test for an IDE CD-ROM drive, complete the following steps: 1. From the main menu, select IDE, and press Enter. 2. Select CD Tray Test, and press Enter. v IDE CD Data Test Use the IDE CD data test to make sure that the CD-ROM drive is reading correctly. This test reads all logical blocks on a CD if the starting and ending block are not specified. Place any CD in the CD-ROM drive before running this test, and follow the screen instructions. This test does not play audio CDs. To run the IDE CD data test to diagnose an IDE CD-ROM drive, complete the following steps:

1. From the main menu, select IDE , and press Enter. 2. Select CD Data Test , and press Enter.

v IDE CD Audio Test A speaker must be attached to the CD-ROM drive before running this test. This test plays all logical blocks if the starting and ending block are not specified. To run the IDE CD audio test, complete the following steps: 1. Place an audio CD in the CD-ROM drive. 2. From the main menu, select IDE, and press Enter. 3. Select CD Audio Test, and press Enter.

For the IDE CD test error codes, see “IDE CD test error codes” on page 161.

IDE DVD tests The IDE DVD-ROM drive tests include the following: v IDE DVD Seek Test

Select this test to make sure that the DVD-ROM drive can seek to all sectors of the DVD. You can change the size to seek by adjusting the Block Interleave parameter value. v IDE DVD Read Test Select this test to make sure that the DVD-ROM drive can read to all sectors of the DVD. This test works with both encrypted and unencrypted DVDs.

For the IDE DVD-ROM drive test error codes, see “IDE DVD-ROM drive test error codes” on page 164.

Chapter 3. Diagnostics 45

Page 56 of the IBM 8688 user manual — SCSI diagnostic tests
Seite 56 · Zum Vergrößern klicken
Seite 56

ATAPI removables test This test verifies that the removable disk drive, such as an Iomega ZIP drive, is operating correctly. The tests include: v Format test The format test verifies that the removable drive is properly formatted for operation. Attention: This test formats the media in the device being tested. Use this test only if you want to format the media. v Write test This test verifies the ability of the removable disk drive to write data correctly to a disk. Use a disk that you know is good for this test. This test is normally hidden from view because it erases the data on the disk. To make this menu item viewable so that you can run this test, complete the following steps: 1. From the AMIDiag main menu, select Options, and press Enter.

2. Select Toggle Hidden Test Display , and press Enter.
3. Select the drive or drives to be tested, and run the test.

v Read test Use this test to verify the ability of the removable media drive to read data correctly in both block and random sequential format from a removable disk. Use a disk that you know is good for this test. Select the drive or drives to be tested, and run the test. You can select the starting and ending clocks of data to be read, or you can select the percentage of the drive to be read in a sequential or random order. You can also run a random or sequential read test. v Seek test Use this test to verify the ability of the removable media drive to seek blocks of data sequentially or randomly. Select the test parameters, and run the test. You can specify the number of times this test is to be run (repeat count), or you can specify Quick Test to test only 1% of the disk. v Eject test Use this test to verify that the auto-eject feature of the removable media drive is working properly. You can set the Execution Count parameter to run this test a number of times. Select the test parameters, and select Continue to run the test.

For the ATAPI removables test error codes, see “ATAPI removables test error codes” on page 162.

SCSI diagnostic tests

The AMIDiag program tests all SCSI devices installed in your server. The SCSI tests detect and test a combination of up to 120 SCSI hard disk drives.

SCSI diagnostic tests consists of the following tests: v SCSI Disk Buffer Test

v SCSI Disk Self Diagnostic Test v SCSI Disk Read Test v SCSI Disk Write Test v SCSI Disk Format Test v SCSI Disk Spin Down Test

v SCSI Disk Quick Test

Page 57 of the IBM 8688 user manual — SCSI Disk Buffer Test
Seite 57 · Zum Vergrößern klicken
Seite 57

For the SCSI test error codes, see “SCSI test error codes” on page 164.

SCSI Disk Buffer Test This test writes logical blocks of data to the internal buffer on the disk drive. The same logical blocks of data are then read from the drive buffer and compared to the original data. If the SCSI hard disk drive does not have an internal buffer, you cannot select this test.

SCSI Disk Self Diagnostic Test Select this choice to run the diagnostic tests on the SCSI disk drive.

To run the test, complete the following steps: 1. Select SCSI Disk Self Diagnostic Test, and press Enter. 2. Choose the parameters on the screen, and select Continue.

the entire disk self test completes.

SCSI Disk Read Test Use this test to make sure that the SCSI drive is reading correctly. This test sequentially and randomly reads logical blocks from the SCSI hard disk drive. If you do not specify a starting and ending block number, block 0 through the last block are tested.

To run the SCSI disk read test, complete the following steps: 1. From the main menu, select SCSI, and press Enter.

2. Select SCSI Disk Read Test , and press Enter. A default parameter screen appears.
IBM 8688 — SCSI Disk Buffer Test diagram (page 57)
Abb. 11 · SCSI Disk Buffer Test

Chapter 3. Diagnostics 47

Page 58 of the IBM 8688 user manual — SCSI Disk Write Test
Seite 58 · Zum Vergrößern klicken
Seite 58
3. Set the parameters that you want.

overall % Specifies the drivewise % or common % as set for each drive. If Drivewise is selected, the drive parameters are specified for each drive used. If Common is selected, all drive parameters use the % parameters, which are entered in the % for Common fields. This reduces the need to set each drive parameter if the server has a large number of drives.

CommonUse the term % to specify all drives

SCSI Disk n Specify an individual drive parameter.

4. Select Continue , and press Enter.

The start and end block number fields are 0 and the last block on the disk or the values set the last time this test was run. As the test runs, the current block number, number of blocks tested, and number of blocks left are updated. Also, the block tested is marked with a different character. The random test is performed on the specified percentage of blocks between the specified start and end blocks.

SCSI Disk Write Test Use this test to verify the ability of the SCSI disk drive to write data correctly to a disk. Use a disk that you know is good for this test. This test is normally hidden from view because it erases the data on the disk. To make this menu item viewable so that you can run this test, complete the following steps: 1. From the AMIDiag main menu, select Options, and press Enter. 2. Select Toggle Hidden Test Display, and press Enter.

3. Select the drive or drives to be tested, and run the test.

SCSI Disk Format Test Use this test to verify that the SCSI device is properly formatted for operation. This test is normally hidden from view because it erases the data on the disk. To make this menu item viewable so that you can run this test, complete the following steps: 1. From the AMIDiag main menu, select Options, and press Enter. 2. Select Toggle Hidden Test Display, and press Enter.

SCSI Disk Spin Down Test This test issues a spin down command to the disk being tested.

SCSI Disk Quick Test Use this test to perform an abbreviated read test on all SCSI disks installed in the server.

Parameter Description

Page 59 of the IBM 8688 user manual — : YES : 000000000 : 002028000
Seite 59 · Zum Vergrößern klicken
Seite 59

SCSI CD-ROM tests Use the SCSI CD-ROM tests to diagnose SCSI CD-ROM drive functions. SCSI CD-ROM tests include the following subtests: v SCSI CD-ROM Buffer Test Use this diagnostic test to make sure that the memory buffer on the CD-ROM drive is working correctly. v SCSI CD-ROM Self Test Select this choice to run the diagnostic tests on the disk.

To run the test, complete the following steps: 1. From the main menu, select SCSI, and press Enter.

2. Select SCSI CD-ROM Self Diagnostics Test , and press Enter. 3. Select the parameters on the screen; then, select Continue , and press Enter.

Note: You cannot quit this test. You must wait until the entire test completes. v SCSI CD-ROM Tray Test Select this test to make sure that the CD-ROM drive auto-eject feature can eject a CD. The CD tray should open and close. To test the CD-ROM drive tray, complete the following steps: 1. From the main menu, select SCSI, and press Enter. 2. Select SCSI Tray Test, and press Enter.

v SCSI CD-ROM Read Test Select this test to make sure that the CD-ROM drive can read to all sectors of the CD. This test supports multi-format CDs with data and audio tracks, but it fails if an audio CD is placed in the drive. To run the SCSI CD-ROM Read test, complete the following steps: 1. From the main menu, select SCSI, and press Enter. 2. Select SCSI CD-ROM Read Test, and press Enter. A parameter screen appears:

100 Select SCSI Disk Select SCSI Disk Overall % Parameters 100 SCSI Disk 0 CONTINUE

Overall % Parameters SCSI Disk 0 CONTINUE

overall % Specifies drivewise % as set for each drive.

CommonUse the term % to specify all drives

SCSI CD-ROM n Specify an individual drive parameter.

SCSI CD-ROM Read Test

SCSI CD-ROM Read Test

Test CDROM0 Start Block End Block Sequential Test Random Test CONTINUE

: YES : 000000000 : 002028000

Test CDROM0 Start Block End Block Sequential Test Random Test CONTINUE

: YES : 000000000 : 002028000

Chapter 3. Diagnostics 49

Parameter Description

Page 60 of the IBM 8688 user manual — : YES : 000000000 : 020280000
Seite 60 · Zum Vergrößern klicken
Seite 60

In the Sequential Test or Random Test, you are prompted for the percentage of the drive to be tested.

Sequential TestYES % to test : 100 CONTINUE

Sequential Test % to test CONTINUE

: YES : 100

If the starting and ending block are not specified, this test reads from block 0 to the last block. The random test is performed on the specified blocks between the start and end blocks. 3. Choose a percentage, select CONTINUE, and press Enter. v SCSI CD-ROM Play Test Use this test to make sure that the CD-ROM drive can play audio CDs. To run the SCSI CD-ROM Play test, complete the following steps: 1. Attach a speaker to the CD-ROM drive, and insert an audio CD in the CD-ROM drive. 2. From the main menu, select SCSI, and press Enter. 3. Select SCSI CD-ROM Play Test, and press Enter. A default parameter screen appears:

100 Select SCSI Disk Select SCSI Disk Overall % Parameters 100 SCSI Disk 0 CONTINUE

Overall % Parameters SCSI Disk 0 CONTINUE

overall % Specifies drivewise % as set for each drive.

CommonUse the term % to specify all drives

SCSI CD-ROM n Specify an individual drive parameter.

The following appears if you specify an individual drive:

SCSI CD-ROM Play Test

SCSI CD-ROM Play Test

Test CDROM0 Start Block End Block CONTINUE

Test CDROM0 Start Block End Block CONTINUE

: YES : 000000000 : 020280000

: YES : 000000000 : 020280000

SCSI Tape Test Use the SCSI Tape Test to diagnose functions of a SCSI tape device. The SCSI Tape tests include the following: v SCSI Tape Buffer Test This test writes logical blocks of data to the internal buffer on the tape drive. The same logical blocks of data are then read from the tape drive buffer and compared to the original data. If the tape drive does not have an internal buffer, you cannot select this test. v SCSI Tape Read Test Use this test to make sure that the SCSI tape drive is reading correctly. This test reads sequential logical blocks from the SCSI tape. With default parameters, this

Sequential Test · Sequential Test · Parameter Description

Page 61 of the IBM 8688 user manual — Video diagnostic tests
Seite 61 · Zum Vergrößern klicken
Seite 61

test requires fully written media to be installed in the device being tested. Partially written media will result in a read error at the end of data. If only blank media is available, use the SCSI Tape Write Test to write a test pattern onto the blank media. To run the SCSI Tape Read Test, complete the following steps: 1. From the main menu, select SCSI, and press Enter. 2. Select SCSI Tape Read Test, and press Enter. A default parameter screen appears:

100 Select SCSI Disk Select SCSI Disk Overall % Parameters 100 SCSI Disk 0 CONTINUE

Overall % Parameters SCSI Disk 0 CONTINUE

overall % Specifies drivewise % as set for each drive.

CommonUse the term % to specify all drives

SCSI Tape n Specify an individual drive parameter.

The following screen appears when you specify an individual drive:

SCSI Tape Read Test

SCSI Tape Read Test

Test Tape 0 Start Block End Block CONTINUE

Test Tape 0 Start Block End Block CONTINUE

: YES : 000000000 : 002028000

: YES : 000000000 : 002028000

A prompt for the percentage of the drive to be tested appears. 3. Specify the percentage of the drive to be tested, select CONTINUE, and press Enter. If the tape is not positioned at the beginning of the starting block, a tape rewind command is issued before the test begins.

v SCSI Tape Rewind Test Use this test to make sure that the SCSI tape drive can rewind a tape. To run the SCSI tape rewind test, complete the following steps.

v SCSI Tape Write Test Use this test to verify the ability of the SCSI tape drive to write data correctly to a tape. Use a tape that you know is good for this test. This test is normally hidden from view because it erases the data on the tape. Select the tape drives to be tested, and run the test. Attention: This test erases all data on the disk.

Video diagnostic tests

Select this choice to run diagnostic tests on the display and the video controller.

Chapter 3. Diagnostics 51

Parameter Description

Page 62 of the IBM 8688 user manual — Running video tests
Seite 62 · Zum Vergrößern klicken
Seite 62

To diagnose video display problems, complete the following steps: 1. From the main menu, select Video, and press Enter. 2. Select Video Memory Test, and press Enter.

For the video test error codes, see “Video test error codes” on page 167.

Running video tests The video test you run depends on the type of monitor installed on your server.

Video Monitor Test These tests verify the video controller output in addition to the communication between the controller and the display device.

Attribute Test: Use this test to make sure that the video display attributes, such as blinking, bold, and reverse video, are working correctly. You can run this test on all monochrome and all color monitors.

To run the attribute test, complete the following steps:

1. From the main menu, select Video , and press Enter. 2. Select Attribute Test , and press Enter.

Color Test: This test displays the possible colors in foreground, background, and border. You can run this test on all color monitors.

Text Mode Test: Use the Text Mode test to make sure that text displays correctly. The text mode tests are shown on the following table:

Test Name Test Description Type of Monitor

80 x 25 Display Test Tests the 80 x 25 character set of the display adapter, displaying the entire character set in black and white, then in reverse video in video mode 3 (mode 7 if monochrome).

All monochrome and all color monitors.

40 x 25 Display Test Tests the 40 x 25 character set of the display adapter in black and white, displaying the entire character set in black and white, then in reverse video.

All monochrome and all color monitors.

Graphics mode tests: Use the graphics mode tests to make sure that graphics display correctly. The following subtests appear in all Graphics Mode Tests (320 x 200, 640 x 200, 640 x 350, 640 x 480):

Text and Attribute Test Makes sure all characters are displayed in the proper color.

Grid Test Verifies the graphic dot spacing for each mode.

Aspect Ratio and Display Centering

Centers the monitor display.

Circular Pattern Test Centers the monitor display.

Resolution Reports the screen resolution.

Animation and Flicker Reports the video controller speed.

Subtest Description

Page 63 of the IBM 8688 user manual — USB diagnostic tests
Seite 63 · Zum Vergrößern klicken
Seite 63

Pixel Throughput Reports the speed at which complex patterns are drawn on the screen.

These video tests might not appear correctly when displaying high-resolution VESA video modes on a multisync monitor. The monitor must be adjusted for each individual video mode. After the video mode you will be using appears, you must run the Aspect Ratio and Display Centering subtest to center the monitor.

The graphics mode tests are:

Test Name Test Description Type of Monitor

320 x 200 Graphics Test

Displays a black and white 9 x 13 window and redisplays it in reverse video. Then displays a three-color screen, a screen of random colors, then a black and white screen, and finally 256 colors

All color monitors.

640 x 200 Graphics Test

Displays three black and white boxes, then goes from a black screen to a white screen, and back to a black screen.

640 x 350 Graphics Test

Displays a 16-color screen, then fills the screen with random colors, then returns to a blank screen.

EGA and VGA adapters only.

640 x 480 Graphics Test

Displays a 16-color screen, then fills the screen with random colors, then returns to a blank screen.

Only VGA adapters.

Video Controller Test This test verifies the functionality of the graphics controller in VGA mode. The video controller test verifies vertical synchronization, horizontal synchronization, the graphics controller, the attribute controller, and the DAC register.

USB diagnostic tests

The USB tests diagnose problems with USB devices.

For the USB test error codes, see “USB test error codes” on page 167.

USB Functionality Test Select USB Test from the USB menu to diagnose problems with USB devices and to make sure that USB support is provided in the SAL/EFI.

USB Keyboard Test Use this test to diagnose USB keyboard hardware functionality and to determine the data transfer rate between the USB host controller and the USB keyboard. This procedure tests the USB keyboard key codes and keystrokes.

Chapter 3. Diagnostics 53

Subtest Description · All color monitors

Page 64 of the IBM 8688 user manual — 8 09 38 9 0A 39
Seite 64 · Zum Vergrößern klicken
Seite 64

To run the test, complete the following steps: 1. Select Device Test from the USB menu, and press Enter. 2. Select USB Keyboard Test, and press Enter.

The following test parameters appear:

Test This Device To run the USB Keyboard Test, select YES, and press Enter.

PnP Test Select YES to run the USB Keyboard Plug and Play (PnP) Test. This test makes sure that the USB keyboard Plug and Play feature works properly. The Plug and Play feature automatically configures the USB device when the device is attached to the server.

USB Keyboard Control TestTo test the USB keyboard controller, complete the following steps:
1. Select USB from the main menu, and press Enter. 2. Select USB Keyboard Test , and press Enter. 3. Select USB Keyboard Control Test , and press Enter.

USB Keyboard Code Test: The USB Keyboard Code test determines if a pressed key matches the Scan and ASCII codes for that key. Every time you press a key to verify its code, both the scan code and ASCII code of the pressed key is displayed. The key symbol is also displayed.

Perform this test to identify faulty keys.

To run the test, complete the following steps: 1. Select USB from the main menu, and press Enter. 2. Select USB Keyboard Test, and press Enter. 3. Select USB Keyboard Code Test, and press Enter to display a keyboard layout. Scan code and ASCII code appear above the keyboard layout.

4. Press the keys on the keyboard. The scan codes and ASCII codes display in the appropriate fields for each key as it is pressed. Use this test to verify the codes with their respective keys. Use the tables on pages 54 through 59 for the correct scan and ASCII codes. 5. Press Ctrl+Break to exit this test.

Use the following tables to verify that the displayed scan and ASCII codes are correct.

Table 3. Lower case keyboard scan/ASCII codes

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

Esc 01 1B 1 02 31

2 03 32 3 04 33

4 05 34 5 06 35

6 07 36 7 08 37

8 09 38 9 0A 39

0 0B 30 - 0C 2D

= 0D 3D Backspace 0E 08

Tab 0F 09 q 10 71

Parameter Action

Page 65 of the IBM 8688 user manual — + 4E 00 4F 00
Seite 65 · Zum Vergrößern klicken
Seite 65

Table 3. Lower case keyboard scan/ASCII codes (continued)

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

w 11 77 e 12 65

r 13 72 t 14 74

y 15 79 u 16 75

i 17 69 o 18 6F

p 19 70 [ 1A 5B

} 1B 5D Return 1C 0D

Ctrl ‡ ‡ a 1E 61

s 1F 73 d 20 64

f 21 66 g 22 67

h 23 68 j 24 6A

k 25 6B l 26 6C

; 27 3B ’ 28 27

’ 29 60 Shift ‡ ‡

\ 2B 5C z 2C 7A

x 2D 78 c 2E 63

v 2F 76 b 30 62

n 31 6E m 32 6D

, 33 2C . 34 2E

/ 35 2F * 37 2A

Alt ‡ ‡ Space 39 20

Caps Lock ‡ ‡ F1 3B 00

F2 3C 00 F3 3D 00

F4 3E 00 F5 3F 00

F6 40 00 F7 41 00

F8 42 00 F9 43 00

F10 44 00 F11 85 00

F12 86 00 Num Lock ‡ ‡

Scroll Lock ‡ ‡ Home 47 00

48 00 PgUp 49 00

_ 4A 2D 4B 00

Center key 4C 00 4D 00

+ 4E 00 4F 00

50 00 PgDn 51 00

Ins 52 00 Del 53 00

SysReq no key no key Key 45 56 5C

Enter E0 0D / E0 2F

Print Screen ‡ ‡ Pause ‡ ‡

Home 47 E0 48 E0

PgUp 49 E0 4B E0

Chapter 3. Diagnostics 55

Page 66 of the IBM 8688 user manual — Z 2C 5A X 2D 58
Seite 66 · Zum Vergrößern klicken
Seite 66

Table 3. Lower case keyboard scan/ASCII codes (continued)

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

‡ Combination provides no keystroke for the application; performs another action.

-- No function is assigned to this combination.

Table 4. Upper case (shift) keyboard scan/ASCII codes

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

Shift+Esc 01 1B ! 02 21

@ 03 40 # 04 23

$ 05 24 % 06 25

^ 07 5E & 08 26

* 09 2A ( 0A 28

) 0B 29 _ 0C 5F

+ 0D 2B Shift+ Backspace

0E 08

Shift+Tab 0F 00 Q 10 51

W 11 57 E 12 45

R 13 52 T 14 54

Y 15 59 U 16 55

I 17 49 O 18 4F

P 19 50 { 1A 7B

} 1B 7D Shift+Return 1C 0D

Shift+Ctrl ‡ ‡ A 1E 41

S 1F 53 D 20 44

F 21 46 G 22 47

H 23 48 J 24 4A

K 25 4B L 26 4C

: 27 3A ″ 28 22

~ 29 7e | 2B 7C

Z 2C 5A X 2D 58

C 2E 43 V 2F 56

B 30 42 N 31 4E

M 32 4D < 33 3C

> 34 3E ? 35 3F

* 37 2A Shift+Alt ‡ ‡

Shift+Space 39 20 Shift+Caps

Shift+F1 54 00 Shift+F2 55 00

Shift+F3 56 00 Shift+F4 57 00

Shift+F5 58 00 Shift+F6 59 00

Shift+F7 5A 00 Shift+F8 5B 00

Shift+F9 5C 00 Shift+F10 5D 00

‡ ‡ · Lock

Page 67 of the IBM 8688 user manual — Video Controller Test
Seite 67 · Zum Vergrößern klicken
Seite 67

Table 4. Upper case (shift) keyboard scan/ASCII codes (continued)

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

Shift+F11 87 00 Shift+F12 88 00

Shift+7 47 37 Shift+8 48 38

Shift+9 49 39 Shift+ - 4A 2D

Shift+4 4B 34 Shift+5 4C 35

Shift+6 4D 36 Shift++ 4E 2B

Shift+1 4F 31 Shift+2 50 32

Shift+3 51 33 Shift+0 52 30

Shift+. 53 2E Shift+Sys

no key no key

Shift+key 45 56 7C Shift+Enter E0 0D

Shift+/ E0 2F Shift+Print

Shift+Pause ‡ ‡ Shift+Home 47 E0

Shift 48 E0 Shift+PgUp 49 E0

Shift 4B E0 Shift 4D E0

Shift+End 4F E0 Shift 50 E0

Shift+PgDn 51 E0 Shift+Ins 52 E0

‡ Combination provides no keystroke for the application; performs another action.

-- No function is assigned to this combination.

Table 5. Ctrl keyboard ASCII/scan codes

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

Ctrl+Esc 01 1B Ctrl+1 -- --

Ctrl+2 (NUL) 03 00 Ctrl+3 -- --

Ctrl+4 -- -- Ctrl+5 -- --

Ctrl+6 (RS) 07 1E Ctrl+7 -- --

Ctrl+8 -- -- Ctrl+9 -- --

Ctrl+0 -- -- Ctrl+_ 0C 1F

0E 7F Ctrl+Tab 94 00

Ctrl+Tab 0F 00 Ctrl+Q 10 51

Ctrl+q (DC1) 10 11 Ctrl+w (ETB) 11 17

Ctrl+e (ENQ) 12 05 Ctrl+r (DC2) 13 12

Ctrl+t (DC4) 14 14 Ctrl+y (EM) 15 19

Ctrl+u (NAK) 16 15 Ctrl+i (HT) 17 9

Ctrl+o (SI) 18 0F Ctrl+p (DLE) 19 10

Ctrl+[ (ESC) 1A 1B Ctrl+] (GS) 1B 1D

Chapter 3. Diagnostics 57

Show 11 more labels / short text on this page
Shift+Num · ‡ ‡ Shift+Scroll · ‡ ‡ · Lock · Lock · Req · ‡ ‡ · Screen · Shift+Del 53 E0 · Ctrl+ Backspace · (Del)
Page 68 of the IBM 8688 user manual — Video Controller Test
Seite 68 · Zum Vergrößern klicken
Seite 68

Table 5. Ctrl keyboard ASCII/scan codes (continued)

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

Ctrl+Return 1C 0A Ctrl+a 1E 01

Ctrl+s (DC3) 1F 13 Ctrl+d (EOT) 20 04

Ctrl+f (ACK) 21 06 Ctrl+g (BEL) 22 07

23 08 Ctrl+j (LF) 24 0A

Ctrl+k (VT) 25 0B Ctrl+1 26 0C

Ctrl+; -- -- Ctrl+’ -- --

Ctrl+` -- -- Ctrl+Shift ‡ ‡

Ctrl+\ (FS) 2B 1C Ctrl+z (SUB) 2C 1A

Ctrl+x (CAN) 2D 18 Ctrl+c (ETX) 2E 03

Ctrl+v (SYN) 2F 16 Ctrl+b (STX) 30 02

Ctrl+n (SO) 31 0E Ctrl+m (CR) 32 0D

Ctrl+. -- -- Ctrl+. -- --

Ctrl+/ -- -- Ctrl+* 96 00

Ctrl+Alt ‡ ‡ Ctrl+Space 39 20

-- -- Ctrl+F1 5E 00

Ctrl+F2 5F 00 Ctrl+F3 60 00

Ctrl+F4 61 00 Ctrl+F5 62 00

Ctrl+F6 63 00 Ctrl+F7 64 00

Ctrl+F8 65 00 Ctrl+F9 66 00

Ctrl+F10 67 00 Ctrl+F11 89 00

Ctrl+F12 8A 00 Ctrl+Num

-- -- Ctrl+Hme 77 00

Ctrl 8D 00 Ctrl+PgUp 84 00

Ctrl+Keypad - 8E 00 Ctrl 73 00

Ctrl+Center 8F 00 Ctrl 74 00

90 00 Ctrl+End 75 00

Ctrl 91 00 Ctrl+PgDn 76 00

Ctrl+Ins 92 00 Ctrl+Del 93 00

Ctrl+Sys Req (no key) (no key) Ctrl+Key 45 -- --

Ctrl+Enter E0 Ctrl+/ 95 00

72 00 Ctrl+Break 00 00

Ctrl+Home 77 E0 Ctrl 8D E0

Ctrl+PgUp 84 E0 Ctrl 73 E0

Ctrl 74 E0 Ctrl+End 75 E0

Ctrl 91 E0 Ctrl+PgDn 76 E0

Ctrl+Ins 92 E0 Ctrl+Del 93 E0

Show 10 more labels / short text on this page
Ctrl+h (Backspace) · Ctrl+Caps · Lock · Lock · Ctrl+Scroll · Lock · Ctrl+Keypad · + · Ctrl+Print · Screen
Page 69 of the IBM 8688 user manual — 0E 00
Seite 69 · Zum Vergrößern klicken
Seite 69

Table 5. Ctrl keyboard ASCII/scan codes (continued)

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

‡ Combination provides no keystroke for the application; performs another action.

-- No function is assigned to this combination.

Table 6. Alt keyboard scan/ASCII codes

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

Alt+Esc 01 00 Alt+1 78 00

Alt+2 79 00 Alt+3 7A 00

Alt+4 7B 00 Alt+5 7C 00

Alt+6 7D 00 Alt+7 7E 00

Alt+8 7F 00 Alt+9 80 00

Alt+0 81 00 Alt+ - 82 00

Alt+= 83 00 Alt+ Backspace

0E 00

Alt+Tab A5 00 Alt+q 10 00

Alt+w 11 00 Alt+e 12 00

Alt+r 13 00 Alt+t 14 00

Alt+y 15 00 Alt+u 16 00

Alt+I 17 00 Alt+o 18 00

Alt+p 19 00 Alt+[ 1A 00

Alt+] 1B 00 Alt+Return 1C 00

Alt+Ctrl ‡ ‡ Alt+a 1E 00

Alt+s 1F 00 Alt+d 20 00

Alt+f 21 00 Alt+g 22 00

Alt+h 23 00 Alt+j 24 00

Alt+k 25 00 Alt+l 26 00

Alt+; 27 00 Alt+’ 28 00

Alt+` 29 00 Alt+Shift ‡ ‡

Alt+\ 2B 00 Alt+z 2C 00

Alt+x 2D 00 Alt+c 2E 00

Alt+v 2F 00 Alt+b 30 00

Alt+n 31 00 Alt+m 32 00

Alt+, 33 00 Alt+. 34 00

Alt+/ 35 00 Alt+* 37 00

Alt+Space 39 00 Alt+Caps

Alt+F1 68 00 Alt+F2 69 00

Alt F3 6A 00 Alt+F4 6B 00

Alt+F5 6C 00 Alt+F6 6D 00

Alt+F7 6E 00 Alt+F8 6F 00

Alt+F9 70 00 Alt+F10 71 00

Chapter 3. Diagnostics 59

‡ ‡ · Lock

Page 70 of the IBM 8688 user manual — Miscellaneous diagnostic tests
Seite 70 · Zum Vergrößern klicken
Seite 70

Table 6. Alt keyboard scan/ASCII codes (continued)

Keystroke Scan Code ASCII Code Keystroke Scan Code ASCII Code

Alt+F11 7B 00 Alt+F12 8C 00

Alt+Num Lock ‡ ‡ Alt+Scroll

Alt+Keypad - 4A 00 Alt+Keypad + 4E 00

# 00 Alt+Del -- --

Alt+SysReq (no key) (no key) Alt+key 45 -- --

Alt+Enter A6 00 Alt+/ A4 00

‡ ‡ Alt+Pause ‡ ‡

Alt+Home 97 00 Alt 98 00

Alt+PgUp 99 00 Alt 9B 00

Alt 9D 00 Alt+End 9F 00

Alt A0 00 Alt+PgDn A1 00

Alt+Ins A2 00 Alt+Del A3 00

‡ Combination provides no keystroke for the application; performs another action.

-- No function is assigned to this combination.

USB Mouse Test Select the USB Mouse Test to test the USB mouse on your server.

To run the test, complete the following steps: 1. From the main menu, select USB, and press Enter. 2. Select Device Test, and press Enter.

3. Select USB Mouse Test , and press Enter.

Test This Device Select YES to run the USB Mouse Test.

Sensitivity Test Select YES to run the Sensitivity test.

PnP Test Select YES to run the USB Mouse Plug and Play (PnP) test. This test makes sure that the USB mouse Plug and Play feature works properly. The Plug and Play feature automatically configures the USB device when the device is attached to the server.

Miscellaneous diagnostic tests

The Miscellaneous diagnostic tests include the Serial Port Test, the LED Test, the RXE Port Test, and the Advanced System Management Test.

Serial port test The Serial Port test checks to see if the serial port is functioning properly.

To diagnose serial port problems, complete the following steps:

1. From the main menu, select Miscellaneous , and press Enter. 2. Select Serial Port Test , and press Enter.
Show 7 more labels / short text on this page
‡ ‡ · Lock · Alt+Keypad · Numbers · Alt+Print · Screen · Parameter Action
Page 71 of the IBM 8688 user manual — LED Test
Seite 71 · Zum Vergrößern klicken
Seite 71

The test routines check all serial port controllers at speeds from 300 to 115,200 bps (up to 460,800 bps if a 16550 UART is installed). 3. Select the number of data bits, number of stop bits, and parity type for the serial port. 4. Select a field using the – and + keys and set the parameters. 5. Select Continue, and press Enter.

The serial port tests include the following: v Serial Port Hardware Test The serial port hardware test diagnoses hardware attached to the serial port. v Internal Loopback Test

This test verifies the proper functionality of the transmitter and receiver register in the serial port using the internal loopback mechanism. Attention: Running this test with console redirection might slow down the server. v External LoopBack Test

This test verifies the proper functionality of the transmitter and receiver register in the serial port. This test requires an external loopback connector to be physically connected to the serial port. Attention: Running this test with console redirection might slow down the server.

v FIFO Test This test verifies that the first-in first-out (FIFO) function in the serial port is functioning properly. This test is enabled only for UART 16550 and above. v Baud Rate Test

This test verifies the accuracy of the data being transferred by the serial port at different baud rates.

For the serial port test error codes, see “Serial port test error codes” on page 169.

LED Test Use this test to diagnose all LEDs that can be set using software and visible after the server is assembled. This test lights all LEDs in the server and prompts you to check that they are all lit; then, it turns off all LEDs and prompts you to check that they have been turned off.

RXE Port Test Use this test to diagnose problems with the RXE ports. The RXE Port Test consists of the following sub-tests:

v RIOG (RXE) Status This test displays the status of the RXE ports and the attached RXE-100 units. v RIOG Port A Test This test verifies the quality of the connection from the RXE Expansion Port (A) connector to a remote I/O enclosure. v RIOG Port B Test This test verifies the quality of the connection from the RXE Expansion Port (B) connector to a remote I/O enclosure. v RXE-100 Side A Port Test This test verifies the quality of the connection from the RXE-100 Side A connector to the RXE Expansion Port.

Chapter 3. Diagnostics 61

Page 72 of the IBM 8688 user manual — Advanced System Management Test
Seite 72 · Zum Vergrößern klicken
Seite 72

v RXE-100 Side A →Side B Test This test verifies the quality of the connection from the RXE-100 Side A to the RXE-100 Side B. v RXE-100 Side B →Side A Test This test verifies the quality of the connection from the RXE-100 Side B to the RXE-100 Side A. v RXE-100 Side B Port Test This test verifies the quality of the connection from the RXE-100 Side B Port connector to the RXE Expansion Port.

Advanced System Management Test The Advanced System Management (ASM) Test consists of the following sub-tests: v ASM/ISMP I2C Bus Test This test queries the status of the I2C subsystem within the x450 node. It reports back on any internal integrated circuit (I2C) radials that either are untested or tested bad. v ASM Built-In Self Test (BIST) This test queries the ASM for the status of its last-run BIST. Non-disruptive portions of BIST are run periodically on the ASM adapter. Failing BIST results will be reported so that you can determine which, if any, of the major subsystems of the ASM adapter are malfunctioning. v ASM Restart Test Use this test to restart the ASM adapter without disconnecting ac power from the xSeries 450 server.

v RXE I2C Bus Test This test queries the status of the I2C subsystem within attached RXE-100 units. It reports back on any I2C radials that are either untested or tested bad.

unit using the RS-485 bus and appropriate Category 3 and Category 5 cables with proper termination. v RXE ISMP Self Test

This test queries the ISMP controllers of attached RXE-100 units for the last BIST status. Failing RXE-100 BIST results will be reported so that you can determine if the ISMP subsystem is malfunctioning due to microcontroller problems.

unit using the RS-485 bus and appropriate Category 3 and Category 5 cables with proper termination.

Page 73 of the IBM 8688 user manual — Options menu
Seite 73 · Zum Vergrößern klicken
Seite 73

Options menu

The Options menu items are as follows:

IBM 8688 — Options menu diagram (page 73)
Abb. 12 · Options menu

Edit Batch Parameters You can customize a set of diagnostic tests to run on your server and save it as a batch file to be run later. You can set the type of AMIDiag test to be run, the number of times each test is run, and the test parameters (for example, you can specify the starting and ending hard disk drive heads and cylinders to be tested).

To set or display AMIDiag runtime parameters, complete the following steps:

1. From the AMIDiag main menu, select Options , and press Enter. 2. Select Edit Batch Parameters , and press Enter. The Edit Batch Parameters menu appears:
IBM 8688 — Options menu diagram (page 73)
Abb. 13 · Options menu

Chapter 3. Diagnostics 63

Page 74 of the IBM 8688 user manual — Options menu
Seite 74 · Zum Vergrößern klicken
Seite 74
3. Select Batch Parameters , and press Enter. The following menu is displayed:

Specifies the number of test cycle scripts in the file. In each cycle there can be a different set of test parameters.

Specifies whether to test through all of the cycles or just one cycle. This field can be set to All or One.

The Test mode refers to the overall control, not individual cycles. The test modes are:

Continuous The specified tests run until Esc or Ctrl+Break is pressed.

Timebound Specify how long the test is to run. Type the hours in the Time Limit Hrs field and the minutes in the Time Limit Min field, and press Enter. The maximum setting for number of hours is 999. The maximum setting for number of minutes is 59.

Passbound Set the number of passes (up to 65,535) for the selected AMIDiag tests in the Number of Passes field, or press Enter to accept the default (run each selected diagnostic test once).

Specifies the time period in hours in case of cycle Timebound test mode.

Specifies the time period in minutes in case of cycle Timebound test mode.

Specifies the number of passes of cycles in case of Passbound test mode.

Break All on Error

This field can be set to YES or NO. If set to YES, the AMIDiag program stops running all tests after it finds an error.

Show 7 more labels / short text on this page
Cycle Mode · Cycle Number · Test Mode · Mode Description · Test Limit Hrs · Test Limit Min · Number of Passes
Page 75 of the IBM 8688 user manual — Options menu
Seite 75 · Zum Vergrößern klicken
Seite 75

Specifies the test mode in a cycle. The cycle test modes are:

Timebound Specify how long the test is to run. Type the hours in the Time Limit Hrs field and the minutes in the Time Limit Min field, and press Enter. The maximum setting for the number of hours is 999. The maximum setting for the number of minutes is 59.

Passbound Set the number of passes (up to 65,535) for the selected AMIDiag tests in the Number of Passes field, or press Enter to accept the default (run each selected diagnostic test once).

Specifies the time period in hours in case of Timebound test mode.

Specifies the time period in minutes in case of Timebound test mode.

Specifies the number of passes in a cycle, in case of cycle Passbound test mode. Individual tests also have a count specifying how many times they are to be run.

The test order parameters are:

Default The selected AMIDiag tests are run in exactly the same order in which they were selected.

Random The selected AMIDiag tests are run in a random manner.

Testwise The selected AMIDiag tests are run in the order in which they appear on the AMIDiag menus.

This field can be set to YES or NO. If set to YES, the AMIDiag program waits for you to press any key after finding every error.

Break Test on Error

This field can be set to YES or NO. If set to YES, the AMIDiag program stops running after it finds an error.

Select this parameter to run the interactive tests in interactive mode. Your input is required in an interactive test. The default value for this parameter is No.

If this parameter is set to NO, all diagnostic tests that support the interactive flag and cannot be run without your input will not run. If the test can be run without your input but it is impossible to decide if the test has passed or failed without your input, the test will run, but it will always pass.

If this parameter is set to YES and the test cannot be run without your input, it runs and will wait for your input as appropriate. If the test can be run without your input but it is impossible to decide if the test has passed or failed without your input, the test runs and it will wait for your decision whether the test passed.

This parameter specifies that tests must be run in quick test mode.

Chapter 3. Diagnostics 65

Show 10 more labels / short text on this page
Cycle Test Mode · Mode Description · Cycle TLimit Hrs · Cycle TLimit Min · Passes in Cycle · Test Order · Parameter Description · Wait on Error · Interactive · Quick test
Page 76 of the IBM 8688 user manual — Options menu
Seite 76 · Zum Vergrößern klicken
Seite 76

Abbreviated versions of the diagnostic tests are run in quick test mode. The selected tests are run in quick test mode if the tests support quick mode. You can use the quick test parameter in two ways:

Quick Test use Description

Complete a system test in a shorter time.

Select the diagnostic tests you want to run, or press F7 to select all diagnostic tests on an AMIDiag menu. Set the Quick Test parameter to Yes. If you press F10 to run the tests, all tests except the tests that support Quick Test will run normally. The tests that support Quick Test run in quick mode. If your server has several IDE and SCSI hard disk and CD-ROM drives, testing all drives will take a long time. When you select Quick Test, the IDE and SCSI devices will be tested quickly, saving time.

Use quick test mode for fast system verification

Press F8 when the AMIDiag main menu is displayed to set this parameter to Yes and to select the tests defined as System Quick Test Components. You can either press F4 to script this test, or press F10 to run the tests in batch mode.

Execution count: The Execution Count menu appears when you select Execution Count from the Edit Batch Parameters menu.

IBM 8688 — Options menu diagram (page 76)
Abb. 14 · Options menu

Choose the number of times that you want to run the AMIDiag tests on the associated AMIDiag menus. You can run each test up to 255 times. If you have set the Passbound parameters (see the previous screen) to 5 and you set the repeat count to 5, the test will be run a total of 25 times.

Page 77 of the IBM 8688 user manual — Options menu
Seite 77 · Zum Vergrößern klicken
Seite 77
Interactive TestWhen you select Interactive Test , and press Enter, the following screen is displayed:
IBM 8688 — Options menu diagram (page 77)
Abb. 15 · Options menu

Select the test group. A list of all tests appears. Tests that support interactive test have Yes beside them. Select the tests to run, and press Enter.

Quick TestWhen you select Quick Test , the following Quick Test menu is displayed:
IBM 8688 — Options menu diagram (page 77)
Abb. 16 · Options menu

Select the test group. A list of all tests appears. Tests that support Quick Test have Yes beside them. Select the tests to run, and press Enter.

Chapter 3. Diagnostics 67

Page 78 of the IBM 8688 user manual — Load Batch Parameters
Seite 78 · Zum Vergrößern klicken
Seite 78

Test Parameters: The Test Parameters menu is displayed when you select Edit Batch Parameters from the Options menu.

IBM 8688 — Load Batch Parameters diagram (page 78)
Abb. 17 · Load Batch Parameters

Each item in this menu is the name of an AMIDiag menu. When you select an AMIDiag menu choice, all AMIDiag tests on the menu are listed. Select the tests to run in batch mode, and press Enter.

If you select a test, the parameters for that test are displayed. Set the parameters, and select another diagnostic test. Select CONTINUE, and press Enter when you have set all test parameters for the AMIDiag test to be run in batch mode.

Load Batch Parameters Choose this option to load previously saved AMIDiag batch diagnostic test parameters. The Load Batch Parameters dialogue box appears:

IBM 8688 — Load Batch Parameters diagram (page 78)
Abb. 18 · Load Batch Parameters

Press Enter to accept the default batch parameter file (Diagnostic Utility.INI), or type the appropriate AMIDiag batch parameter filename. You can use any valid filename.

Page 79 of the IBM 8688 user manual — Save Batch Parameters
Seite 79 · Zum Vergrößern klicken
Seite 79

The filename extension does not have to be .INI. You can then press F10 to run the AMIDiag tests that are specified in this file.

Save Batch Parameters Select this choice to save all batch mode parameters, selected tests, selected devices, and error logging information to an AMIDiag batch parameter file. You can then load this ASCII file later and use the same saved options and test parameters every time you perform a AMIDiag session. To save batch parameters, complete the following steps: 1. From the AMIDiag main menu, select Options, and press Enter. 2. Select Save Batch Parameters, and press Enter. The following appears:

IBM 8688 — Save Batch Parameters diagram (page 79)
Abb. 19 · Save Batch Parameters
3. Press Enter to accept the default batch parameter file (Diagnostic Utility.INI), or type the appropriate AMIDiag batch parameter filename.

Generate Report To generate a report of the diagnostic test and all errors found, complete the following steps: 1. From the main menu, select Options, and press Enter.

2. Select Generate Report to specify the output device: disk file or serial port.

file system is available to write the report to from EFI.

Chapter 3. Diagnostics 69

Page 80 of the IBM 8688 user manual — Diagnostic error code tables
Seite 80 · Zum Vergrößern klicken
Seite 80

The report generation parameters are as follows:

IBM 8688 — Toggle All Tests in Menu diagram (page 80)
Abb. 20 · Toggle All Tests in Menu
3. Select CONTINUE after setting report parameters, and press Enter.

You can customize how the errors are logged and where the logs are saved using the choices in this menu. You can define the destination for the output, log which tests are conducted, when the test is started, when the test completes, and whether the test will log only errors.

Toggle All Tests in Menu Select this choice to display the list of test menus and to select a menu. When you select a menu, the tests for that menu display. Select Toggle all tests to select all tests. Select Toggle all quick tests to select all quick tests. Quick tests are abbreviated versions of the complete test.

Run Selected Tests Select this choice to run the tests that you have selected.

Toggle Hidden Test Display Select this choice to display all hidden tests.

Ethernet diagnostic tests

Ethernet diagnostic programs are stored on the Resource CD. To use this CD, complete the following steps: 1. Insert the CD into the DVD/CD-ROM drive, and restart the server. 2. Go to the EFI shell; then, change to the file system on the CD, and navigate to the x450 subdirectory on the CD. 3. Type enet_diag.nsh, and press Enter to run the program from the CD.

See the documentation on the Resource CD for more information about Ethernet diagnostic tests and error codes.

Diagnostic error code tables

For descriptions of the error codes that might appear when you run the AMIDiag program, see “Diagnostic error codes” on page 159.

Page 81 of the IBM 8688 user manual — Recovering SAL/EFI code
Seite 81 · Zum Vergrößern klicken
Seite 81

Small computer system interface (SCSI) messages

If you receive a SCSI error message, see “SCSI error messages” on page 184.

indicates that the SAL/EFI is not installed.

Recovering SAL/EFI code

If the SAL/EFI code has become damaged, such as from a power failure during a flash update, you can recover the SAL/EFI code using the SAL/EFI code page jumper (J28 on the I/O board) and the recovery program on the Resource CD that comes with the xSeries 450 server.

You can download the latest version of the SAL/EFI flash utility program from the World Wide Web. Go to http;//www.ibm.com/eserver/xseries/ click IBM Server Support, and make the selections for the server.

To perform a full recovery of the SAL/EFI code, complete the following steps:

1. Review the safety information beginning on page 197. Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78.

this procedure. 2. Insert the Resource CD into the DVD/CD-RW drive.

3. Turn off the server and peripheral devices, and disconnect all external cables and power cords; then, open the cover (see “Opening the cover” on page 88). 4. Remove fans 3 and 4. For instructions, see “Replacing fan 3 or 4” on page 108. 5. Locate the SAL/EFI code page jumper (J28) on the I/O board.
IBM 8688 — Recovering SAL/EFI code diagram (page 81)
Abb. 21 · Recovering SAL/EFI code

Chapter 3. Diagnostics 71

Jumper (J28)

Page 82 of the IBM 8688 user manual — Clearing a power-on password
Seite 82 · Zum Vergrößern klicken
Seite 82
6. If there is a jumper on J28, move the jumper from pins 1 and 2 to pins 2 and 3 to enable the SAL/EFI backup code page. If there is no jumper, add one to J28 pins 2 and 3.

7. Replace fans 3 and 4, and reconnect all external cables and power cords; then, turn on the peripheral devices. 8. Start up the server. After 5-10 seconds, the blue Attention LED on the Light Path card blinks. 9. If the green access LED on the DVD/CD-RW drive does not blink to indicate that the recovery flash image is being read within 2 minutes, press the reset button on the front of the server to retry the update. If the LED fails to blink again, the SAL/EFI backup code page might be damaged, and you might need to replace the I/O board to correct the problem. Run the AMIDiag program to test the I/O board; then, see “I/O board, riser card, and Remote Supervisor Adapter” on page 130 for instructions. 10. When the DVD/CD-RW LED stops blinking, wait at least 5 minutes for the flash update to complete. 11. Remove the Resource CD from the drive, and repeat steps 3 on page 71 through 5 on page 71. Then, continue with step 12. 12. Move the jumper on J28 to pins 1 and 2 to return to normal startup mode. 13. Replace the fans, and close the cover (see “Closing the cover” on page 111).

14. Reconnect all external cables and power cords, and turn on the peripheral devices. 15. Turn on the server.

instructions, see “Updating the firmware” on page 39.

Clearing a power-on password

This section applies to lost or forgotten passwords. For more information about lost or forgotten passwords, see “Using the Configuration/Setup Utility program” on page 12.

Complete the following steps to clear the power-on password:

1. Review the safety information beginning on page 197.

Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78. 2. Turn off the server and all attached devices. 3. Unplug the power cord, and disconnect all external cables. 4. Open the top cover (see “Opening the cover” on page 88). 5. Remove fans 3 and 4. For instructions, see “Replacing fan 3 or 4” on page 108.

Page 83 of the IBM 8688 user manual — Clearing CMOS
Seite 83 · Zum Vergrößern klicken
Seite 83
6. Locate the clear password jumper (J20) on the I/O board. The following illustration shows the location of the jumper on the I/O board.
IBM 8688 — Clearing CMOS diagram (page 83)
Abb. 22 · Clearing CMOS

Clear password jumper (J20)

7. Move the clear password jumper from pins 1 and 2 to pins 2 and 3. 8. Replace fans 3 and 4, and reconnect all external cables and power cords; then, turn on the peripheral devices.
9. Turn on the server. The EFI Boot Manager program starts. 10. Follow the instructions to create a new password.
11. Repeat steps 1 on page 72 through 5 on page 72. 12. Return the clear password jumper to pins 1 and 2.

replaced to pins 1 and 2. 13. Repeat steps 8 through 10. 14. Close the cover (see “Closing the cover” on page 111). 15. Connect the server to a power source, keyboard, monitor, and mouse. 16. Turn on the server.

Clearing CMOS

Complete the following steps to set the CMOS recovery jumper:

1. Review the safety information beginning on page 197. Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78. 2. Turn off the server and all attached devices. 3. Unplug the power cord, and disconnect all external cables. 4. Open the top cover (see “Opening the cover” on page 88). 5. Remove fans 3 and 4. For instructions, see “Replacing fan 3 or 4” on page 108.

Chapter 3. Diagnostics 73

Page 84 of the IBM 8688 user manual — Power checkout
Seite 84 · Zum Vergrößern klicken
Seite 84
6. Locate the CMOS recovery jumper (J19) on the I/O board. The following illustration shows the location of the jumper on the I/O board.
IBM 8688 — Power checkout diagram (page 84)
Abb. 23 · Power checkout

CMOS recovery jumper (J19)

7. Move the CMOS recovery jumper from pins 1 and 2 to pins 2 and 3. 8. Wait 60 seconds; then, return the CMOS recovery jumper to pins 1 and 2. 9. Replace fans 3 and 4. 10. Close the cover (see “Closing the cover” on page 111). 11. Connect the server to a power source, keyboard, monitor, and mouse. 12. Turn on the server. The EFI Boot Manager program starts. 13. Follow the instructions to erase the existing password or create a new password. 14. Select Save Settings, and press Enter.

Power checkout

Power problems can be difficult to solve. For example, a short circuit can exist anywhere on any of the power distribution buses. Usually a short circuit will cause the power subsystem to shut down because of an overcurrent condition.

Follow this general procedure for troubleshooting power problems: 1. Turn off the server, and disconnect all ac power cords. 2. Check for loose cables in the power subsystem. Also check for short circuits; for example, a loose screw might be causing a short circuit on a circuit board. 3. Remove adapters and disconnect the cables and power connectors to all internal and external devices until the server is at the minimum configuration required to start the server (see the note about minimum operating requirements on page 180). 4. Reconnect all ac power cords, and turn on the server. If the server starts successfully, replace adapters and devices one at a time until the problem is isolated. If the server does not start up from the minimal configuration, replace FRUs of the minimal configuration one at a time until the problem is isolated.

To use this method, it is important to know the minimum configuration required for a system to start (see the minimum configuration requirements at “Undetermined problems” on page 185).

Page 85 of the IBM 8688 user manual — Network connection problems
Seite 85 · Zum Vergrößern klicken
Seite 85

Troubleshooting the Ethernet controller

If a problem occurs with the 10/100/1000 Mbps Ethernet controller, use the Ethernet diagnostic program on the Resource CD to diagnose the problem. For more information about this CD, see “Ethernet diagnostic tests” on page 70. For information about the Ethernet error codes and actions to take, see the documentation on the Resource CD.

Network connection problems

If the Ethernet controller cannot connect to the network, check the following conditions: v Make sure that the cable is installed correctly.

The network cable must be securely attached at all connections. If the cable is attached but the problem remains, try a different cable.

If you set the Ethernet controller to operate at either 100 Mbps or 1000 Mbps, you must use Category 5 or higher cabling. v Determine whether the hub supports auto-negotiation. If it does not, try configuring the integrated Ethernet controller manually to match the speed and duplex mode of the hub. v Check the Ethernet controller LEDs on the rear of the server. These LEDs indicate whether a problem exists with the connector, cable, or hub. – The Ethernet transmit/receive activity LED on the rear of the server is lit when the Ethernet controller sends or receives data over the Ethernet network. If the Ethernet transmit/receive activity LED is off, make sure that the hub and network are operating and that the correct device drivers are installed. – The Ethernet link status LED on the rear of the server is lit when the Ethernet controller receives a LINK pulse from the hub. If the LED is off, there might be a defective connector or cable or a problem with the hub. v Make sure that you are using the correct device drivers, which are supplied with your server. v Check for operating-system-specific causes for the problem. v Make sure that the device drivers on the client and server are using the same protocol. v Test the Ethernet controller. The way the Ethernet controller is tested depends on which operating system you are using (see the Ethernet controller device driver README files).

Chapter 3. Diagnostics 75

Page 86 of the IBM 8688 user manual — Ethernet controller messages
Seite 86 · Zum Vergrößern klicken
Seite 86

Ethernet controller troubleshooting chart

Use the following troubleshooting chart to find solutions to 10/100/1000 Mbps Ethernet controller problems that have definite symptoms.

Ethernet controller problems FRU/actions

The server stops running when loading device drivers.

Check the following: v Make sure that you are using the most recent device driver available from the World Wide Web. v Reseat or replace the adapter.

Ethernet link status LED does not work.

Check the following: v Make sure that the hub is turned on. v Check all connections at the Ethernet controller and at the hub. v Use another port on the hub. v If the hub does not support auto-negotiation, manually configure the Ethernet controller to match the hub. v If you manually configured the Duplex mode, make sure that you also manually configure the speed. v Reseat or replace the adapter.

The Ethernet transmit/receive activity LED does not work.

Check the following: v Make sure that you have loaded the network device drivers. v The network might be idle. Try sending data from this server.

Data is incorrect or sporadic. Check the following: v Make sure that you are using Category 5 or higher cabling when operating the server at 100 Mbps or at 1000 Mbps. v Make sure that the cables do not run close to noise-inducing sources like fluorescent lights.

Ethernet controller messages

The integrated Ethernet controller might display messages from certain device drivers. The latest information available concerning these messages will be made available at the IBM Support Web site at http://www.ibm.com/eserver/xseries

Page 87 of the IBM 8688 user manual — Working inside a server with power on
Seite 87 · Zum Vergrößern klicken
Seite 87

Chapter 4. Installing options

This chapter provides detailed instructions for installing hardware options in your server.

Installation guidelines

Before you begin to install options in your server, read the following information: v Read the safety information beginning on page 197 and the guidelines in “Handling static-sensitive devices” on page 78. This information will help you work safely with your server or options. v Make sure that you have an adequate number of properly grounded electrical outlets for your server, monitor, and any other devices that you will connect to the server. v Back up all important data before you make changes to disk drives. v For a list of supported options for your server, go to http://www.ibm.com/pc/us/compat/

software documentation provided with those servers for more information.

System reliability considerations

To help ensure proper cooling and system reliability, make sure that: v Each of the drive bays has either a drive or a filler panel installed. v There is space around the server to allow the cooling system to work properly. v Cables for optional adapters are routed according to the instructions that are provided with the adapters. v All microprocessors have the same cache size and type and the same clock speed. v For proper cooling, do not leave the cover open for more than 15 minutes. v A failed fan is replaced within 48 hours. v The top cover is closed during normal operation.

v Do not remove a defective power supply until a replacement is available. v For redundant and hot-swappable operation, the power supplies are connected to 200-240 V ac.

Working inside a server with power on

Your server supports hot-swap devices and is designed to operate safely while turned on with the cover removed. Follow these guidelines when you work inside a server that is turned on: v Avoid loose-fitting clothing on your forearms. Button long-sleeved shirts before working inside the server; do not wear cuff links while you are working inside the server. v Do not allow your necktie or scarf to hang inside the server. v Remove jewelry, such as bracelets, rings, necklaces, and loose-fitting wrist watches. v Remove items from your shirt pocket (such as pens or pencils) that could fall into the server as you lean over it.

© Copyright IBM Corp. 2003 77

Page 88 of the IBM 8688 user manual — Major components of the xSeries 450 server
Seite 88 · Zum Vergrößern klicken
Seite 88

v Take care to avoid dropping any metallic objects, such as paper clips, hair pins, or screws, into the server.

Handling static-sensitive devices

To reduce the possibility of electrostatic discharge, observe the following precautions: v Limit your movement. Movement can cause static electricity to build up around you.

v Handle the device carefully, holding it by its edges or its frame. v Do not touch solder joints, pins, or exposed printed circuitry. v Do not leave the device where others can handle and damage it. v While the device is still in its anti-static package, touch it to an unpainted metal part of the system unit for at least 2 seconds. This drains static electricity from the package and from your body. v Remove the device from its package, and install it directly into the system unit without setting down the device. If it is necessary to set down the device, place it in to its static-protective package. Do not place the device on your system unit cover or on a metal surface. v Take additional care when handling devices during cold weather. Heating reduces indoor humidity and increases static electricity. v Wear a properly grounded wrist strap against your skin to help eliminate static electricity from your body.

Major components of the xSeries 450 server

The orange color on components and labels in the server indicates hot-swap or hot-plug components. You can install or remove these components while the server is running, provided that the server is configured to support hot-swap and hot-plug components.

The blue color on components and labels indicates touch points, where a component can be gripped, a latch moved, and so on.

Page 89 of the IBM 8688 user manual — Handling static-sensitive devices
Seite 89 · Zum Vergrößern klicken
Seite 89

The following illustration shows the locations of major components in your server.

IBM 8688 — Handling static-sensitive devices diagram (page 89)
Abb. 24 · Handling static-sensitive devices

Chapter 4. Installing options 79

DIMM access doors · DVD-ROM drive

Page 90 of the IBM 8688 user manual — Memory board internal connectors and LEDs
Seite 90 · Zum Vergrößern klicken
Seite 90

Connector and LED locations

The illustrations in this section show the locations of connectors, switch and jumper blocks, and LEDs.

Memory board internal connectors and LEDs

The following illustrations show the internal connectors and LEDs on the memory board.

IBM 8688 — Memory board internal connectors and LEDs diagram (page 90)
Abb. 25 · Memory board internal connectors and LEDs

DIMM error LED (14 places)

IBM 8688 — Memory board internal connectors and LEDs diagram (page 90)
Abb. 26 · Memory board internal connectors and LEDs

1.8 V VRM error LED 2.5 V VRM port 1 error LED

DIMM slots · VRM connectors

Page 91 of the IBM 8688 user manual — Memory switch card LEDs
Seite 91 · Zum Vergrößern klicken
Seite 91
IBM 8688 — Memory switch card LEDs diagram (page 91)
Abb. 27 · Memory switch card LEDs

The following illustration identifies the LEDs on the memory-board assembly.

Memory switch card LEDs

The following illustration shows the LEDs on the memory switch card.

IBM 8688 — Memory switch card LEDs diagram (page 91)
Abb. 28 · Memory switch card LEDs

Chapter 4. Installing options 81

Page 92 of the IBM 8688 user manual — Processor board internal connectors and LEDs
Seite 92 · Zum Vergrößern klicken
Seite 92

Processor board internal connectors and LEDs

The following illustrations show the internal connectors on the processor board.

IBM 8688 — Processor board internal connectors and LEDs diagram (page 92)
Abb. 29 · Processor board internal connectors and LEDs

Microprocessor 3 power module socket

Microprocessor 3 power module cable connector

Microprocessor 1 power module socket

Microprocessor 1 power module cable connector

Light Path Diagnostic button

IBM 8688 — Processor board internal connectors and LEDs diagram (page 92)
Abb. 30 · Processor board internal connectors and LEDs

Microprocessor 4 power module socket

Microprocessor 4 power module cable connector

Microprocessor 2 power module socket

Microprocessor 2 power module cable connector

Show 4 more labels / short text on this page
Front side · Reverse Side · Microprocessor 4 socket · Microprocessor 2 socket
Page 93 of the IBM 8688 user manual — Processor board internal connectors and LEDs
Seite 93 · Zum Vergrößern klicken
Seite 93

The following illustrations show the LEDs on the processor board.

Microprocessor 3 error LED

IBM 8688 — Processor board internal connectors and LEDs diagram (page 93)
Abb. 31 · Processor board internal connectors and LEDs

Microprocessor 3 power module error LED

Microprocessor 1 power module error LED

Microprocessor 1 error LED

IBM 8688 — Processor board internal connectors and LEDs diagram (page 93)
Abb. 32 · Processor board internal connectors and LEDs

Microprocessor 4 power module error LED

Microprocessor 2 power module error LED

Microprocessor 2 error LED

Chapter 4. Installing options 83

Front side · Power-good LED · Reverse side

Page 94 of the IBM 8688 user manual — Midplane board connectors and LEDs
Seite 94 · Zum Vergrößern klicken
Seite 94

Midplane board connectors and LEDs

The following illustration shows the connectors on the midplane board.

IBM 8688 — Midplane board connectors and LEDs diagram (page 94)
Abb. 33 · Midplane board connectors and LEDs

3.3V VRM connector

Light Path card connector

Power backplane 12V connector

The following illustration shows the LEDs on the midplane board.

IBM 8688 — Midplane board connectors and LEDs diagram (page 94)
Abb. 34 · Midplane board connectors and LEDs

DMC heartbeat LED Machine check abort initiated (NMI) LED

Microprocessor power connector · VRM error LED · Diagnostic display

Page 95 of the IBM 8688 user manual — Midplane board connectors and LEDs
Seite 95 · Zum Vergrößern klicken
Seite 95

You can see the midplane board LEDs on the top of the server. These LEDs are numbered from 1-6 and indicate the board on which an error has been detected.

6 I/O board error LED 5 Remote Supervisor Adapter error LED

IBM 8688 — Midplane board connectors and LEDs diagram (page 95)
Abb. 35 · Midplane board connectors and LEDs

Table 7. Midplane board LEDs

IBM 8688 — Midplane board connectors and LEDs diagram (page 95)
Abb. 36 · Midplane board connectors and LEDs

6 I/O-board error LED

Chapter 4. Installing options 85

LED number Board

Page 96 of the IBM 8688 user manual — PCI-X board internal connectors and LEDs
Seite 96 · Zum Vergrößern klicken
Seite 96

PCI-X board internal connectors and LEDs

The following illustration shows the internal connectors and LEDs on the PCI-X board.

PCI-X slot 3 (100 ) MHz PCI-X slot 4 (100 ) MHz PCI-X slot 5 (133 ) MHz

PCI-X slot 2 (66 ) MHz

PCI-X slot 6 (133 MHz) Attention LED

PCI-X slot 1 (66 ) MHz

Power LED

Page 97 of the IBM 8688 user manual — I/O-board jumpers
Seite 97 · Zum Vergrößern klicken
Seite 97

I/O-board internal connectors

The following illustration shows the internal connectors on the I/O board.

I/O VRM

Fans 1 and 2 connectors

I/O-board jumpers

The following illustration identifies the jumpers on the I/O board.

Clear power-on password jumper (J20)

CMOS recovery jumper (J19)

SAL/EFI code page jumper (J28)

Chapter 4. Installing options 87

Show 8 more labels / short text on this page
Riser card connector · SCSI B connector · Fan 4 connector · Fan 3 connector · Power/reset connector · USB cable connector · SCSI A connector · Media bays connector
Page 98 of the IBM 8688 user manual — (RJ-14)
Seite 98 · Zum Vergrößern klicken
Seite 98

Remote Supervisor Adapter connectors and LEDs

The following illustration identifies the connectors and LEDs on the Remote Supervisor Adapter.

IBM 8688 — Remote Supervisor Adapter connectors and LEDs diagram (page 98)
Abb. 37 · Remote Supervisor Adapter connectors and LEDs

(RJ-14)

Opening the cover

Complete the following steps to open the server cover: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Slide the server out from the rack. 3. Pull the release latch on the left side of the top cover to the right. 4. Using the finger hole in the release latch, open the left side of the cover; then, open the right side of the cover.

IBM 8688 — (RJ-14) diagram (page 98)
Abb. 38

Lithium battery · Ethernet activity

Page 99 of the IBM 8688 user manual — Removing and replacing the bezel
Seite 99 · Zum Vergrößern klicken
Seite 99

Removing and replacing the bezel

Complete the following steps to remove the bezel:

1. Press on the two tabs at the top edge of the bezel, and pull the top of the bezel slightly away from the server. 2. Press on the two tabs at the bottom edge of the bezel, and pull the bezel off the server. Store the bezel in a safe place.
IBM 8688 — Removing and replacing the bezel diagram (page 99)
Abb. 39 · Removing and replacing the bezel

Complete the following steps to replace the bezel: 1. Align the four tabs on the bezel with the slots in the server chassis. 2. Press firmly against the front of the bezel until it snaps into place.

IBM 8688 — Removing and replacing the bezel diagram (page 99)
Abb. 40 · Removing and replacing the bezel

Chapter 4. Installing options 89

Page 100 of the IBM 8688 user manual — Removing and replacing a hot-swap power supply
Seite 100 · Zum Vergrößern klicken
Seite 100

Removing and replacing a hot-swap power supply

Your server comes with two hot-swap power supplies, which you can remove and replace without turning off the server. The following illustration shows the locations of the power supplies on the front of the server.

IBM 8688 — Removing and replacing a hot-swap power supply diagram (page 100)
Abb. 41 · Removing and replacing a hot-swap power supply

Before you remove or replace a power supply, review the following information.

If you install or remove a power supply, observe the following precautions.

Statement 8:

Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.

Complete the following steps to remove and replace a power supply: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Remove the front bezel (see “Removing and replacing the bezel” on page 89 for instructions about removing the front bezel).

Show 5 more labels / short text on this page
Power-on LED · Power button · Reset button · Power-supply latch · Handle
Page 101 of the IBM 8688 user manual — AC LED
Seite 101 · Zum Vergrößern klicken
Seite 101
3. To remove the power supply from the server, press the latch; then, lift the handle on the power supply to the open position and pull the power supply out from the server.
4. Install the new power supply: a. Place the handle on the power supply in the open position. b. Slide the power supply into the chassis and press the handle to the closed position.

AC LED

DC LED

Power-supply handle (in open position)

5. Verify that the dc power LED and the ac power LED on the power supply are lit, indicating that the power supply is operating properly. 6. Replace the front bezel on the server (see “Removing and replacing the bezel” on page 89 for instructions).

Chapter 4. Installing options 91

Power supply · Power-supply latch

Page 102 of the IBM 8688 user manual — C (7) 5 133
Seite 102 · Zum Vergrößern klicken
Seite 102

Installing an adapter

The following notes describe the types of adapters that your server supports and other information that you must consider when installing an adapter: v The following illustration shows the location and bus speeds of the PCI-X expansion slots on the PCI-X board.

PCI-X slot 3 (100 ) MHz PCI-X slot 4 (100 ) MHz PCI-X slot 5 (133 ) MHz

PCI-X slot 2 (66 ) MHz

PCI-X slot 6 (133 MHz) Attention LED

PCI-X slot 1 (66 ) MHz

v Locate the documentation that comes with the adapter, and follow those instructions in addition to the instructions in this section. If you need to change the switch settings or jumper settings on your adapter, follow the instructions that come with the adapter. v Video adapters are not supported.

v Some full-length adapters have extension handles or brackets installed. Before installing the adapter, you must remove the extension handle or bracket. v Your server supports six hot-plug 64-bit adapters in the expansion slots on the PCI-X board, as shown in the following table.

Bus Slot Supported adapter speed (MHz)

A (2)

3 100 (133 if slot 4 is empty)

B (9)

4 100 (133 if slot 3 is empty)

C (7) 5 133

D (5) 6 133

Power LED

Page 103 of the IBM 8688 user manual — Installing an adapter
Seite 103 · Zum Vergrößern klicken
Seite 103

v You can install both PCI and PCI-X adapters on the same bus. However, if you install a PCI adapter and a PCI-X adapter on the same bus, the PCI-X features of the PCI-X adapter will be disabled, and the adapter will function as a PCI adapter. v You can install PCI or PCI-X adapters of speeds faster than what is labeled for a particular PCI-X bus. For example, if you install two 133 MHz adapters into slots that are labeled as 100 MHz slots, the adapters will operate at 100 MHz. v If you install a 33 MHz and a 66 MHz adapter on the same bus, the bus speed will match that of the slowest adapter.

v If a single 133 MHz adapter is installed on PCI-X bus B (slots 3 and 4) and the other slot on PCI-X bus B is empty, the adapter will operate at 133 MHz. v The server scans PCI-X slots in the following order: the xSeries 450 integrated devices are scanned first; then, PCI-X slots 1, 2, 6, 5, 3, and 4. If an RXE-100 enclosure is attached to an xSeries 450 server, the scan order is as follows: the xSeries 450 integrated devices are scanned first; then, PCI-X slots 1, 2, 6, 5, 3, and 4; then, the RXE-100 PCI slots 11, 12, 9, 10, 7, 8, 17, 18, 15, 16, 13, and 14. v Your server supports 3.3 V and universal adapters; it does not support 5.0 V adapters.

Complete the following steps to install an adapter: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78. 2. Disable the PCI-X slot through your operating system before you insert or remove a PCI or PCI-X adapter.

PCI-X slot. If your operating system does not support this function, turn off the server and peripheral devices, and disconnect the power cords and all external devices from the back of the server before proceeding. 3. Open the top cover. 4. Follow the cabling instructions, if any, that come with the adapter. Route the adapter cables before you install the adapter. 5. Follow the instructions that come with the adapter to set jumpers or switches, if any.

Chapter 4. Installing options 93

Page 104 of the IBM 8688 user manual — Installing an adapter
Seite 104 · Zum Vergrößern klicken
Seite 104
6. Install the adapter: a. If you are installing a full-length adapter, open the blue adapter guide by lifting the front edge, as shown in the illustration. b. Push the orange adapter-retention latch toward the rear of the server, and open the tab. c. Remove the expansion-slot cover. d. Carefully grasp the adapter by its top edge or upper corners, and align it with the connector on the PCI-X board.

installing a long adapter, you must remove the extension handle or bracket. e. Press the adapter firmly into the adapter connector. Attention: When you install an adapter, be sure the adapter is correctly seated in the connector. Improperly seated adapters might cause damage to the PCI-X board or to the adapter. f. Push down on the blue adapter guide to keep the adapter steady. g. Close the tab; then, push down on the blue adapter-retention latch until it clicks into place, securing the adapter.

IBM 8688 — Installing an adapter diagram (page 104)
Abb. 42 · Installing an adapter
7. Connect the internal cables to the adapter. 8. If you disabled the slot in step 2 on page 93, enable the slot. 9. If you have other options to install or remove, do so now. Otherwise, go to “Completing the installation” on page 111.

Adapter retention latch · Tab

Page 105 of the IBM 8688 user manual — Installing a hot-swap hard disk drive
Seite 105 · Zum Vergrößern klicken
Seite 105

Installing a hot-swap hard disk drive

Complete the following steps to install or replace a hot-swap hard disk drive.

Attention: v When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78. v Before you hot-swap a drive, make sure that the drive you are replacing is defective. If you partially or completely remove a good drive instead of a defective one, your server might lose valuable data. 1. Inspect the drive for any signs of damage. 2. Read the safety information beginning on page 197 and “Installation guidelines” on page 77.

3. Check the instructions that come with the drive for more information about installing your drive. 4. Remove the filler panel or defective hard disk drive from the hard disk drive bay. 5. Install the new hard disk drive in the drive bay: a. Ensure that the handle on the hard disk drive tray is in the open position. b. Slide the drive into the bay until it stops. c. Push the handle on the front of the hard disk drive closed.

d. Check the hard disk drive status LED to verify that the hard disk drive is operating properly. If the amber hard disk drive error LED for a drive is lit continuously, that individual drive is damaged and needs to be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed. 6. If you have other options to install or remove, do so now.

Chapter 4. Installing options 95

Filler panel

Page 106 of the IBM 8688 user manual — Installing a 1.44 MB diskette drive
Seite 106 · Zum Vergrößern klicken
Seite 106

Installing a 1.44 MB diskette drive

The following notes describe the type of diskette drive that your server supports and other information that you must consider when installing a diskette drive: v Your xSeries 450 server supports one diskette drive. v The diskette drive must be installed in the left drive bay. v The IDE drives installed in your server are not hot-swappable. v Your operating system must support a diskette drive.

Complete the following steps to install a diskette drive in your server: 1. Review the information in “Safety information” on page 197, and “Installation guidelines” on page 77. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external devices from the back of the server.

3. Inspect the drive for any signs of damage. 4. Slide the drive into the left drive bay until it stops.
IBM 8688 — Installing a 1.44 MB diskette drive diagram (page 106)
Abb. 43 · Installing a 1.44 MB diskette drive
5. If you have other options to install or remove, do so now. Otherwise, connect the power cords and turn on the server.

Complete the following steps to remove a diskette drive from your server: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external devices from the back of the server.

3. Push the drive-eject button to the right. 4. Using the tab, pull the diskette drive partially out of the server; then, grasp the drive and remove it from the server. 5. If you have other options to install or remove, do so now. Otherwise, connect the external devices and power cords, and turn on the server.

Removable media bays · Filler panel

Page 107 of the IBM 8688 user manual — Installing a CD-ROM or DVD-ROM drive
Seite 107 · Zum Vergrößern klicken
Seite 107

Installing a CD-ROM or DVD-ROM drive

The following notes describe the types of CD-ROM or DVD-ROM drives that your server supports and other information that you must consider when installing a CD-ROM or DVD-ROM drive: v Your xSeries 450 server supports up to two CD-ROM drives, or two DVD-ROM drives, or a combination. v If you have only one IDE device installed, it must be installed in the right removable-media bay. CD-ROM or DVD-ROM drives can be installed in either removable-media bay.

Complete the following steps to install a CD-ROM or DVD-ROM drive in your server: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external devices from the back of the server. 3. Push the drive-eject button to the right. 4. Inspect the drive for any signs of damage.

5. Slide the CD-ROM or DVD-ROM drive into the drive bay until it stops.
IBM 8688 — Installing a CD-ROM or DVD-ROM drive diagram (page 107)
Abb. 44 · Installing a CD-ROM or DVD-ROM drive
6. If you have other options to install or remove, do so now. Otherwise, connect the power cords and turn on the server.

Complete the following steps to remove a CD-ROM or DVD-ROM drive from the server: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external devices from the back of the server.

3. Push the drive-eject button to the right.

Chapter 4. Installing options 97

Removable media bays

Page 108 of the IBM 8688 user manual — Installing memory
Seite 108 · Zum Vergrößern klicken
Seite 108
4. Using the tab, pull the CD-ROM or DVD-ROM drive partially out of the server; then, grasp the drive and remove it from the server. 5. If you have other options to install or remove, do so now. Otherwise, connect the external devices and power cords and turn on the server.

Installing memory

The following notes describe the types of dual inline memory modules (DIMMs) that your server supports and other information that you must consider when installing DIMMs: v Your server supports 512 MB, 1 GB, and 2 GB DIMMs, for a maximum of 40 GB of system memory. Your server supports up to twenty-eight 2.5 V, 184 pin, PC2100, ECC DDR SDRAM, 133 MHZ DIMMs. Go to the ServerProven® list at http://www.ibm.com/pc/compat/ for a list of memory modules you can use with your server.

v Your server supports a maximum of only 20 DIMMs (10 per port) if any connector contains a 2 GB DIMM. Your server supports a maximum of 28 DIMMs (14 per port) if only 512 MB and 1 GB DIMMs are installed. v Your server comes with a minimum of two 512 MB DIMMs, installed in slots 1 and 14. When installing additional DIMMs, you must install two DIMMS at a time, in the order shown in the following table to maintain performance.

Table 8. DIMM installation sequence

Pair DIMM connectors (Port 1) Pair DIMM connectors (Port 2)

1 1 and 14 2 15 and 28

3 4 and 11 4 18 and 25

5 2 and 13 6 16 and 27

7 5 and 10 8 19 and 24

9 3 and 12 10 17 and 26

11 6 and 9 12 20 and 23

13 7 and 8 14 21 and 22

Port 1 Port 2

DIMM error LEDs are built into each handle

v Each DIMM in a pair must be of the same size and technology to ensure that the server will operate properly.

Page 109 of the IBM 8688 user manual — Installing memory
Seite 109 · Zum Vergrößern klicken
Seite 109

v When using memory mirroring, you must install two pairs of DIMMs at a time. The four DIMMs in each bank must be identical. The following table shows the pairs that are in each bank. See Table 8 on page 98 for the DIMM connector pair assignments.

Table 9. Memory mirroring DIMM installation sequence

Set DIMM pairs Set DIMM pairs

1 1 and 2 5 9 and 10

2 3 and 4 6 11 and 12

3 5 and 6 7 13 and 14

4 7 and 8

v When you install or remove DIMMs, the server configuration information changes. When you restart the server, the system displays a message indicating that the memory configuration has changed.

Complete the following steps to install a DIMM in your server: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables; then, open the server cover. Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78. 3. Open the DIMM access door that covers the DIMM connector into which you will be installing the DIMM.

Chapter 4. Installing options 99

Page 110 of the IBM 8688 user manual — Installing and replacing a microprocessor and power module
Seite 110 · Zum Vergrößern klicken
Seite 110

4. Install the new DIMM: a. Open the retaining clip on each end of the DIMM connector. b. Touch the static-protective package containing the DIMM to any unpainted metal surface on the server. Then, remove the DIMM from the package. Attention: To avoid breaking the retaining clips or damaging the DIMM connectors, open and close the clips gently. c. Turn the DIMM so that the DIMM keys align correctly with the slot. d. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously. The retaining clips snap into the locked position when the DIMM is firmly seated in the connector. If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly inserted; open the retaining clips, remove the DIMM, and then reinsert it.

IBM 8688 — Installing and replacing a microprocessor and power module diagram (page 110)
Abb. 45 · Installing and replacing a microprocessor and power…
5. Close the DIMM access door. 6. If you have other options to install or remove, do so now.
7. Close the server cover. See “Completing the installation” on page 111.

Installing and replacing a microprocessor and power module

Consider the following when installing and replacing a microprocessor into the xSeries 450 server: v Your server supports up to four Intel Itanium 2 microprocessors. v Read the documentation that comes with the microprocessor to determine whether you need to update the server SAL/EFI code. To download the most current level of SAL/EFI code for the server, go to http://www.ibm.com/pc/support/ on the World Wide Web. v (Optional) Obtain an SMP-capable operating system. For a list of supported operating systems, go to http://www.ibm.com/pc/us/compat/ on the World Wide Web. v You will need the following tools: – Flat-blade screwdriver – 2.5-mm hex (Allen) wrench (provided with the microprocessor option)

DIMM slot 28 · DIMM slot 14

Page 111 of the IBM 8688 user manual — Installing and replacing a microprocessor and power module
Seite 111 · Zum Vergrößern klicken
Seite 111

– T15 Torx wrench (provided with the microprocessor option) v To order additional microprocessor options, contact your IBM marketing representative or authorized reseller. v Populate the microprocessor sockets in numeric order. Install the first microprocessor in microprocessor socket 1, the second microprocessor in microprocessor socket 2, and so on. v The following illustrations show the locations of the microprocessor connectors on the processor board. Front side

IBM 8688 — Installing and replacing a microprocessor and power module diagram (page 111)
Abb. 46 · Installing and replacing a microprocessor and power…

Microprocessor 3 power module socket

Microprocessor 3 power module cable connector

Microprocessor 1 power module

Microprocessor 1 power module cable connector

IBM 8688 — Installing and replacing a microprocessor and power module diagram (page 111)
Abb. 47 · Installing and replacing a microprocessor and power…

Microprocessor 4 power module socket

Microprocessor 4 power module cable connector

Microprocessor 2 power module socket

Microprocessor 2 power module cable connector

Chapter 4. Installing options 101

Show 5 more labels / short text on this page
Microprocessor 3 baffle · Microprocessor 1 · Reverse side · Microprocessor 4 socket · Microprocessor 2 socket
Page 112 of the IBM 8688 user manual — Installing and replacing a microprocessor and power module
Seite 112 · Zum Vergrößern klicken
Seite 112

Complete the following steps in the prescribed order to install and replace a microprocessor.

1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables; then, open the cover.
3. Remove the memory-board assembly from the server: Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78. a. Pull up on the levers to detach the memory-board assembly. b. Carefully remove the memory-board assembly from the server, and set it aside.
IBM 8688 — Installing and replacing a microprocessor and power module diagram (page 112)
Abb. 48 · Installing and replacing a microprocessor and power…
Page 113 of the IBM 8688 user manual — Installing and replacing a microprocessor and power module
Seite 113 · Zum Vergrößern klicken
Seite 113
4. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server.
IBM 8688 — Installing and replacing a microprocessor and power module diagram (page 113)
Abb. 49 · Installing and replacing a microprocessor and power…
5. Remove the processor-board assembly from the server: Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see “Handling static-sensitive devices” on page 78. a. Press to unlock the levers securing the processor-board assembly and pull up on the levers to release the processor-board assembly. b. Carefully remove the processor-board assembly from the server, and place it on a flat, level, non-conductive surface.
IBM 8688 — Installing and replacing a microprocessor and power module diagram (page 113)
Abb. 50 · Installing and replacing a microprocessor and power…

Chapter 4. Installing options 103

Levers

Page 114 of the IBM 8688 user manual — Installing and replacing a microprocessor and power module
Seite 114 · Zum Vergrößern klicken
Seite 114

provided with the microprocessor option to close and open the socket lock to observe the locking flag in the closed position. Also note the resistance of the locking mechanism in the locked position. When installing the microprocessor, do not force the socket lock clockwise beyond the locked position.

6. If you are installing a new microprocessor, go to step 7 on page 105; otherwise, continue: Attention: Failure to complete the instructions in the prescribed order might cause damage to the microprocessor pins and cause the microprocessor to fail. a. Using the T-handled Torx wrench provided with the microprocessor option, completely loosen the power-module screws. b. Slide the power module from the microprocessor, and remove the power module.

c. Completely loosen the heat-sink screws. d. Use the hex wrench provided with the microprocessor option to open the socket lock, and remove the microprocessor.

Microprocessor · Power module

Page 115 of the IBM 8688 user manual — Installing and replacing a microprocessor and power module
Seite 115 · Zum Vergrößern klicken
Seite 115
7. Install the microprocessor and power module: a. Remove the microprocessor baffle from the microprocessor socket. Keep the microprocessor baffle for future use. b. Remove the protective tape covering the microprocessor socket, if present.

the locking flag in the locked position.

IBM 8688 — Installing and replacing a microprocessor and power module diagram (page 115)
Abb. 51 · Installing and replacing a microprocessor and power…

Chapter 4. Installing options 105

Page 116 of the IBM 8688 user manual — Installing and replacing a microprocessor and power module
Seite 116 · Zum Vergrößern klicken
Seite 116

Attention: 1) Forcing the microprocessor socket lock clockwise beyond the locked position might damage the socket locking mechanism. Before you install a microprocessor in the socket, use the hex wrench provided with the microprocessor option to close and open the socket lock to observe the locking flag in the locked position. Also, note the resistance of the locking mechanism in the locked position. If you need better light to see the microprocessor socket lock clearly, shine a flashlight over the microprocessor connector. When installing the microprocessor, do not force the socket lock clockwise beyond the locked position. 2) Ensure that the microprocessor is aligned and seated correctly before you proceed. To avoid bending the pins on the microprocessor, do not use excessive force when pressing it into the socket. e. Insert the microprocessor gently into the connector. The microprocessor rests flat on the retention mechanism when properly seated.

f. Lock the socket lock, using the hex wrench provided with the microprocessor option. g. Tighten the heat-sink screws to secure the microprocessor, using the T-handled Torx wrench provided with the microprocessor option. h. Slide the power module gently into the microprocessor. i. Tighten the power-module screws to secure the power module. j. Plug the power-module cable into the power module and into the adjacent power-module cable connector.

IBM 8688 — Installing and replacing a microprocessor and power module diagram (page 116)
Abb. 52 · Installing and replacing a microprocessor and power…
Page 117 of the IBM 8688 user manual — Replacing fan 1 or 2
Seite 117 · Zum Vergrößern klicken
Seite 117
8. Carefully install the processor-board assembly and retention bracket. 9. Carefully install the memory-board assembly. 10. If you have other options to install or remove, do so now. Otherwise, go to “Completing the installation” on page 111.

Replacing and troubleshooting fans

Your xSeries 450 server has two hot-swap 150 mm x 51 mm fans and two hot-swap 150 mm x 38 mm fans. The two 150 mm x 51 mm fans (fan 1 and fan 2) are located toward the front of the server and are used to cool the memory board and processor board. The two 150 mm x 38 mm fans (fan 3 and fan 4) are located just behind the PCI-X board and are used to cool the power supplies, PCI-X slots, and other components.

Each fan has an LED to help you detect a problem. When the fan is operating correctly, this LED is off. If a fan stops working, the Light Path Diagnostics feature will light the system-error LED on the front of the server, indicating that there is a problem, and guide you to the defective fan. When this occurs, first identify the defective fan; then, using the appropriate procedure, remove and replace the fan.

Replacing fan 1 or 2

Fans 1 and 2 are located on the right side of the server. These fans are redundant, meaning that if one fails, the remaining fan will temporarily speed up to properly cool the server components.

Complete the following steps to replace fan 1 or 2: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Place your fingers into the two finger holes on the top of the fan, and squeeze them together; then, lift the fan out of the server. 3. Turn the new fan so that the LED on the top of the fan is to the right side of the server.

Chapter 4. Installing options 107

Page 118 of the IBM 8688 user manual — Replacing fan 3 or 4
Seite 118 · Zum Vergrößern klicken
Seite 118
4. Push the replacement fan assembly into the server until it clicks into place.
IBM 8688 — Replacing fan 3 or 4 diagram (page 118)
Abb. 53 · Replacing fan 3 or 4
5. If you have other options to install or remove, do so now. 6. Close the server cover (see “Closing the cover” on page 111).

Replacing fan 3 or 4

Fan 3 and fan 4 are located in front of the PCI-X slots. These fans are redundant, meaning that if one fails, the remaining fan will temporarily speed up to properly cool server components.

Complete the following steps to replace fan 3 or 4:

1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. 2. Press the latch release to the right, and let the handle come up. 3. Grasp the handle, and lift the fan out of the server.
4. Turn the new fan so that the latch release on the top of the fan is to the right side of the server. 5. With the handle raised, push the replacement fan assembly into the server until it clicks into place.

Fan 2

Page 119 of the IBM 8688 user manual — Replacing the battery
Seite 119 · Zum Vergrößern klicken
Seite 119
6. Push the handle down until it clicks into place under the latch release.
IBM 8688 — Replacing the battery diagram (page 119)
Abb. 54 · Replacing the battery
7. If you have other options to install or remove, do so now. 8. Close the server cover (see “Closing the cover” on page 111).

Replacing the battery

When replacing the battery, you must replace it with a lithium battery of the same type, from the same manufacturer. To avoid possible danger, read and follow the safety statement below.

To order replacement batteries, call 1-800-772-2227 within the United States, and 1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada, call your IBM reseller or IBM marketing representative.

system date and time.

Chapter 4. Installing options 109

Fan 2

Page 120 of the IBM 8688 user manual — Replacing the battery
Seite 120 · Zum Vergrößern klicken
Seite 120

Statement 2:

Do notv Throw or immerse into water

v Heat to more than 100°C (212°F) v Repair or disassemble

Dispose of the battery as required by local ordinances or regulations.

Complete the following steps to replace the battery: 1. Read the safety information beginning on page 197 and “Installation guidelines” on page 77. Follow any special handling and installation instructions supplied with the replacement battery. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables from the server; then, open the cover (see “Opening the cover” on page 88 for details). 3. Remove fans 3 and 4 from the server (see “Replacing fan 3 or 4” on page 108 for details). 4. Remove the battery: a. Use one finger to press the top of the battery clip away from the battery. b. Lift and remove the battery from the socket.

5. Insert the new battery: a. Use one finger to press the top of the battery clip away from the battery. b. Press the battery into the socket until it clicks into place. Make sure that the battery clip holds the battery securely.
Page 121 of the IBM 8688 user manual — Connecting the cables
Seite 121 · Zum Vergrößern klicken
Seite 121
6. Install fans 3 and 4 in the server (see “Replacing fan 3 or 4” on page 108 for details). 7. Close the server cover, and connect the cables. 8. Turn on the server. 9. Start the Configuration/Setup Utility program, and set configuration parameters. v Set the system date and time.

v Set the power-on password. v Reconfigure your server.

Completing the installation

To complete your installation, close the server cover, reconnect all cables that you disconnected earlier and, for certain options, run the Configuration/Setup Utility program. Follow the instructions in this section.

Closing the cover

Close the cover by first closing the right side; then, close the left side and press down to latch the two halves of the cover in place.

IBM 8688 — Closing the cover diagram (page 121)
Abb. 55 · Closing the cover

Connecting the cables

Chapter 4. Installing options 111

Page 122 of the IBM 8688 user manual — Updating your server configuration
Seite 122 · Zum Vergrößern klicken
Seite 122
3. If you have just plugged the power cords of the server into an electrical outlet, you must wait 30 seconds before pressing the power-control button.

The following illustration shows the locations of the input and output connectors on your server. See page 6 for descriptions of the I/O connectors.

RXE Expansion Port (B) connector

System power connector (1)

System power connector (2)

Remote Supervisor Adapter connectors

USB 2 connector USB 1 connector RXE Management Port connector

RXE Expansion Port (A) connector

Updating your server configuration

When you start your server for the first time after you add or remove an internal option or an external SCSI device, you might see a message telling you that the configuration has changed (see “Using the Configuration/Setup Utility program” on page 12).

Some options have device drivers that you need to install. See the documentation that comes with your option for information about installing any required device drivers.

If your server comes with two microprocessors or if your server comes with one microprocessor and you have installed one or more additional microprocessors, your server can now operate as an SMP server. Therefore, you might need to upgrade your operating system to support SMP. See the User’s Guide on the IBM xSeries Documentation CD and your operating-system documentation for additional information.

If you have a RAID configuration on your server using the integrated SCSI controller and you have installed or removed a hard disk drive, you might need to reconfigure your disk arrays. See the RAID documentation on the IBM xSeries Documentation CD for information about reconfiguring your disk arrays.

If you install a different type of RAID adapter in your server, use the configuration method supplied with the RAID adapter to view or change SCSI settings for attached devices.

The internal hard disk drives can connect only to the integrated SCSI controller with RAID capabilities.

Show 4 more labels / short text on this page
Serial connector · Gigabit Ethernet connectors · SCSI connector · Video connector
Page 123 of the IBM 8688 user manual — Installing the server in a rack
Seite 123 · Zum Vergrößern klicken
Seite 123

Installing the server in a rack

Detailed cabling instructions, including the use of the cable management arm (which comes with the server) are in the Rack Installation Instructions provided with the server.

Chapter 4. Installing options 113

Page 124 of the IBM 8688 user manual — Installing the server in a rack
Seite 124 · Zum Vergrößern klicken
Seite 124
Page 124 of the IBM 8688 user manual — Installing the server in a rack
Page 125 of the IBM 8688 user manual — Memory board
Seite 125 · Zum Vergrößern klicken
Seite 125

Chapter 5. Field replaceable units

The following information describes procedures for removing and installing certain components inside the system. Only a qualified service technician is authorized to replace the components described in this section.

servicers who are familiar with IBM xSeries products.

“Safety information” on page 197.

Memory-board assembly

The memory-board assembly consists of the memory board, memory, memory-board VRM, and the memory switch card and cable. The following sections describe how to remove the memory board, memory-board VRM, and the memory switch card and cable. For instructions to remove and replace memory, see “Installing memory” on page 98.

Memory board

the latest firmware or restore the pre-existing firmware that the customer provides on a CD image. See “Updating the firmware” on page 39.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to replace a memory board: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the cover (see “Opening the cover” on page 88).

© Copyright IBM Corp. 2003 115

Page 126 of the IBM 8688 user manual — Memory-board voltage regulator module (VRM)
Seite 126 · Zum Vergrößern klicken
Seite 126
3. Pull open the memory-board retaining latches, and remove the memory-board assembly.
IBM 8688 — Memory-board voltage regulator module (VRM) diagram (page 126)
Abb. 56 · Memory-board voltage regulator module (VRM)
4. Set the memory-board assembly on a static-free, clean work surface, and remove the DIMMs and VRMs that will be reused. See “Installing memory” on page 98. 5. Remove the memory board from the memory-board assembly.
6. Install the DIMMs and VRMs that were removed in step 4 into the new board. 7. Reinstall the memory board. 8. Reinstall the memory-board assembly.

information changes. Therefore, you must change and save the new configuration information by using the Configuration/Setup Utility program (see “Starting the Configuration/Setup Utility program” on page 12).

Memory-board voltage regulator module (VRM)

This section contains instructions for removing and replacing memory-board VRMs.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

To remove a voltage regulator module (VRM) from the memory board, complete the following steps: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the DIMM access door that covers the memory-board VRM that you are removing.

Page 127 of the IBM 8688 user manual — Memory-board voltage regulator module (VRM)
Seite 127 · Zum Vergrößern klicken
Seite 127
3. Pull the VRM-retention latches apart, and lift the VRM out of the memory-board VRM connector.
IBM 8688 — Memory-board voltage regulator module (VRM) diagram (page 127)
Abb. 57 · Memory-board voltage regulator module (VRM)
4. Close the DIMM access door.

To replace the memory-board VRM, complete the following steps:

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the DIMM access door that covers the memory-board VRM connector into which you will be installing the VRM. 3. Open the retaining clip on each end of the VRM connector. 4. Touch the static-protective package containing the VRM to any unpainted metal surface on the server. Then, remove the VRM from the package. Attention: To avoid breaking the retaining clips or damaging the VRM connectors, open and close the clips gently. 5. Turn the VRM so that the VRM keys align correctly with the slot, and insert the VRM into the connector by aligning the edges of the VRM with the slots at the ends of the VRM connector. Firmly press the VRM straight down into the connector by applying pressure on both ends of the VRM simultaneously. The retaining clips snap into the locked position when the VRM is firmly seated in the connector. If there is a gap between the VRM and the retaining clips, the VRM has not been correctly inserted; open the retaining clips, remove the VRM, and then reinsert it.

IBM 8688 — Memory-board voltage regulator module (VRM) diagram (page 127)
Abb. 58 · Memory-board voltage regulator module (VRM)
6. Close the DIMM access door.

Chapter 5. Field replaceable units 117

Page 128 of the IBM 8688 user manual — Memory switch card and cable
Seite 128 · Zum Vergrößern klicken
Seite 128

Memory switch card and cable

To remove the memory switch card and cable from the xSeries 450 server, complete the following steps:

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Remove the memory-board assembly. See “Memory board” on page 115.
3. Remove the cover from the memory-board assembly. 4. Disconnect the memory switch card cable from the memory switch card.
5. Remove the memory switch card from the cover of the memory-board assembly.
IBM 8688 — Memory switch card and cable diagram (page 128)
Abb. 59 · Memory switch card and cable
6. To replace the memory switch card and cable, reverse the steps.
Page 129 of the IBM 8688 user manual — Processor-board assembly
Seite 129 · Zum Vergrößern klicken
Seite 129

Processor-board assembly

This section contains instructions for removing the processor-board assembly, the microprocessor and power module, and the processor-board VRM.

server with the latest firmware or restore the pre-existing firmware that the customer provides on a CD image. See “Updating the firmware” on page 39.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to replace a processor-board assembly:

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the cover (see “Opening the cover” on page 88). 3. Pull open the memory-board retaining latches, and remove the memory-board assembly. See “Memory board” on page 115 for details. 4. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server.
IBM 8688 — Processor-board assembly diagram (page 129)
Abb. 60 · Processor-board assembly

Chapter 5. Field replaceable units 119

Page 130 of the IBM 8688 user manual — Processor-board assembly
Seite 130 · Zum Vergrößern klicken
Seite 130
5. Remove the processor-board assembly from the server: a. Press to unlock the levers securing the processor-board assembly, and pull up on the levers to release the processor-board assembly. b. Slide the assembly toward the right side of the server. c. Carefully remove the processor-board assembly from the server, and place it on a static-free, clean work surface.
IBM 8688 — Processor-board assembly diagram (page 130)
Abb. 61 · Processor-board assembly

6. Set the processor-board assembly on a static-free, clean work surface, and remove the microprocessor assemblies and power modules that will be reused. See “Microprocessor and power module” on page 121. 7. Place the new processor-board assembly on a static-free, clean work surface, and install the microprocessors and power modules that were removed in the preceding step into the new processor board. See “Installing and replacing a microprocessor and power module” on page 100. 8. Reinstall the processor-board assembly in the server.

configuration information changes. Therefore, you must use the Configuration/Setup Utility program to change and save the new configuration information (see “Starting the Configuration/Setup Utility program” on page 12). 9. Reinstall the retention bracket. 10. Replace the two shipping thumbscrews. 11. Reinstall the memory-board assembly.

Levers

Page 131 of the IBM 8688 user manual — Microprocessor and power module
Seite 131 · Zum Vergrößern klicken
Seite 131

Microprocessor and power module

Before you begin: v Read “Installation guidelines” on page 77.

v Read the safety notices at “Safety notices (multilingual translations)” on page 201.

v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove a microprocessor:

1. Turn off the server and peripheral devices, and disconnect the power cords and all external cables; then, open the cover. 2. Pull open the memory-board retaining latches, and remove the memory-board assembly. See “Memory board” on page 115 for details. 3. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server.
4. Remove the processor-board assembly from the server, and place it on a static-free, clean work surface. See “Processor-board assembly” on page 119 for details. 5. Remove the microprocessor and power module:

a. Using the T-handled Torx wrench provided with the microprocessor FRU, completely loosen the power-module screws.

b. Slide the power module from the microprocessor, and remove the power module.

c. Completely loosen the heat-sink screws. d. Use the hex wrench provided with the microprocessor FRU to open the socket lock, and remove the heat sink and microprocessor.

6. Replace the microprocessor and power module. See “Installing and replacing a microprocessor and power module” on page 100 for instructions.
7. Carefully install the processor-board assembly. See “Processor-board assembly” on page 119 for instructions. 8. Reinstall the retention bracket, and replace the two shipping thumbscrews.

Chapter 5. Field replaceable units 121

Microprocessor · Power module

Page 132 of the IBM 8688 user manual — Processor-board VRM
Seite 132 · Zum Vergrößern klicken
Seite 132
9. Carefully install the memory-board assembly. See “Memory board” on page 115 for instructions.

Processor-board VRM

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

To remove a VRM from the processor board, complete the following steps: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Pull open the memory-board retaining latches, and remove the memory-board assembly. See “Memory board” on page 115 for details. 3. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 4. Remove the processor-board assembly. See “Processor-board assembly” on page 119.

5. Pull the VRM-retention latches apart, and lift the VRM out of the processor-board VRM connector.
IBM 8688 — Processor-board VRM diagram (page 132)
Abb. 62 · Processor-board VRM

To replace the processor-board VRM, complete the following steps: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Remove the memory-board assembly. See “Memory board” on page 115 for details. 3. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 4. Remove the processor-board assembly. See “Processor-board assembly” on page 119. 5. Open the retaining clip on each end of the VRM connector. 6. Touch the static-protective package containing the VRM to any unpainted metal surface on the server. Then, remove the VRM from the package.

Page 133 of the IBM 8688 user manual — PCI-X board assembly
Seite 133 · Zum Vergrößern klicken
Seite 133

Attention: To avoid breaking the retaining clips or damaging the VRM connectors, open and close the clips gently. 7. Turn the VRM so that the VRM keys align correctly with the slot. 8. Insert the VRM into the connector by aligning the edges of the VRM with the slots at the ends of the VRM connector. Firmly press the VRM straight down into the connector by applying pressure on both ends of the VRM simultaneously. The retaining clips snap into the locked position when the VRM is firmly seated in the connector. If there is a gap between the VRM and the retaining clips, the VRM has not been correctly inserted; open the retaining clips, remove the VRM, and then reinsert it.

IBM 8688 — PCI-X board assembly diagram (page 133)
Abb. 63 · PCI-X board assembly

PCI-X board assembly

The PCI-X board assembly contains the following components: v Active PCI assembly v Midplane board v I/O board v PCI and PCI-X adapters and spacers v PCI-X board

v Riser card v Remote Supervisor Adapter v VRMs

The PCI-X board assembly must be removed from the server to access many of these components.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the PCI-X board assembly from the server:

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables.
2. Remove the front bezel. See “Removing and replacing the bezel” on page 89.

Chapter 5. Field replaceable units 123

Page 134 of the IBM 8688 user manual — PCI-X board assembly
Seite 134 · Zum Vergrößern klicken
Seite 134

3. Remove the power supplies. See “Removing and replacing a hot-swap power supply” on page 90. 4. Open the top cover (see “Opening the cover” on page 88). 5. Remove fans 1 and 2 (see “Replacing fan 1 or 2” on page 107). 6. Remove the memory-board assembly. See “Memory board” on page 115 for details. 7. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 8. Remove the processor-board assembly. See “Processor-board assembly” on page 119 for details. 9. If the system contains a removable cable retainer, turn the thumbscrew to remove it. 10. Disconnect all cables attached to the PCI-X board assembly1. 11. Remove the shipping thumbscrews from the left side of the server, if installed2. 12. Disconnect the cables to the hard disk drive backplane (see “Hard disk drive backplane” on page 138).

in the PCI-X board assembly becoming entangled in these cables at step 14.

13. Pivot the release handle 3 . 14. Slide the PCI-X board assembly as far forward as possible, and then slightly to the right 4 .
15. Disconnect the PCI hot-swap cable, and lift the PCI-X board assembly straight up and out of the server 5 .
IBM 8688 — PCI-X board assembly diagram (page 134)
Abb. 64 · PCI-X board assembly
16. To reinstall the PCI-X board assembly, reverse these steps.

connect with seven slots on the bottom of the chassis and two slots on the side of the chassis. Line up the tabs on the PCI-X board assembly with the slots on the chassis, and then slide the PCI-X board assembly into place.

Page 135 of the IBM 8688 user manual — Midplane board
Seite 135 · Zum Vergrößern klicken
Seite 135
IBM 8688 — Midplane board diagram (page 135)
Abb. 65 · Midplane board

Midplane board

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the midplane board: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the top cover (see “Opening the cover” on page 88). 3. Remove the memory-board assembly. See “Memory board” on page 115 for details. 4. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 5. Remove the processor-board assembly. See “Processor-board assembly” on page 119 for details. 6. Remove the PCI-X board assembly from the server (see “PCI-X board assembly” on page 123), and place it on a clean work surface.

Chapter 5. Field replaceable units 125

Page 136 of the IBM 8688 user manual — Midplane-board VRM
Seite 136 · Zum Vergrößern klicken
Seite 136
7. Remove the midplane board by turning the two midplane thumbscrews ( 1 ) to release it; then, carefully pull the midplane board out of its socket ( 2 ).
IBM 8688 — Midplane-board VRM diagram (page 136)
Abb. 66 · Midplane-board VRM
8. To replace the midplane board, reverse the previous steps.

Midplane-board VRM

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

To remove the VRM from the midplane board, complete the following steps: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the top cover (see “Opening the cover” on page 88).

3. Remove the memory-board assembly. See “Memory board” on page 115 for details. 4. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 5. Remove the processor-board assembly. See “Processor-board assembly” on page 119 for details. 6. Remove the PCI-X board assembly from the server (see “PCI-X board assembly” on page 123), and place it on a clean work surface. 7. Press down on the VRM-retention bar, and release the VRM-retention bar.

Page 137 of the IBM 8688 user manual — PCI-X board
Seite 137 · Zum Vergrößern klicken
Seite 137
8. Pull the VRM from the midplane-board VRM connector.
IBM 8688 — PCI-X board diagram (page 137)
Abb. 67 · PCI-X board
9. To replace the midplane-board VRM, reverse the steps.

PCI-X board

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the PCI-X board:

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the top cover (see “Opening the cover” on page 88). 3. Remove the memory-board assembly. See “Memory board” on page 115 for details. 4. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 5. Remove the processor-board assembly. See “Processor-board assembly” on page 119 for details. 6. Remove the PCI-X board assembly from the server (see “PCI-X board assembly” on page 123), and place it on a clean work surface.

Chapter 5. Field replaceable units 127

Page 138 of the IBM 8688 user manual — PCI-X board
Seite 138 · Zum Vergrößern klicken
Seite 138

7. Remove the PCI-X board assembly from the I/O board: a. Remove any adapters and adapter separators that are installed (see “Installing an adapter” on page 92), disconnecting any necessary cables. b. Remove the midplane board by turning the two midplane board thumbscrews to release it; then, carefully lift the midplane board out of its socket, and place it on a static-free, clean work surface. c. Release the PCI-X board assembly from the I/O board at the four notches that secure them together; then, lift the PCI-X board assembly off of the I/O board, and set it on a safe, clean work surface.

IBM 8688 — PCI-X board diagram (page 138)
Abb. 68 · PCI-X board
8. Remove any cables that are attached to the PCI-X board.

PCI-X Assembly · I/O Board

Page 139 of the IBM 8688 user manual — Active PCI assembly
Seite 139 · Zum Vergrößern klicken
Seite 139
9. Remove the six screws that fasten the PCI-X board to the assembly.
IBM 8688 — Active PCI assembly diagram (page 139)
Abb. 69 · Active PCI assembly
10. Lift the board up and out of the PCI-X board assembly. 11. To replace the PCI-X board, reverse the previous steps.

Active PCI assembly

The Active PCI assembly, mounted on the top rear of the server frame adjacent to the PCI and PCI-X adapters, contains one switch for each of the six adapters. This ensures that power is disconnected from the associated adapter if you attempt to open the adapter latch and remove an adapter.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to replace the Active PCI assembly: 1. Turn off the server, and disconnect all power cords and external cables; then, remove the top cover (see “Opening the cover” on page 88). 2. Disconnect the Active PCI assembly cable from the server.

Chapter 5. Field replaceable units 129

Page 140 of the IBM 8688 user manual — I/O board, riser card, and Remote Supervisor Adapter
Seite 140 · Zum Vergrößern klicken
Seite 140
3. Grasp the two adapter switch card release latches, and slide the assembly away from the server chassis; then, lift it out of the server.
IBM 8688 — I/O board, riser card, and Remote Supervisor Adapter diagram (page 140)
Abb. 70 · I/O board, riser card, and Remote Supervisor Adapter
4. To replace the Active PCI assembly, lower the assembly into place so that the lips on the bottom of the EMI shielding material fit into the chassis at the rear of the server, and slide the card into place until the two release latches snap securely. Then, connect the cable from the Active PCI assembly to the board.
5. Close the top cover (see “Closing the cover” on page 111).

I/O board, riser card, and Remote Supervisor Adapter

This section contains instructions and considerations for removing and replacing the I/O board, the riser card, and the Remote Supervisor Adapter.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Attention: The EFI in the xSeries 450 stores its variables with nonvolatile attributes in NVRAM on the Remote Supervisor Adapter. Before you remove or replace the Remote Supervisor Adapter or clear the NVRAM, make a backup copy of the current nonvolatile variables stored in the NVRAM on the Remote Supervisor Adapter. After you install a new Remote Supervisor Adapter, you must restore the EFI variables previously stored in the NVRAM. The EFI variables stored in the NVRAM on the Remote Supervisor Adapter include the following: v Console definitions

v Startup options and drivers v Startup order and timeout

Page 141 of the IBM 8688 user manual — I/O board, riser card, and Remote Supervisor Adapter
Seite 141 · Zum Vergrößern klicken
Seite 141

Complete the following steps to create a backup copy of the EFI variables.

1. Ensure that the formatted media where you plan to store the backup file is installed, and start the server. 2. From the EFI Boot Manager, select EFI Shell [Built-In] , and press Enter.

startup configuration. Contact the system administrator for further instructions. 3. In the Shell prompt, type map -b, and press Enter. 4. Look for a file system to which you can write backup file information, and note the file system number (fsn:, where n is the number of the file system). The following character string will be displayed in the middle of the line: Scsi. 5. At the Shell prompt, type fsn:, and press Enter. The prompt changes to fsn:\. 6. Type the following EFI command to create a backup copy of the EFI variables:

(Where filename is the name you want to assign to the backup copy, for example, efibskup.001), and press Enter.

Completed - Success 7. Type one of the following EFI commands to verify that the backup file was created successfully: dir or ls.

Complete the following steps to remove the I/O board, riser card, or Remote Supervisor Adapter:

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the top cover (see “Opening the cover” on page 88).

3. Remove the memory-board assembly. See “Memory board” on page 115 for details. 4. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 5. Remove the processor-board assembly. See “Processor-board assembly” on page 119 for details. 6. Remove the PCI-X board assembly from the server (see “PCI-X board assembly” on page 123), and place it on a clean work surface. 7. Remove the midplane board by turning the two midplane thumbscrews to release it (see “Midplane board” on page 125); then, carefully lift the midplane board out of its socket, and place it on a static-protective surface.

Chapter 5. Field replaceable units 131

backup filename

Page 142 of the IBM 8688 user manual — I/O board, riser card, and Remote Supervisor Adapter
Seite 142 · Zum Vergrößern klicken
Seite 142
8. Remove the PCI-X board assembly from the I/O board: a. Remove any adapters and adapter separators that are installed (see “Installing an adapter” on page 92), unplugging any necessary cables. b. Release the PCI-X board assembly from the I/O board at the four notches that secure them together, then lift the PCI-X board assembly off of the I/O board and set it in a safe place.
IBM 8688 — I/O board, riser card, and Remote Supervisor Adapter diagram (page 142)
Abb. 71 · I/O board, riser card, and Remote Supervisor Adapter
9. Remove the VRM from the I/O board. 10. Remove all screws securing serial ports and video connectors to the back of the I/O board assembly. 11. Remove the eight screws securing the I/O board to the I/O board assembly, and slide the I/O board approximately 1 in. (2.54 cm) forward.

PCI-X Assembly · I/O Board

Page 143 of the IBM 8688 user manual — I/O board, riser card, and Remote Supervisor Adapter
Seite 143 · Zum Vergrößern klicken
Seite 143
12. Remove the Remote Supervisor Adapter from the riser card, disconnecting any cables, and set it in a safe place.
IBM 8688 — I/O board, riser card, and Remote Supervisor Adapter diagram (page 143)
Abb. 72 · I/O board, riser card, and Remote Supervisor Adapter

Screws from video port

13. Remove the riser card from the I/O board, disconnecting any cables.
IBM 8688 — I/O board, riser card, and Remote Supervisor Adapter diagram (page 143)
Abb. 73 · I/O board, riser card, and Remote Supervisor Adapter

Screws from serial port

14. To replace the I/O board, reverse the previous steps. 15. Restart the server; then, update the firmware (see “Updating the firmware” on page 39).

If you cannot restart the server after updating the firmware, complete the following steps:

1. Attach an ANSI terminal emulator to the serial port of the Remote Supervisor Adapter of the server using a null modem cable. Use communications settings of 57600 baud, 8 data bits, no parity, 1 stop bit, no flow control. 2. Press Esc to access the login screen on the ANSI terminal emulator. A login window is displayed.

Chapter 5. Field replaceable units 133

SCSI cable · I/O board

Page 144 of the IBM 8688 user manual — Restoring the nonvolatile EFI variables
Seite 144 · Zum Vergrößern klicken
Seite 144
3. In the Login ID prompt, type USERID . 4. In the Password prompt, type PASSW0RD . 5. Select Settings , and press Enter.
6. Select Network Interfaces/Protocols , and press Enter. 7. Select Ethernet , and press Enter.
8. Select IP Configuration Assigned by DHCP server , and press Enter. 9. Note the IP address on the IP Configuration Assigned by DHCP server screen.

10. Assign a static IP address to the server: a. Open an Internet browser, such as Microsoft Internet Explorer. b. Type the IP address that you noted in step 9, and click OK. A prompt asking for your user ID and password is displayed. c. Type USERID and PASSW0RD, and click OK. The Advanced System Management Welcome screen is displayed. d. Set the timeout options that you want, and click Continue. e. Click Network Interface. f. Disable DHCP, and assign a static IP address in the IP address field; then, click Save. g. Click OK.

11. Update the Remote Supervisor Adapter firmware: a. From the Advanced System Management Welcome screen, click the Firmware Update link. b. Click Browse to locate the following firmware files: v The boot ROM file: cnetbrus.pkt v The main application file: cnetmnus.pkt v The remote graphics file: cnetrgus.pkt

c. Click Update. d. Click OK. e. Repeat steps 11a through 11d for each firmware file.

12. Click Restart ASM to restart the Remote Supervisor Adapter. 13. Logoff the Advanced System Management utility, and exit Internet Explorer. 14. Remove the ANSI terminal emulator from the serial port of the server, and turn on the server.

Restoring the nonvolatile EFI variables

You might need to manually restore the nonvolatile EFI variables after replacing the Remote Supervisor Adapter. To restore the nonvolatile EFI variables after replacing the Remote Supervisor Adapter, complete the following steps: 1. Ensure that the formated media where you plan to store the backup file is installed, and start the server. 2. From the EFI Boot Manager menu, select EFI Shell [Built-In], and press Enter.

startup configuration. Contact the system administrator for further instructions. 3. At the Shell prompt, type map -b, and press Enter. 4. Look for a file system in which you can locate the backup file, and note the file system number (fsn:, where n is the number of the file system).

5. At the Shell prompt, type fs n : , and press Enter. The prompt changes to fs n :\ .
Page 145 of the IBM 8688 user manual — Restoring the nonvolatile EFI variables
Seite 145 · Zum Vergrößern klicken
Seite 145
6. Type restore filename (where filename is the name you assigned to the backup copy), and press Enter. The following message is displayed:

Delete existing non-volatile efi variables? [y/n] 7. Type y, and press Enter. If the SAL/EFI settings have been restored, the following message is displayed:

Completed - Success 8. Type reset, and press Enter.

If SAL/EFI settings were not backed up, use one of the following procedures to restore settings for your operating system.

To restore Microsoft Windows 2003 Server startup options, complete the following steps:

1. From the EFI Boot Manager menu, select EFI Shell [Built-In], and press Enter. 2. At the Shell prompt, type map -b, and press Enter. 3. Look for a file system where the following directory is located: fsn:\EFI\Microsoft\WINNTnn, note the file system number (fsn:, where n is the number of the file system), and find the startup (Bootnnnn) file. 4. Note the name of the startup file. 5. At the Shell prompt, type fsn:, and press Enter. The prompt changes to fsn:\. 6. Type cd EFI\MSUtil\, and press Enter. 7. Type nvrboot, and press Enter. 8. In the Select prompt, type I, and press Enter. 9. Type the Import file path, and press Enter. The following message is displayed:

Imported Boot Options from file: press Enter to Continue. 10. Press Enter. 11. Type q, and press Enter. 12. Exit the EFI Shell; then, return to the EFI Boot Manager. 13. Select Boot Options Maintenance Menu, and press Enter. 14. If the server has multiple options of Windows, repeat steps 3 through 13 for each startable Windows installation. 15. Select Manage BootNext, if necessary, and press Enter; then, select Save Settings to NVRAM, and press Enter. 16. Select Delete Boot Options, if necessary, and press Enter; then, select Save Settings to NVRAM, and press Enter. 17. Select Change Boot Order, if necessary, and press Enter; then, select Save Settings to NVRAM, and press Enter. 18. Return to the EFI Boot Manager to start the startup option that you want.

To restore SuSE Linux startup options, complete the following steps:

1. From the EFI Boot Manager menu, select Boot option maintenance menu , and press Enter. 2. Select Add a Boot Option , and press Enter. 3. Select a volume for the EFI System Partition for SuSE Linux. The volume for SuSE Linux should have \efi\SuSE directory in it. 4. Select efi , and press Enter. 5. Select SuSE , and press Enter.
6. Select elilo.efi , and press Enter.

Chapter 5. Field replaceable units 135

Page 146 of the IBM 8688 user manual — Restoring the nonvolatile EFI variables
Seite 146 · Zum Vergrößern klicken
Seite 146

7. At the Type a New Description prompt, type the description of the startup option you want to appear in the Boot option maintenance menu. 8. Type n if there are no customized startup options. 9. Type y to save changes to NVRAM. 10. If the server has multiple options of SuSE Linux, repeat steps 3 on page 135 through 9 for each startable Linux installation. 11. Select Exit, and press Enter to return to the Boot option maintenance menu. 12. Select Exit, and press Enter to return to the EFI Boot Manager menu.

To restore console configuration settings, complete the following steps: 1. From the EFI Boot Manager menu, select Boot options maintenance menu, and press Enter. 2. Select Active Console Output, and press Enter to display available devices. 3. Select the devices that you want using the arrow keys, and press Enter. You can select more than one device as active. 4. Select Save Settings to NVRAM, and press Enter.

5. Select Exit , and press Enter to return to the Boot options maintenance menu. 6. Repeat steps 2 through 5 for Active Console Input and Active Error Output. 7. Select Exit , and press Enter to return to the EFI Boot Manager menu. 8. The settings will be active the next time you start up the server.

To restore all other startup options, complete the following steps: 1. From the EFI Boot Manager, select Boot option maintenance menu, and press Enter. 2. Select Add a Boot Option, and press Enter. 3. Select a volume for the EFI System Partition for the volume that you want or its directory and file. 4. At the Type a New Description prompt, type the description of the startup option you want to appear in the Boot option maintenance menu. 5. Type n if there are no customized startup options for Linux. 6. Type y to save changes to NVRAM. 7. Select Exit, and press Enter to return to the Boot option maintenance menu.

8. Select Exit , and press Enter to return to the EFI Boot Manager menu.

To restore any driver options, complete the following steps: 1. From the EFI Boot Manager, select EFI Shell [Built-In], and press Enter.

2. Type bcfg to add, remove, or move any driver options, if necessary.

To restore active console devices, complete the following steps: 1. From the EFI Boot Manager, select Boot option maintenance menu, and press Enter. 2. Select Active Console Output, Console Input, and Standard Error Devices.

device is selected as active, only selected devices are used. You can select multiple devices as active. Hot-plug devices are always active. 3. Select the active devices that you want; then, select Save Settings to NVRAM, and press Enter. 4. Cold reset or connect -c from the EFI shell for changes to take effect.

Page 147 of the IBM 8688 user manual — Top cover assembly
Seite 147 · Zum Vergrößern klicken
Seite 147

device is selected as active, only selected devices are used. You can select multiple devices as active. Hot-plug devices are always active.

For instructions to restore a remote-control password, see “Configuring the remote-control password” on page 25.

Top cover assembly

This section contains instructions for removing and replacing the top cover assembly.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the top cover assembly. 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Remove the front bezel (see “Removing and replacing the bezel” on page 89).

3. Pull the two retaining pins on the top front of the chassis until they loosen. 4. Slide the top cover to the front slightly. 5. Pull the cover up, and remove it from the server.
IBM 8688 — Top cover assembly diagram (page 147)
Abb. 74 · Top cover assembly

To replace the top cover assembly, complete the following steps: 1. Align the three notches on each side of the cover with the slots in the top of the chassis. 2. Push the cover toward the rear. 3. Push in on the two retaining pins.

4. Replace the front bezel.

Chapter 5. Field replaceable units 137

Page 148 of the IBM 8688 user manual — Hard disk drive backplane
Seite 148 · Zum Vergrößern klicken
Seite 148

Top power board

Before you begin:

v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the top power board. 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Remove the top cover assembly (see “Top cover assembly” on page 137), and set it upside-down on a clean work surface. 3. Remove the two screws securing the power board to the top cover.

4. Pull the power board away from the cover.
IBM 8688 — Top power board diagram (page 148)
Abb. 75 · Top power board
5. To install the top power board, reverse the above steps.

Hard disk drive backplane

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the hard disk drive backplane.

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the cover (see “Opening the cover” on page 88). 3. Remove the power supplies (see “Removing and replacing a hot-swap power supply” on page 90).
Page 149 of the IBM 8688 user manual — Media bay card
Seite 149 · Zum Vergrößern klicken
Seite 149
4. Remove the memory-board assembly (see “Memory board” on page 115 for details). 5. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 6. Remove the processor-board assembly (see “Processor-board assembly” on page 119 for details). 7. Remove the PCI-X board assembly (see “PCI-X board assembly” on page 123). 8. Grasp the edge of the hard disk drive backplane nearest the front of the server, and flip the backplane up.
IBM 8688 — Media bay card diagram (page 149)
Abb. 76 · Media bay card
9. Remove the backplane from the server. 10. To install the hard disk drive backplane, reverse the previous steps, making sure to align the pins in the hard disk drive backplane with the notches in the server chassis.

Media bay card

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the media bay card. 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the cover (see “Opening the cover” on page 88). 3. Remove the hard disk drive backplane (see “Hard disk drive backplane” on page 138).

Chapter 5. Field replaceable units 139

Page 150 of the IBM 8688 user manual — Memory-board retaining latches
Seite 150 · Zum Vergrößern klicken
Seite 150
4. Insert your fingers in the two thumb holes, and push toward the outside edges of the card until the card is released.
IBM 8688 — Memory-board retaining latches diagram (page 150)
Abb. 77 · Memory-board retaining latches
5. Pull the card out of the server. 6. To replace the media bay card, reverse the previous steps.

Memory-board retaining latches

This section contains instructions for removing the memory-board retaining latches from the processor-board assembly.

Before you begin: v Read “Installation guidelines” on page 77.

v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to replace the memory-board retaining latches:

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Open the cover (see “Opening the cover” on page 88). 3. Pull open the memory-board retaining latches, and remove the memory-board assembly. See “Memory board” on page 115 for details. 4. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 5. Remove the processor-board assembly from the server (see “Processor-board assembly” on page 119). 6. Set the processor-board assembly on a static-free, clean work surface. 7. Remove the screws securing the memory-board retaining latches to the processor-board assembly. 8. Remove the memory-board retaining latches and the retention spring from the processor-board assembly; then, remove the the locking slides from the processor-board assembly.

Finger holes

Page 151 of the IBM 8688 user manual — AC box assembly mechanism
Seite 151 · Zum Vergrößern klicken
Seite 151
9. Place the new locking slides in the processor-board assembly. 10. Place the new memory-board retaining latches and the retention spring, and secure them with the screws that you removed in step 7 on page 140.
IBM 8688 — AC box assembly mechanism diagram (page 151)
Abb. 78 · AC box assembly mechanism

configuration information changes. Therefore, you must use the Configuration/Setup Utility program to change and save the new configuration information (see “Starting the Configuration/Setup Utility program” on page 12).

11. Reinstall the processor-board assembly in the server. 12. Reinstall the retention bracket.
13. Replace the two shipping thumbscrews. 14. Reinstall the memory-board assembly.

AC box assembly mechanism

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the ac box assembly mechanism: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Remove the fans (see “Replacing fan 1 or 2” on page 107). 3. Remove the top cover assembly (see “Top cover assembly” on page 137).

Chapter 5. Field replaceable units 141

Sliding lock

Page 152 of the IBM 8688 user manual — AC box assembly mechanism
Seite 152 · Zum Vergrößern klicken
Seite 152

4. Open the top cover (see “Opening the cover” on page 88). 5. Remove the memory-board assembly (see “Memory board” on page 115 for details). 6. Remove the shipping thumbscrews from the right side of the server, and lift the retention bracket from the server. 7. Remove the processor-board assembly (see “Processor-board assembly” on page 119 for details). 8. Remove the PCI-X board assembly (see “PCI-X board assembly” on page 123). 9. Remove the two screws 1 that secure the ac box assembly mechanism to the chassis. 10. Remove the two screws 2 that secure the side panel to the chassis, and lift the panel away from the server. 11. Detach each of the two power connectors near the power supplies: a. Using a screwdriver, depress the two tabs on the connector.

b. Pull the connector toward the rear of the server and detach.

12. Detach the bundled power cable from the chassis: a. Pull the bundled power cable through the slot in the crossbar. b. Slide the two power connectors through the opening 3 on the side of the server.
13. Remove the ac box assembly from the server.
IBM 8688 — AC box assembly mechanism diagram (page 152)
Abb. 79 · AC box assembly mechanism
14. To install the ac box assembly, reverse the above steps.

a. Line up the tabs on the panel with the notches on the server, then slide the side panel towards the rear of the server.

b. Position the bundled cable towards the bottom of the panel before securing the panel. c. The screw nearest the rear of the server secures both the panel and the ac box assembly mechanism.

Page 153 of the IBM 8688 user manual — Media-extract mechanism
Seite 153 · Zum Vergrößern klicken
Seite 153

Media-extract mechanism

The server contains two media-extract mechanisms.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove a media-extract mechanism from the server: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables.

2. Remove the drive associated with the media-extract mechanism to be removed (see “Installing a 1.44 MB diskette drive” on page 96 or “Installing a CD-ROM or DVD-ROM drive” on page 97).
IBM 8688 — Media-extract mechanism diagram (page 153)
Abb. 80 · Media-extract mechanism
3. With a screwdriver, press the two notches on the media-extract mechanism until it pops free of the chassis. 4. Pull the media-extract mechanism out of the front of the server. 5. To install the media extract mechanism, reverse the above steps, sliding the media-extract mechanism into position until it snaps into place.

installed in the bay before sliding the media-extract mechanism into position.

Chapter 5. Field replaceable units 143

Page 154 of the IBM 8688 user manual — Light Path card
Seite 154 · Zum Vergrößern klicken
Seite 154

Power/reset card assembly

The power/reset card assembly is located on the left front of the server.

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the power/reset card assembly: 1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Remove the front bezel (see “Removing and replacing the bezel” on page 89). 3. Remove fans 3 and 4 to access the power/reset cable (see “Replacing fan 3 or 4” on page 108). 4. Disconnect the power/reset card cable from the I/O board.

IBM 8688 — Power/reset card assembly diagram (page 154)
Abb. 81 · Power/reset card assembly
5. Remove the screw that attaches the card to the chassis, and carefully set it aside. 6. Remove the card assembly from the server by drawing the cable through the channel in the side of the chassis and out the front.
7. To replace the card assembly, reverse the previous steps, threading the cable through the gap in the chassis.

Light Path card

Before you begin: v Read “Installation guidelines” on page 77. v Read the safety notices at “Safety notices (multilingual translations)” on page 201. v Read “Handling static-sensitive devices” on page 200.

Complete the following steps to remove the Light Path card:

1. Turn off the server (see “Turning off the server” on page 8), and disconnect all power cords and external cables. 2. Remove the two front fans (see “Replacing fan 1 or 2” on page 107). 3. Remove the front bezel (see “Removing and replacing the bezel” on page 89).
4. Open the cover (see “Opening the cover” on page 88).
Page 155 of the IBM 8688 user manual — Power/reset card assembly
Seite 155 · Zum Vergrößern klicken
Seite 155
5. Remove the top cover assembly (see “Top cover assembly” on page 137), and set it upside-down on a clean work surface. 6. Disconnect the Light Path cable from the midplane board (see “Midplane board connectors and LEDs” on page 84). 7. From the front of the server, grasp the edge of the Light Path card, push it in slightly to release the catch mechanism, and then pull it out until it tilts downward.
IBM 8688 — Power/reset card assembly diagram (page 155)
Abb. 82 · Power/reset card assembly
8. Inside the server, squeeze the Light Path card at the arrows to free it from the server. 9. Slide the card the rest of the way out of the server.
10. To replace the Light Path card, reverse the previous steps.

Chapter 5. Field replaceable units 145

Page 156 of the IBM 8688 user manual — Power/reset card assembly
Seite 156 · Zum Vergrößern klicken
Seite 156
Page 156 of the IBM 8688 user manual — Power/reset card assembly
Page 157 of the IBM 8688 user manual — Light Path LED errors
Seite 157 · Zum Vergrößern klicken
Seite 157

Chapter 6. Symptom-to-FRU index

This index supports xSeries 450 servers.

The Symptom-to-FRU index lists symptoms, errors, and the possible causes. The most likely cause is listed first. Use this Symptom-to-FRU index to help you decide which FRUs to have available when servicing the server.

The left-hand column of the tables in this index lists error codes or messages, and the right-hand column lists one or more suggested actions or FRUs to replace.

one column on the left is required to describe the error symptom. Take the action (or replace the FRU) suggested first in the list of the right-hand column, then try the server again to see if the problem has been corrected before taking further action.

replacing the component.

Light Path LED errors

The system-error LED on the operator information panel is lit when certain system errors occur. If the system-error LED on your server is lit, use the following table to help determine the cause of the error and the action you should take.

Before replacing any FRU: 1. Observe LEDs on boards. 2. View the system-error log.

3. Run AMIDiag program.

Level 2 Light Path LED FRU/action

None (An error has occurred and cannot be isolated, or the ASM processor has failed.)

An error has occurred that is not represented by a Light Path Diagnostics LED. Check the system-error log for more information about the error.

All LEDs off (error log full) Note: ″See Log″ LED might be lit.

1. System-error log is 75% full; clear the log.
2. PFA alert; check error log for failure; clear PFA alert; remove ac power for at least 20 seconds, reconnect, then turn on server.
3. Run diagnostics.

CPU LED on (failed processor) Note: Verify correct installation sequence; see “Installing and replacing a microprocessor and power module” on page 100.

1. See the system-error log.
2. Microprocessor 1-4. Note: To see microprocessor error LEDs, remove the processor-board assembly from the chassis, and press the LED activation switch.
3. Processor board.

© Copyright IBM Corp. 2003 147

Page 158 of the IBM 8688 user manual — Chapter 6. Symptom-to-FRU index
Seite 158 · Zum Vergrößern klicken
Seite 158

Level 2 Light Path LED FRU/action

MEM LED on (memory error) 1. Check DIMM error LED on memory board. Note: If there is a DIMM failure, an LED on the memory board indicates the failing DIMM. Reseat the failing DIMMs, re-enable the DIMMs using the Configuration/Setup Utility program, and run AMIDiag to pinpoint the failing DIMM.

2. DIMM.
3. Memory board.

DASD LED on (hot-swap hard drive failure) Note: If RAID system, refer to the Hardware Maintenance Manual for the specific RAID adapter.

1. Run the AMIDiag program.
2. Failing drive (reseat/replace).
3. Be sure the fans are operating correctly and the air flow is good.
4. SCSI backplane.

PCI-X BUS LED on (adapter failure)

1. Check the system-error log.
2. If there is a PCI-X slot available, move the adapter to an empty PCI-X slot, and restart the server.
3. Failing adapter.
4. PCI-X board.

FAN LED on (fan failure) Note: A failing fan can also cause the TEMP and DASD LEDs to be on.

1. Check individual fan LEDs.
2. Replace respective fan.
3. Front fan connectors.
4. I/O board.

TEMP LED on (temperature too high)

1. If a fan LED is on, replace the fan.
2. Ambient temperature must be within normal operating specifications. See “Features and specifications” on page 3.
3. Examine the system-error log. a. System over recommended temperature b. Operator information panel c. DASD over recommended temperature — overheating hard disk drive. d. System over temperature for processor x (where x is processor number) — microprocessor x . e. VRM LED on — failing VRM. f. Power supply fault / over temp — failing power supply

NMI (nonmaskable interrupt) Note: A PCI or MEM LED may also be on.

1. See the system-error log.
2. If a PCI LED is on, follow the instructions for that LED.
3. If a MEM LED is on, follow the instructions for that LED.
4. Restart the server.

Board LED on (system monitor detected an error on one of the six system boards (see system board LEDs 1-6 for additional location information)

1. Turn off the server and disconnect the ac power cord.
2. Wait at least 10 seconds before plugging in the ac power cord again, and restart the server.
3. Failed system board.

Event Log See the system-error log.

PS1 LED on 1. Power supply 1

2. Top power board
3. Midplane board

PS2 LED on 1. Power supply 2

2. Top power board
3. Midplane board
Page 159 of the IBM 8688 user manual — System-error log entries
Seite 159 · Zum Vergrößern klicken
Seite 159

Level 2 Light Path LED FRU/action

VRM LED on (VRM failure) 1. See the system-error log.

2. Microprocessor power module 1-4. Note: To see microprocessor error LEDs, remove the processor-board assembly from the chassis, and press the LED Activation switch.
3. VRM 1-4.
4. Midplane-board VRM.
5. Processor-board VRM.
6. Processor board.
7. Midplane board.

Non Redund (nonredundancy lost) 1. Connect the server to 220v ac if power redundancy is required.

2. If the PS x LED is lit on Level 2 Light Path, follow the instructions for that LED.
3. Replace failing power supply.

Over Spec (power supplies’ rating exceeded)

1. Ensure that ac power is applied to both power supplies.
2. Power supply.

VRM and memory LEDs on (memory board level 3 LED on)

1. Replace the failing VRM with lit LED, and re-enable any failed memory.
2. Memory board.
3. Midplane board.

Level 2 VRM LED on and board LED on

1. Processor-board VRM.
2. Remove all PCI adapters from the server.
3. PCI-X board VRM.
4. PCI-X board.

System-error log entries

The system-error log is similar to an event log and can contain messages of three major types:

Information Information messages do not require action and record significant system-level events. Example: ’System Complex Powered Up’

Error Error messages indicate system errors that may require attention. Example: ’Fan 2 not detected’

System-error log messages can originate from two sources. v SAL/EFI v Service processor

Each entry contains date and time information, which is useful in determining the nature of the occurrence.

Chapter 6. Symptom-to-FRU index 149

Page 160 of the IBM 8688 user manual — SAL/EFI messages
Seite 160 · Zum Vergrößern klicken
Seite 160

SAL/EFI messages

The following is an example of a typical SAL/EFI message:

- Log Entry #: 2 Logging Source: SAL/EFI Log Type: E, I, or W Date: 06/17/2003 Time: 6:17:3 Recoverable Error handling example message -

This message indicates that a SAL/EFI error occurred at the recorded time. The following table lists all of the error codes and the actions to take in the event of an error code.

Sometimes the first error to occur causes additional errors. In this case, the server displays more than one error message. Always follow the suggested action instructions for the first error message that appears.

In the following error codes, X can be any number or letter.

B113 (CMOS read/write failure) 1. Battery

2. I/O board

B114 (SAL/EFI ROM checksum or Boot error.) 1. Update system firmware.

2. I/O board.
B124 ( Memory boardController initialization failed.) Memory board

B231B (I/O card fault, Video initialization error.) I/O board

B3121 (I/O boardVideo: initialization error.) I/O board

062 (System failed three consecutive boot attempts.) 1. Update server to latest levels.

2. I/O board.
3. Processor board.
4. Processor.
129 (Processorx Internal cache error, removed from service.)

161 (CMOS battery failure.) Battery

162 (CMOS checksum error.) 1. Battery

2. I/O board

163 (Time or Date Error.) 1. Set time of day using the Configuration/Setup Utility program.

2. Battery.
3. I/O board.
175 (I/O Card FaultBad EEPROM CRC#1.) I/O board
178 (I/O Card FaultEEPROM not functional.) I/O board

185 (All boot options failed.) 1. Set the startup sequence using the Configuration/Setup Utility program.

2. I/O board.

Error message/symptom FRU/action · Processor x

Page 161 of the IBM 8688 user manual — SAL/EFI messages
Seite 161 · Zum Vergrößern klicken
Seite 161
187 (I/O Card FaultVPD serial number not set.) I/O board
188 (I/O Card FaultBad EEPROM CRC#2.) I/O board

201 (Invalid memory configuration.) 1. Verify DIMM installation order.

2. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.
3. Replace failing DIMM.
4. Memory board.

210 (Invalid memory configuration) 1. Verify DIMM installation order.

2. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.
3. Replace failing DIMM.
4. Memory board.

211 (Memory board error) Memory board

212 (Memory board port 2 SMI parity error) Memory board

213 (Memory board port 1 SMI parity error) Memory board

214 (Error on memory board port 1.) 1. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.

2. Replace failing DIMM.
3. Memory board.

215 (Error on memory board port 2.) 1. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.

2. Replace failing DIMM.
3. Memory board.

216 (Memory board error.) Memory board

220 (DIMM in slot n is not DDR and ECC) Replace with DDR ECC DIMM.

221 (DIMM in slot n has an unsupported number of rows.)

Replace with correct DIMM.

222 (DIMM in slot n is an unsupported size.) Replace with correct DIMM.

223 (DIMMs in slots m and n are not a valid pair.) Ensure DIMMs in slots m and n are identical.

224 (DIMM capacity exceeded in port n, maximum 5 pairs total when using 2 GB DIMMs.)

Review and populate DIMMs according to installation rules.

229 (Processor boardExternal cache error, cache disabled.)

230 (CPU board cache controller error) Processor board

233 (CPU board cache controller Register error) Processor board

236 (CPU board cache controller request error handler) Processor board

237 (CPU board cache controller pending queue error) Processor board

238 (CPU board cache controller L4 error) Processor board

239 (CPU board cache controller coherence directory) Processor board

Chapter 6. Symptom-to-FRU index 151

Error message/symptom FRU/action · Processor board

Page 162 of the IBM 8688 user manual — SAL/EFI messages
Seite 162 · Zum Vergrößern klicken
Seite 162

240 (CPU board cache controller QuadT bus error) 1. Memory board

2. Processor board
3. Midplane board

241 (CPU board cache controller error) Processor board

245 (No configurable memory detected) 1. Verify DIMM installation order.

2. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.
3. Replace failing DIMMs.
4. Memory board.

247 (Error port n after WIAP SMI) Memory board

248 (Memory board RIAP not complete on port n) Memory board

249 (Memory board RIAP failed on port n) Memory board

265 (Memory board SMI initialization error on port n) Memory board

266 (Service processor machine check reported, disabled DIMM x and DIMM y.)

1. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.
2. Replace failing DIMMs.
3. Memory board.

267 (Service processor machine check reported, disabled cache)

268 (Uncorrectable error isolated to DIMMs x and y.) 1. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.

2. Replace failing DIMMs.
3. Memory board.

289 (Memory error detected, DIMM x disabled.) 1. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.

2. Replace DIMM x .
3. Enable the DIMM using the Configuration/Setup Utility program.
4. Memory board.

291 (Protexion: error DIMM x and y) 1. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.

2. Replace failing DIMM.
3. Memory board.

292 (Protexion: error DIMM x) 1. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.

2. Replace failing DIMM.
3. Memory board.
1162 (I/O boardSerial: port configuration error.) I/O board
1200 (Node 0/CPU slot xCPUID y : Machine check exception.)
1. Microprocessor x
2. Processor board

Error message/symptom FRU/action · Processor board

Page 163 of the IBM 8688 user manual — SAL/EFI messages
Seite 163 · Zum Vergrößern klicken
Seite 163
1205 (Node 0/CPU slot xCPUID y: Manually initiated crash.)
1. Microprocessor x
2. Processor board

1331 (I2C failure) 1. I/O board

2. Memory board
3. Midplane board
4. PCI-X board

1332 (I/O board I2C failure) I/O board

1333 (Memory board I2C failure) Memory board

1334 (Midplane board I2C failure) Midplane board

1335 (PCI board I2C failure) PCI-X board

1336 (I/O board error, DMC did not respond) I/O board

1337 (DMC errorfailed to enable PCI board integrated PC/PCI-X bridge)
1. PCI-X board
2. I/O board

1401 (Failed to enable unrecoverable error handling) I/O board

1610 (SP error xattempting L4 initialization.) Remote Supervisor Adapter
1611 ((SP error xvalidating L4 initialization.) Remote Supervisor Adapter

1612 (SP error completing L4 initialization. Remote Supervisor Adapter

1613 (SP error xenabling PCI board integrated PCI/PCI-X bridge)
1. PCI-X board
2. Remote Supervisor Adapter

1620 (Current SP main application version n required) 1. Update service processor firmware.

2. Remote Supervisor Adapter.
3. I/O board.

1621 (Current SP Boot ROM version x is outdated, x is required)

1. Update service processor firmware.
2. Remote Supervisor Adapter.
3. I/O board.

1622 (Current SP remote control version x is downlevel, version y required)

1. Update service processor firmware.
2. Remote Supervisor Adapter.
3. I/O board.

1623 (Current integrated system management processor version n is outdated, version n is required)

1. Update service processor firmware.
2. Remote Supervisor Adapter.
3. I/O board.

1801 (Slot x: ROM space not available) Reconfigure PCI/PCI-X adapters.

1802 (Slot x: I/O not available) Reconfigure PCI/PCI-X adapters.

1803 (Slot x: MMIO not available.) Reconfigure PCI/PCI-X adapters.

1804 (Slot x: MMIO below 1 MB not available) Reconfigure PCI/PCI-X adapters.

1805 (Slot xROM failed checksum) PCI/PCI-X adapter in slot x
1806 (Slot xFailed BIST) PCI/PCI-X adapter in slot x
1807 (Slot xInvalid header type) PCI/PCI-X adapter in slot x
1808 (Slot xBridge above device failed) 1. PCI-X board
2. I/O board

1809 (Planar device missing) I/O board

Chapter 6. Symptom-to-FRU index 153

Error message/symptom FRU/action

Page 164 of the IBM 8688 user manual — Service processor messages
Seite 164 · Zum Vergrößern klicken
Seite 164

1810 (Slot x: Unknown PCI error) 1. Reconfigure PCI/PCI-X adapters.

2. PCI adapter.
3. PCI-X board.
1820 (Node 0/PCI slot xMaster Data Parity Error.) 1. PCI/PCI-X adapter
2. PCI-X board
1821 (Node 0/PCI slot xDetected Parity Error.) 1. PCI/PCI-X adapter
2. PCI-X board
1822 (Node 0/PCI slot xSignaled System Error.) 1. PCI/PCI-X adapter
2. PCI-X board
1823 (I-node 0/PCI slot xReceived Master Abort.) 1. PCI/PCI-X adapter
2. PCI-X board
1824 (Node 0/PCI slot xReceived Target Abort.) 1. PCI/PCI-X adapter
2. PCI-X board
1825 (Node 0/PCI slot xSignaled Target Abort.) 1. PCI/PCI-X adapter
2. PCI-X board
1826 (Node 0/PCI slot xPCI Host Bridge detected an error.)
1. PCI/PCI-X adapter
2. PCI-X board

1962 (Start of [OS] failed.) Verify operating system installation/startup media.

Service processor messages

An example of a typical service processor message is as follows:

- Log Entry #: 2 Logging Source: ServProc Log Type: E, I, or W Date: 06/17/2003 Time: 6:17:3 Recoverable Error handling example message -

This message indicates simply that the machine was turned on at the recorded time. The possible service processor error messages are listed in the following table.

replacing the component.

Error message/symptom FRU/action

Page 165 of the IBM 8688 user manual — Service processor messages
Seite 165 · Zum Vergrößern klicken
Seite 165

Service Processor message FRU/action

12V A Bus Fault 1. Memory board VRM

2. Power backplane
3. Power cables
4. Memory board
5. Midplane board

12V B Bus Fault 1. Microprocessor 3 power module

2. Microprocessor 3 power module cable
3. Processor-board assembly
4. Power backplane
5. Power cables
6. Midplane board

12V C Bus Fault 1. Microprocessor 2 power module

2. Microprocessor 2 power module cable
3. Processor-board assembly
4. Power backplane
5. Power cables
6. Midplane board

12V D Bus Fault 1. Microprocessor 4 power module

2. Microprocessor 4 power module cable
3. Processor-board assembly
4. Power backplane
5. Power cables
6. Midplane board

12V E Bus Fault 1. Fans

2. Midplane-board VRM
3. Processor board
4. Power backplane
5. Power cables
6. Midplane board
7. I/O board

12V F Bus Fault 1. Microprocessor 1 power module

2. Microprocessor 1 power module cable
3. Processor-board assembly
4. Power backplane
5. Power cables
6. Midplane board

12V G Bus Fault 1. PCI-X board

2. Power backplane
3. Power cables
4. Midplane board

Chapter 6. Symptom-to-FRU index 155

Page 166 of the IBM 8688 user manual — Service processor messages
Seite 166 · Zum Vergrößern klicken
Seite 166

Service Processor message FRU/action

12V H Bus Fault 1. Disk drives

2. Disk drive backplane
3. I/O board
4. Power backplane
5. Power cables
6. Midplane board

5V Fault 1. Remove PCI adapters, and see if the problem remains.

2. I/O board.
CableControl Panel Not Present Cable to Light Path panel
CableSCSI I2C cable not detected Cable to SCSI backplane
CableService Processor Not Present 1. Remote Supervisor Adapter
2. I/O board

Center Card Power Fault 1. Midplane VRM

2. Midplane board

CPU 1-4 Over Temperature 1. Check airflow blockage

2. Check fans
3. Microprocessor 1-4

Failure reading I2C device. Check devices on bus x.

1. Restart the server
2. I/O board

Fan 1-4 Failure 1. Check fan connection.

2. Fan.

Fan 1-4 not detected 1. Check fan connection.

2. Fan.

Fan 1-4 Outside Recommended Speed 1. Check fan connection.

2. Fan.

Invalid Fan configuration 1. Check fan connections.

2. Fans.

Hard Drive 1-2 Fault Run diagnostics.

Hard Drive 1-2 removal detected 1. Hard disk drive

2. Run diagnostics

Integrated Systems Management Processor encountered failures upon starting

1. Remove ac power for 20 seconds, reconnect and reboot, and run diagnostics.
2. I/O board.

Invalid CPU configuration Ensure microprocessor 1 is properly installed.

CPU Card Machine Check TOR_MCK 1. Run diagnostics.

2. Microprocessors.
3. Processor board.
4. Memory board.
5. I/O board.
6. Midplane board.
Page 167 of the IBM 8688 user manual — Service processor messages
Seite 167 · Zum Vergrößern klicken
Seite 167

Service Processor message FRU/action

Memory Card Machine Check CYC_MCK2 1. Run diagnostics.

2. Memory board.
3. Processor board.
4. I/O board.
5. PCI-X board.
6. Midplane board.

Native I/O Card Machine Check 1. Remove adapters in PCI-X slots 1 and 2, and run diagnostics.

2. I/O board.
3. Memory board.
4. Midplane board.

PCI Card Machine Check 1. Remove PCI adapters, and run diagnostics.

2. PCI-X board.
3. Memory board.
4. Midplane board.

PCI Power Good Fault 1. Remove PCI adapters and run diagnostics.

2. PCI-X board.

Power supply 1-2 current exceeded max spec value

1. Check both power supplies are installed and connected to ac.
2. Power supply 1-2.
3. Power backplane.

Power Supply 1-2 Current Fault 1. Check/replace power supply 1-2.

2. Power backplane.

Power Supply 1-2 Overcurrent Fault 1. Check/replace power supply 1-2.

2. Power backplane.

Power Supply 1-2 12v Overvoltage Fault 1. Check/replace power supply 1-2.

2. Power backplane.

Power Supply 1-2 12v Undervoltage Fault 1. Check/replace power supply 1-2.

2. Power backplane.

Power Supply 1-2 5v Undervoltage Fault 1. Check/replace power supply 1-2.

2. Power backplane.

Power Supply 1-2 ac Power Removed, Early Power Off Warning

Check ac power inputs.

Power Supply 1-2 dc Good Fault Check/replace power supply 1-2.

Power Supply 1-2 Fan Fault Check/replace power supply 1-2.

Power Supply 1-2 Removed Check/replace power supply 1-2.

Power Supply 1-2 Temperature Fault 1. Check for airflow obstructions.

2. Check/replace power supply 1-2.

System shutoff due to CPU 1-4 over temperature

1. Check for airflow obstructions.
2. Check fans.
3. Microprocessor 1-4.

Chapter 6. Symptom-to-FRU index 157

Page 168 of the IBM 8688 user manual — Service processor messages
Seite 168 · Zum Vergrößern klicken
Seite 168

Service Processor message FRU/action

System shutoff due to high ambient temperature 1. Check room temperature.

2. Check for airflow obstructions.
3. Check fans.
4. Light Path assembly.

Xcel4 Accelerator Cache Error Detected. Processor board

Uncorrectable memory error on DIMMs x, y 1. Reseat DIMMs, re-enable DIMMs, if necessary, using the Configuration/Setup Utility program, and run diagnostics.

2. DIMMs x, y.

VRM 1-4 Fault 1. Check microprocessor 1-4 power module cable.

2. Microprocessor 1-4 power module.

+2.5v VRM power fault 1. Memory board 2.5v VRM

2. Memory board

+1.8v VRM power fault 1. Memory board 1.8v VRM

2. Memory board

1.8v Fault 1. Processor-board 1.8v VRM

2. Processor-board assembly

1.25v Fault Processor board

Memory +1.8v Power fault 1. Memory board 1.8v VRM

2. Memory board

Memory +1.25v Power fault 1. Memory board 1.25v VRM

2. Memory board

Primary I/O Power fault I/O board

Environmental Monitor Flash Update Failed. 1. Retry Flash Update.

2. I/O board.

Environmental Monitor ROM error. 1. Remove ac power for 20 seconds, reconnect, and run diagnostics.

2. Flash update system-management firmware.
3. I/O board.

Environmental Monitor RAM error 1. Remove ac power for 20 seconds, reconnect, and run diagnostics.

2. I/O board.

Environmental Monitor firmware needs updating. No environmental information currently available.

Flash update system-management firmware.

The service processor also generates a large number of information, error, and warning messages.

If an RXE-100 unit is attached, the service processor might generate further messages specific to this unit. For information about these error messages, see “RXE port error codes” on page 173.

Page 169 of the IBM 8688 user manual — System-error codes
Seite 169 · Zum Vergrößern klicken
Seite 169

Diagnostic error codes

For information on running the diagnostic programs, see “Starting the AMIDiag program” on page 38.

System-error codes

3000h (Register Bank Switch Failed .)

1. Reseat all microprocessors and power modules.
2. Individually replace microprocessors and power modules.
3. Processor board.

3001h (Register Read/Write Failed .)

1. Reseat all microprocessors and power modules.
2. Individually replace microprocessors and power modules.
3. Processor board.

3002h (CPU Basic Instruction Operation Failed.)

1. Reseat all microprocessors and power modules.
2. Individually replace microprocessors and power modules.
3. Processor board.

3003h (CPU Parallel Data Manipulation Failed.)

1. Reseat all microprocessors and power modules.
2. Individually replace microprocessors and power modules.
3. Processor board.

3005h (FPU Arithmetic Error.) 1. Reseat all microprocessors and power modules.

2. Individually replace microprocessors and power modules.
3. Processor board.

3006h (FPU Comparison Error.) 1. Reseat all processors and power modules.

2. Individually replace microprocessors and power modules.
3. Processor board.

3007h (FPU Load/Store Error.) 1. Reseat all microprocessors and power modules.

2. Individually replace microprocessors and power modules.
3. Processor board.

3008h (FPU Conversion Error.) 1. Reseat all microprocessors and power modules.

2. Individually replace microprocessors and power modules.
3. Processor board.

3010h (CPU Speed does not match expected value.)

1. Check that the expected value entered is correct.
2. Reseat all microprocessors and power modules.
3. Individually replace microprocessors and power modules.
4. Processor board.

3100h (Read/Write test on DMA controller 1 failed.)

3101h (Read/Write test on DMA controller 2 failed.)

3102h (Read/Write test on page registers failed.)

3140h (Battery backup unit that powers CMOS RAM has no power. )

Battery or CMOS unit

Chapter 6. Symptom-to-FRU index 159

Show 4 more labels / short text on this page
Error Code/Symptom FRU/action · I/O board · I/O board · I/O board
Page 170 of the IBM 8688 user manual — Diagnostic error codes
Seite 170 · Zum Vergrößern klicken
Seite 170

3141h (Configuration mismatch in CMOS RAM.)

1. Run the Configuration/Setup Utility program.
2. Battery or CMOS unit.

3142h (CMOS RAM memory size.)

1. Run the Configuration/Setup Utility program.
2. Battery or CMOS unit.

3143h (CMOS RAM time is invalid. )

1. Run Configuration/Setup Utility program.
2. Battery or CMOS unit.

3144h (Bad CMOS RAM checksum detected.)

1. Run Configuration/Setup Utility program.
2. Battery or CMOS unit.

3145h (Periodic time update cycle not occurring.)

3146h (CMOS RAM fails to hold data. )

00A0h (PCI Device Enumeration Failed .)

1. Reseat all PCI devices.
2. Remove all PCI devices from PCI-X board, and re-run the PCI Test.
3. If step 2 is successful, replace PCI devices on the PCI-X board one at a time until faulty PCI devices are identified, and replace faulty PCI devices.
4. PCI-X board.

00A1h (PCI Device Access Failed.)

1. Reseat all PCI devices.
2. Remove all PCI devices from PCI-X board, and re-run the PCI Test.
3. If step 2 is successful, replace PCI devices on the PCI-X board one at a time until faulty PCI devices are identified, and replace faulty PCI devices.
4. PCI-X board.

00A2h (PCI Configuration Space could not be verified.)

1. Reseat all PCI devices.
2. PCI-X board.

1000h (MP table failed or Load MP driver failed.)

1. Replace SAL/EFI.
2. I/O board.

1009h (Cache coherency test failed. )

1. Reseat all microprocessors and power modules.
2. Individually replace processors and power modules.
3. Processor board.

100Ah (Memory consistency test failed.)

1. Reseat all processors and power modules.
2. Individually replace microprocessors and power modules.
3. Processor board.

100Bh (I/O access test failed on processor X at port XXXXh.)

1. Reseat all microprocessors and power modules.
2. Individually replace microprocessors and power modules.
3. Processor board.

100Eh (CPU speed error.) 1. Check that the expected value entered is correct.

2. Reseat all microprocessors and power modules.
3. Individually replace microprocessors and power modules.
4. Processor board.

1020h (CPU functionality test failed. )

1. Reseat all microprocessors and power modules.
2. Individually replace microprocessors and power modules.
3. Processor board.

Error Code/Symptom FRU/action · I/O board · I/O board

Page 171 of the IBM 8688 user manual — IDE CD test error codes
Seite 171 · Zum Vergrößern klicken
Seite 171

1021h (FPU functionality test failed. )

1. Reseat all microprocessors and power modules.
2. Individually replace microprocessors and power modules.
3. Processor board.

1024h (MP test time out.) 1. Reseat all microprocessors and power modules.

2. Individually replace microprocessors and power modules.
3. Processor board.

IDE CD test error codes

0A01h (Eject fails on drive x.) 1. Manually eject media.

2. Retry tray function.
3. Check drive cables and connections.
4. Drive.
5. I/O board.

0A02h (Close failed on drive x.) 1. Manually close drive.

2. Retry tray function.
3. Check drive cables and connections.
4. Drive.
5. I/O board.

0A03h (Sequential data test failed, Drive x, Sector Y.)

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0A04h (Sequential data test failed, No data CD in Drive x.)

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0A05h (Random data test failed, Drive x, Sector Y.)

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0A06h (Random data test failed, No data CD in Drive x.)

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

Chapter 6. Symptom-to-FRU index 161

Error Code/Symptom FRU/action · Error Code/Explanation FRU/Action

Page 172 of the IBM 8688 user manual — ATAPI removables test error codes
Seite 172 · Zum Vergrößern klicken
Seite 172

0A07h (Sequential Play test failed, Drive x, Sector y. )

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0A08h (Sequential Play test failed, no Audio CD in Drive x.)

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0A09h (Random Play test failed, Drive x, Sector y. )

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0A10h (Random Play test failed, no Audio CD in Drive x.)

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0A11h (No Audio tracks in the multisession CD in the Drive x.)

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0A12h (Number of Audio tracks inadequate for the test .)

1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

ATAPI removables test error codes

0F01h (No ATAPI Removable drives present.) 1. Check drive cables and connections.

2. Connect drive to other IDE channel.
3. Drive.
4. I/O board.

0F02h (Write failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

Error Code/Explanation FRU/Action · Error Code/Explanation FRU/Action

Page 173 of the IBM 8688 user manual — ATAPI removables test error codes
Seite 173 · Zum Vergrößern klicken
Seite 173

0F03h (Read failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0F04h (Seek operation failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0F05h (Eject fails on drive x.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0F06h (Sequential Read Verify failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0F07h (Random Read Operation failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0F08h (Random Read Verify failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

0F09h (Random Seek Operation failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

Chapter 6. Symptom-to-FRU index 163

Error Code/Explanation FRU/Action

Page 174 of the IBM 8688 user manual — SCSI test error codes
Seite 174 · Zum Vergrößern klicken
Seite 174

IDE DVD-ROM drive test error codes

1900h (Critical/Command Error.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

1901h (DVD Seek Test failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

1902h (DVD Read Test failed.) 1. Replace media.

2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.

SCSI test error codes

0500h (SCSI device not ready.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0502h (SCSI device read error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0506h (SCSI disk self test failed.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0507h (SCSI disk buffer error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0508h (SCSI disk random read error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. System I/O Board or SCSI add-on controller.

Error Code/Explanation FRU/Action · Code/Explanation FRU/Action

Page 175 of the IBM 8688 user manual — IDE DVD-ROM drive test error codes
Seite 175 · Zum Vergrößern klicken
Seite 175

0509h (SCSI disk random write error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

050Ch (Error in disk partition table .) 1. Confirm that drive is formatted and configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

050Dh (Boot sector error. The boot partition has an incorrect definition.)

1. Confirm that drive is formatted and configured .
2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

050Eh (Media error. The media description for the partition is bad. The unit is not properly formatted.)

1. Confirm that drive is formatted and configured.
2. Check drive cables and connections.
3. Drive.
4. I/O Board or SCSI add-on controller.

050Fh (The sector number information in the partition table is wrong. The unit is not properly OS formatted.)

1. Confirm that drive is formatted and configured.
2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0510h (No Tape in the drive.) 1. Check if a tape is in drive.

2. Confirm that drive is configured.
3. Check drive cables and connections.
4. Drive.
5. I/O board or SCSI add-on controller.

0511h (Positioning failed on tape drive.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0512h (Tape read error.) 1. Check if write test has been run.

2. Confirm that drive is configured.
3. Check drive cables and connections.
4. Drive.
5. I/O board or SCSI add-on controller.

0515h (Tape Self-test error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0516h (Tape buffer error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

Chapter 6. Symptom-to-FRU index 165

Code/Explanation FRU/Action

Page 176 of the IBM 8688 user manual — IDE DVD-ROM drive test error codes
Seite 176 · Zum Vergrößern klicken
Seite 176

0520h (No CD in the drive.) 1. Check if a CD is in drive.

2. Confirm that drive is configured.
3. Check drive cables and connections.
4. Drive.
5. I/O board or SCSI add-on controller.

0521h (CD-ROM read error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0523h (CD-ROM play error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0524h (CD Self-test error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0525h (CD Open error.) 1. Manually eject media and close drive.

2. Retry tray function.
3. Confirm that drive is configured.
4. Check drive cables and connections.
5. Drive.
6. I/O board or SCSI add-on controller.

0526h (CD Close error.) 1. Manually eject media and close drive.

2. Retry tray function.
3. Confirm that drive is configured.
4. Check drive cables and connections.
5. Drive.
6. I/O board or SCSI add-on controller.

0527h (CD Buffer error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0528h (Pattern compare failed. Check pattern did not match.)

1. Check if AMIDiag CD is present in drive.
2. Confirm that drive is configured.
3. Check drive cables and connections.
4. Drive.
5. I/O board or SCSI add-on controller.

0529h (CD-ROM random read error.) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

Code/Explanation FRU/Action

Page 177 of the IBM 8688 user manual — USB test error codes
Seite 177 · Zum Vergrößern klicken
Seite 177

0550h (Read timeout .) 1. Confirm that drive is configured.

2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

0560h (File not found.) 1. Check if AMIDiag CD is present in drive.

2. Confirm that drive is configured.
3. Check drive cables and connections.
4. Drive.
5. I/O board or SCSI add-on controller.

0580h (Cannot allocate memory.) Restart the server and retry.

0590h (Command not supported. Unable to run the test on the device.)

1. Confirm that drive is configured.
2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.

Video test error codes

0900h (Vertical Synchronization Test failed.) I/O board

0901h (Horizontal Synchronization Test failed.) I/O board

0902h (Graphics controller test failed.) I/O board

0903h (Attribute controller test failed.) I/O board

0904h (DAC register test failed.) I/O board

0905h (Video adapter memory R/W test failed .) I/O board

2100h (Video adapter attribute test failed. ) 1. Video monitor

2. I/O board

2102h (Video adapter color test failed.) 1. Video monitor

2. I/O board

2110h - 2120h (Param1 x Param2 mode test failed.) 1. Video monitor

2. I/O board

USB test error codes

If any of the following USB errors occur on devices not directly attached to a USB port on the xSeries 450 (for example, a USB mouse attached to a USB keyboard with an internal USB hub), connect the suspect device directly to the xSeries 450 and re-run the failing test to isolate whether the failure is with an intermediate device, the device being tested, or the USB subsystem of the xSeries 450. In cases where the direct attachment passes, replace the intermediate devices and re-test in the original configuration before replacing the device being tested or the I/O board.

Chapter 6. Symptom-to-FRU index 167

Code/Explanation FRU/Action · Code/Explanation FRU/Action

Page 178 of the IBM 8688 user manual — Video test error codes
Seite 178 · Zum Vergrößern klicken
Seite 178

0B00h (USB mouse set protocol failed.) 1. Check USB mouse connection.

2. USB mouse.
3. I/O board.

0B01h (USB mouse remove and attach tests failed.)

1. Check USB mouse connection .
2. USB mouse.
3. I/O board.

0B02h (USB mouse not present.) 1. Check USB mouse connection.

2. USB mouse.
3. I/O board.

0B30h (USB keyboard control test failed.) 1. Check USB keyboard connection.

2. USB keyboard.
3. I/O board.

0B40h (USB keyboard LED test failed.) 1. Check USB keyboard connection.

2. USB keyboard.
3. I/O board.

0B50h (USB keyboard remove and attach test failed.)

1. Check USB keyboard connection.
2. USB keyboard.
3. I/O board.

0B60h (USB keyboard not present.) 1. Check USB keyboard connection.

2. USB keyboard.
3. I/O board.

0B70h (USB Hub communication test failed.) 1. Check USB hub connection.

2. USB hub.
3. I/O board.

1302h (UHCI Register Test failed.) I/O board

1303h (UHCI Status Test failed.) I/O board

1304h (UHCI Interrupt Test failed.) I/O board

1305h (UHCI Frame Test failed.) I/O board

1306h (UHCI Transfer Descriptor Test failed.) I/O board

1312h (OHCI Register Test failed.) I/O board

1313h (OHCI Status Test failed.) I/O board

1314h (OHCI Interrupt Test failed.) I/O board

1315h (OHCI Frame Test failed.) I/O board

1316h (OHCI Transfer Descriptor Test failed.)

Code/Explanation FRU/Action · I/O board

Page 179 of the IBM 8688 user manual — Serial port test error codes
Seite 179 · Zum Vergrößern klicken
Seite 179

Serial port test error codes

0601h (Data written to port XXXXh was yyyyh. Data read back from the port was zzzzh.)

1. Check connection of loopback if used during test.
2. I/O board.

0602h (Interrupt identification register test failed .)

0603h (Data written to port XXXXh was yyyyh. Data read back from the port was zzzzh .)

1. Check connection of loopback if used during test.
2. I/O board.

0604h (Line status register test failed at port XXXXh .)

0605h (Interrupt activation test failed at port XXXXh.)

0606h (Data transfer test failed at port XXXXh 1.)

1. Check connection of loopback if used during test.
2. I/O board.

0607h (Loop back test failed at port XXXXh .)

1. Check connection of loopback if used during test.
2. I/O board.

0608h (FIFO register test failed at port XXXXh.)

0609h (FIFO trigger level test failed at port XXXXh. )

0610h (FIFO character timeout indication test failed at port XXXXh.)

0611h (FIFO data transfer test failed at port XXXXh. )

0612h (Baud rate speed test failed at port XXXXh. )

Chapter 6. Symptom-to-FRU index 169

Show 9 more labels / short text on this page
Code/explanation FRU/action · I/O board · I/O board · I/O board · I/O board · I/O board · I/O board · I/O board · I/O board
Page 180 of the IBM 8688 user manual — Advanced System Management error codes
Seite 180 · Zum Vergrößern klicken
Seite 180

Advanced System Management error codes

9100-xxx-xxx-xxx (SAL/EFI failed to communicate with ASM.)

1. Run ASM Restart Test to restart ASM.
2. Rerun diagnostic test.
3. Correct other error conditions, including other failed system management tests and items logged in Remote Supervisor adapter system-error log, and retry.
4. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.
5. Remote Supervisor Adapter.
6. I/O board.

9101-000-000-000 (DMC Self Test failed to complete.) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.

2. Update the ISMP on the xSeries 450 node and RXE with the latest firmware level.
3. RXE backplane if test on RXE unit, I/O board if test on xSeries 450 node.

9102-000-000-000 (DMC Self Test failed update.) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.

2. Update the ISMP on the xSeries 450 node and RXE with the latest firmware level.
3. RXE backplane if test on RXE unit, I/O board if test on xSeries 450 node.

9103-000-000-000 (DMC Self Test failed ROM.) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.

2. Update the ISMP on the xSeries 450 node and RXE with the latest firmware level.
3. RXE backplane if test on RXE unit, I/O board if test on xSeries 450 node.

9104-000-000-000 (DMC Self Test failed RAM.) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.

2. Update the ISMP on the xSeries 450 node and RXE with the latest firmware level.
3. RXE backplane if test on RXE unit, I/O board if test on xSeries 450 node.

9105-004-000-000 (ISMP indicates I2C errors on bus A0.) 1. I/O board

2. Midplane board

9105-004-001-000 (ISMP indicates I2C errors on bus A1.) 1. VRMs and microprocessors installed in midplane board

2. Midplane board

9105-004-002-000 (ISMP indicates I2C errors on bus A2.) 1. Memory board

2. Midplane board

Code/explanation FRU/action

Page 181 of the IBM 8688 user manual — Advanced System Management error codes
Seite 181 · Zum Vergrößern klicken
Seite 181

9105-004-003-000 (ISMP indicates I2C errors on bus A3.) 1. I/O board

2. Remote Supervisor Adapter
3. Midplane board

9105-004-004-000 (ISMP indicates I2C errors on bus A4.) 1. PCI devices on PCI-X card

2. PCI-X card
3. Midplane board

9105-004-005-000 (ISMP indicates I2C errors on bus A5.) 1. Power supply

2. Top power board
3. Midplane board

9105-004-006-000 (ISMP indicates I2C errors on bus A6.) Midplane board

9105-004-007-000 (ISMP indicates I2C errors on bus A7.) 1. Hard disk drive backplane

2. SCSI I2C cable
3. Midplane board

9105-004-008-000 (ISMP indicates I2C errors on bus A8.) 1. Light Path card

2. Light Path cable
3. Midplane board

9105-004-009-000 (ISMP indicates I2C errors on bus A2M0.)

1. Memory DIMMs 1-7
2. Memory board

9105-004-00a-000 (ISMP indicates I2C errors on bus A2M1.)

1. Memory DIMMs 8-14
2. Memory board

9105-004-00b-000 (ISMP indicates I2C errors on bus A2M2.)

1. Memory DIMMs 15-21
2. Memory board

9105-004-00c-000 (ISMP indicates I2C errors on bus A2M3.)

1. Memory DIMMs 22-28
2. Memory board

9105-004-00d-000 (ISMP indicates errors on bus A4J0.) PCI-X board

9105-004-00e-000 (ISMP indicates errors on bus A4J1.) PCI-X board

9105-004-00f-000 (ISMP indicates errors on bus A4J2.) PCI-X board

9105-004-010-000 (ISMP indicates I2C errors on bus A4J3.)

9105-004-011-000 (ISMP indicates I2C errors on bus A4J1 PCI slot 1.)

1. PCI adapter in PCI-X slot 1
2. PCI-X board

9105-004-012-000 (ISMP indicates I2C errors on bus A4J1 PCI slot 2.)

1. PCI adapter in PCI-X slot 2
2. PCI-X board

9105-004-013-000 (ISMP indicates I2C errors on bus A4J1 PCI slot 3.)

1. PCI adapter in PCI-X slot 3
2. PCI-X board

9105-004-014-000 (ISMP indicates I2C errors on bus A4J1 PCI slot 4.)

1. PCI adapter in PCI-X slot 4
2. PCI-X board

9105-004-015-000 (ISMP indicates I2C errors on bus A4J1 PCI slot 5.)

1. PCI adapter in PCI-X slot 5
2. PCI-X board

9105-004-016-000 (ISMP indicates I2C errors on bus A4J1 PCI slot 6.)

1. PCI adapter in PCI-X slot 6
2. PCI-X board

Chapter 6. Symptom-to-FRU index 171

Code/explanation FRU/action · PCI-X board

Page 182 of the IBM 8688 user manual — Advanced System Management error codes
Seite 182 · Zum Vergrößern klicken
Seite 182

9105-001-000-000 or 9105-002-000-000 (ISMP indicates I2C errors on RXE bus X.)

See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.

9105-001-001-000 or 9105-002-001-000 (ISMP indicates I2C errors on RXE bus P.)

See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.

9105-001-002-000 (ISMP indicates I2C errors on RXE bus I_A.)

See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.

9105-002-003-000 (ISMP indicates I2C errors on RXE bus I_B.)

See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.

9105-001-004-000 (ISMP indicates I2C errors on RXE bus PCI_A)

See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.

9105-001-005-000 or 9105-002-005-000 (ISMP indicates I2C errors on RXE bus F.)

See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.

9105-002-006-000 (ISMP indicates I2C errors on RXE bus PCI_B)

See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.

9105-001-007-000 (ISMP indicates I2C errors on RXE bus PCI_A slot 1.)

PCI adapter in slot A1

9105-001-008-000 (ISMP indicates I2C errors on RXE bus PCI_A slot 2.)

PCI adapter in slot A2

9105-001-009-000 (ISMP indicates I2C errors on RXE bus PCI_A slot 3.)

PCI adapter in slot A3

9105-001-00a-000 (ISMP indicates I2C errors on RXE bus PCI_A slot 4.)

PCI adapter in slot A4

9105-001-00b-000 (ISMP indicates I2C errors on RXE bus PCI_A slot 5.)

PCI adapter in slot A5

9105-001-00c-000 (ISMP indicates I2C errors on RXE bus PCI_A slot 6.)

PCI adapter in slot A6

9105-002-00d-000 (ISMP indicates I2C errors on RXE bus PCI_B slot 1.)

PCI adapter in slot B1

9105-001-00e-000 (ISMP indicates I2C errors on RXE bus PCI_B slot 2.)

PCI adapter in slot B2

9105-001-00f-000 (ISMP indicates I2C errors on RXE bus PCI_B slot 3.)

PCI adapter in slot B3

9105-001-010-000 (ISMP indicates I2C errors on RXE bus PCI_B slot 4.)

PCI adapter in slot B4

9105-001-011-000 (ISMP indicates I2C errors on RXE bus PCI_B slot 5.)

PCI adapter in slot B5

9105-001-012-000 (ISMP indicates I2C errors on RXE bus PCI_B slot 6.)

PCI adapter in slot B6

Code/explanation FRU/action

Page 183 of the IBM 8688 user manual — RXE port error codes
Seite 183 · Zum Vergrößern klicken
Seite 183

9106-xxx-xxx-xxx (ISMP indicates untested I2C bus.) 1. Run diagnostic test again.

2. Correct other error conditions, including other system-management tests and items logged in Remote Supervisor Adapter system-error log, and retry.
3. Disconnect all server and option power cords, wait 30 seconds, reconnect, and retry.
4. Update the xSeries 450 node with the latest firmware level of diagnostics, ISMP, and ASM. Update RXE with latest ISMP firmware, and retry.
5. If a 9106 error occurs again, follow the FRU/action for error 9105 with respective parameter set.

9107-xxx-000-000 (System Management BIST indicates failed tests.)

1. Run Restart ASM Test and re-run ASM BIST Test.
2. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.
3. Remote Supervisor Adapter.

RXE port error codes

9204-091-094-011 (RXE Expansion Port A failure.)

1. RXE cable A
2. RXE expansion board to which cable is connected (Side A or Side B)
3. I/O board

9204-091-094-012 (RXE Expansion Port B failure.)

1. RXE cable B
2. RXE expansion board to which cable is connected (Side A or Side B)
3. Processor board
4. Midplane board

9204-091-094-015 (RXE100 Side A to Side B failure.)

1. Side A card in RXE100
2. Side B card in RXE100

9204-091-094-016 (RXE100 Side B to Side A failure.)

1. Side B card in RXE100
2. Side A card in RXE100

9216-091-094-nnn (Receive Error on any port.)

Restart the server. This usually means that an RXE cable has been attached after SAL/EFI has run.

9220-091-094-011 (Transmit error on Port A.)

1. RXE cable B
2. RXE expansion board to which cable is connected (Side A or Side B)
3. I/O board

9220-091-094-012 (Transmit error on Port B.)

1. RXE cable B
2. RXE expansion board to which cable is connected (Side A or Side B)
3. Processor board
4. Midplane board

9220-091-094-015 (RXE100 Side A to Side B failure.)

1. Side A card in RXE100
2. Side B card in RXE100

Chapter 6. Symptom-to-FRU index 173

Code/explanation FRU/action · Code/explanation FRU/action

Page 184 of the IBM 8688 user manual — Memory test error codes
Seite 184 · Zum Vergrößern klicken
Seite 184

9220-091-094-016 (RXE100 Side B to Side A failure.)

1. Side B card in RXE100
2. Side A card in RXE100

9228-091-094-011 (No incoming power on Port A.)

Missing cable on Port A

9228-091-094-012 (No incoming power on Port B.)

Missing cable on Port B

9228-091-094-014 (No incoming power on port.)

Missing cable on RXE100 Side A Port A

9228-091-094-017 (No incoming power on port.)

Missing cable on RXE100 Side B Port B

9232-091-094-011 (Driver disabled on Port A.)

Missing cable on Port A

9232-091-094-012 (Driver disabled on Port B.)

Missing cable on Port B

9232-091-094-014 (Driver disabled on port.)

Missing cable on RXE100 Side A Port A

9232-091-094-017 (Driver disabled on port.)

Missing cable on RXE100 Side B Port B

9236-091-094-011 (Port A is disabled.)

Missing cable on Port A

9236-091-094-012 (Port B is disabled.)

Missing cable on Port B

9236-091-094-014 (RXE100 Side A Port A is disabled.)

Missing cable on RXE100 Side A Port A

9236-091-094-017 (RXE100 Side B Port B is disabled.)

Missing cable on RXE100 Side B Port B

Memory test error codes

Table 10. Memory test error codes

9301-xxx-00-00 (Test AbortedMemory Hole Size Error.)
1. Restart the server, and run the test again.
2. If the symptom still exists, then update the SAL/EFI.
9302-xxx-00-00 (Test AbortedDIMM Configuration Error.)
1. Restart the server, and run the test again.
2. If the symptom still exists, then update the SAL/EFI.

9303-xxx-00-00 (EFI operating system error. Test Aborted: Buffer too small.)

1. Restart the server, and run the test again.
2. If the symptom still exists, reload the EFI operating system.

9304-xxx-00-00 (EFI operating system error. Test Aborted: Invalid Parameter.)

1. Restart the server, and run the test again.
2. If the symptom still exists, reload the EFI operating system.
9305-xxx-00-00 (Test AbortedMemory WRT not complete.)
1. Restart the server, and run the test again.
2. If the symptom still exists, replace the memory board.

9306-xxx-00-00 (Memory Diagnostic Program Error. Test Aborted: Invalid Bank Selected.)

1. Restart the server, and run the test again.
2. If the symptom still exists, reflash the diagnostic code.

Code/explanation FRU/action · Error code/symptom FRU/action

Page 185 of the IBM 8688 user manual — LED error codes
Seite 185 · Zum Vergrößern klicken
Seite 185

Table 10. Memory test error codes (continued)

9307-xxx-00-00 (Test AbortedChoppiest Internal Error.)
1. Restart the server, and run the test again.
2. If the symptom still exists, reflash the diagnostic code.

9308-xxx-00-00 (Diagnostic Program Error. Test Aborted: No DIMMs installed.)

1. Restart the server, and run the test again.
2. If the symptom still exists, reflash the diagnostic code.
9309-xxx-00-00 (Test AbortedFast Scrub Error.)
1. Reload the system, and run the test again.
2. If the symptom still exists, replace the memory board.

9310-xxx-nn-nn (Test Failed: ECC errors.) nn= the DIMM connector designation, 1-28.

1. Restart the server, and run the test again.
2. If the symptom still exists, replace the DIMMs.

LED error codes

Table 11. LED error codes

9001-180-xxx-xxx (Failed Front LED panel test.)

1. Light Path Diagnostics card
2. Power/reset card assembly
3. Midplane board
4. I/O board

9002-180-xxx-xxx (Failed Memory Board LED test.)

1. Memory board
2. Midplane board

9003-180-xxx-xxx (Failed Active PCI LED test.)

9004-180-xxx-xxx (Failed Diagnostics LED test.)

1. Light Path Diagnostics card
2. Midplane board

9005-180-xxx-xxx (Failed Fan LED test.)

1. Fan
2. I/O board

9006-180-xxx-xxx (Failed Centerplane LED test.)

9007-180-xxx-xxx (Failed I/O board LED test.)

9008-180-xxx-xxx (Failed SCSI Backplane LED test.)

1. SCSI backplane cable
2. SCSI backplane
3. Midplane board

Table 12. LED error codes for the RXE100 port

9021-180-xxx-xxx (Failed RXE Operator panel LED test)

1. RXE Operator panel cable
2. RXE Operator panel
3. RXE backplane

9022-180-xxx-xxx (Failed RXE PCIXBackplane Side A LED test)

1. RXE PCI-X backplane (Side A)
2. RXE backplane

Chapter 6. Symptom-to-FRU index 175

Show 6 more labels / short text on this page
Error code/symptom FRU/action · Error code/symptom FRU/action · PCI-X board · Midplane board · I/O board · Error code/symptom FRU/action
Page 186 of the IBM 8688 user manual — Error symptoms
Seite 186 · Zum Vergrößern klicken
Seite 186

Table 12. LED error codes for the RXE100 port (continued)

9023-180-xxx-xxx (Failed RXE PCIX Backplane Side B LED test)

1. RXE PCI-X backplane (Side B)
2. RXE backplane

9024-180-xxx-xxx (Failed RXE Fans LED test)

1. RXE fans(s)
2. RXE backplane

9025-180-xxx-xxx (Failed RXE backplane LED test)

Error symptoms

CD-ROM drive problems Make sure that:

1. The IDE channels are enabled in the Configuration/Setup Utility program.

CD-ROM drive is not recognized.

2. All cables and jumpers are installed correctly.
3. The correct device driver is installed for the CD-ROM drive.

Make sure that: 1. The cables for all external SCSI options are connected correctly. 2. The last option in each SCSI chain, or the end of the SCSI cable, is terminated correctly. 3. Any external SCSI option is turned on. You must turn on an external SCSI option before turning on the server.

The SCSI expansion enclosure used to work but does not work now.

For more information, see your SCSI and expansion enclosure documentation.

Hard disk drive problems 1. Remove the first drive not recognized, and try the hard disk diagnostic test again.

Not all drives are recognized by the hard disk diagnostic test (Fixed Disk test).

2. If the remaining drives are recognized, replace the drive you removed with a new one.

System stops responding during hard disk diagnostic.

1. Remove the hard disk drive being tested when the server stopped responding and try the diagnostic again.
2. If the hard disk diagnostic runs successfully, replace the drive you removed with a new one.

SCSI drives not recognized during POST (loose connection)

1. Reseat SCSI cable between I/O and T-docking boards.
2. Reseat hard disk drive.

CD-ROM drive not recognized by SAL/EFI (loose connection)

1. Reseat IDE cable and power cable.
2. Ensure that SAL/EFI setup has these devices enabled.

Not all drives are recognized by fixed disk diagnostic.

1. Remove first drive that does not show up and rerun diagnostic. If remaining drives show up, replace the one that was removed.
2. If remaining drives do not show up, remove successive drives one at a time and rerun diagnostic.

System hangs during fixed disk diagnostic.

Remove hard drive being tested at the time of the hang and rerun the diagnostic. If successful, replace drive that was removed.

Show 5 more labels / short text on this page
Error code/symptom FRU/action · RXE backplane · Symptom Suggested action · Expansion enclosure · problems
Page 187 of the IBM 8688 user manual — Error symptoms
Seite 187 · Zum Vergrößern klicken
Seite 187

Intermittent problems Make sure that: 1. All cables and cords are connected securely to the rear of the server and attached options. 2. When the server is turned on, air is flowing from the rear of the server at the fan grill. If there is no air flow, the fan is not working. This causes the server to overheat and shut down. 3. Ensure that the SCSI bus and devices are configured correctly and that the last external device in each SCSI chain is terminated correctly.

A problem occurs only occasionally and is difficult to detect.

1. Make sure that the keyboard cable is properly connected to the server. 2. Make sure that the server and the monitor are turned on. 3. Try using another keyboard. All or some keys on the keyboard do not work.

Keyboard, mouse, or pointing-device problems.

The mouse or pointing device does not work.

1. Make sure that the mouse or pointing-device cable is securely connected and the device drivers are installed correctly. 2. Try using another mouse or pointing device.

Memory problems Make sure that: 1. DIMMs are seated properly. 2. You have installed the correct type of memory. 3. If you changed the memory, you updated the memory configuration with the Configuration/Setup Utility program. 4. All banks of memory on the DIMMs are enabled. The server might have automatically disabled a DIMM bank when it detected a problem, or a DIMM bank could have been manually disabled.

The amount of system memory displayed is less than the amount of physical memory installed.

Look in the POST error log for error message 289:

v If the DIMM was disabled by the user or by SAL/EFI:

1. Start the Configuration/Setup Utility program.
2. Enable the DIMM.
3. Save the configuration and restart the server.

v If you continue to get this error, replace the DIMM.

Microprocessor problems The startup (boot) microprocessor is not working properly.

The server indicates a microprocessor error during POST.

Verify that all microprocessors are seated properly. If they are, replace the failed microprocessors.

The server does not recognize all installed processors (loose connection; bent pin(s) on processor(s))

1. Reseat microprocessors and power modules.
2. Check for bent pins on microprocessors.
3. Check cable connections from processor board to power modules.

Monitor problems Some IBM monitors have their own self-tests. If you suspect a problem with your monitor, see the information that comes with the monitor for adjusting and testing instructions.

1. Monitor.

Testing the monitor.

2. Run the AMIDiag program. If diagnostics pass, the problem might be a video driver.
3. I/O board.

The screen is blank. Make sure that: 1. The server power cord is plugged into the server and a working electrical outlet. 2. The monitor cables are connected properly. 3. The monitor is turned on and the brightness and contrast controls are adjusted correctly.

Chapter 6. Symptom-to-FRU index 177

Symptom Suggested action

Page 188 of the IBM 8688 user manual — Error symptoms
Seite 188 · Zum Vergrößern klicken
Seite 188

The monitor works when you turn on the server but goes blank when you start some application programs.

Make sure that:

1. The primary monitor cable is connected to the server.
2. You installed the necessary device drivers for the applications.

The screen is wavy, unreadable, rolling, distorted, or has screen jitter.

If the monitor self-tests show the monitor is working properly, consider the location of the monitor. Magnetic fields around other devices (such as transformers, appliances, fluorescent lights, and other monitors) can cause screen jitter or wavy, unreadable, rolling, or distorted screen images. If this happens, turn off the monitor. (Moving a color monitor while it is turned on might cause screen discoloration.) Then move the device and the monitor at least 305 mm (12 in.) apart. Turn on the monitor.

1. To prevent diskette drive read/write errors, be sure the distance between monitors and diskette drives is at least 76 mm (3 in.).
2. Non-IBM monitor cables might cause unpredictable problems.
3. An enhanced monitor cable with additional shielding is available for the 9521 and 9527 monitors. For information about the enhanced monitor cable, contact your IBM reseller or IBM marketing representative.

Wrong characters appear on the screen.

If the wrong language is displayed, update the SAL/EFI code with the correct language.

No video (loose connection) 1. Reseat boards, VRMs, and microprocessors.

2. Check for bent pins on all connectors.
3. Reseat memory boards and DIMMs.
4. Ensure proper population of DIMM banks.
5. DIMMs.
6. Power module.
7. VRMs.

Option problems Make sure that: 1. The server supports the option. 2. You followed the installation instructions that come with the option. 3. The option is installed correctly. 4. You have not loosened any other installed options or cables. 5. You updated the configuration information using the Configuration/Setup Utility program. Whenever memory or an option is changed, you must update the configuration.

An IBM option that was just installed does not work.

An IBM option that used to work does not work now.

Make sure that all of the option hardware and cable connections are secure.

If the option comes with its own test instructions, use those instructions to test the option.

If the failing option is a SCSI option, verify that: 1. The cables for all external SCSI options are connected correctly. 2. The last option in each SCSI chain, or the end of the SCSI cable, is terminated correctly. 3. Any external SCSI option is turned on. You must turn on an external SCSI option before turning on the server.

Symptom Suggested action

Page 189 of the IBM 8688 user manual — Error symptoms
Seite 189 · Zum Vergrößern klicken
Seite 189

Power problems Make sure that: 1. The power cables are properly connected to the server. 2. The electrical outlet functions properly. 3. The type of memory installed is correct. 4. If you just installed an option, remove it, and restart the server. If the server now turns on, you might have installed more options than the power supply supports. 5. The LEDs on the power supply are on. 6. The operations panel functions properly. 7. VRM I/O board functions properly. 8. RSA system reset. 9. See “Power checkout” on page 74 for further problem determination steps.

The server does not turn on.

The server does not turn off. Verify whether you are using an ACPI or non-ACPI operating system.

If you are using a non-ACPI operating system:

1. Press Ctrl+Alt+Delete.
2. Turn off the system by using the power-control button.

The server does not turn on once back together (loose connection(s) and/or bent pins)

1. Reseat boards and VRMs.
2. Check front panel cable connections.

The server turns on but then turns off with fault light (bent pin(s); short on board)

1. Reseat microprocessor.
2. Microprocessor.

The server starts up but does not POST (loose connection(s); incorrect processor stepping; system speed too high for processors; memory not stuffed in documented order; unsupported or unvalidated DIMMS)

1. Check that screw or other conductive item has not been dropped into system.
2. Reseat boards and VRMs.
3. Check for bent pins on cables.
4. Check for bent pins on processors.

Software problems To determine if problems are caused by the software, verify that: 1. The server has the minimum memory requirements needed to use the software. For memory requirements, refer to the information that comes with the software. Note: If you have just installed an adapter or memory, you might have a memory address conflict. 2. The software is designed to operate on the server. 3. Other software works on the server. 4. The software that you are using works on another system.

Suspected software problem.

If you received any error messages when using the software program, refer to the information that comes with the software for a description of the messages and solutions to the problem.

If the items above are correct and the problem remains, contact your place of purchase.

Verify that: 1. The correct USB device driver is installed. 2. Your operating system supports USB devices. A USB device does not work.

Universal Serial Bus (USB)

Chapter 6. Symptom-to-FRU index 179

Symptom Suggested action · port problems

Page 190 of the IBM 8688 user manual — Power supply LED errors
Seite 190 · Zum Vergrößern klicken
Seite 190

Power supply LED errors

Use the power supply LED information on the following page to troubleshoot power supply problems.

v Power supply v Top power board

Front power on light

Power good indicators (midplane) Description FRU/action

Off No power to system or ac problem.

1. Check ac power to system.
2. Power supply.
3. Top power board.

On Off Off Off DC source power problem

Unplug the three power connectors to the midplane board. If the DC Good LED does not come on:

1. Inspect and replace any damaged power cables.
2. Check ac power to system.
3. Power supply.
4. Top power board.

On On Blinking Off Standby power problem

1. Disconnect the following items from the midplane board to isolate the failing FRU:

a. Light Path cable and SCSI power cable

b. Memory-board assembly

c. Processor-board assembly

d. PCI or PCI-X adapters

e. PCI-X board

f. Remote Supervisor Adapter (watch for lit or flashing LEDs on I/O board)

g. I/O board cable attachments

2. If LEDs are on after removal, replace the offending device.
3. If no LEDs are lit after step 1, replace the following:

a. I/O board

b. Midplane board

On On On Off Failure to power up POWER GOOD problem

1. Check indicators for a failing VRM; replace any failing VRMs.
2. Remove the adapters and disconnect cables and power connectors to all internal and external devices. Turn on the server.
3. If the Power Good LED comes on, replace the adapters and devices one at a time until you isolate the problem.
4. Power supply.
5. Top power board.
6. Midplane board.

On Power is OK. N/A

AC good LED · DC good LED

Page 191 of the IBM 8688 user manual — Hardware status error codes
Seite 191 · Zum Vergrößern klicken
Seite 191

Diagnostic display error codes

The diagnostic display is composed of two seven-segment LEDs on the midplane board. While the server is in standby power mode, the display shows the CMOS programmable logic device (CPLD) revision level. The revision levels of the CPLD are individually reported in the display, as shown in the following table.

P: An

C: An

I: An

After the server is turned on, the diagnostic display presents a two-digit code with a dot. If the dot is at the bottom between the two digits, then the display indicates a Hardware status error code. If the dot is at the top between the two digits, then the display indicates a SAL/EFI progress code.

When the server is first turned on, the hardware status error codes are displayed first, then the SAL/EFI progress codes are presented in the diagnostic display. When video is enabled, the SAL/EFI progress and status indicators can also be viewed from the system console. Codes on the diagnostic display track the SAL/EFI startup progress until startup has been completed.

Under certain conditions, the service processor event log might not contain a message about a FRU fault. For these faults, the server will usually not startup after power on or after reset, and a hardware status error code will appear on the diagnostic display, which will point to the failing FRU.

Hardware status error codes

If the diagnostic display on the midplane board shows a single-digit LED display, replace the I/O board.

Table 13. Phase 1 initial VRM determination error codes

01 (5v VRM not installed) I/O board

02 (+5v PowerGood Fault) 1. I/O board

2. Midplane board

03 (+3.3v VRM not installed) Midplane board

04 (+3.3v PowerGood Fault) Midplane board

05 (+2.5v VRM not installed) Memory board 2.5v VRM (J32)

06 (+2.5v PowerGood Fault) Memory board 2.5v VRM (J32)

07 (+2.5v VRM not installed)* 1. Memory board port 1 2.5v VRM (J33)

2. Memory board port 2 2.5v VRM (J30)

08 (+2.5v PowerGood Fault) 1. Memory board port 1 2.5v VRM (J33)

2. Memory board port 2 2.5v VRM (J30)

09 (+1.8v VRM not installed) Memory board 1.8v VRM (J31)

Chapter 6. Symptom-to-FRU index 181

Show 5 more labels / short text on this page
Display report Device · Processor board · Midplane board · I/O board · Error message/explanation FRU/action
Page 192 of the IBM 8688 user manual — Diagnostic display error codes
Seite 192 · Zum Vergrößern klicken
Seite 192

Table 13. Phase 1 initial VRM determination error codes (continued)

0a (+1.8v PowerGood Fault) Memory board 1.8v VRM (J31)

0b (+1.8v VRM not installed) Processor board 1.8v VRM (J133)

0c (+1,8v PowerGood Fault) Processor board 1.8v VRM (J133)

0d (+1.2v PowerGood Fault) Processor board

0E (PPOD PowerGood Fault) Processor board

*This code is displayed for a few moments after server reset or power on; then, the server continues with the startup process.

Table 14. Phase 2 clock status error codes

11 (33 MHz clock) I/O board

12 (14.3 MHz clock) I/O board

13 (62.5 MHz clock) Midplane board

14 (200 MHz clock) 1. Processor board

2. I/O board

Table 15. Phase 3 subsystem control status error codes

21 (PCI-X board fault or VRM not installed) PCI-X board

22 (PCI-X board fault) PCI-X board

23 (I/O board fault) I/O board

24 (Compatibility RESET failed to deassert) I/O board

25 (Cyclone initialization fault) 1. Memory board

2. Midplane board
3. I/O board

26 (Tornado initialization fault) 1. Processor board

2. Midplane board

27 (Front-side RESET fault. Reset failed to assert.) 1. Processor board

2. Midplane board

28 (Front-side RESET fault. Reset failed to de-assert.) 1. Processor board

2. Midplane board

29 (First Instruction Fetch Failed.) I/O board

Table 16. Phase 4 I2C status error codes

31 (DMC SDA stuck low) I/O board

32 (DMC SCL stuck low) I/O board

33 (Midplane SDA stuck low) Midplane board

34 (Midplane SCL stuck low) Midplane board

Show 4 more labels / short text on this page
Error message/explanation FRU/action · Error message/explanation FRU/action · Error message/explanation FRU/action · Error message/explanation FRU/action
Page 193 of the IBM 8688 user manual — SAL/EFI progress codes
Seite 193 · Zum Vergrößern klicken
Seite 193

Table 17. I/O board PCI status error codes

S:0 (PCI SERR Bus 0) I/O board

S:1 (PCI SERR Bus 1) I/O board

P:0 (PCI SERR Bus 0) I/O board

P:1 (PCI SERR Bus 1) I/O board

SAL/EFI progress codes

00 (Processors are fetching and executing code) 1. Microprocessors

2. Processor board
3. Memory board
4. I/O board
5. Midplane board

1x (FLASH verification in progress) 1. I/O board

2. Processor board
3. Memory board
4. Midplane board

21 (Chipset initialization in progress) 1. Processor board

2. Memory board
3. I/O board

22 (Memory configuration in progress) 1. Check the system-error log.

2. Memory board.
3. Processor board.
4. I/O board.

23 (Memory testing in progress) 1. Check the system-error log.

2. Memory board.
3. Processor board.
4. I/O board.

2C (FLASH code is being shadowed into memory) 1. Check the system-error log.

2. Memory board.
3. I/O board.

30 (System has started up sufficiently to attempt a FLASH recovery)

1. Check the system-error log.
2. Update system firmware.
3. Memory board.
4. I/O board.

3x (SAL initialization is in progress) 1. Check the system-error log.

2. Update system firmware.
3. Memory board.
4. Processor board.
5. I/O board.

Chapter 6. Symptom-to-FRU index 183

Error message/explanation FRU/action · Error message/explanation FRU/action

Page 194 of the IBM 8688 user manual — SCSI error messages
Seite 194 · Zum Vergrößern klicken
Seite 194

4x (PCI initialization is in progress) 1. Check the system-error log.

2. PCI-X board.
3. I/O board.

53 (Video initialization is in progress) 1. Check the system-error log.

2. Update system firmware.
3. I/O board.

8x (EFI initialization is in progress) 1. Check the system-error log.

2. Update system firmware.
3. I/O board.

91 (PCI initialization is in progress) 1. Check the system-error log.

2. Update system firmware.
3. I/O board.

92 (ACPI initialization is in progress) 1. Check the system-error log.

2. Update system firmware.
3. I/O board.

93 (MCA/INIT initialization is in progress) 1. Check the system-error log.

2. I/O board.

94 (SMBIOS initialization is in progress) 1. Check the system-error log.

2. Remote Supervisor Adapter.
3. I/O board.

95 (EFI is being started) 1. Check the system-error log.

2. Update system firmware.
3. I/O board.

SCSI error messages

1. External SCSI devices must be powered-on before you power-on the server.

One or more of the following might be causing the problem:

2. The cables for all external SCSI devices are connected correctly.

v A failing SCSI device (adapter, drive, controller)

3. If you have attached an external SCSI device to the server, make sure the external SCSI termination is set to automatic.

v An improper SCSI configuration or SCSI termination jumper setting

4. The last device in each SCSI chain is terminated correctly.
5. The SCSI devices are configured correctly.

v Duplicate SCSI IDs in the same SCSI chain

v A missing or improperly installed SCSI terminator

v A defective SCSI terminator

v An improperly installed cable

v A defective cable

Error message/explanation FRU/action · Error message FRU/action · All SCSI Errors

Page 195 of the IBM 8688 user manual — Undetermined problems
Seite 195 · Zum Vergrößern klicken
Seite 195

Ethernet error messages

Diagnostic error messages prompted by the Ethernet controller are on the Resource CD.

Undetermined problems

You are here because the diagnostic tests did not identify the failure, the Devices List is incorrect, or the system is inoperative.

Check the LEDs on all the power supplies (see “Power supply LED errors” on page 180). If the LEDs indicate the power supplies are working correctly, return here and do the following: 1. Turn off the server. 2. Be sure the system is cabled correctly. 3. Remove or disconnect the following (one at a time) until you find the failure (power-on the server and reconfigure each time). v Any external devices v Surge suppressor device (on the server) v Modem, printer, mouse, or non-IBM devices v Each adapter v Hard disk drives v Memory modules (minimum requirement = 1 GB (4 x 512 MB DIMMs))

a. 1 microprocessor with power module b. 4 x 512 MB DIMMs c. 1 power supply d. 1 processor board e. 1 memory board f. Midplane board g. I/O board h. PCI-X board 4. Turn on the server. If the problem remains, suspect the following FRUs in the order listed: v Power supply v Top power board v Processor board v Memory board v Midplane board v PCI-X board v I/O board

Chapter 6. Symptom-to-FRU index 185

Page 196 of the IBM 8688 user manual — Ethernet error messages
Seite 196 · Zum Vergrößern klicken
Seite 196
Page 196 of the IBM 8688 user manual — Ethernet error messages
Page 197 of the IBM 8688 user manual — System
Seite 197 · Zum Vergrößern klicken
Seite 197

Chapter 7. Parts listing xSeries 450 Type 8688

The following Parts information is for the xSeries 450, Type 8688, Models 4RX,5RX, 6RX.

System

IBM 8688 — System diagram (page 197)
Abb. 83 · System

© Copyright IBM Corp. 2003 187

Page 198 of the IBM 8688 user manual — Chapter 7. Parts listing xSeries 450 Type 8688
Seite 198 · Zum Vergrößern klicken
Seite 198

Index xSeries 450 (Models 4RX, 5RX, 6RX) FRU No. CRU/FRU 1 Memory-board assembly (4RX, 5RX, 6 RX) see “Figure A” on page 190. 59P3676 FRU 2 Power module (4RX, 5RX, 6 RX) 59P3671 FRU 3 Processor-board assembly (4RX, 5RX, 6 RX) 59P3674 FRU 4 Retention bracket (4RX, 5RX, 6 RX) 48P7116 FRU 5 Panel, rear (4RX, 5RX, 6 RX) 73P6864 FRU 6 Chassis, 4U x 26 in. (4RX, 5RX, 6 RX) 49P3184 FRU 7 Bezel, 4U front (4RX, 5RX, 6 RX) 24P1259 CRU 8 CD-RW/DVD drive (4RX, 5RX, 6 RX) 08K9820 CRU 9 Bezel, slim hard disk drive (4RX, 5RX, 6 RX) 06P6245 FRU 10 Light Path card (4RX, 5RX, 6 RX) 03K9039 FRU 11 Power supply with mounting, 1050W (4RX, 5RX, 6 RX) 74P4347 CRU 12 Media extract mechanism (4RX, 5RX, 6 RX) 03K9047 FRU 13 Power/reset card assembly (4RX, 5RX, 6 RX) 59P5814 FRU 14 Fan (CPU fan assembly) 03K9048 CRU 15 PCI-X frame assembly — See “Figure B” on page 191. 73P6849 FRU 16 PCI fan assembly (4RX, 5RX, 6 RX) 03K9049 CRU 17 Hard disk drive card (4RX, 5RX, 6 RX) 59P3678 FRU 18 Media bay card (4RX, 5RX, 6 RX) 03K9036 FRU 19 Processor-board VRM (4RX, 5RX, 6 RX) 74P4343 FRU 20 Baffle, Microprocessor module (4RX, 5RX, 6RX) 59P3672 FRU 21 Microprocessor, 400/900 with hex wrench - 1.5 GHz (4RX) 73P9697 FRU 21 Microprocessor, 400/1000 with hex wrench - 1.5 GHz (5RX) 73P9698 FRU 21 Microprocessor, 400/1000 with hex wrench - 3.0 GHz (6RX) 73P9699 FRU 22 Top power board (4RX, 5RX, 6 RX) 03K9038 FRU 23 Top cover assembly (4RX, 5RX, 6 RX) 03K9043 FRU AC box assembly mechanism (4RX, 5RX, 6 RX) 49P2990 FRU Battery, 3.0V (4RX, 5RX, 6 RX) 33F8354 CRU Bezel, media bay (4RX, 5RX, 6 RX) 24P1081 FRU Cable, DC (4RX, 5RX, 6 RX) 24P1057 FRU Cable, DC power 16 POS (4RX, 5RX, 6 RX) 24P1059 FRU Cable, I2C SCSI (4RX, 5RX, 6 RX) 24P1061 FRU Cable, SCSI (4RX, 5RX, 6 RX) 24P1063 FRU Cable, active PCI (4RX, 5RX, 6 RX) 24P1067 FRU Cable, Light Path (4RX, 5RX, 6 RX) 03K9332 FRU Cable, media bay (4RX, 5RX, 6 RX) 03K9333 FRU Cable, CPU fan (4RX, 5RX, 6 RX) 03K9334 FRU Cable, I2C etc. (4RX, 5RX, 6 RX) 03K9335 FRU Cable, USB (4RX, 5RX, 6 RX) 03K9336 FRU Cable, external SCSI (4RX, 5RX, 6 RX) 32P8314 FRU Cable, pigtail, SMP fan assembly (4RX, 5RX, 6 RX) 32P8328 FRU Cable, memory LED (4RX, 5RX, 6 RX) 59P3680 FRU Cable, power module (4RX, 5RX, 6 RX) 59P6918 FRU Cover, system service label (4RX, 5RX, 6 RX) 73P7085 FRU Enterprise cable management arm (4RX, 5RX, 6 RX) 31P6119 FRU Frame (4RX, 5RX, 6 RX) 73P6849 FRU Insulator, PCI cover (4RX, 5RX, 6 RX) 24P1094 FRU Label group (4RX, 5RX, 6 RX) 73P6916 FRU Label, system service (4RX, 5RX, 6 RX) 73P9665 FRU Left EIA side flange assembly (4RX, 5RX, 6 RX) 00N7190 FRU Microprocessor cam assembly (4RX, 5RX, 6 RX) 24P1071 FRU

Page 199 of the IBM 8688 user manual — 24P1217 CRU
Seite 199 · Zum Vergrößern klicken
Seite 199

Index xSeries 450 (Models 4RX, 5RX, 6RX) FRU No. CRU/FRU Miscellaneous parts kit (4RX, 5RX, 6 RX) v I/O brackets (3) v Small EMC clips (10) v Adapter arm bracket cable (1) v PCI card guide (1) v PCI door latch (1) v Switch, Light Path card (1) v Slide rails, Light Path card (2) v EMC shields (2) v VRM clips (2) v Slotted screws (10)

24P1217 CRU

PCI hot-swap card (4RX, 5RX, 6 RX) 73P6869 FRU PDU cord (4RX, 5RX, 6 RX) 36L8886 FRU Power backplane (4RX, 5RX, 6 RX) 03K9038 FRU Right EIA side flange assembly (4RX, 5RX, 6 RX) 00N7192 FRU Slides with brackets (4RX, 5RX, 6 RX) 37L6579 FRU VRM, 40A, 12V (4RX, 5RX, 6 RX) 49P2120 FRU VRM clip, right angle (4RX, 5RX, 6 RX) 24P1285 FRU

Chapter 7. Parts listing xSeries 450 Type 8688 189

Page 200 of the IBM 8688 user manual — Figure A
Seite 200 · Zum Vergrößern klicken
Seite 200

Figure A

IBM 8688 — Figure A diagram (page 200)
Abb. 84 · Figure A

Index xSeries 450 (Models 4RX, 5RX, 6RX) FRU No. CRU/FRU 1 Memory switch card (4RX, 5RX, 6 RX) 59P3677 FRU 2 Memory VRM, 16, 12V (4RX, 5RX, 6RX) 73P4343 FRU 3 Memory-board assembly (4RX, 5RX, 6 RX) 59P3676 FRU 4 Memory, 512 DIMM PC2100 ECC (4RX, 5RX, 6RX) 73P2032 CRU 4 Memory, 1 GB DIMM PC2100 ECC (4RX, 5RX, 6 RX) 73P2033 CRU 4 Memory, 2 GB DIMM PC2100 ECC (4RX, 5RX, 6 RX) 73P2035 CRU

Page 201 of the IBM 8688 user manual — Figure B
Seite 201 · Zum Vergrößern klicken
Seite 201

Figure B

IBM 8688 — Figure B diagram (page 201)
Abb. 85 · Figure B

Index xSeries 450 (Models 4RX, 5RX, 6RX) FRU No. CRU/FRU 1 PCI spacer (4RX, 5RX, 6 RX) 03K9050 FRU 2 PCI-X board (4RX, 5RX, 6 RX) 02R2399 FRU 3 Active PCI assembly (4RX, 5RX, 6 RX) 73P6869 FRU 4 PCI-X frame assembly (4RX, 5RX, 6 RX) 73P6849 FRU 5 Midplane board (4RX, 5RX, 6 RX) 59P3675 FRU 6 Midplane VRM, 16, 12V (4RX, 5RX, 6 RX) 49P2120 FRU 7 Remote system management adapter (4RX, 5RX, 6 RX) 59P2952 FRU 8 Riser card (4RX, 5RX, 6 RX) 03K9031 FRU 9 VRM, 40, 12V (4RX, 5RX, 6 RX) 49P2120 FRU 10 I/O board (4RX, 5RX, 6 RX) 73P9660 FRU PCI insulator (4RX, 5RX, 6 RX) 24P1094 FRU

Chapter 7. Parts listing xSeries 450 Type 8688 191

Page 202 of the IBM 8688 user manual — Keyboard CRUs
Seite 202 · Zum Vergrößern klicken
Seite 202

Keyboard CRUs

Keyboard FRU No. US English 37L2551 French Canadian 37L2552 LA Spanish 37L2553 Arabic 37L2555 Belgium/French 37L2556 Belgium/UK 37L2557 Bulgarian 37L2558 Czech 37L2559 Danish 37L2560 Dutch 37L2561 French 37L2562 German 37L2563 Greek 37L2564 Hebrew 37L2565 Hungarian 37L2566 Korean 02K0901 Iceland 37L2567 Italy 37L2568 Norwegian 37L2569 Polish 37L2570 Portuguese 37L2571 Romanian 37L2572 Russian 37L2573 Serbian/Cyrillic 37L2574 Slavic 37L2575 Spanish 37L2576 Swedish/Finn 37L2577 Swiss, F/G 37L2578 Turkish (179) 37L2579 Turkish (440) 37L2580 UK English 37L2581 Yugosl/Lat 37L2582 US English-EMEA 37L2583 Chinese/US 37L2585 Thailand 37L2587 French Canadian 37L0913

Page 203 of the IBM 8688 user manual — 76H4865
Seite 203 · Zum Vergrößern klicken
Seite 203

Power cord CRUs

Power cord FRU No. China (PRC) 01K9851 Japan 01K9853 Thailand 12J5120 Israel 12J5122 Bangladesh, Burma, India, Pakistan, South Africa, Sri Lanka 12J5124 Chile, Ethiopia, Italy, Libya, Somalia 12J5126 Argentina, Australia, New Zealand, Papua New Guinea, Paraguay, Uruguay, Western Samoa 12J5128 Antigua, Bahrain, Brunei, Channel Islands, China (Hong Kong S.A.R.), Cyprus, Dubai, Fiji, Ghana, Iraq, Ireland, Kenya, Kuwait, Malawi, Malaysia, Malta, Nepal, Nigeria, Polynesia, Qatar, Sierra Leone, Singapore, Tanzania, Uganda, United Kingdom, Yemen, Zambia

12J5987

Afghanistan, Algeria, Andorra, Angola, Austria, Belgium, Benin, Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Rep., Chad, China (Macau S.A.R.), Czech Republic, Egypt, Finland, France, French Guiana, Germany, Greece, Guinea, Hungary, Iceland, Indonesia, Iran, Ivory Coast, Jordan, Lebanon, Luxembourg, Malagasy, Mali, Martinique, Mauritania, Mauritius, Monaco, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Romania, Senegal, Slovakia, Spain, Sudan, Sweden, Syria, Togo, Tunisia, Turkey, former USSR, Vietnam, former Yugoslavia, Zaire, Zimbabwe

55H6643

Denmark, Switzerland, Liechtenstein 55H6646 Bahamas, Barbados, Bermuda, Bolivia, Brazil, Canada, Cayman Islands, Colombia, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Korea (South), Liberia, Mexico, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad (West Indies), Venezuela

76H4865

United States of America 6952301 (110) 1838574 (220) 36L8886 (220V/15A)

Chapter 7. Parts listing xSeries 450 Type 8688 193

Page 204 of the IBM 8688 user manual — Power cord CRUs
Seite 204 · Zum Vergrößern klicken
Seite 204
Page 204 of the IBM 8688 user manual — Power cord CRUs
Page 205 of the IBM 8688 user manual — Getting help and information from the World Wide Web
Seite 205 · Zum Vergrößern klicken
Seite 205

Appendix A. Getting help and technical assistance

If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This appendix contains information about where to go for additional information about IBM and IBM products, what to do if you experience a problem with your xSeries or IntelliStation® system, and whom to call for service, if it is necessary.

Before you call

Before you call, make sure that you have taken these steps to try to solve the problem yourself: v Check all cables to make sure that they are connected.

v Check the power switches to make sure that the system is turned on. v Use the troubleshooting information in your system documentation, and use the diagnostic tools that come with your system. v Go to the IBM Support Web site at http://www.ibm.com/pc/support/ to check for technical information, hints, tips, and new device drivers. v Use an IBM discussion forum on the IBM Web site to ask questions.

You can solve many problems without outside assistance by following the troubleshooting procedures that IBM provides in the online help or in the publications that are provided with your system and software. The information that comes with your system also describes the diagnostic tests that you can perform. Most xSeries and IntelliStation systems, operating systems, and programs come with information that contains troubleshooting procedures and explanations of error messages and error codes. If you suspect a software problem, see the information for the operating system or program.

Using the documentation

Information about your IBM xSeries or IntelliStation system and preinstalled software, if any, is available in the documentation that comes with your system. That documentation includes printed books, online books, readme files, and help files. See the troubleshooting information in your system documentation for instructions for using the diagnostic programs. The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software. IBM maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates. To access these pages, go to http://www.ibm.com/pc/support/ and follow the instructions. Also, you can order publications through the IBM Publications Ordering System at http://www.elink.ibmlink.ibm.com/public/applications/publications/cgibin/pbi.cgi

Getting help and information from the World Wide Web

On the World Wide Web, the IBM Web site has up-to-date information about IBM xSeries and IntelliStation products, services, and support. The address for IBM xSeries information is http://www.ibm.com/eserver/xseries/ The address for IBM IntelliStation information is http://www.ibm.com/pc/intellistation/

© Copyright IBM Corp. 2003 195

Page 206 of the IBM 8688 user manual — Hardware service and support
Seite 206 · Zum Vergrößern klicken
Seite 206

You can find service information for your IBM products, including supported options, at http://www.ibm.com/pc/support/

Software service and support

Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with xSeries servers, IntelliStation workstations, and appliances. For information about which products are supported by Support Line in your country or region, go to http://www.ibm.com/services/sl/products/

For more information about Support Line and other IBM services, go to http://www.ibm.com/services/ or go to http://www.ibm.com/planetwide/ for support telephone numbers. In the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378).

Hardware service and support

You can receive hardware service through IBM Integrated Technology Services or through your IBM reseller, if your reseller is authorized by IBM to provide warranty service. Go to http://www.ibm.com/planetwide/ for support telephone numbers, or in the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378).

In the U.S. and Canada, hardware service and support is available 24 hours a day, 7 days a week. In the U.K., these services are available Monday through Friday, from 9 a.m. to 6 p.m.

Page 207 of the IBM 8688 user manual — General safety
Seite 207 · Zum Vergrößern klicken
Seite 207

Appendix B. Related service information

The service procedures are designed to help you isolate problems. They assume that you have model-specific training on all servers, or that you are familiar with the servers, functions, terminology, and service information provided in this manual.

Safety information

The following section contains the safety information that you need to be familiar with before servicing an IBM server.

General safety

Follow these rules to ensure general safety: v Observe good housekeeping in the area of the machines during and after maintenance. v When lifting any heavy object: 1. Ensure you can stand safely without slipping. 2. Distribute the weight of the object equally between your feet.

3. Use a slow lifting force. Never move suddenly or twist when you attempt to lift. 4. Lift by standing or by pushing up with your leg muscles; this action removes the strain from the muscles in your back. Do not attempt to lift any objects that weigh more than 16 kg (35 lb) or objects that you think are too heavy for you.

v Do not perform any action that causes hazards to the customer, or that makes the equipment unsafe. v Before you start the machine, ensure that other service representatives and the customer’s personnel are not in a hazardous position. v Place removed covers and other parts in a safe place, away from all personnel, while you are servicing the machine. v Keep your tool case away from walk areas so that other people will not trip over it. v Do not wear loose clothing that can be trapped in the moving parts of a machine. Ensure that your sleeves are fastened or rolled up above your elbows. If your hair is long, fasten it. v Insert the ends of your necktie or scarf inside clothing or fasten it with a nonconductive clip, approximately 8 centimeters (3 inches) from the end. v Do not wear jewelry, chains, metal-frame eyeglasses, or metal fasteners for your clothing. Remember: Metal objects are good electrical conductors.

v Wear safety glasses when you are: hammering, drilling soldering, cutting wire, attaching springs, using solvents, or working in any other conditions that might be hazardous to your eyes.

v After service, reinstall all safety shields, guards, labels, and ground wires. Replace any safety device that is worn or defective. v Reinstall all covers correctly before returning the machine to the customer.

© Copyright IBM Corp. 2003 197

Page 208 of the IBM 8688 user manual — Electrical safety
Seite 208 · Zum Vergrößern klicken
Seite 208

Electrical safety

Observe the following rules when working on electrical equipment.

handles covered with a soft material that does not insulate you when working with live electrical currents.

Many customers have, near their equipment, rubber floor mats that contain small conductive fibers to decrease electrostatic discharges. Do not use this type of mat to protect yourself from electrical shock. v Find the room emergency power-off (EPO) switch, disconnecting switch, or electrical outlet. If an electrical accident occurs, you can then operate the switch or unplug the power cord quickly. v Do not work alone under hazardous conditions or near equipment that has hazardous voltages.

v Disconnect all power before: – Performing a mechanical inspection – Working near power supplies – Removing or installing main units

v Before you start to work on the machine, unplug the power cord. If you cannot unplug it, ask the customer to power-off the wall box that supplies power to the machine and to lock the wall box in the off position. v If you need to work on a machine that has exposed electrical circuits, observe the following precautions: – Ensure that another person, familiar with the power-off controls, is near you. Remember: Another person must be there to switch off the power, if necessary. – Use only one hand when working with powered-on electrical equipment; keep the other hand in your pocket or behind your back.

Remember: There must be a complete circuit to cause electrical shock. By observing the above rule, you may prevent a current from passing through your body. – When using testers, set the controls correctly and use the approved probe leads and accessories for that tester. – Stand on suitable rubber mats (obtained locally, if necessary) to insulate you from grounds such as metal floor strips and machine frames. Observe the special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information. Use extreme care when measuring high voltages. v Regularly inspect and maintain your electrical hand tools for safe operational condition.

Page 209 of the IBM 8688 user manual — Safety inspection guide
Seite 209 · Zum Vergrößern klicken
Seite 209

v Do not use worn or broken tools and testers. v Never assume that power has been disconnected from a circuit. First, check that it has been powered-off. v Always look carefully for possible hazards in your work area. Examples of these hazards are moist floors, nongrounded power extension cables, power surges, and missing safety grounds. v Do not touch live electrical circuits with the reflective surface of a plastic dental mirror. The surface is conductive; such touching can cause personal injury and machine damage. v Do not service the following parts with the power on when they are removed from their normal operating places in a machine: – Power supply units – Pumps – Blowers and fans – Motor generators

and similar units. (This practice ensures correct grounding of the units.) v If an electrical accident occurs: – Use caution; do not become a victim yourself. – Switch off power. – Send another person to get medical aid.

Safety inspection guide

The intent of this inspection guide is to assist you in identifying potentially unsafe conditions on these products. Each machine, as it was designed and built, had required safety items installed to protect users and service personnel from injury. This guide addresses only those items. However, good judgment should be used to identify potential safety hazards due to attachment of non-IBM features or options not covered by this inspection guide.

If any unsafe conditions are present, you must determine how serious the apparent hazard could be and whether you can continue without first correcting the problem.

Consider these conditions and the safety hazards they present: v Electrical hazards, especially primary power (primary voltage on the frame can cause serious or fatal electrical shock). v Explosive hazards, such as a damaged CRT face or bulging capacitor v Mechanical hazards, such as loose or missing hardware

The guide consists of a series of steps presented in a checklist. Begin the checks with the power off, and the power cord disconnected.

Checklist: 1. Check exterior covers for damage (loose, broken, or sharp edges). 2. Turn off the server. Disconnect the power cord. 3. Check the power cord for: a. A third-wire ground connector in good condition. Use a meter to measure third-wire ground continuity for 0.1 ohm or less between the external ground pin and frame ground. b. The power cord should be the appropriate type as specified in the parts listings. c. Insulation must not be frayed or worn.

Appendix B. Related service information 199

Page 210 of the IBM 8688 user manual — Grounding requirements
Seite 210 · Zum Vergrößern klicken
Seite 210
4. Remove the cover. 5. Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations. 6. Check inside the unit for any obvious unsafe conditions, such as metal filings, contamination, water or other liquids, or signs of fire or smoke damage. 7. Check for worn, frayed, or pinched cables. 8. Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered with.

Handling static-sensitive devices

Any server part containing transistors or integrated circuits (ICs) should be considered sensitive to electrostatic discharge (ESD), or static-sensitive. ESD damage can occur when there is a difference in charge between objects. Protect against ESD damage by equalizing the charge so that the server, the part, the work mat, and the person handling the part are all at the same charge.

When handling static-sensitive parts: v Keep the parts in protective packages until they are inserted into the product. v Avoid contact with other people.

v Wear a properly grounded wrist strap against your skin to help eliminate static electricity from your body. v Prevent the part from touching your clothing. Most clothing is insulative and retains a charge even when you are wearing a wrist strap. v Use the black side of a grounded work mat to provide a static-free work surface. The mat is especially useful when handling static-sensitive devices. v Select a grounding system, such as those in the following list, to provide protection that meets the specific service requirement.

against electrostatic discharge damage. – Attach the ESD ground clip to any frame ground, ground braid, or green-wire ground. – Use an ESD common ground or reference point when working on a double-insulated or battery-operated system. You can use coax or connector-outside shells on these systems. – Use the round ground-prong of the ac plug on ac-operated servers.

Grounding requirements

Electrical grounding of the server is required for operator safety and correct system function. Proper grounding of the electrical outlet can be verified by a certified electrician.

Page 211 of the IBM 8688 user manual — Safety notices (multilingual translations)
Seite 211 · Zum Vergrößern klicken
Seite 211

Safety notices (multilingual translations)

The caution and danger safety notices in this section are provided in the following languages: v English v Brazilian/Portuguese v Chinese v French v German v Italian v Japanese v Korean v Spanish

a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in this section.

For example, if a caution statement begins with a number 1, translations for that caution statement appear in this section under statement 1.

Be sure to read all caution and danger statements before performing any of the instructions.

Appendix B. Related service information 201

Page 212 of the IBM 8688 user manual — DANGER
Seite 212 · Zum Vergrößern klicken
Seite 212

Statement 1:

DANGER

Electrical current from power, telephone, and communication cables is hazardous.

To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this product. v When possible, use one hand only to connect or disconnect signal cables. v Never turn on any equipment when there is evidence of fire, water, or structural damage.

v Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures.

v Connect and disconnect cables as described in the following table when installing, moving, or opening covers on this product or attached devices.

To ConnectTo Disconnect:
1. Turn everything OFF.
1. Turn everything OFF.
2. First, attach all cables to devices.
2. First, remove power cords from outlet.
3. Attach signal cables to connectors.
3. Remove signal cables from connectors.
4. Attach power cords to outlet.
4. Remove all cables from devices.
5. Turn device ON.
Page 213 of the IBM 8688 user manual — DANGER
Seite 213 · Zum Vergrößern klicken
Seite 213

Statement 2:

Do notv Throw or immerse into water

v Heat to more than 100°C (212°F) v Repair or disassemble

Dispose of the battery as required by local ordinances or regulations.

Statement 3:

v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure.

DANGER

Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following.

Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.

Appendix B. Related service information 203

Page 214 of the IBM 8688 user manual — Safety notices (multilingual translations)
Seite 214 · Zum Vergrößern klicken
Seite 214

Statement 4:

≥18 kg (39.7 lb) ≥32 kg (70.5 lb) ≥55 kg (121.2 lb)

Statement 5:

Page 215 of the IBM 8688 user manual — Edition notice
Seite 215 · Zum Vergrößern klicken
Seite 215

Appendix C. Notices

This information was developed for products and services offered in the U.S.A.

IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:

IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A.

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk.

IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.

Edition notice

© Copyright International Business Machines Corporation 2003. All rights reserved.

U.S. Government Users Restricted Rights — Use, duplication, or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

© Copyright IBM Corp. 2003 237

Page 216 of the IBM 8688 user manual — Important notes
Seite 216 · Zum Vergrößern klicken
Seite 216

Trademarks

The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both:

Active Memory PS/2 Active PCI ServeRAID Active PCI-X ServerGuide Alert on LAN ServerProven C2T Interconnect TechConnect Chipkill ThinkPad EtherJet Tivoli e-business logo Tivoli Enterprise Eserver Update Connector FlashCopy Wake on LAN IBM XA-32 IntelliStation XA-64 NetBAY X-Architecture Netfinity XceL4 NetView XpandOnDemand Predictive Failure Analysis xSeries

Lotus, Lotus Notes, SmartSuite, and Domino are trademarks of Lotus Development Corporation and/or IBM Corporation in the United States, other countries, or both.

Intel, MMX, and Pentium are trademarks of Intel Corporation in the United States, other countries, or both.

Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both.

UNIX is a registered trademark of The Open Group in the United States and other countries.

Java and all Java-based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.

Important notes

Processor speeds indicate the internal clock speed of the microprocessor; other factors also affect application performance.

CD-ROM drive speeds list the variable read rate. Actual speeds vary and are often less than the maximum possible.

When referring to processor storage, real and virtual storage, or channel volume, KB stands for approximately 1000 bytes, MB stands for approximately 1 000 000 bytes, and GB stands for approximately 1 000 000 000 bytes.

Page 217 of the IBM 8688 user manual — Battery return program
Seite 217 · Zum Vergrößern klicken
Seite 217

When referring to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible capacity may vary depending on operating environments.

Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives available from IBM.

Maximum memory may require replacement of the standard memory with an optional memory module.

IBM makes no representation or warranties regarding non-IBM products and services that are ServerProven, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. These products are offered and warranted solely by third parties.

IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM.

Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.

Product recycling and disposal

This unit contains materials such as circuit boards, cables, electromagnetic compatibility gaskets, and connectors which may contain lead and copper/beryllium alloys that require special handling and disposal at end of life. Before this unit is disposed of, these materials must be removed and recycled or discarded according to applicable regulations. IBM offers product-return programs in several countries. Information on product recycling offerings can be found on IBM’s Internet site at http://www.ibm.com/ibm/environment/products/prp.shtml

Battery return program

This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult your user manual or service manual for specific battery information. The battery must be recycled or disposed of properly. Recycling facilities may not be available in your area. For information on disposal of batteries outside the United States, go to http://www.ibm.com/ibm/environment/products/batteryrecycle.shtml or contact your local waste disposal facility.

In the United States, IBM has established a collection process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333. Have the IBM part number listed on the battery available prior to your call.

In the Netherlands, the following applies.

Appendix C. Notices 239

Page 218 of the IBM 8688 user manual — European Union EMC Directive conformance statement
Seite 218 · Zum Vergrößern klicken
Seite 218

Electronic emission notices

Federal Communications Commission (FCC) statement

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.IBM is not responsible for any radio or television interference causedby using other than recommended cables and connectors or by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Industry Canada Class A emission compliance statement

This Class A digital apparatus complies with Canadian ICES-003.

Avis de conformité à la réglementation d’Industrie Canada

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

Australia and New Zealand Class A statement

United Kingdom telecommunications safety requirement

This apparatus is approved under approval number NS/G/1234/J/100003 for indirect connection to public telecommunication systems in the United Kingdom.

European Union EMC Directive conformance statement

This product is in conformity with the protection requirements of EU Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards.

Page 219 of the IBM 8688 user manual — Taiwanese Class A warning statement
Seite 219 · Zum Vergrößern klicken
Seite 219

This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN 55022. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.

Taiwanese Class A warning statement

Chinese Class A warning statement

Japanese Voluntary Control Council for Interference (VCCI) statement

Power cords

For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.

IBM power cords used in the United States and Canada are listed by Underwriter’s Laboratories (UL) and certified by the Canadian Standards Association (CSA).

Appendix C. Notices 241

Page 220 of the IBM 8688 user manual — Taiwanese Class A warning statement
Seite 220 · Zum Vergrößern klicken
Seite 220

For units intended to be operated at 115 volts: Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a parallel blade, grounding-type attachment plug rated 15 amperes, 125 volts.

For units intended to be operated at 230 volts (U.S. use): Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a tandem blade, grounding-type attachment plug rated 15 amperes, 250 volts.

For units intended to be operated at 230 volts (outside the U.S.): Use a cord set with a grounding-type attachment plug. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed.

IBM power cords for a specific country or region are usually available only in that country or region.

IBM power cord part number Used in these countries and regions

13F9940 Australia, Fiji, Kiribati, Nauru, New Zealand, Papua New Guinea

13F9979 Afghanistan, Albania, Algeria, Andorra, Angola, Armenia, Austria, Azerbaijan, Belarus, Belgium, Benin, Bosnia and Herzegovina, Bulgaria, Burkina Faso, Burundi, Cambodia, Cameroon, Cape Verde, Central African Republic, Chad, Comoros, Congo (Democratic Republic of), Congo (Republic of), Cote D’Ivoire (Ivory Coast), Croatia (Republic of), Czech Republic, Dahomey, Djibouti, Egypt, Equatorial Guinea, Eritrea, Estonia, Ethiopia, Finland, France, French Guyana, French Polynesia, Germany, Greece, Guadeloupe, Guinea, Guinea Bissau, Hungary, Iceland, Indonesia, Iran, Kazakhstan, Kyrgyzstan, Laos (People’s Democratic Republic of), Latvia, Lebanon, Lithuania, Luxembourg, Macedonia (former Yugoslav Republic of), Madagascar, Mali, Martinique, Mauritania, Mauritius, Mayotte, Moldova (Republic of), Monaco, Mongolia, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Reunion, Romania, Russian Federation, Rwanda, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Slovakia, Slovenia (Republic of), Somalia, Spain, Suriname, Sweden, Syrian Arab Republic, Tajikistan, Tahiti, Togo, Tunisia, Turkey, Turkmenistan, Ukraine, Upper Volta, Uzbekistan, Vanuatu, Vietnam, Wallis and Futuna, Yugoslavia (Federal Republic of), Zaire

14F0015 Bangladesh, Lesotho, Maceo, Maldives, Namibia, Nepal, Pakistan, Samoa, South Africa, Sri Lanka, Swaziland, Uganda

14F0033 Abu Dhabi, Bahrain, Botswana, Brunei Darussalam, Channel Islands, China (Hong Kong S.A.R.), Cyprus, Dominica, Gambia, Ghana, Grenada, Iraq, Ireland, Jordan, Kenya, Kuwait, Liberia, Malawi, Malaysia, Malta, Myanmar (Burma), Nigeria, Oman, Polynesia, Qatar, Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Seychelles, Sierra Leone, Singapore, Sudan, Tanzania (United Republic of), Trinidad and Tobago, United Arab Emirates (Dubai), United Kingdom, Yemen, Zambia, Zimbabwe

14F0069 Chile, Italy, Libyan Arab Jamahiriya

02K0546 China · 13F9997 Denmark · 14F0051 Liechtenstein, Switzerland

Page 221 of the IBM 8688 user manual — Taiwanese Class A warning statement
Seite 221 · Zum Vergrößern klicken
Seite 221

IBM power cord part number Used in these countries and regions

1838574 Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Brazil, Caicos Islands, Canada, Cayman Islands, Costa Rica, Colombia, Cuba, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Japan, Mexico, Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Taiwan, United States of America, Venezuela

24P6858 Korea (Democratic People’s Republic of), Korea (Republic of)

36L8880 Argentina, Paraguay, Uruguay

6952300 Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Caicos Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Mexico, Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Thailand, Taiwan, United States of America, Venezuela

Appendix C. Notices 243

Show 4 more labels / short text on this page
14F0087 Israel · 34G0232 Japan · 49P2078 India · 49P2110 Brazil
Page 222 of the IBM 8688 user manual — Taiwanese Class A warning statement
Seite 222 · Zum Vergrößern klicken
Seite 222
Page 222 of the IBM 8688 user manual — Taiwanese Class A warning statement
Page 224 of the IBM 8688 user manual — F fan assemblies 107
Seite 224 · Zum Vergrößern klicken
Seite 224

considerations 99 order of installation 98 specifications 3, 4 supported 3 DOS configuration utility 20 DVD

replacing and troubleshooting 107 replacing fans 1 and 2 107 replacing fans 3 and 4 108 FCC Class A notice 240 features and specifications 3 features, server 4 field replaceable units (FRUs) 115, 187 firmware, updating 39 forgotten power-on password, bypassing 14

See also k test read test 45 DVD/CD-RW

G general checkout 33

E edit batch parameters 63 electrical input 3 electronic emission Class A notice 240 environment

H handling static-sensitive devices 78 hard disk drive

air temperature 3 humidity 3 error codes

backplane 138 IDE 95 installing 95 problems 176 heat output 3 hot-swap and hot-plug devices

Advanced System Management 170 ATAPI removables test 162 diagnostic 70, 159 diagnostic display 181 hardware status 181 IDE CD test 161 IDE DVD-ROM drive test 164 LED 175 memory test 174 RXE port 173 SCSI test 164 serial port test 169 system 159 USB test 167 video test 167 error log

power supplies 90 hot-swap power supply

I I/O board 130 information label 1 installation

order, microprocessors 100 installing

adapters 93 battery 109 DIMMs 98 hot-swap power supply 90 memory module 98 microprocessors 100 options 77 PCI adapters 92 integrated functions 3 interactive test 67 intermittent problems 177 internal connectors

entries 149 viewer 42 error logs 36 error symptoms 176 Ethernet

configuring settings 20 diagnostic tests 70 error messages 185 LAN port, cabling 19 troubleshooting 75 Ethernet controller 4 configuring 31 messages 76 troubleshooting 75 expansion enclosure problems 176 expansion slots 3 location 92 type 92 external

memory board 80 PCI-X 86 processor board 82, 83

J jumper

power-on password override 14

F fan assemblies 107

Show 5 more labels / short text on this page
DIMMs · fans · drive specification 3 · installing 90 · cabling 111
Page 225 of the IBM 8688 user manual — P parameters
Seite 225 · Zum Vergrößern klicken
Seite 225

K keyboard

microprocessor specifications 3 midplane board

replacing 125 voltage regulator module (VRM) 126 monitor problems 177 mouse problems 177

customer replaceable units (CRUs) 192 problems 177

L LAN, connecting 18 LED

N network connection problems 75 notes, important 238 notices

error codes 175 errors 147 LEDs

electronic emission 240 FCC, Class A 240 used in this book 2

front view 5 rear view 6 Light Path

card 144 Diagnostics 36 LED errors 147 Light Path Diagnostics table 147

O option

installing 77 option problems 178 order of installation

M major components 78 mechanism

memory modules 98 microprocessors 100, 101

ac box assembly 141 media extract 143 media bay card 139 media-extract mechanism 143 memory

P parameters

batch 63, 68, 69 test 68 parts listing 187 password

active 3, 4 board 115 board assembly 115 diagnostic test 44 problems 177 settings 13 specifications 3 switch card 81, 118 test error codes 174 memory board

administrator 14 clearing power-on 72 override jumper 14 power-on 13 PCI

bus identification 93 expansion slots 92 system test 43 PCI configuration 13 PCI-X

internal connectors 80 replacing 115 retaining latches 140 voltage regulator module (VRM) 116 memory board illustration 98 messages

board 127 board assembly 123 internal connectors 86 planning the ASM interconnect network 26 point-to-point protocol, setting up 23 pointing-device problems 177 POST

diagnostic 38 diagnostic text 38 Ethernet controller 76 SAL/EFI 150 SCSI error 71, 184 service processor 154 microprocessor

description 35 error codes 35 power

board 138 checkout 74 module 121 problems 179 supply specifications 3 power cord customer replaceable units (CRUs) 193 power cords 241 power supply

heat sink 100 installing 100 order of installation 100 power module 100 problems 177 replacing 121 Web site 100 microprocessor board illustration 100

installing 90 · Index 247

Page 226 of the IBM 8688 user manual — T TELNET 23 temperature
Seite 226 · Zum Vergrößern klicken
Seite 226

S SAL/EFI progress codes 183 SCSI

LED errors 180 operating requirements 90 specifications 3 power-control button shield 8 power-on password 13 clearing 72 power-on self-test.

CD-ROM tests 49 diagnostic tests 46 error messages 71, 184 tape test 50 test error codes 164 serial port

See POST power/reset card assembly 144 problem solving 33 problems

test 60 serial port test error codes 169 serial port, cabling 18, 20 service processor messages 154 setting

CD-ROM drive 176 expansion enclosure 176 hard disk drive 176 intermittent 177 memory 177 microprocessor 177 monitor 177 mouse 177 network connection 75 option 178 pointing device 177 power 179 undetermined 185 processor

password override jumper 14 setup

advanced 13 prerequisites, Remote Supervisor Adapter 16 slots

See expansion slots SMP 1 specifications and features 3 Standby mode 8 starting

AMIDiag program 38 starting the server 8 symmetric multiprocessing 1 system

test 42 processor board

assembly 119 voltage regulator module (VRM) 122 product

diagnostic tests 42 error codes 159 error logs 36 error-log entries 149 management 4 reliability 77 security 13 summary 12

R recovering SAL/EFI code 71 reliability, system 77 remote access

enabling 20 remote control password, configuring 25 Remote Supervisor Adapter

T TELNET 23 temperature

cabling and configuring 18 completing configuration 25 component locations 88 configuration 11 enabling remote access 20 features 16 remote control password 25 replacing 130 setup prerequisites 16 removing

ASM 62 ATAPI removables 46 CMOS validity 43 DMA controller 43 Ethernet diagnostic 70 IDE CD-ROM 45 IDE device diagnostic 44 IDE DVD 45 interactive 67 LED 61 memory diagnostic 44 multiprocessor 43 parameters 68 PCI system 43 processor 42 quick 67 RXE port 61

memory-board assembly 100 microprocessor-board assembly 100 replacing

fans 1 and 2 107 fans 3 and 4 108 restoring nonvolatile EFI variables 134 riser card 130 RXE port

error codes 173 test 61

power supply (continued) · data 12 · air 3 test

Page 227 of the IBM 8688 user manual — W Web site
Seite 227 · Zum Vergrößern klicken
Seite 227

SCSI CD-ROM 49 SCSI diagnostic 46 SCSI tape 50 serial port 60 system board 43 USB diagnostic 53 USB functionality 53 USB keyboard 53 USB mouse 60 video diagnostic 51 thermal material

heat sink 102 top cover assembly 137 top power board 138 trademarks 238 turning off the server 8 turning on the server 8

U undetermined problems 185 United States electronic emission Class A notice 240 United States FCC Class A notice 240 updating the firmware 39 USB

functionality test 53 keyboard test 53 mouse test 60 test error codes 167 utility

V video controller

diagnostic tests 51 error codes 167 specifications 3 voltage regulator module (VRM)

memory board 116 midplane board 126 processor board 122

W Web site

compatible options 98, 101 DIMM specifications 99 IBM server products 1 microprocessor information 101 working inside server with power on 77 World Wide Web 1

test (continued) · Configuration/Setup 12 · Index 249

Page 228 of the IBM 8688 user manual — Index
Seite 228 · Zum Vergrößern klicken
Seite 228
Page 228 of the IBM 8688 user manual — Index
Page 229 of the IBM 8688 user manual — Index
Seite 229 · Zum Vergrößern klicken
Seite 229
Page 229 of the IBM 8688 user manual — Index
Page 230 of the IBM 8688 user manual — (1P) P/N: 48P9738
Seite 230 · Zum Vergrößern klicken
Seite 230

Part Number48P9738

(1P) P/N: 48P9738

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu IBM 8688 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu IBM 8688

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

IBM 8688 PDF-Anleitung

262 Seiten·17 MB·Überwachungskamera·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%