1. LED Diagnostic Display (system health and DIMM status) 2. Unit ID (UID) LED Switch (front and rear) 3. Universal Media Bay Ejector Button 4. Redundant Hot Plug Power Supply #2 5. 1.44MB Floppy Drive 6. Ultra3 Hard Disk Drive Bays (up to four) 7. CD/DVD-ROM Drive in Universal Media Bay (hot pluggable) 8.
Processor Processor Processor Processor One of the following depending on Model: (4) Intel Xeon Processor MP 3.0 GHz/4MB (4) Intel Xeon Processor MP 2.7 GHz/2MB (4) Intel Xeon Processor MP 2.2 GHz/2MB (4) Intel Xeon Processors MP 2.8 GHz/2MB (4) Intel Xeon Processors MP 2.
Storage Controllers Storage Controllers Storage Controllers Storage Controllers Smart Array 5i Controller (integrated on system board), one internal channel, Ultra3 (supports RAID 0, 1, 1+0, and 5 acr.
ProLiant ProLiant ProLiant ProLiant Essentials Essentials Essentials Essentials Foundation Pack Foundation Pack Foundation Pack Foundation Pack Software Software Software Software Insight Manager 7 an.
Industry Standard Industry Standard Industry Standard Industry Standard Compliance Compliance Compliance Compliance ACPI 1.0b Compliant PCI-X and PCI 2.
Serviceability Serviceability Serviceability Serviceability Innovative Diagnostic Lighting throughout server LED display on front bezel indicates system health and DIMM status LED display on memory ca.
OS Support OS Support OS Support OS Support Microsoft Windows 2000 Microsoft Windows 2000 Advanced Server Microsoft Windows Server 2003 (Standard and Enterprise) LINUX (Red Hat, SuSE) NOTE: NOTE: NOTE: NOTE: For a more complete and up-to-date listing of supported OS's and versions, please visit our OS Support Matrix at: http://www.
Service and Support Service and Support Service and Support Service and Support Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers.
DL740R01 X3.0-4MB, DL740R01 X3.0-4MB, DL740R01 X3.0-4MB, DL740R01 X3.0-4MB, 4096MB (4P) 4096MB (4P) 4096MB (4P) 4096MB (4P) 348445-xxx Processor(s) Processor(s) Processor(s) Processor(s) (4) Intel Xeon Processors MP at 3.
DL740R01 X2.8-2MB, DL740R01 X2.8-2MB, DL740R01 X2.8-2MB, DL740R01 X2.8-2MB, 4096MB (4P) 4096MB (4P) 4096MB (4P) 4096MB (4P) 330531-xxx Processor(s) Processor(s) Processor(s) Processor(s) (4) Intel Xeon Processors MP at 2.
ProLiant DL740 Unique ProLiant DL740 Unique ProLiant DL740 Unique ProLiant DL740 Unique Options Options Options Options Low Line (115V) Cable Kit, C-13 to 5-15P 317424-001 DL740 Folding Metal Cable Management Arm 321716-B21 * NOTE: NOTE: NOTE: NOTE: The Low Line Cable Kit consists of a single, 9 foot, IEC C-13 to 5-15P, 10 Amp cord.
Processor Processor Processor Processor NOTE: NOTE: NOTE: NOTE: Intel Xeon 3.0GHz/4MB, 2.7GHz/2MB, 2.2GHz/2MB, 2.8GHz/2MB, 2.0GHz/2MB, 2.5GHz/1MB, 2.0GHZ/1MB, and 1.5 GHz/1MB processors cannot be mixed in the same server. They all have to be of the same speed and cache size.
Storage Controllers Storage Controllers Storage Controllers Storage Controllers Smart Array 532 Controller 225338-B21 Smart Array 532 Controller (Japan) 225338-291 Smart Array 5304/256 Controller 2835.
HP StorageWorks Ultrium 215 rack-mount (Carbon) - Single drive installed in a 3U rack-mount kit 350544-B21 HP StorageWorks Ultrium 215 Array Module (Carbon) - Offline hot-swap drive for Tape Array 530.
HP StorageWorks 3U Rack-Mount Kit 274338-B21 NOTE: NOTE: NOTE: NOTE: The 3U Rack-Mount Kit can support up to 2 full-height or 4 half-height tape drives and compatible with multiple Single-Ended and LVD SCSI tape drives including DAT, DLT VS80, SDLT 320, Ultrium 215, Ultrium 230, and Ultrium 460 Tape Drives.
Tape Autoloaders Tape Autoloaders Tape Autoloaders Tape Autoloaders DAT Autoloader DAT Autoloader DAT Autoloader DAT Autoloader HP StorageWorks DAT 40x6 Tape Autoloader, External (Flint) C5717C NOTE: .
HP StorageWorks MSL5052S2 Tape Library HP StorageWorks MSL5052S2 Tape Library HP StorageWorks MSL5052S2 Tape Library HP StorageWorks MSL5052S2 Tape Library MSL5052S2, 2 drive, 52 slots, SDLT 320, rack.
Magneto-Optical Magneto-Optical Magneto-Optical Magneto-Optical Jukeboxes Jukeboxes Jukeboxes Jukeboxes HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes HP StorageWorks 9.
Cluster Options Cluster Options Cluster Options Cluster Options ProLiant Cluster Starter Kit 364023-B21 NOTE: NOTE: NOTE: NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see the following QuickSpecs at: http://h18000.
HP StorageWorks Modular HP StorageWorks Modular HP StorageWorks Modular HP StorageWorks Modular Smart Array 1500 Smart Array 1500 Smart Array 1500 Smart Array 1500 Modular Smart Array 1500 Controller .
Modular Power Modular Power Modular Power Modular Power Distribution Units - 1U0U Distribution Units - 1U0U Distribution Units - 1U0U Distribution Units - 1U0U (Up to 32 outlets) NOTE: NOTE: NOTE: NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks).
Third Party Rack Kit Third Party Rack Kit Third Party Rack Kit Third Party Rack Kit Third Party Rack Kit NOTE: NOTE: NOTE: NOTE: The Third party rack kit supports the ML530 G2, ML570 G2, DL740, and DL760 G2.
Rack Options for HP Rack Options for HP Rack Options for HP Rack Options for HP Rack 10000 Series Rack 10000 Series Rack 10000 Series Rack 10000 Series 42U Side Panel – Graphite Metallic 246099-B21 .
HP Factory Express HP Factory Express HP Factory Express HP Factory Express Factory Installation, Racking, and Customization Services Factory Installation, Racking, and Customization Services Factory .
Installation & Start-Up of a ProLiant server and Microsoft O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays. (U.S. Part Number) 240016-002 Installation & Start-Up of a ProLiant server and Microsoft O/S per the Customer Description and/or Data Sheet.
(2-5-2 Part Number for Canada) 24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support for Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System (6-3 Part Number for U.
Canada) 24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for Novell NetWare Operating System (6-3 Part Number for U.S.
HP ProLiant DL740 2.2GHz/2MB or 2.0GHz/1MB, 2048 MB (4P) HP ProLiant DL740 2.2GHz/2MB or 2.0GHz/1MB, 2048 MB (4P) HP ProLiant DL740 2.2GHz/2MB or 2.0GHz/1MB, 2048 MB (4P) HP ProLiant DL740 2.
HP ProLiant DL740 3.0 GHz/4MB, 2.7GHz/2MB, 2.8GHz/2MB or 2.5GHz/1MB 4096 MB (4P) HP ProLiant DL740 3.0 GHz/4MB, 2.7GHz/2MB, 2.8GHz/2MB or 2.5GHz/1MB 4096 MB (4P) HP ProLiant DL740 3.0 GHz/4MB, 2.7GHz/2MB, 2.8GHz/2MB or 2.5GHz/1MB 4096 MB (4P) HP ProLiant DL740 3.
0-3 1" Ultra3 Hot Plug Drive Bays A 1.44-MB Floppy Drive B Slimline CD/DVD-ROM Drive, Hot Pluggable, in Universal Media Bay C Universal Media Bay Eject Button Drive Support Drive Support Drive Su.
Maximum Storage Capacity Maximum Storage Capacity Maximum Storage Capacity Maximum Storage Capacity – (StorageWorks Enclosure SCSI Attached) Internal 587.2 GB (4 x 146.8-GB Ultra320 1" Drives) External 49.325 TB hot plug SCSI storage (24 x (14 x 146.
SSL1016 DLT1 Tape Autoloader MSL6000 (Ultrium 460 - based) Tape Library MSL5026S2 (SDLT 320- based) Tape Library MSL5052S2 (SDLT 320- based) Tape Library MSL5030 (Ultrium 230 - based) Tape Library MSL.
System Unit System Unit System Unit System Unit Dimensions Dimensions Dimensions Dimensions (HxWxD) 7.00 x 17.5 x 28.7 in (17.78 x 44.45 x 72.90 cm) Weight Weight Weight Weight No hard drives installed, two power supplies 105 lb (47.
Power Supply Power Supply Power Supply Power Supply 1100/800W, Hot Plug 1100/800W, Hot Plug 1100/800W, Hot Plug 1100/800W, Hot Plug Redundant Redundant Redundant Redundant (2 standard) One Redundant P.
2352, 2340, 2336, 2048 bytes (Mode-1) 2352, 2340, 2336, 2048 bytes (Mode-2) Diameter 120 mm, 80 mm (with adapter at vertical mounting mode) Loading Mechanism Loading Mechanism Loading Mechanism Loadin.
Two NC7781 PCI-X Two NC7781 PCI-X Two NC7781 PCI-X Two NC7781 PCI-X Gigabit NICs Gigabit NICs Gigabit NICs Gigabit NICs (embedded) Network Interface Network Interface Network Interface Network Interface 10/100/1000-T Compatibility Compatibility Compatibility Compatibility EEE 802.
Ein wichtiger Punkt beim Kauf des Geräts HP ProLiant DL740 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie HP ProLiant DL740 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für HP ProLiant DL740 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von HP ProLiant DL740 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über HP ProLiant DL740 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon HP ProLiant DL740 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von HP ProLiant DL740 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit HP ProLiant DL740. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei HP ProLiant DL740 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.