Benutzeranleitung / Produktwartung DBP des Produzenten hussman
Zur Seite of 20
/Chino DBP , DBRP 01,03 ISLAND PRODUCE REV .0210 Installation & Operation Manual DBP , DBRP 01,03 ISLAND PRODUCE P/N IGIP-DBP , DBRP 01,03-0210 INST ALLA TION & O P ER A T IO N GUIDE.
IGIP-DBP, DBRP 01,03-0210 2 /Chino A publication of Hussmann ® Chino 13770 Ramona A venue • Chino , California 91710 (909) 628-8942 F AX (909) 590-4910 (800) 395-9229 K eep this booklet with the case at all times for futur e r efer ence .
Rev.0 210 3 Cut & Plan Views DBP-03 Standard Section Produce Scale = 3/8" 38 1 / 2 " 70 1 / 4 " 26 1 / 8 " 35 1 / 4 " 30" 15 3 / 4 "1 5 3 / 4 " Optional Bas.
IGIP-DBP, DBRP 01,03-0210 4 LOCA TION The refrigerated mer chandisers ha ve been designed f or use only in air conditioned stor es where temperatur e and humidity ar e maintained at or below 75 ° F and 55% rela- tive humidity . DO NO T allow air conditioning, electric fans, ov ens, open doors or windows (etc.
Rev.0 210 5 SETTING AND JOINING The sectional construction of these models enable them to be joined in line to giv e the effect of one continuous displa y . A joint trim kit is supplied with each joint. LEVELING IMPOR T ANT! IT IS IMPERA TIVE THA T CASES BE LEVELED FROM FR ONT T O BA CK AND SIDE T O SIDE PRIOR T O JOIN- ING.
IGIP-DBP, DBRP 01,03-0210 6 Plumbing WASTE OUTLET AND P-TRAP The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture. A 1-1/2" P-trap and thr eaded adapter are supplied with each fixture.
Rev.0 210 7 REFRIGERANT TYPE The standard r efrigerant will be R-22 unless otherwise specified on the customer or der . Check the serial plate on the case for inf ormation. PIPING The refrigerant line outlets ar e located under the case. Locate first the electrical box, the outlets are then on the same side of the case but at the opposite end.
IGIP-DBP, DBRP 01,03-0210 8 Electrical WIRING COLOR CODE GREEN GROUND PURPLE ANTI-SWEA T ORANGE LIGHTS YELLOW RECEPT ACLE RED / BLACK T -ST A T /SOLENOID 230V BLACK / WHITE T - S TAT / S O L E N O I D.
Rev.0 210 9 User Information STOCKING Improper temperatur e and lighting will cause serious pr od- uct loss. Discoloration, dehydration and spoilage can be contr olled with proper use of the equipment and handling of pr oduct. Pr oduct temperature should alwa ys be main- tained at a constant and pr oper temperature.
IGIP-DBP, DBRP 01,03-0210 10 Maintenance ELECTRICAL PRECAUTIONS BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component This includes (but not limited to) Fans, Heaters, Thermostats, and Lights.
Rev.0 210 11 Electrical and Refrigeration Specifications TEMPERATURE DISCHG. FAN SIZE DEFROST ELECTRICAL CIRCUITS SELF CONTAINED UNIT DATA BTU AVG AIR T-STAT/ TYPE & FREQ. 115 V. SELF CONTAINED REQ’D EVAP PROD DISC VELOC CUT IN OF NUMBER & E E FANS STD.
IGIP-DBP, DBRP 01,03-0210 12 Electrical Schematics By: Checked By: No. Descripti on: Revisions: dbrp-01.dft Hussmann Corp oratio n 137 70 Ramona Avenue Chino , CA . 91710 (909)- 590- 491 0 Lic.#: 64440 6 Date: Drawing Title: Next A ssembly: Drawn By: Drawing N o.
Rev.0 210 13 MOT OR MOT OR MOT OR S S Brow n General Grounding Area To Sensors Case Controller Com puter Red (115/230V. ) Black/ White (115V. ) T-Sta t Liqu id So lenoid (Optio nal) (Optio nal) Electronic TXV MOTO R MOT OR 8' 12' 16' B B B Or ange Light S witch Lithonia se lf contained Led ge Lights ( Optional) ( No.
IGIP-DBP, DBRP 01,03-0210 14 MO TO R MOT OR MO TO R S S Brown G ene ral Grou nding Are a To S e nsors Case Contro ller Comp ut e r Red (1 15/230V.) Black/Whi te ( 115V.
Rev.0 210 15 APPENDIX A. – Temperature Guidelines Refrigerated The refrigerators should be operated according to the manufacturer’s published engineering specifications for entering air temperatures for specific equipment applications.
IGIP-DBP, DBRP 01,03-0210 16 potentially hazardous food. 1.1 The following recommendations are made for the purpose of arriving at easily taken and understood data which, coupled with other observatio.
Rev.0 210 17 d) Care must be taken when cross merchandising products to ensure that potentially hazardous vegetable products are not placed in non refrigerated areas. e) Display and storage equipment doors should be kept closed during periods of inactivity.
IGIP-DBP, DBRP 01,03-0210 18.
Rev.0 210 19 Limited W arranty This warranty is made to the original user at the original installation site and is not transf erable . Hussmann merchandisers ar e war ranted to be free fr om def ect i.
IGIP-DBP, DBRP 01,03-0210 20 The MODEL NAME and SERIAL NUMBER is required in or der to pr ovide you with the correct parts and information for y our particular unit. They can be found on a small metal plate on the unit. Please note them below for futur e reference.
Ein wichtiger Punkt beim Kauf des Geräts hussman DBP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie hussman DBP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für hussman DBP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von hussman DBP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über hussman DBP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon hussman DBP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von hussman DBP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit hussman DBP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei hussman DBP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.